TNDT2.3. Designed and Manufactured in the USA IMS Engineered Products is. TitanDT Series Catalog. Certified

Similar documents
Titan Cable Management Catalog TCM3.0. IMS Engineered Products is ISO 9001 Certified. Designed and Manufactured in the USA

Certified 1. AMCO Enclosures Containment Brochure. Hot/Cold Aisle Containment Solutions ACB3.0. Designed and Manufactured in the USA

AMCOTN1.1. Certified. Designed and manufactured in the USA.

DATACOM CABINETS SOLUTION GUIDE

Vertiv VR Rack 1.0 GENERAL

ELECTRONICS PACKAGING

VERTIV VR RACK. Selection Guide

V800 Cabinet Solution

Rack Solutions RS-2. Free Standing Racks & Cabinets Wall Mount Racks, Cabinets, & Brackets Shelving Cable Management Accessories RS-5 RS-10 RS-12

V800. Cabinet V800 CABINETS

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing

Product Capabilities and Overview Vertical Enclosures

or

HYPERFRAME CABINET & ENCLOSURE SOLUTIONS

Cabinet Solutions

RUGGED MILITARY GRADE

Rack 111 Catalog. Designed and Built to Exceed Your Needs.

EF-Series EuroFrame Gen 2 Cabinet System

Mounts Racks Accessories Manufactured by:

EMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

RittalXpress TS IT Enclosure Assemble-to-Order Program

VTC Series. features: specifications: options: video cart. what great systems are built on.

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

Mounts Racks Accessories

RE Series Rack from Eaton Product Presentation

Knurr Miracel Server Rack

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

Floor Standing Rack Cabinet

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

PI Server - 19 enclosures

707 Patching Frames. 505 Frames. 303 Frames. 404 & 202 Wallboxes. 505 Cabinets. 303 Cabinets. Cold Aisle Containment. 505 Server Cabinets

S-SERIES 2 Superior Rack Solution for Data Center & Network Closets

VersaPOD and V600. Cabinets. Section Contents. VersaPOD AND V600 CABINETS

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating.

SYSTIMAX Rack and Cabinet Solution

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays

Rack Installation Instructions

platinum 2.0 Enclosure series

WIRE AND CABLE MANAGEMENT

PowerChain Management solutions. Enclosure Solutions

Racks and Cable Management

VersaPOD, V800 and V600 Cabinets

F-SERIES Innovative Rack Solution

Featured Products - RU Marking Standard on Hoffman brand

Shelves, Keyboard Trays and Gland Plates Folding Shelves

SPECTRUM-2 CONSOLES. TEL: WEB: winsted.com

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Free-Standing Type 12 Enclosures

QuickSpecs. HPE G2 Advanced Series Racks. Overview

APC Open Frame Rack Networking Solutions

Specification Sheet: HT SERIES

RACK SOLUTIONS. Rack Enclosures, Wall Mount Racks, Open Frame Racks and Accessories

Netfinity White Paper Netfinity Technology Center

Powerware Enclosure Solutions Product Focus

CABINETS & CONTAINMENT SOLUTIONS GUIDE. designed to be better

Data sheet. Server Rack ( heavy duty rack cabinet ) W:600 = D:1000

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

V-Built Custom Preconfigured Solutions

E-Series Site Preparation Guide

Thermal management. Thermal management

W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS

The Most Advanced Racking Solutions Available!

Hassle-free equipment installation

MPS-Lite. A range of Blank and Connectorized panels in 3 standard widths to fit a 2RU / 3.50 vertical space, plus Adapters to accommodate them.

OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: Fax:

Titan Media Cart. Installation and Operation Manual

Top. Bottom W W W. S I E M O N. C O M

w w w. e l e c t ro n m e t a l. c a

Heavy-duty SmartRack enclosures hold up to 3000 lb (1363 kg) and practices, SmartRack enclosures make your job easier.

Product Profile. Links to PROJECT PHOTOS & OPTIONS ALBUMS Inside COMPLETE CONSOLE FURNITURE SOLUTIONS MODULAR UNIT DESIGN CUSTOM COLORS

Hassle-free equipment installation

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas

ViewPoint Monitoring Console System

E1135C PDU and Pod Upgrade Procedure

SECURE STORAGE SYSTEMS

Audio Visual & Telecoms Rotation Rack. AVATR RACK

System Storage EXP3000 Rack Installation Instructions

Section 15 Cable Demarcation Enclosure

CNC Tool Storage Solutions

LINKEO ENCLOSURES TO FIT YOUR SCS INSTALLATIONS AND BUDGET EDITION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

Hardware & Accessories

RCM & RCM+ enhancement

S-Series Superior Rack Solution for Data Centre & Network Closets

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

Liebert XDA Air Flow Enhancer. User Manual

SLIMBox Series Wall Mounting 19'' SERVER Cabinets W=500mm. Features : Standarts :

NetShelter SX Cable Management. Organize large volumes of cables from networking switches and patch panels

New products spring 2018

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

IRONRIDGE PRODUCT CATALOG

QuickSpecs. HP Rack G2 Series Overview

APC APPLICATION NOTE #146

Standard Product Left-Hinged

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

CNC Tool Storage Solutions

1. Unpacking the System

workstation acessories ErgoChair ergonomic chair designed for the factory worker

Transcription:

TNDT2.3 TitanDT Series Catalog Designed and Manufactured in the US IMS Engineered Products is Certified

bout Us TitanDT Series Innovative Manufacturing Solutions MCO Enclosures has been a leader in the development of enclosure and mounting systems for over seven decades. Our innovations have become the standard for housing electronics and data systems over that time, trusted by companies and institutions providing services that touch virtually every aspect of your daily life. The world relies on us to provide protection for the equipment that tracks satellites, moves trillions of dollars every day, keeps track of vital health information and processes data about distant planets. From military installations to banks and hospitals, MCO Enclosures provides stability and security for the information your world runs on. Today s Data Centers Today s data centers store and process massive amounts of information and financial transactions calculated in milliseconds. Faster computing requirements call for faster servers, creating the need for more power. More power means higher heat loads. Increased cabling means higher-density packaging in the server rack, driving thermal thresholds to new heights. Heat, power and cabling become critical elements in managing overall performance efficiency. Total cost of ownership looms large when designing and creating tomorrow s data centers. MCO addresses these issues with the release of its new flexible framing platform, the TitanDT Racks. Integrated power, cabling and cooling solutions are standard on TitanDT server racks, and make complex data center management simpler. 2 MCO Enclosures TitanDT Catalog

The TitanDT has the highest static and dynamic load ratings in its field. It pairs a sleek aesthetic with an efficient, environmentally friendly design. MCO racks are modular and can be expanded or re-configured to meet current and future needs. Our server/networking racks are available in standard or custom designs. MCO can provide extended levels of development, from simple server rack component design to roomencompassing, multi-bay systems. ll racks ship with everything mounted and assembled according to your design requirements. MCO Enclosures is Certified MCO Enclosures TitanDT Catalog 3

Online Configurator MCO Online Configurator Use this catalog as a guide to design your rack online. MCO Enclosures has a product tool for server racks that provides you with maximum results in a minimal amount of time. No cost, nothing to learn, no software to run this is a simple, fast and accurate Web-based product configurator. Design your racking system in a few quick and simple steps. Choose a cabinet size (H x W x D), and the image adjusts to your specifications. Continue by adding available accessories. Specify exact RU locations for your rack accessories for maximum design flexibility. dd notes to the configuration as required. 4 MCO Enclosures TitanDT Catalog

Results Include ill of material for specific configuration (includes product descriptions and weights) Drawing of configured rack with accessories mounted in place for visual reference Virtual image with zoom capability and 360º view for specific image details Saved configurations for reference and future updates Quote based on specified configuration 3D Virtual Cabinet Included in Configuration MCO Enclosures TitanDT Catalog 5

Now vailable MCO Data Center Products isle Containment Solutions Catalog C1.0 Titan Cable Management Racks Catalog TCMC1.0 6 MCO Enclosures TitanDT Catalog

TitanDT Overview bout TitanDT MCO Enclosures introduces its new TitanDT data rack. The TitanDT is extremely flexible, featuring an extensive selection of rack heights, widths, depths and color choices that target your specific design requirements. Select the door, top panel, side panel and mounting channel options to complete your rack design. Modified or custom rack designs are available by contacting your local MCO sales representative or contacting us directly at 847-391-8100. 12 Doors 14 Side Panels 18 Top Panels 10 Frame 34 ccessories 16 Mounting Channels MCO Enclosures TitanDT Catalog 7

