MD-N32 Serial to Ethernet Gateway Installation and Operating Guide

Similar documents
CS-CCT Configuration Card Tool for the DR-6255 Software Manual

AxTime Attendance Control System Software Manual

AY-Bx660 Family Full Fingerprint Match-on-Card Readers Installation Manual. Models: AY-B1660 AY-B2660

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

AY-V64B Multi-Reader Installation and Programming Manual

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN

AC-225x-B Series. Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual. Models:

Wireless Access Control Door Interface Installation Manual MD-W11F

AC-825IP Networked Controller Hardware Installation and User Guide

AC-225x Family Advanced Scalable Networked Access Controller Hardware Installation Manual

2012 December. AY-Q64 Anti-Vandal PIN & Proximity Reader Installation and Programming Manual

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AY-W6x60 Family MIFARE Contactless Smart Card / Sector Readers Installation and Programming Manual. Models: AY-W6260 AY-W6360

GS-01 DigiTool Reports Lite Software Manual

AC-S/T43 Family Anti-Vandal Piezoelectric PIN Standalone Controller Installation and Programming Manual

AC-525 Video Integrated Networked Access Controller Hardware Installation Manual

SA-59. GSM Communicator. Installation Manual

AC-225. Advanced Scalable Networked Access Controller. Hardware Installation and User Guide

Long range Multi Reader AY-Z12A Installation Guide

2013 May. AxTraxNG Access Control Management Software Software Manual (Version 22.x)

Serial to Ethernet Converter

VeriCard. Card Badging Module Software Guide

Lantronix UDS-10 (CoBox) w/sielox Firmware B03.54 or greater Set-up, Installation, and FAQ Notes

AxTraxNG Access Control Management Software Software Manual (Version 27.x)

AxTraxNG Access Control Management Software Software Manual (Version 27.x)

DATASHEET 4D SYSTEMS TURNING TECHNOLOGY INTO ART. microusb Programming Adaptor. USB to UART Serial Bridge

AY-H6355BT CSN SMART Smart Card Readers (Rev. A) Installation and User Manual BLE 4.1

AIM- DAC System. DAC844 User Manual. Anviz Global Inc

USR-TCP Hard version: V2.0 File version: V

USB Server User Manual

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

WIZ220IO / WIZ220IO-EVB User s Manual (Ver. 1.0)

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

DATASHEET 4D SYSTEMS TURNING TECHNOLOGY INTO ART. USB to Serial UART Bridge Converter. Document Date: 5 th September 2012 Document Revision: 1.

DATASHEET 4D SYSTEMS. uusb-pa5 uusb-pa5-ii. microusb Programming Adaptor TURNING TECHNOLOGY INTO ART. USB to UART Serial Bridge

RS-232/422/485 Over IP Adapter

Tel: Fax:

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

Touch Screen. Bergquist. User s Guide. Set-Up and Use of Bergquist 5-Wire Controller USB, RS-232, & PS/2 TOUCH SCREEN CONTROLLER FEATURES

All the registered trademarks referred to this manual are belonging to their respective companies.

LAN9512 Evaluation Board User Manual

MOXA VPort 2110/2140/2141 Video Server Quick Installation Guide

SST Automation

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

STEVAL-PCC010V1. ST802RT1A Ethernet PHY demonstration board with STM32F107 controller add-on board. Features. Description

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

Canlan INSTALLATION MANUAL

TRP-C37 User s Manual

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

For the LAN91C111 TQFP package, the Vdd and AVdd pins are located as follows: Pin #1, #11, #16, #33, #44, #62, #77, #98, #110, #120.

SERIAL TO ETHERNET CONVERTER E-P User Manual

Redirector User Guide

GW-7472 / GW EtherNet/IP to Modbus RTU/TCP Gateway User Manual

User Manual C1AP-100. Industrial Ethernet Protocol Analyzer

UM0792 User manual. Demonstration firmware for the DMX-512 communication protocol transmitter based on the STM32F103Zx.