External Features Top Panels Top panels include 8-10 cable egress ports (depending on depth) and come in a variety of designs. M6 pattern in rack s hat section is for cable tray deployment. Design TitanDT racks feature a contemporary design aesthetic with a radius design that blends well in almost every IT environment. Latch Side panels feature spring latches that slide to open/close and hold side panels in place. Doors Curved-face mount doors feature a radius design aesthetic while providing a 77% open pattern to maximize airflow to IT equipment. Door Hinge Doors are reversible (lefthanded/right-handed) with an easy on/off hinging system. 8 MCO Enclosures TitanDT Catalog

Internal Features Construction TitanDT frames consist of fully welded construction with multiple forms to enhance overall static and dynamic load performance. Frame ase Construction The TitanDT base has multiple forms and is enhanced with four caster gussets that encase casters for added protection and support. elow ase Channels Mounting channels feature universal (square-hole) mounting, providing flexibility in metric/domestic hardware deployment. ccessories TitanDT racks have the flexibility to expand to meet the evolving requirements of the IT landscape. bove ase Side Struts TitanDT side struts feature uni-strut side channel design, providing fully adjustable frontto-rear equipment mounting without removing channels. Multiple-ay Joining - Fast & Simple TitanDT racks can be joined together with simple hardware to form multi-bay consoles. No complex joining systems or structures are required simple nut and bolt hardware makes multiple-bay joining fast and easy. MCO Enclosures TitanDT Catalog 9

See Technical section on page 36 Frames Frames TitanDT frames provide exceptional support for your IT infrastructure. Our fully welded frames have the highest load ratings in the Industry. Our extensive selection of mounting channels (pg. 16) expands the frames mounting capabilities (mounting channels are not included with frame). Certified Load Ratings Static: 5,400 lbs. Dynamic: 3,300 lbs. Frames Include Contemporary Design esthetic Certified to MIL STD 901 (Shock) and MIL STD 810 (Vibration) Four ground studs in each corner of the base for grounding Four 1,000 lb. leg levelers for ground support Fully adjustable mounting channels provide more precise, front-torear equipment adjustments Ten Year Warranty 24 Width Frames RU Height 36 Depth 42 Depth 45 Depth 48 Depth 51 R-TN-51U24-36 R-TN-51U24-42 R-TN-51U24-45 R-TN-51U24-48 47 R-TN-47U24-36 R-TN-47U24-42 R-TN-47U24-45 R-TN-47U24-48 44 R-TN-44U24-36 R-TN-44U24-42 R-TN-44U24-45 R-TN-44U24-48 42 R-TN-42U24-36 R-TN-42U24-42 R-TN-42U24-45 R-TN-42U24-48 Note: For 29 width, change 24 to 29 in part number. (i.e. R-TN-51U24-45 becomes R-TN-51U29-45) For 32 width, change 24 to 32 in part number. (i.e. R-TN-51U24-45 becomes R-TN-51U32-45) Frame Color Options Pottery White Light lue Silver 112-T Gunmetal 113-T lack 116-T Pearl Gray Pebble Gray Light eige Cranberry 126-T Medium lue 101-T 111-T 122-T 123-T 125-T 816-T Note: MCO Enclosures offers standard color choices (up to 2 per console) for no extra charge. Custom colors are available and quoted upon request. Glacier White XCP-151T 10 MCO Enclosures TitanDT Catalog

Design TitanDT racks were designed and tested in house and have been certified by independent test labs to provide peace of mind that they can withstand even the most demanding of environments. Our packaging is also engineered to assure you that your rack system arrives on-site as originally manufactured. Tip N Tell labels also protect against possible damage to your rack during product transit. MCO Enclosures TitanDT Catalog 11

See Technical section on page 38 Doors Doors TitanDT vented doors are available in either face or flush mount options. Face mount doors mount to the rack s exterior surface. Flush mount doors mount flush to the exterior of the frame. French doors are available to decrease swing radius versus full-width doors. This maximizes design efficiency within the data center. Curved-Face Vented-Flush French-Flush Door Features: Concealed hinges offer easy on/off release Doors can be mounted as either left-hand or righthand Vented doors feature a 77% open airflow pattern, exceeding major OEM/equipment vendor requirements Swing handles with keyed locks Combination swing handle locks optional Locks can be ordered keyed alike or separately (keyed separately option quoted upon request) Optional solid inserts for flush doors available for when thermal requirements change Door Features 24 Width Flush RU Height Vented Door with Solid Insert 51 DK-FZ-51U24 DK-FZ-SPI-51U24 47 DK-FZ-47U24 DK-FZ-SPI-47U24 44 DK-FZ-44U24 DK-FZ-SPI-44U24 42 DK-FZ-42U24 DK-FZ-SPI-42U24 24 Width Curved-Face RU Height Vented 51 DK-CZ-51U24 47 DK-CZ-47U24 44 DK-CZ-44U24 42 DK-CZ-42U24 Swing handle with lock Secures valuable equipment Combination handle (H907) Optional handle with keyed lock 24 Width French-Flush RU Height Vented Door with Solid Insert 51 DFK-FZ-51U24 DFK-FZ-SPI-51U24 47 DFK-FZ-47U24 DFK-FZ-SPI-47U24 44 DFK-FZ-44U24 DFK-FZ-SPI-44U24 42 DFK-FZ-42U24 DFK-FZ-SPI-42U24 Vented pattern 77% open pattern Note: For 29 width, change 24 to 29 in part number. (i.e. DK-CZ-51U24 becomes DK-CZ-51U29) For 32 width, change 24 to 32 in part number. (i.e. DK-CZ-51U24 becomes DK-CZ-51U32) 12 MCO Enclosures TitanDT Catalog

Flush Door Solid Inserts TitanDT vented flush doors can be expanded as thermal requirements for your racks change. Solid cover panels are available to convert front-to-rear (hot aisle) cooling to an overhead duct design. Simply add the solid cover panels beneath the existing screens. Solid Insert Part Numbers French Door Solid Insert: SPI-DF-xxUyy Flush Door Solid Insert: SPI-D-xxUyy Note: For solid insert part numbers, replace xx with the RU height and yy with the width. Note: Used with Overhead Chimney Solution MCO Enclosures TitanDT Catalog 13

See Technical section on page 39 Side Panels Side Panels Side panels have been designed for use as baffle panels to contain thermal loads within a rack, or as side panels to close off an existing side of a rack. Side panels mount within the side perimeters of the rack for a flush design aesthetic. Side Panel Features: Side panels come with keyed lock, keeping panels secure Side panel latches provide easy on/off mechanism Side panels can be mounted in place between multiple-bay consoles Side Panel Features Side Panel Cable Management Side Panel with Levelers Keyed Lock TitanDT side panels come with a lock that keeps the side panel secure. Side Panel Latch TitanDT side panels include a latch system for easy installation and removal. Side Panel RU Height 36 Depth 42 Depth 45 Depth 48 Depth 51 SPK-FS-51U-36 SPK-FS-51U-42 SPK-FS-51U-45 SPK-FS-51U-48 47 SPK-FS-47U-36 SPK-FS-47U-42 SPK-FS-47U-45 SPK-FS-47U-48 44 SPK-FS-44U-36 SPK-FS-44U-42 SPK-FS-44U-45 SPK-FS-44U-48 42 SPK-FS-42U-36 SPK-FS-42U-42 SPK-FS-42U-45 SPK-FS-42U-48 Cable Management Side Panel RU Height 36 Depth 42 Depth 45 Depth 48 Depth 51 TPS-51U-36 TPS-51U-42 TPS-51U-45 TPS-51U-48 47 TPS-47U-36 TPS-47U-42 TPS-47U-45 TPS-47U-48 44 TPS-44U-36 TPS-44U-42 TPS-44U-45 TPS-44U-48 42 TPS-42U-36 TPS-42U-42 TPS-42U-45 TPS-42U-48 14 MCO Enclosures TitanDT Catalog

Cable Management Side Panels Unlike side panels, cable management side panels bolt to cable raceways, spacer panels, door kits and other types of cable management accessories that finish off the end of a row or bay. Cable Management Side Panel Features: Side panels bolt to cable management accessories Levelers at bottom of side panel included for additional ground support MCO Enclosures TitanDT Catalog 15

See Technical section on page 40 Mounting Channels Mounting Channels Mounting channels are fully adjustable within the rack to provide much more precise equipment adjustments. Mounting channels feature an M6 square-hole pattern and have individually numbered RUs for each rack unit, resulting in fast and easy equipment installation. ll TitanDT mounting channels have a durable black powder coat finish. MCX Profile MCW Profile Reducer MCX Profile Features: For standard 19 mounting on 24 overall rack widths (24 width frames require two pairs of MCX mounting channels per frame) MCW Profile Reducer Features: Provides 19 front-mounting space in 29 or 32 overall rack width Cable egress included with edge guard and cover MCL1 Profile Reducer 1RU Device Features: Provides 19 front-mounting space in a 29 overall rack width 1.75 high by 17 cutouts for 1RU equipment mounting, resulting in additional rack space MCL1 Profile Reducer - 1RU Device MCW Profile Reducer - 1RU or 2RU Finger Channels Channels for 24 or 29 Width Rack RU MCX Profile MCW Profile Reducer Height MCL1 Profile Reducer - 1U Device MCW Profile Reducer Finger Channel Features: Provides 19 front-mounting space in 29 or 32 overall rack width 1RU or 2RU wire finger managers provide cable management support to individual RUs in rack Metal fingers have a depth of 9.25 to accommodate larger cable bundles MCW Profile Reducer - 1RU Finger MCW Profile Reducer - 2RU Finger 51 MCX-TN-S-51U MCW-TN-S-51U MCL1-TN-S-P51U MCW-TN-S-F51U-1 MCW-TN-S-F51U-2 47 MCX-TN-S-47U MCW-TN-S-47U MCL1-TN-S-P47U MCW-TN-S-F47U-1 MCW-TN-S-F47U-2 44 MCX-TN-S-44U MCW-TN-S-44U MCL1-TN-S-P44U MCW-TN-S-F44U-1 MCW-TN-S-F44U-2 42 MCX-TN-S-42U MCW-TN-S-42U MCL1-TN-S-P42U MCW-TN-S-F42U-1 MCW-TN-S-F42U-2 Channels for 32 Width Rack RU MCW Profile Reducer Height MCL1 Profile Reducer - 1U Device 51 MCW-TN-S-32-51U MCL1-TN-S-32-P51U 47 MCW-TN-S-32-47U MCL1-TN-S-32-P47U 44 MCW-TN-S-32-44U MCL1-TN-S-32-P44U 42 MCW-TN-S-32-42U MCL1-TN-S-32-P42U 16 MCO Enclosures TitanDT Catalog

1RU & 2RU Finger Channels Finger mounting channels feature metal fingers that are 9.25 deep in 1RU and 2RU designs for cablerouting requirements. 1RU finger channels have a full 1.75 from finger center to finger center as the 2RU finger channel s center-to-center open spacing is 3.50 for larger cabling requirements. Each RU is labeled on the mounting channel for fast, easy equipment placement. 1RU Finger Mounting Channel 2RU Finger Mounting Channel MCO Enclosures TitanDT Catalog 17

See Technical section on page 41 Top Panels Top Panels TitanDT top panels provide expanded options to address today s cooling and cabling requirements. Top panels provide an additional level of security as they are bolted directly to the top of the rack. Solid Vented Cover Plate Each panel features multiple cable egress ports, which include dust covers for when not in use (not available on dual brush strip top panel) Solid One-piece, solid-plate construction seats within the top of the rack rush Strip Dual rush Strip Vented One-piece construction featuring a vented section of.187 x.937 slots Cover Plate Two-piece, solid-plate construction with removable 19 x 10 solid cover plate rush Strip Two-piece construction with removable 5 wide brush strip sections Cable Egress Ports Dual rush Strip One-piece construction with dual brush strips Two-piece construction with dual removable 5 wide brush strip sections Solid Vented Cover Plate TP-FS-24-48 TP-FV-24-48 TP-FC-24-48 TP-FS-24-45 TP-FV-24-45 TP-FC-24-45 TP-FS-24-42 TP-FV-24-42 TP-FC-24-42 TP-FS-24-36 TP-FV-24-36 TP-FC-24-36 rush Strip TP-F-24-48 TP-F-24-45 TP-F-24-42 TP-F-24-36 Dual rush Strip TP-FD-24-48 TP-FD-24-45 TP-DF-24-42 TP-FD-24-36 Cable Egress Ports Cable egress ports address demands of wire and cable deployment above the server rack. Note: For 29 width, change 24 to 29 in part number. (i.e. TP-FS-24-45 becomes TP-FS-29-45) For 32 width, change 24 to 32 in part number. (i.e. TP-FS-24-45 becomes TP-FS-32-45) 18 MCO Enclosures TitanDT Catalog

Top Panel Expansion See Overhead Chimney Solution on page 30 TitanDT top panels with cover plate can be ordered as a solid top panel to support front-to-rear cooling in racks. Or the cover plate can be removed and the chimney component added when designs call for hot air to be exhausted away from the rack to the overhead CRC system for recirculation. For a complete system, order the overhead chimney solution kit, which includes top panel, chimney, and air deflector. Top Panel Cover Plate for front-to-rear cooling Cover Plate removed and Overhead Chimney Solution added for overhead CRC deployment MCO Enclosures TitanDT Catalog 19

Cable Management Vertical Cable Management MCO provides a variety of vertical cable management options that allow you to organize and manage all of your cabling. This flexible solution allows you to create a system that deals with vertical cabling at the inside rear of the rack (cable lacing strip and power panel) or between two or more racks (vertical cable raceways). 26 Finger racket Kit 23 Cable Lacing Strip 22 Power/Cable Panel Cable Raceway Kit 26 Cable Raceway Door Spacer Panel ack Panel 20 MCO Enclosures TitanDT Catalog

Cable Management Overhead Cable Management Overhead cable management options allow you to organize and manage overhead cabling. Raceways can be mounted to the front and rear of the server rack. Choose between brush strip panels which provide flexible cabling egress while maintaining thermal load balancing or cover plates that can be removed and configured as needed. Overhead Strut Kit Overhead Cable Raceway 29 1RU Overhead Cable Raceway 4RU Overhead racket Kit Overhead Raceway Spacer Kit MCO Enclosures TitanDT Catalog 21

See Technical section on page 43 Cable Management Power/Cable Panel vailable in five rack heights and two widths, power/ cable panels mount in the rear of the rack and provide mounting support for PDUs and cable bundles. Power/cable panels have a combination of keyhole pattern slots, M6 square holes and cable egress ports. Power/Cable Panel Features: Tool-less mounting makes PDUs mounting fast and easy Frees up additional RU space in a rack as PDUs are mounted to the panel rather than in the panel opening Properly organized cabling and PDUs at the rear of the rack do not block hot air exhausted from the back of servers. Hot, trapped air increases back pressure and results in higher thermal loads Panels are an efficient cable management solution that neatly organizes your cable bundles Power/Cable Panel RU Height 7" Width 10" Width 51 PCP-51U-7 PCP-51U-10 47 PCP-47U-7 PCP-47U-10 44 PCP-44U-7 PCP-44U-10 42 PCP-42U-7 PCP-42U-10 Tool-less Power Strip Mounting 1 Power/Cable Panels The power/cable panel provides tool-less keyhole mounting for PDUs, making power and cable management fast and easy. 2 3 22 MCO Enclosures TitanDT Catalog

See Technical section on page 43 Cable Management Cable Lacing Strip vailable in five rack heights and a 5 width, cable lacing strips mount in the rear of the rack or between mounting channels and provide mounting support for PDUs and cable bundles. Cable lacing strips have a combination of M6 holes for cable ring mounting (HK-CR1) or equipment tie-down, while the slots can accept cable ties, fasteners, etc. Cable Lacing Strip Features: Frees up additional RU in rack as PDUs are mounted to panel rather than panel opening Properly organized cabling and PDUs at rear of the rack do not impede/block hot air exhausted from back of servers. Hot trapped air increases back pressure and results in higher thermal loads Panels are an efficient cable management solution that neatly organizes your cable bundles Cable Lacing Strip RU Height 5" Width 51 CLS-51U-5 47 CLS-47U-5 44 CLS-44U-5 42 CLS-42U-5 Horizontal Cable Manager HCM Panels have a 2RU panel height (3.50 ) and feature 10 ga. steel construction. vailable in 4 and 7 depths. Cable Ring Kit Cable Ring Kit Cable rings easily mount to M6 holes in power/cable panels or cable lacing strips and provide an immediate tiedown point for cabling. Sold in packs of 10. HCM4-4 Depth HCM7-7 Depth HK-CR1 MCO Enclosures TitanDT Catalog 23

See Vertical Cable Management section on page 26 Selecting a Cable Raceway Mix & Match Combinations Flexible cable management design allows you to mix and match an extensive variety of cable raceway options. ll raceway options are available in 6, 8, 10 and 12 panel widths. Vertical Finger racket Kit Cable Raceway Doors ack Panel Spacer Panel Cable Raceway Kit with out ack Panel Cable Raceway Kit Cable Management Side Panel 24 MCO Enclosures TitanDT Catalog

Cable Raceway Doors TitanDT raceway doors are available in either solid or vented models and provide complete access to all of your cabling and power management. They are the same nominal height as the specified rack. These doors feature easy-release pins at the top and bottom for easy on/off requirements. Doors are designed for universal (left-hand or right-hand) mounting. Vented doors feature a 77% open pattern screen for optimal airflow and heat dissipation. oth doors feature finger latch that slides open or closed, holding the door in place. Vented Cable Raceway Door Solid Cable Raceway Door MCO Enclosures TitanDT Catalog 25