OnCell G3100 Series Quick Installation Guide

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

AC-215. Single and Double Door Access Control Unit Hardware Installation Guide

DATASHEET 4D SYSTEMS. 4D Arduino Adaptor Shield TURNING TECHNOLOGY INTO ART. 4Display-Adaptor-Shield

Operation Manual of EX9132CST-Series

iomirror E3210 User s Manual

NE-4100-P Series User s Manual

User s Guide. Ethernet Module for Barcode Printer

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

HDMI-IP-E/R User Manual v1.3

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

ELK-IP232 INSTALLATION AND CONFIGURATION MANUAL. Ethernet to Serial Bridge

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

MEC-LAN-M002. User s Manual

Infosystem. User Manual. Version 1.0. Serial to Ethernet Converter with 3 sockets. Infosystem Technology Corporation, Ltd.

Megabit Modem MM300S INSTALLATION GUIDE

All Rights Reserved. February 2005 Version 1.1

Moxa Remote Connect Gateway User s Manual

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

AxTraxNG Access Control Management Software Software Manual (Version 26.x)

DATASHEET 4D SYSTEMS. 4D Raspberry Pi Serial Adaptor TURNING TECHNOLOGY INTO ART. 4D-Serial-Pi-Adaptor

ASUS SpaceLink Access Point WL-300. Quick Start Guide

WIZ107SR User Manual

SSE232-LE Serial Server- User s Manual

If WPA-PSK is selected, please set the PSK key in the pass phrase field. The pass phrase should be 8 characters at least.

LAN9303 Evaluation Board User Manual

Ethernet to J1939 Installation Guide AB7665. Part no. SP0863 Rev. 1.01

ecov-110 User s Manual (V0.9f_Eng)

DATASHEET 4D SYSTEMS. 4D Raspberry Pi Serial Adaptor TURNING TECHNOLOGY INTO ART. 4D-Serial-Pi-Adaptor

MEC-COM-M114. User s Manual

Video Recording Transmitter. Installation Guide

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

DATASHEET 4D SYSTEMS. 4D Raspberry Pi Serial Adaptor TURNING TECHNOLOGY INTO ART. 4D-Serial-Pi-Adaptor

Nokia Intrusion Prevention with Sourcefire. Appliance Quick Setup Guide

VENUS_ Driving Board and 39.6 Prism Display

x10data Smart Client 7.0 for Windows Mobile Installation Guide

MEC-COM-M154. User s Manual

EVB-USB2517 Evaluation Board User Manual (Revision A)

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

EEG ComCC 1250m Modem Data Multiplexer

HouseLink HL-10E. Installation and Operation Manual Modbus TCP and XML

Transcription:

MD-N32 Serial to Ethernet Gateway Installation and Operating Guide

Copyright 2014 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information. No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE. ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual. TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS. The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE. ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.

Table of Contents Table of Contents 1. Introduction... 7 2. Specifications... 8 3. Connection and Configuration... 9 3.1 Hardware Requirements... 9 3.2 Software Requirements... 9 3.3 Connecting the MD-N32... 9 3.3.1 Network Connection... 10 3.3.2 Serial Connection... 10 3.3.3 Power Connection... 11 3.3.4 Network Connection Diagram... 11 3.4 Configuring the AS-IP01... 11 3.4.1 MAC Address Table... 12 3.4.2 Buttons... 13 3.4.3 Network Section... 13 3.4.4 Device Type... 14 3.4.5 Serial Speed... 14 3.4.6 Options Section... 14 3.4.7 Status... 15 3.5 Configuring the MD-N32... 15 A. Limited Warranty... 18 MD-N32 Installation and Operation Manual iii

List of Figures List of Figures Figure 1: Front View of the MD-N32... 10 Figure 2: Rear View of the MD-N32... 10 Figure 3: TCP/IP Network Connection... 11 Figure 4: AS-IP01 Configuration Utility GUI... 12 Figure 5: AS-IP01 Configuration Utility Search Button Results... 16 iv MD-N32 Installation and Operation Manual