See Technical section on page 42 Vertical Cable Management Vertical Cable Management Vertical cable options mount to the sides of two TitanDT racks, forming raceways for large bundle drops of cabling or power strip mounting. This storage between racks takes 0RU, organizes cable and power requirements neatly and works against heat buildup that blocks exhausted air at the rear of the rack. Create your choice of 6 or 8 *width openings between racks for cable management. Cable Raceway Kit Includes choice of solid or vented front door, back panel and choice of 1RU or 2RU fingers that are 9.25 deep Cable Raceway Kit Cable Raceway Kit without ack Panel ack Panel with Finger Channels Cable Raceway Kit without ack Panel No back panel included Includes choice of solid or vented front door and choice of 1RU or 2RU fingers that are 9.25 deep Cable Raceway Doors vailable in solid or vented, providing easy access to cabling between two racks Cable Raceway Doors ack Panel Vertical Finger racket Kit Spacer Panel Spacer Panel Creates space between racks that requires no access to the cabling ack Panel Used for cable management or power strip mounting between racks Note: lso offered with 1RU or 2RU fingers The finger bracket kit mounts to the side of the rack and accepts large bundle drops of cabling between frames, routing to vertical cable managers that distribute the cabling to 1RU or 2RU sections of patch panels. Sold in pairs. Vertical Finger racket Kit -1RU & 2RU Choose between 1RU or 2RU Finger rackets RU Height 1 RU 2 RU 51 VFK-51U-1 VFK-51U-2 47 VFK-47U-1 VFK-47U-2 44 VFK-44U-1 VFK-44U-2 42 VFK-42U-1 VFK-42U-2 1RU 2RU 26 MCO Enclosures TitanDT Catalog

See Technical section on page 42 Vertical Cable Management Cable Raceway Kit (vented door, back panel, 2 ea 1RU finger channels) RU Height 6" Width 8" Width Note: For 2RU finger channels, change 1U to 2U in part number. (i.e. VCTK-51U6-1U- 51 VCTK-51U6-1U-VD VCTK-51U8-1U-VD VD becomes VCTK-51U6-2U-VD) 47 VCTK-47U6-1U-VD VCTK-47U8-1U-VD For solid doors, change VD to SD. 44 VCTK-44U6-1U-VD VCTK-44U8-1U-VD 42 VCTK-42U6-1U-VD VCTK-42U8-1U-VD Cable Raceway Kit without ack Panel (vented door, 2 ea 1RU finger channels) RU Height 6" Width 8" Width 51 VCTK-51U6-1U-VD- VCTK-51U8-1U-VD- 47 VCTK-47U6-1U-VD- VCTK-47U8-1U-VD- 44 VCTK-44U6-1U-VD- VCTK-44U8-1U-VD- Note: For 2RU finger channels, change 1U to 2U in part number. (i.e. VCTK-51U8-1U-VD- becomes VCTK-51U8-2U-VD-) For solid doors, change VD to SD. 42 VCTK-42U6-1U-VD- VCTK-42U8-1U-VD- Cable Raceway Doors (vented door) RU Height 6" Width 8" Width 51 VFTD-Z-51U-6 VFTD-Z-51U-8 Note: For solid doors, change Z to S. 47 VFTD-Z-47U-6 VFTD-Z-47U-8 44 VFTD-Z-44U-6 VFTD-Z-44U-8 42 VFTD-Z-42U-6 VFTD-Z-42U-8 Spacer Panel RU Height 6" Width 8" Width 51 VCTS-51U-6 VCTS-51U-8 47 VCTS-47U-6 VCTS-47U-8 44 VCTS-44U-6 VCTS-44U-8 42 VCTS-42U-6 VCTS-42U-8 ack Panel RU Height 6" Width 8" Width 51 VCTS-51U6 VCTS-51U8 47 VCTS-47U6 VCTS-47U8 44 VCTS-44U6 VCTS-44U8 42 VCTS-42U6 VCTS-42U8 ack Panel with 1RU Fingers (back panel, 2 ea 1RU finger channels) RU Height 6" Width 8" Width Note: For 2RU finger channels, change 1U to 2U in part number. (i.e. VCTF-51U-1-6 becomes VCTF- 51 VCTF-51U-1-6 VCTF-51U-1-8 51U-1-6) 47 VCTF-47U-1-6 VCTF-47U-1-8 For solid doors, change VD to SD. 44 VCTF-44U-1-6 VCTF-44U-1-8 42 VCTF-42U-1-6 VCTF-42U-1-8 MCO Enclosures TitanDT Catalog 27

Overhead Cable Management Mix & Match Combinations The TitanDT overhead cable management system is a flexible design integration solution. ccessories can be mixed and matched to meet your specific design requirements. Overhead accessories can be shipped mounted to racks or added at a later date, depending on current and future designs. Our new 1RU overhead cable raceway provides overhead mounting for patch panels. This frees up additional rack units within the rack for IT hardware mounting. Overhead Cable Raceway Overhead Raceway Spacer Kit 1RU Overhead Cable Raceway 4RU Overhead racket Kit Overhead Strut Kit 28 MCO Enclosures TitanDT Catalog

See Technical section on page 43 Overhead Cable Management Overhead Cable Management Overhead Cable Raceway OCT-24-10 (24 Rack Width) OCT-29-10 (29 Rack Width) OCT-32-10 (32 Rack Width) Overhead Raceway Spacer Kit OCT-SK-6 (6 Wide) OCT-SK-8 (8 Wide) OCT-SK-10 (10 Wide) OCT-SK-12 (12 Wide) 1RU Overhead Cable Raceway OCTWC-24-10 (24 Rack Width) OCTWC-29-10 (29 Rack Width) OCTWC-32-10 (32 Rack Width) 4RU Overhead racket Kit OP-TN-4U24 OP-TN-4U29 OP-TN-4U32 Overhead cable management options allow you to organize and manage overhead cabling. Raceways can be mounted to either the front and rear of the rack. Choose between brush strip panels which provide flexible cabling egress while maintaining thermal load balancing and cover plates, which can be removed and configured as needed. Overhead Cable Raceway Full access to the front, top panel cable egress ports Durable black powder coat finish 10 depth 1RU Overhead Cable Raceway Used to mount 1RU devices, such as patch panels, in the overhead cable raceway, freeing up valuable RU space within the rack 10 depth Overhead Raceway Spacer Kit Used when a TitanDT rack has both vertical and overhead cable raceways, as it is designed to cover the open area between two racks where a raceway is incorporated Overhead Strut Kit TSHK-12 Overhead Cable Management 4RU Overhead racket Kit 4RU bracket kit allows up to 4RU of patch panels to be mounted overhead on a rack 4RU solid blanking panel can also be used as a costeffective face plate solution that covers exposed power and cable cords on the top and front of your TitanDT rack Overhead Strut Kit Struts accept wire baskets and other types of overhead raceway systems Kit contains two 12 length, 14ga. formed channels with M6 mounting hardware Expansion Slots Expansion slots at the top of the frame can accommodate other accessories, such as the overhead cable raceway. MCO Enclosures TitanDT Catalog 29

See Technical section on page 44 Cooling Overhead Chimney Solution Isolating and containing the heat within the rack and directing it back into the overhead CRC system is an effective passive cooling solution for high-density racks. Chimney solutions prevent hot and cold air mixing in the cabinet, as well as hot air recirculation to the front of the rack. These systems are cost-effective and efficient, reducing the cost of over-cooling your data center. Kit includes top panel, air deflector and top exhaust duct. Top Duct Exhaust Kit (35-60 ) Top Duct Exhaust Kit (20-35 ) 20-35 Height 24" Width TP-FD3-24-48 TP-FD3-24-45 TP-FD3-24-42 TP-FD3-24-36 35-60 Height 24" Width TP-FD6-24-48 TP-FD6-24-45 TP-FD6-24-42 TP-FD6-24-36 Note: For 29 width, change 24 to 29 in part number. (i.e. TP-FD6-24-45 becomes TP-FD6-29-45) For 32 width, change 24 to 32 in part number. (i.e. TP-FD6-24-45 becomes TP-FD6-32-45) Included with Overhead Chimney Solution: Top Panel without Cover Plate ir Deflector Top Duct Exhaust (Heights of 20-35 or 35-60 ) 30 MCO Enclosures TitanDT Catalog