List of Tables List of Tables Table 1: AS-IP01 Configuration Utility Buttons... 13 Table 2: Network Section Fields... 13 MD-N32 Installation and Operation Manual v

Notice and Disclaimer Notice and Disclaimer This manual s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein. BEFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND THE USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING PROCEDURES. The system must not be used for purposes other than those for which it was designed. The use of the software associated with the system and/or product, if applicable, is subject to the terms of the license provided as part of the purchase documents. ROSSLARE exclusive warranty and liability is limited to the warranty and liability statement provided in an appendix at the end of this document. This manual describes the maximum configuration of the system with the maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased. Incorrect operation or installation, or failure of the user to effectively maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury. The text, images and graphics contained in the manual are for the purpose of illustration and reference only. All data contained herein subject to change without prior notice. In no event shall manufacturer be liable for any special, direct, indirect, incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury). All graphics in this manual are for reference only, some deviation between the image(s) and the actual product may occur. All wiring diagrams are intended for reference only, the photograph or graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s). vi MD-N32 Installation and Operation Manual

Introduction 1. Introduction The MD-N32 is a Serial to Ethernet Gateway. One MD-N32 unit is required (unless it is connected to a Rosslare software product that supports direct TCP/IP operation, in which case the PC's internal LAN card may be used). A Serial to Ethernet Gateway allows connectivity for systems with Legacy serial interface communication, such as RS-232 or RS-485, with local networks and Internet. The concept is to send and receive information between varied PCmanaged products (access control systems, guard control, security systems, and so on) via a local network or Internet, thereby saving on serial cabling installation, and enabling connections to remote sites (most modern offices are already networked). As a compact plug-in module, the MD-N32 can easily connect to most products without modification. The module receives serial communication, converts it to TCP/IP format, and sends it over the LAN or Internet to the PC. From the other end, the module converts communications sent from the PC over the network back to serial format into the device. All the setting and configuration is done using the AS-IP01 Configuration Utility PC software or by other Rosslare software that supports a direct connection to hardware through TCP/IP (refer to the software manuals of the specific products.) Once the module is configured, the information is saved in a non-volatile memory within the module. The MD-N32 has two indication LEDS the green LED indicates LAN connectivity (Link) and the red LED indicates power supply operation (Power). MD-N32 Installation and Operation Manual 7

Specifications 2. Specifications Electrical Characteristics Input Power 10 to 16 VDC Power Consumption Typical: 75 ma Maximum: 115 ma Transmission and Connectivity Characteristics Hardware Protocols Network Interface Serial Port Data MCU Serial Line Format Serial Flow Control Transmission Speed TCP, UDP, IP, ARP, ICMP, Ethernet MAC 10/100 Base-T Ethernet (Auto Detection) RJ- 45 jack for LAN connection D9 Male Connector RS-232 1, 4, 6, 7, 8, 9 N.C. 2 Rx 3 Tx 5 GND Signal 32 bit micro-controller 8-N-1, 8-O-1, 8-E-1, 7-O-1, 7-E-1 None, XON/XOFF Environmental Characteristics Operating Temp. Range 1200 bps to ~115 Kbps 0 C to 70 C (32 F to 158 F) Operating Humidity Range 10 to 90% (non-condensing) Dimensions Height x Width x Depth Weight 110 x 63 x 39 mm (4.33 x 2.48 x 1.54 in.) 92 g (3.25 oz) 8 MD-N32 Installation and Operation Manual

Connection and Configuration 3. Connection and Configuration 3.1 Hardware Requirements The following are the hardware units required to connect the MD- N32 to the remote unit. Standard LAN cables RJ-45 plugs on both sides 12 VDC (400 ma) power adaptor, connected to the unit's DC jack MD-14 RS-485 to RS-232 Converter (for RS-485 units or RS-232 cable) 3.2 Software Requirements The following are the requirements for the software installation of the AS-IP01 Configuration Utility PC software. Your PC configuration must be able to support one of the following operating systems: Windows 98/ME Windows NT/2000/XP One of the above operating systems must be installed on your computer. The PC must have a LAN network connection to configure the MD- N32. Both the PC and external unit must be connected to the same LAN through a hub. It is also possible to use the MD-N32 over a WAN, but this requires network router settings. (It is recommended that system administrators be responsible for setting network routers.) 3.3 Connecting the MD-N32 Before setting, ask your network administrator for an IP address, ports, and subnet masks for each MD-N32. MD-N32 Installation and Operation Manual 9

Connection and Configuration 3.3.1 Network Connection Connect each MD-N32 to the LAN using the LAN cables through the RJ-45 connector on each unit of the MD-N32 (Figure 1). Figure 1: Front View of the MD-N32 Power Jack RJ-45 Jack Make sure that the units are connected to the same LAN through a hub. 3.3.2 Serial Connection 3.3.2.1 Unit Side Connect the unit to the MD-N32 D9 jack using an RS-232 cable (Figure 2), or use Rosslare's MD-14 when necessary (RS-485 to RS-232 Converter). Figure 2: Rear View of the MD-N32 D9-RS-232 Jack 3.3.2.2 PC Side If the MD-N32 is connected to the PC s serial port, connect the MD- N32's D9 jack to the PC using a cross-linked RS-232 cable. 10 MD-N32 Installation and Operation Manual

Connection and Configuration 3.3.3 Power Connection Connect a 12 VDC (200 ma) power adaptor to each MD-N32 unit. Ensure that the MD-N32 Power LED is on. 3.3.4 Network Connection Diagram Figure 3 shows the network connection using an MD-N32 and PC network card. Figure 3: TCP/IP Network Connection TCP/IP Network 3.4 Configuring the AS-IP01 Once you have installed the AS-IP01 Configuration Utility according to the installation's automated steps, the GUI appears as shown in Figure 4. MD-N32 Installation and Operation Manual 11

Connection and Configuration Figure 4: AS-IP01 Configuration Utility GUI The AS-IP01 Configuration Utility includes the following features: A MAC address table in the left pane Network, Modes, Device Type, Serial, and Options sections in the right pane Search, Apply, About, and Exit buttons in the bottom left pane Each section of the AS-IP01 Configuration Utility and its parameters are labeled in Figure 4. An explanation of each section and parameter is provided in the following subsections. 3.4.1 MAC Address Table 3.4.1.1 MAC Address When the MD-N32 units connected to the network are found, the units are displayed as MAC addresses in the table. The MAC number is a long 12-digit number that can be found on a sticker located on the bottom side of the MD-N32 unit. 12 MD-N32 Installation and Operation Manual

Connection and Configuration 3.4.1.2 Version The MD-N32 firmware version is displayed. 3.4.2 Buttons Table 1 presents the buttons that appear in the AS-IP01 Configuration Utility. Field Search Apply About Exit Table 1: AS-IP01 Configuration Utility Buttons Description Clicking Search retrieves all operating MD-N32 units connected to the network. The results are displayed as MAC addresses in the table. Clicking Apply changes the configuration of the selected MD-N32 unit; the selected unit is initialized with the newly entered values. Clicking About displays the details of the AS-IP01 Configuration Utility. Clicking Exit exits the software 3.4.3 Network Section Once a unit is selected in the MAC Address table, the network information of the selected unit is displayed in this section. You can change the network configuration of the unit by inserting and/or revising the information in the following parameters of the Network section. Table 2 presents the fields in the Network section. Table 2: Network Section Fields Field Local IP and Local Port Subnet Gateway Server IP and Server Port Description The IP address of the unit The subnet address of the unit The gateway address Defines the server's IP and port when the unit is set to operate in Client mode MD-N32 Installation and Operation Manual 13