Cooling 44 See Technical section on page 43 44 Network Switch Cooling Solution Network switches typically have a large volume of cabling associated with them. The heat they generate must be redirected from side-to-side and front-torear. MCO has created a passive solution for switch applications. Note: Network Switch Cooling Solution includes top panel, baffle panel and vented rear door. Note: Customer must select front raceway option of equal width to use with Network Switch Cooling Solution (ie. cable raceway door, cable raceway kit, etc. See page 27) lso must select a side panel and door. 42 Depth RU Height 6" Width 8" Width 51RU NSCS-51U6-42 NSCS-51U8-42 47RU NSCS-47U6-42 NSCS-47U8-42 44RU NSCS-44U6-42 NSCS-44U8-42 42RU NSCS-42U6-42 NSCS-42U8-42 Note: For 45 depth, change 42 to 45 in part number. (i.e. NSCS-51U6-42 becomes NSCS-51U6-45) For 48 depth, change 42 to 48 in part number. (i.e. NSCS-51U6-42 becomes NSCS-51U6-48) Network Switch Cooling Solution Tool-less lanking Panels Steel lanking Panels Tool-less Cover empty spaces in panel openings Optimize air circulation Co-Poly lanking Panels (with 6 ea. 1RU panels) Square hole only RU Height Steel Panel Part Number RU Height Co-Poly Panel Part Number 1RU PT24-1U 6RU P-6U-P 2RU PT24-2U 3RU PT24-3U 4RU PT24-4U 8RU PT24-8U MCO Enclosures TitanDT Catalog 31

Power Power Options Choose from our standard selection of power components, which address today s demands for power distribution, environmental monitoring and security concerns. We can supply power strips as listed or for a more extensive selection you can contact us directly. PDR1908N-20-120P1-0010 Power Specifications 15 and 20 mp strips are available in 120V and 208V, in metered or non-metered versions dvanced 3 phase models in 20 and 30 mp 60 mp single phase in metered or non-metered Most PDU s have tool-less mounting to TitanDT power/cable panels ll models have receptacle and plug options ll models have a 10 power cord Other power options are available and quoted upon request Made in the US Part Number Length # of Outlets Recpticle Type mp Phase Volts Circuit reaker PDR6633D-D-208P3-2010T 66" 24 C-13 30 208V Yes L21-30P Yes 3 C-19 30 3 208V 6 5-20R 20 120V PDR6624E-20-120P3-0010T 66" 21 C-13 20 3 120V Yes L21-30P Yes 3 C-19 20 120V PDR7224E-30-208P3-2010T 72" 21 C-13 30 3 208V Yes L21-30P Yes 3 C-19 PDR1908N-20-120P1-0010 19" 8 5-20R 20 Single 120V Yes 5-20P Yes Plug Power Meter PDR6624N-20-120P3-0010T 66" 24 5-20R 20 3 120V Yes L21-30P Yes PDR6624N-20-120P3-2010T 66" 24 5-20R 20 3 120V Yes L21-30P Yes PDR6630E-30-208P3-2010T 66" 24 C-13 30 3 208V Yes L21-30P Yes 6 C-19 PDR6630E-20-120P1-0010 66" 24 C-13 20 Single 120V No 5-20P Yes 6 C-19 PDR6624N-30-120P1-2010T 66" 24 5-20R 30 Single 120V Yes L5-30P Yes PDR6630E-60-208P1-2010E 66" 24 C-13 60 Single 208V Yes IEC 60309 Yes 6 C-19 32 MCO Enclosures TitanDT Catalog

Power PDR6633D-D-208P3-2010T PDR6624N-20-120P3-0010T PDR6630E-30-208P3-2010T PDR6630E-20-120P1-0010 PDR6624N-30-120P1-2010T PDR6630E-60-208P1-2010E Note: Not all PDUs shown Power Specifications Part Number Length # of Outlets Recpticle Type mp Phase Volts Circuit reaker Plug Power Meter PDU3910N-15-120P1-1510 39" 10 NEM 5-15R 15 Single 120V Yes- Thermal NEM 5-15P Straight NO PDU3910N-15-120P1-1510T 39" 10 NEM 5-15R 15 Single 120V Yes- Thermal NEM L5-15P TL NO PDU4814N-15-120P1-1510 48" 14 NEM 5-15R 15 Single 120V Yes- Thermal NEM 5-15P Straight NO PDU4814N-15-120P1-1510T 48" 14 NEM 5-15R 15 Single 120V Yes- Thermal NEM L5-15P TL NO PDU6620N-15-120P1-1510 66" 20 NEM 5-15R 15 Single 120V Yes- Thermal NEM 5-15P Straight NO PDU6620N-15-120P1-1510T 66" 20 NEM 5-15R 15 Single 120V Yes- Thermal NEM L5-15P TL NO PDU3910N-20-120P1-2010 39" 10 NEM 5-20R 20 Single 120V Yes- Thermal NEM 5-20P Straight NO PDU3910N-20-120P1-2010T 39" 10 NEM 5-20R 20 Single 120V Yes- Thermal NEM L5-20P TL NO PDU4814N-20-120P1-2010 48" 14 NEM 5-20R 20 Single 120V Yes- Thermal NEM 5-20P Straight NO PDU4814N-20-120P1-2010T 48" 14 NEM 5-20R 20 Single 120V Yes- Thermal NEM L5-20P TL NO PDU6620N-20-120P1-2010 66" 20 NEM 5-20R 20 Single 120V Yes- Thermal NEM 5-20P Straight NO PDU6620N-20-120P1-2010T 66" 20 NEM 5-20R 20 Single 120V Yes- Thermal NEM L5-20P TL NO MCO Enclosures TitanDT Catalog 33

See Technical section on page 45 ccessories Solid U-SHS-1725 (17-25 ) U-SHS-2540 (25-40 ) Vented U-SHV-1725 (17-25 ) U-SHV-2540 (25-40 ) Heavy Duty Shelves Heavy duty shelves are 1.75 H (1RU), fit 19 width panel openings and have depths of 17 up to 40. They are available in solid or vented models and are load-rated to support up to 300 lbs. Shelves mount to the front and rear of the mounting channels. Standard finish is black powder coat. Vented U-SH1 (15 lb. load rating) U-SH2 (50 lb. load rating) U-SH3 (60 lb. load rating) U-SH4 (70 lb. load rating) U-SH5 (80 lb. load rating) Light Duty Shelf U shelves are light duty and mount to the front of the mounting channel. The shelves are 19 wide,16 deep and available in the following heights: 1RU, 2RU, 3RU, 4RU and 5RU. Standard finish is black powder coat. Drawer With Lock U-DR2-LK (30 lb. load rating) U-DR3-LK (40 lb. load rating) U-DR4-LK (50 lb. load rating) Drawer with Lock U drawers are perfect for applications that require a lockable, light-weight storage solution. They are 19 wide, 18 deep, feature a keyed lock and mount to the front of the mounting channels. Drawers are available in heights of 2RU, 3RU and 4RU. Standard finish is black powder coat. 34 MCO Enclosures TitanDT Catalog

See Technical section on page 45 ccessories Light Duty Caster C-C175 M6 HKM6-25 Joining Kit HK-R-TN CHG-TN-2536-D (25 to 36 Depths) Heavy Duty Caster C-C1200 Dzus M6 HKDZ-25 djustable Chassis Guides Chassis guides have a 2 H x 2 W profile and are fully adjustable from 25 thru 36. The flanges support component-mounted hardware in a minimal profile. Chassis guides support 125 lbs. Standard finish is black powder coat. Casters Data racks sometimes require casters for mobility. Light duty casters include assembly hardware to mount the casters to the rack. Light duty -175 lbs. load rating - adds 1 to overall frame height Heavy duty -1,200 lbs. load rating - adds 1.75 to overall frame height Hardware Kits Each rack ships with 50 ea. DZUS M6 inserts and screws to make mounting hardware/components easy to install. dditional mounting hardware is available for equipment mounting: Square Hole Mounting Hardware Kits HKM6-25 or 50- M6 hardware for equipment mounting. Includes 25 or 50 M6 mounted screws. HKDZ-25- (25) M6 Metric Dzus easy inserts and M6 clear chromate screws. Frame-Joining Hardware HK-R-TN- Frame-joining kit (eight pieces) Visit our Online Configurator Now that you ve selected what you want in your TitanDT rack, get a head start and go to our online configurator for fast and easy design. Results Include ill of material for specific configuration includes product descriptions and weights Drawing of configured rack with accessories mounted in place for visual reference Virtual image with zoom capability and 360º view for specific image details Saved configurations for reference and future updates Quote based on specified configuration MCO Enclosures TitanDT Catalog 35

See Frame section on page 10 Technical - Frame TitanDT Frame Construction Four separate 14 ga. (.074) welded CRS main channels provide a rugged frame assembly. Vertical frame channels also provide exceptional direct floorbearing support. C Usable Height E Panel Opening Width Overall Height 14 ga. (.074) CRS uni-strut channels (sides) are welded to dual return flanges. Formed 12 ga. (.104) CRS gussets are welded to frame base corners for added strength and also serve as caster brackets. Caster brackets provide additional protection from forklift blades that can damage racks in transportation to site deployment. Easy front-to-rear, full-depth equipment adjustments based on uni-strut design. Four weld studs are included in each frame base for grounding requirements. dd to overall height Heavy duty casters- 1.75 Light duty casters- 1 Leg levelers-.625 RU Height D Overall Width 24 Width (Material: 14ga. CRS) 36 Depth () (33.75 usable) Overall Depth 42 Depth () (39.75 usable) 45 Depth () (42.75 usable) Certifications and Testing EI 310D Equipment Mounting Mil Std. 810D Vibration ISO 9001:2008 Certified Static Load Rating - 5,400 lbs. Certified Dynamic Load Rating - 3,300 lbs. 48 Depth () (45.75 usable) Overall Height () Usable Height (C) Overall Width (D) Panel Opening Width (E) 51 R-TN-51U24-36 R-TN-51U24-42 R-TN-51U24-45 R-TN-51U24-48 95.62" 89.25" 24" 19.75" 47 R-TN-47U24-36 R-TN-47U24-42 R-TN-47U24-45 R-TN-47U24-48 88.62" 82.25" 24" 19.75" 44 R-TN-44U24-36 R-TN-44U24-42 R-TN-44U24-45 R-TN-44U24-48 83.37" 77" 24" 19.75" 42 R-TN-42U24-36 R-TN-42U24-42 R-TN-42U24-45 R-TN-42U24-48 79.87" 73.5" 24" 19.75" 29 Width (Material: 14ga. CRS) RU Height 36 Depth () (33.75 usable) 42 Depth () (39.75 usable) 45 Depth () (42.75 usable) 48 Depth () (45.75 usable) Overall Height () Usable Height (C) Overall Width (D) Panel Opening Width (E) 51 R-TN-51U29-36 R-TN-51U29-42 R-TN-51U29-45 R-TN-51U29-48 95.62" 89.25" 29" 24.75" 47 R-TN-47U29-36 R-TN-47U29-42 R-TN-47U29-45 R-TN-47U29-48 88.62" 82.25" 29" 24.75" 44 R-TN-44U29-36 R-TN-44U29-42 R-TN-44U29-45 R-TN-44U29-48 83.37" 77" 29" 24.75" 42 R-TN-42U29-36 R-TN-42U29-42 R-TN-42U29-45 R-TN-42U29-48 79.87" 73.5" 29" 24.75" 32 Width (Material: 14ga. CRS) RU Height 36 Depth () (33.75 usable) 42 Depth () (39.75 usable) 45 Depth () (42.75 usable) 48 Depth () (45.75 usable) Overall Height () Usable Height (C) Overall Width (D) Panel Opening Width (E) 51 R-TN-51U32-36 R-TN-51U32-42 R-TN-51U32-45 R-TN-51U32-48 95.62" 89.25" 29" 24.75" 47 R-TN-47U32-36 R-TN-47U32-42 R-TN-47U32-45 R-TN-47U32-48 88.62" 82.25" 29" 24.75" 44 R-TN-44U32-36 R-TN-44U32-42 R-TN-44U32-45 R-TN-44U32-48 83.37" 77" 29" 24.75" 42 R-TN-42U32-36 R-TN-42U32-42 R-TN-42U32-45 R-TN-42U32-48 79.87" 73.5" 29" 24.75" 36 MCO Enclosures TitanDT Catalog

See Frame section on page 10 Technical - Frame E C C D Front View Side View D Top View D ase View MCO Enclosures TitanDT Catalog 37

See Doors section on page 12 Technical - Doors C C C C Curved-Face Flush French-Flush Curved-Face (Material: 18ga. CRS) RU Height Vented Width () Height () Panel Opening (C) 51 DK-CZ-51U24 22.56" 92.93" 16.21" 47 DK-CZ-47U24 22.56" 85.93" 16.21" 44 DK-CZ-44U24 22.56" 80.68" 16.21" 42 DK-CZ-42U24 22.56" 77.18" 16.21" Flush (Material: 18ga. CRS) RU Height Solid Insert Vented Width () Height () Panel Opening (C) 51 DK-FS-51U24 DK-FZ-51U24 19.53" 90.37" 14.04" 47 DK-FS-47U24 DK-FZ-47U24 19.53" 83.37" 14.04" 44 DK-FS-44U24 DK-FZ-44U24 19.53" 78.12" 14.04" 42 DK-FS-42U24 DK-FZ-42U24 19.53" 71.12" 14.04" Note: Solid inserts fit within the C dimensions of the flush flat and french doors. French- Flush (Material: 18ga. CRS) RU Height Solid Insert Vented Width () Height () Panel Opening (C) 51 DFK-FS-51U24 DFK-FZ-51U24 19.53" 90.37" 6" 47 DFK-FS-47U24 DFK-FZ-47U24 19.53" 83.37" 6" 44 DFK-FS-44U24 DFK-FZ-44U24 19.53" 78.12" 6" 42 DFK-FS-42U24 DFK-FZ-42U24 19.53" 71.12" 6" Note: Solid inserts fit within the C dimensions of the flush flat and french doors. Note: For 29 width, change 24 to 29 in part number. (i.e. DK-CZ-51U24 becomes DK-CZ-51U29) lso add 5 to width () and panel opening (C). For 32 width, change 24 to 32 in part number. (i.e. DK-CZ-51U24 becomes DK-CZ-51U32) lso add 8 to width () and panel opening (C). Note: For 29 width, change 24 to 29 in part number. (i.e. DK-CZ-51U24 becomes DK-CZ-51U29) lso add 5 to width () and panel opening (C). For 32 width, change 24 to 32 in part number. (i.e. DK-CZ-51U24 becomes DK-CZ-51U32) lso add 8 to width () and panel opening (C). Note: For 29 width, change 24 to 29 in part number. (i.e. DK-FS-51U24 becomes DK-FS-51U29) lso add 5 to width () and panel opening (C). For 32 width, change 24 to 32 in part number. (i.e. DK-FS-51U24 becomes DK-FS-51U32) lso add 8 to width () and panel opening (C).. 38 MCO Enclosures TitanDT Catalog

See Side Panels section on page 14 Technical - Side Panels Side Panel Cable Management Side Panel with Levelers Side Panel (Material: 18ga. CRS) RU Height 36 Depth ( 30.79 ) 42 Depth ( 36.79 ) 45 Depth ( 39.79 ) 48 Depth ( 42.79 ) Overall Height () 51 SPK-FS-51U-36 SPK-FS-51U-42 SPK-FS-51U-45 SPK-FS-51U-48 90.5" 47 SPK-FS-47U-36 SPK-FS-47U-42 SPK-FS-47U-45 SPK-FS-47U-48 83.5" 44 SPK-FS-44U-36 SPK-FS-44U-42 SPK-FS-44U-45 SPK-FS-44U-48 78.25" 42 SPK-FS-42U-36 SPK-FS-42U-42 SPK-FS-42U-45 SPK-FS-42U-48 74.75" Cable Management Side Panel (Material: 18ga. CRS) RU Height 36 Depth ( 34.79 ) 42 Depth ( 40.79 ) 45 Depth ( 43.79 ) 48 Depth ( 46.79 ) Overall Height () 51 TPS-51U-36 TPS-51U-42 TPS-51U-45 TPS-51U-48 95.7 47 TPS-47U-36 TPS-47U-42 TPS-47U-45 TPS-47U-48 88.7 44 TPS-44U-36 TPS-44U-42 TPS-44U-45 TPS-44U-48 83.4 42 TPS-42U-36 TPS-42U-42 TPS-42U-45 TPS-42U-48 79.9 MCO Enclosures TitanDT Catalog 39