Connection and Configuration Field Modes Description The network mode of operation: Client mode Unit operates in Client mode and attempts to connect to the specified server's IP address and port Server mode Unit operates in Server mode and listens in on the specified Listen port and awaits client connection In Client mode, the inactivity time should be set above 30 seconds (the default is 45 seconds). In Server mode, the inactivity timer of the server is set to 0 by default. The client closes and restarts the socket every 45 seconds. When the server is reset, the link between the client and the server is resumed after 45 seconds. While data transfer may fail when the socket is restarted, the transfer should be successful the next time the socket is restarted. Data transfer does not fail as long as keep alive data is maintained in the TCP socket. A socket connection should be in place when the data is sent from a serial device. If not, a connection may be initiated to the server IP and port, and the data may then be resent. 3.4.4 Device Type This section contains the name of the product (MD-N32). 3.4.5 Serial Speed This section lists the product s speed, which can be configured as desired. Click Apply for any changes in the device type or serial speed to take effect. 3.4.6 Options Section The Options section includes the following parameters: 14 MD-N32 Installation and Operation Manual

Connection and Configuration 3.4.6.1 Inactivity Time The inactivity time is intended for use with the TCP channel when a link is established. If the inactivity timer has expired, the channel is closed to data transfer. Data transfer resumes once the MD-N32 has been set to the client. The inactivity timer range may be 0 (the default, TCP channel is always ON) or from 30 to 65,535 seconds. 3.4.6.2 Data Packing This options allows you to designate conditions for Serial to Ethernet data transmission. The two conditions are Time and Size, with Time packing as the default. Time Designates a time frame for periodic transmission, between 0 and 10,000 milliseconds. Size Select the checkbox to enable the size packing feature, and then designate the data size for transmission based on data packet size, between 10 and 255 bytes. After changes are made, click Apply for the changes to take effect. 3.4.7 Status The Status describes the status of the selected MAC (for example, Configured). 3.5 Configuring the MD-N32 To configure the MD-N32: 1. Run the AS-IP01 Configuration Utility PC software. 2. Click Search. The Processing window appears. 3. When the search is complete, ensure that the correct MD-N32 MAC addresses appear in the MAC Address table (Figure 5). MD-N32 Installation and Operation Manual 15

Connection and Configuration Figure 5: AS-IP01 Configuration Utility Search Button Results It is not possible to run two sets of AS-IP01 simultaneously on the same PC or on the same network. It is also not recommended that AS-IP01 be run simultaneously with some software applications either based on Microsoft Visual Basic 6 or featuring TCP/IP support, since the AS-IP01 may malfunction. For example, it is not recommended to run AS-IP01 on the same PC and at the same time as Rosslare s AxTraxNG software. 4. Select the MAC Address of the MD-N32 unit that is connected to the applicable networked unit. 5. In the Network section, in the Local IP and Local Port text boxes, enter the first IP Address and port number (1000 recommended) supplied by your network administrator. 6. In the Subnet text box, enter the supplied subnet. 7. In the Server IP text box, enter the second IP address and port number (1000 recommended). 8. In Modes, select either Client or Server, as required. 16 MD-N32 Installation and Operation Manual

Connection and Configuration 9. Click Apply to send the configuration to the unit. 10. Run the applicable application software for the networked unit. MD-N32 Installation and Operation Manual 17

Limited Warranty A. Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com. Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them. 18 MD-N32 Installation and Operation Manual

MD-N32 Asia Pacific, Middle East, Africa Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 support.apac@rosslaresecurity.com United States and Canada Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com Europe Rosslare Israel Ltd. Rosh HaAyin, Israel Tel: +972 3 938-6838 Fax: +972 3 938-6830 support.eu@rosslaresecurity.com Latin America Rosslare Latin America Buenos Aires, Argentina Tel: +54-11-4001-3104 support.la@rosslaresecurity.com China Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86 755 8610 6842 Fax: +86 755 8610 6101 support.cn@rosslaresecurity.com India Rosslare Electronics India Pvt Ltd. Tel/Fax: +91 20 40147830 Mobile: +91 9975768824 sales.in@rosslaresecurity.com 0706-0960055+02