See Mounting Channels section on page 16 Technical - Mounting Channels D D C C MCX Profile MCW Profile Reducer MCL1 Profile Reducer- 1U Device MCW Profile Reducer- 1RU or 2RU Finger Channels MCX Profile (Material: 12ga. CRS) RU Height Part Number Width () Height () 51 MCX-TN-S-51U 1.56" 89.31" 47 MCX-TN-S-47U 1.56" 82.31" 44 MCX-TN-S-44U 1.56" 77.06" 42 MCX-TN-S-42U 1.56" 73.56" MCW Profile Reducer- 1RU Fingers (Material: 12ga. CRS) RU Height Part Number Width () Height () 51 MCW-TN-S-F51U-1 4.1" 89.31" 47 MCW-TN-S-F47U-1 4.1" 82.31" 44 MCW-TN-S-F44U-1 4.1" 77.06" 42 MCW-TN-S-F42U-1 4.1" 73.56" Note: Depth of fingers is 9.25. For 2RU fingers, change 1 to 2 in part number (i.e. MCW-TN-S-F51U-1 becomes MCW-TN-S-F51U-2) MCW Profile Reducer (Material: 12ga. CRS) RU Height Part Number Width () Height () Opening Height (C) Opening Width (D) 51 MCW-TN-S-51U 4.1" 89.31" 5" 1.5" 47 MCW-TN-S-47U 4.1" 82.31" 5" 1.5" 44 MCW-TN-S-44U 4.1" 77.06" 5" 1.5" 42 MCW-TN-S-42U 4.1" 73.56" 5" 1.5" Note: For 32 width, add 32- in part number after S-. (i.e. MCW-TN-S-51U becomes MCW-TN-S-32-51U) lso add 1.5 to Width (). MCL1 Profile Reducer- 1U Device (Material: 12ga. CRS) RU Height Part Number Width () Height () Opening Height (C) Opening Width (D) 51 MCL1-TN-S-P51U 4.1" 89.31" 17.75 1.75 47 MCL1-TN-S-P47U 4.1" 82.31" 17.75 1.75 44 MCL1-TN-S-P44U 4.1" 77.06" 17.75 1.75 42 MCL1-TN-S-P42U 4.1" 73.56" 17.75 1.75 Note: For 32 width, add 32- in part number after S-. (i.e. MCL1-TN-S-P51U becomes MCL1-TN-S-32-P51U) lso add 1.5 to Width (). 40 MCO Enclosures TitanDT Catalog

See Top Panels section on page 18 Technical - Top Panels 10 6.50 6.50 3 3 19 3 6.50 Solid Vented Cover Plate 16 10 5 19 3 36 Depth - 22 42 Depth - 28 45 Depth - 31 48 Depth - 34 6.50 5 5 rush Strip Dual rush Strip 24 Width (Material: 16ga. CRS) Solid Vented Cover Plate rush Strip Dual rush Strip Width () Depth () TP-FS-24-48 TP-FV-24-48 TP-FC-24-48 TP-F-24-48 TP-FD-24-48 19.46 46.46 TP-FS-24-45 TP-FV-24-45 TP-FC-24-45 TP-F-24-45 TP-FD-24-45 19.46" 40.46" TP-FS-24-42 TP-FV-24-42 TP-FC-24-42 TP-F-24-42 TP-FD-24-42 19.46" 37.46" TP-FS-24-36 TP-FV-24-36 TP-FC-24-36 TP-F-24-36 TP-FD-24-36 19.46" 31.46" 29 Width (Material: 16ga. CRS) Solid Vented Cover Plate rush Strip Dual rush Strip Width () Depth () TP-FS-29-48 TP-FV-29-48 TP-FC-29-48 TP-F-29-48 TP-FD-29-48 24.46 46.46 TP-FS-29-45 TP-FV-29-45 TP-FC-29-45 TP-F-29-45 TP-FD-29-45 24.46" 40.46" TP-FS-29-42 TP-FV-29-42 TP-FC-29-42 TP-F-29-42 TP-FD-29-42 24.46" 37.46" TP-FS-29-36 TP-FV-29-36 TP-FC-29-36 TP-F-29-36 TP-FD-29-36 24.46" 31.46" 32 Width (Material: 16ga. CRS) Solid Vented Cover Plate rush Strip Dual rush Strip Width () Depth () TP-FS-32-48 TP-FV-32-48 TP-FC-32-48 TP-F-32-48 TP-FD-32-48 27.46 46.46 TP-FS-32-45 TP-FV-32-45 TP-FC-32-45 TP-F-32-45 TP-FD-32-45 24.46" 40.46" TP-FS-32-42 TP-FV-32-42 TP-FC-32-42 TP-F-32-42 TP-FD-32-42 24.46" 37.46" TP-FS-32-36 TP-FV-32-36 TP-FC-32-36 TP-F-32-36 TP-FD-32-36 24.46" 31.46" MCO Enclosures TitanDT Catalog 41

See Vertical Cable Management section on page 26 Technical - Cable Raceways Cable Raceway Kit Cable Raceway Kit without ack Panel Spacer Panel Cable Raceway Kits - 1RU or 2RU Fingers with ack Panel RU Height 6" Width () 8"Width () Height () 51 VCTK-51U6-1U-VD VCTK-51U8-1U-VD 95.62" 47 VCTK-47U6-1U-VD VCTK-47U8-1U-VD 88.62" 44 VCTK-44U6-1U-VD VCTK-44U8-1U-VD 83.37" 42 VCTK-42U6-1U-VD VCTK-42U8-1U-VD 79.87" Cable Raceway Doors ack Panel ack Panel with Fingers Note: For 2RU fingers, change 1 to 2 in part number. (i.e. VCTK-51U6-1U-SD becomes VCTK-51U6-2U-SD) For solid doors, change VD to SD in part number (i.e. VCTK-51U6-1U-VD becomes VCTK-51U6-1U-SD) For cable raceway kit without back panel, add at end of part number (i.e. VCTK-51U6-1U-SD becomes VCTK-51U6-1U-SD-) ack Panel (Material: 14ga. CRS) RU Height 6" Width () 8"Width () Height () 51 VCTS-51U6 VCTS-51U8 95.62" 47 VCTS-47U6 VCTS-47U8 88.62" 44 VCTS-44U6 VCTS-44U8 83.37" 42 VCTS-42U6 VCTS-42U8 79.87" Note: For back panel with fingers, change VCTS to VCTF in part number. lso add -1 or -2 after RU size in part number for finger size. (i.e. VCTS-51U6 becomes VCTF-51U-1-6) Spacer Panel (Material: 14ga. CRS) RU Height 6" Width () 8"Width () Height () 51 VCTS-51U-6 VCTS-51U-8 95.62" 47 VCTS-47U-6 VCTS-47U-8 88.62" 44 VCTS-44U-6 VCTS-44U-8 83.37" 42 VCTS-42U-6 VCTS-42U-8 79.87" Cable Raceway Doors (Vented Door) RU Height 6" Width () 8"Width () Height () 51 VFTD-Z-51U-6 VFTD-Z-51U-8 95.62" 47 VFTD-Z-47U-6 VFTD-Z-47U-8 88.62" 44 VFTD-Z-44U-6 VFTD-Z-44U-8 83.37" 42 VFTD-Z-42U-6 VFTD-Z-42U-8 79.87" Note: For solid door, change Z to S in part number. (i.e. VCTD-Z-51U-6 would become VCTD-S-51U-6) 42 MCO Enclosures TitanDT Catalog

Technical - Cable Management 24 29 32 5 10 Overhead Cable Raceway - Material: 16ga. CRS OCT-24-10 (24 Rack Width) OCT-29-10 (29 Rack Width) OCT-32-10 (32 Rack Width) 24 29 32 5 Power/Cable Panel Cable Lacing Strip 10 Overhead Cable Raceway 1U Device - Material: 16ga. CRS OCTWC-24-10 (24 Rack Width) OCTWC-29-10 (29 Rack Width) OCTWC-32-10 (32 Rack Width) 1.75 3.50 12 5 Overhead Raceway Spacer Kit OCT-SK-6 (6 Wide) OCT-SK-8 (8 Wide) OCT-SK-10 (10 Wide) OCT-SK-12 (12 Wide) Vertical Finger racket Kit Overhead Strut Kit TSHK-12 Power/Cable Panel (Material: 14ga. CRS) RU Height 7" Width ( 7.25") 10" Width () Height () 51 PCP-51U-7 PCP-51U-10 89.31" 7.6 4RU Overhead racket Kit OP-TN-4U24 (24 Rack Width) OP-TN-4U29 (29 Rack Width) OP-TN-4U32 (32 Rack Width) 47 PCP-47U-7 PCP-47U-10 81.50" 44 PCP-44U-7 PCP-44U-10 76.25" 42 PCP-42U-7 PCP-42U-10 72.75" 3 5.6 9 Cable Lacing Strip (Material: 14ga. CRS) RU Height 5" Width () Height () 51 CLS-51U-5 86.56" 47 CLS-47U-5 79.56" 44 CLS-44U-5 74.31" 42 CLS-42U-5 70.81" Vertical Finger racket Kit -1RU & 2RU RU Height 1 RU 2 RU 51 VFK-51U-1 VFK-51U-2 47 VFK-47U-1 VFK-47U-2 44 VFK-44U-1 VFK-44U-2 42 VFK-42U-1 VFK-42U-2 MCO Enclosures TitanDT Catalog 43

See Cooling section on page 30 Technical - Cooling 17 17 35-60 8 20-35 35-60 16 Overhead Chimney Solution 14 gauge luminum (.064 Thickness) 7.31 7.42 ir Deflector Material: 18ga. CRS lanking Panel Material: 16ga. CRS Network Switch Cooling Solution Network Switch Cooling Solution - 42 Depth RU Height 6" Width () 8" Width () Height () 51RU NSCS-51U6-42 NSCS-51U8-42 95.62" 47RU NSCS-47U6-42 NSCS-47U8-42 88.62" 44RU NSCS-44U6-42 NSCS-44U8-42 83.37" 42RU NSCS-42U6-42 NSCS-42U8-42 79.87" Note: For 45 depth, change 42 to 45 in part number. (i.e. NSCS-51U6-42 becomes NSCS-51U6-45) For 48 depth, change 42 to 48 in part number. (i.e. NSCS-51U6-42 becomes NSCS-51U6-48) lanking Panel Part Number Width () Height () PT24-1U 19.56" 1.75" PT24-2U 19.56" 3.5" PT24-3U 19.56" 5.25" PT24-4U 19.56" 7" PT24-8U 19.56" 14" Overhead Chimney Solution 20-35 35-60 24" Width 24" Width TP-FD3-24-48 TP-FD6-24-48 TP-FD3-24-45 TP-FD6-24-45 TP-FD3-24-42 TP-FD6-24-42 TP-FD3-24-36 TP-FD6-24-36 Note: For 29 width, change 24 to 29 in part number. (i.e. TP-FD6-24-45 becomes TP-FD6-29-45) For 32 width, change 24 to 32 in part number. (i.e. TP-FD6-24-45 becomes TP-FD6-32-45) 44 MCO Enclosures TitanDT Catalog

Technical - ccessories See ccessories section on page 34 D C C Light Duty Shelf Drawer Heavy Duty Shelf - Solid VENTED Heavy Duty Shelf - Vented C djustable Chassis Guides Heavy Duty Shelves (Material: 14ga. CRS) Solid Vented Width () Height () Depth (C) U-SHS-1725 U-SHV-1725 19" 1.75" 17" - 25" U-SHS-2540 U-SHV-2540 19" 1.75" 25" - 40" Light Duty Shelf (Material: 16ga. CRS) Vented Width () Height () Depth (C) Usable Width (D) U-SH1 19.00" 1.75" 16.08" 17.375" U-SH2 19.00" 3.50" 16.08" 17.375" U-SH3 19.00" 5.25" 16.08" 17.375" U-SH4 19.00" 7.00" 16.08" 17.375" U-SH5 19.00" 8.75" 16.08" 17.375" Drawer (Material: 18ga. CRS) Solid with Lock Width () Height () Usable Depth (C) U-DR2-LK 19.00" 3.5" 17.50" U-DR3-LK 19.00" 5.22" 17.50" U-DR4-LK 19.00" 6.97" 17.50" djustable Chassis Guides (Material: 12ga. CRS) Part Number Width () Height () Depth C CHG-TN-2536-D 3" 1.75" 25"-36" MCO Enclosures TitanDT Catalog 45

Now vailable WMR Wall Mount Rack The WMR wall mount rack has been designed as a cost effective smaller system solution for mounting electronics equipment in secured and non-secured areas. The WMR features fully welded construction and has a load rating of 250 lbs. The WMR is 24 wide and available in depths of 17, 22 and 28, with RU height options of 12 and 18. The reversible front doors are available in solid, vented and polycarbonate. ll doors feature a keyed lock for secured access. The back panel has cutouts to accommodate electrical outlets and knockouts in the top and bottom for conduit and cabling. Two pair of fully adjustable mounting rails are included. Choice of 11 standard, durable powder coat colors. Note: Unit mounts to wall as right hand hinged, left hand option is available upon request. WMR Fan Panel Kit Fan Panel Kit WMR-FK The fan kit includes two 115V C fans, with a 4 diameter that deliver 60 CFM at 27db each. The fan kit also includes fan guards, a 5 power cord with ground, and mounting hardware. Solid Door RU Height Overall Height 17 Depth* 22 Depth* 12RU 24.25 WMRS-12U17-V WMRS-12U22-V 18RU 34.75 WMRS-18U17-V WMRS-18U22-V Polycarbonate Door RU Height Overall Height 17 Depth* 22 Depth* 12RU 24.25 WMRP-12U17-V WMRP-12U22-V 18RU 34.75 WMRP-18U17-V WMRP-18U22-V Vented Door RU Height Overall Height 17 Depth* 22 Depth* 12RU 24.25 WMRV-12U17-V WMRV-12U22-V 18RU 34.75 WMRV-18U17-V WMRV-18U22-V Note: WMR is also available in a Solid non-vented model. For Solid model, change -V to -S at the end of the part number. (i.e. WMRS-12U19V becomes WMRS-12U19S) *Front door adds 2 to overall depth dimension. 46 MCO Enclosures TitanDT Catalog

Other Products MCO Enclosures Offers Many Solutions MCO has developed a line of commercial racks for the V, security and general electronic packaging industries that can meet almost any of your design requirements. ll MCO racks are certified to EI310D. Seismic Racks Zone 4 certified racks are available in a variety of standard heights, widths and depths to meet NES GR-63-CORE specifications for seismic events. Shielded Racks RFI racks limit radiated emissions and are certified to MIL STD 285 for higher-level shielding requirements. Shielded racks are available in a variety of standard heights, widths and depths. TN Series MCO has developed a line of commercial racks for electronics packaging. These racks have a full range of heights, widths and depths for a variety of applications including media closets, security and general electronics packaging. Custom Designs MCO recognizes the need to build rack systems for customers that are not commercially available. We create specialized designs for customers that require standard off-the-shelf rack products. Contact us today at 847-391-8100 for more information. General Packaging full line of racks are available for general packaging. These racks are for electronics packaging that do not exceed 45RU in panel opening heights and frame depths of 36. an IMS Engineered Products rand TN Series General Packaging Seismic Racks Shielded Racks MCO Enclosures TitanDT Catalog 47

Warranty & Policies. Choice of Method of Shipment Unless otherwise specified, MCO Enclosures are shipped as individual modules per IST packaging certification with single width components assembled on the frame. Upon request, console arrangements will be completely assembled at the factory and shipped like furniture, via van, at no additional charge for assembly. Console arrangements may also be crated for shipment. Crating charges will be quoted for each such order, as console arrangements vary.. Design Changes To allow continued progress, improvement, and adaptability in an advancing industry, MCO Enclosures reserves the right to make product changes as deemed necessary. C. Price Discounts Purchase orders cannot be combined for discount advantages. D. Proprietary Rights The catalog and drawings contain information deemed proprietary to MCO Enclosures and are to be used only for the purposes for which they are submitted and, further, shall not be copied in whole or in part without the prior written consent of MCO Enclosures. E. Cancellation & Return Cancellation and return charges begin at 40% with a minimum of $50.00, depending on the nature of the order and the extent to which it has been processed. ll returns have a 30-day, upon receipt, time limit. Returns must be freight prepaid and not made without the prior written approval of MCO Enclosures. F. Terms ll quotations, order confirmations, published prices, and discounts based on delivery F.O.. MCO Enclosures, 1 Innovation Drive, Des Plaines, IL freight collect. Invoice payment terms-net 30 days. G. Sales Representation Experienced factory sales representatives in all principle cities of the U.S.., Canada and Mexico. sk for sales representative listing. MCO Enclosures equipment is thoroughly inspected prior to shipment. No returns of damaged equipment will be accepted without prior written approval of MCO Enclosures. Limited Warranty MCO Enclosures will repair or replace enclosures, accessories, and components manufactured by MCO Enclosures that are proven to be defective in material or factory workmanship under normal use during the Period of this Warranty. Warranty Period Ten years from date of purchase. (Non-transferable) This warranty does not cover: Failure in whole or part resulting from misuse, alteration, excessive temperature, excessive humidity, corrosive environment, or lack of maintenance. ny materials or components used or manufactured pursuant to the purchaser s specifications. Items ordered in error or not required. Power/ccessories Warranty as specified by manufacturer. Warranty Repair Purchaser shall obtain controlled authorization number before returning any items alleged to be defective to MCO Enclosures. Inspection MCO Enclosures shall have the right to inspect any and all allegedly defective items on-site at purchaser s convenience. Disclaimer of Consequential Damages and Limitations of Implied Warranty MCO Enclosures disclaims any responsibility for loss of time or use of parts or equipment wherein MCO Enclosures, components, or accessories are used, transportation or any other incidental or consequential damage; and any implied Warranties including the implied Warranty of merchantability and fitness for intended use are limited to the duration of this written warranty. Designed and Manufactured in the US IMS Engineered Products is Certified 1 Innovation Drive Des Plaines, IL 60016 www.amcoenclosures.com 847-391-8100 013017