MST2000 Loop Powered Multivariable SMARTFLOW Transmitter
MST2000 Loop Powered Multivariable SMARTFLOW Transmitter Brandt Instruments MST2000 Series Loop Powered Multivariable SMARTFLOW Transmitter sets new standards for draft range Differential Pressure / Mass Flow measurement of Air and Gas Flows. Combining Brandt s twenty plus years of experience in industrial process control with state of the art digital signal processing technology, the MST2000 is the most versatile, reliable, cost-effective and simplest to operate loop powered multivariable transmitter in the industry. The MST2000 is a HART compatible, loop powered (two wire ) device available in either a compact, NEMA 1 configuration for wall or panel mounting or a rugged fiberglass NEMA 4X enclosure for hostile environments. With a turndown capability of 10:1 the available draft ranges can be turned as low as 0.01 Inches W.C. full scale. Fully programmable and user friendly, the MST2000 is capable of producing and displaying signals for Differential Pressure (Inches of Water Column) or for Flow (ACFM, SCFM, Lb/Hr). Optional isolated 4-20 ma inputs are available for Absolute Pressure, External Temperature and a second Differential Pressure Transmitter. A HART Communications Module and Digital I/O Module are also available. All the optional modules can be installed in the field by the end user. MST2000 Standard Features High Performance at Ultra Low Spans: Standard spans from 0.10 to 50 Inches Water Column are available (custom and compound ranges are also possible) with a total accuracy of 0.15% of Span. Thermal Compensated Output: Each MST2000 has an onboard temperature sensor and is thermally compensated at the factory to eliminate thermal effects. Password Protection: The MST2000 provides for password security so that modifications to program variables can only be made by authorized personnel. Adjustable Damping: The standard time constant is 500 msec but is user programmable from 0.5 to 5 seconds in 0.5 second intervals. LCD Display and Integral Keypad: A large, high contrast, easy to read LCD display and integral keypad allow the user to effortlessly program the MST2000 for optimal process conditions. Programmable Alarms: User selectable transmitter fault conditions can be programmed to set the 4-20 ma output to a low 3.9 ma or high 21.0 ma state. User can also select HI/LO process conditions to control the optional digital outputs. RTD Input: A non-isolated 4 wire RTD input connection is supplied for external temperature input. Integral Test Jack: Allows the user to monitor the ma output of the MST2000 without disconnecting the loop. Programmable Constants: When external temperature and absolute pressure signals are unavailable, these variables can be programmed in as constants, allowing the end user to select an output signal which will represent ACFM, SCFM or Lb/Hr. Without these constants, or external inputs, only the D.P. will be a true signal. MST2400: NEMA 4X Enclosure MST2000 Isolated Input Modules The MST2000 can be optionally configured with up to three (3) Isolated 4-20 ma input modules for true mass flow measurement. The input range for each input module is software rangeable by the end user. Any combination of the three can be mounted at the factory or field mounted by the user to upgrade process capabilities. Temperature Input Option: Accepts a 4-20 ma input from an external temperature transmitter. Absolute Pressure Input Option: Accepts a 4-20 ma input from an external absolute pressure transmitter. An optional integral absolute pressure transmitter can be mounted in the MST2400 enclosure. External Differential Pressure Input Option: Accepts a 4-20 ma input from an external differential pressure transmitter. A second differential input can be used to extend the available range to provide up to 2% flow rate accuracy over a 25:1 flow range. MST2000 Digital I/O Module The MST2000 can be optionally configured with (1) one digital input and (2) two digital outputs. This option is capable of either being installed at the factory or in the field. Digital Input: Accepts external signal to trigger events, such as a blowdown sequence. The MST2000 will hold the last output signal throughout the duration of the event. Digital Outputs: For control of external devices (AutoZero Valve, High Pressure Blowdown Systems, Alarm Circuits, etc.). HART Communications Module An optional HART Communication Module can be installed to provide industry standard HART access to the MST2000. This option can be installed at the factory or in the field.
Brandt Instruments, Inc., Fuquay, North Carolina 27526 USA (919) 552-9011 www.brandtinstruments.com MODE EDIT Run Alarm ABS. PRES. STATUS STATUS STATUS EXT. TEMP. Brandt Instruments, Inc. Fuquay, North Carolina USA LOOP+ LOOP- RTD+ SEN+ SEN- RTD- +EXTIN 1- +EXTIN 2- +EXTIN 3- +DI1- + DO1- +DO2- RX/TX+ GNDRX/TX- TM Auto Zero Blowdown EXT. DP Brandt Instruments, Inc., Fuquay, North Carolina 27526 USA (919) 552-9011 www.brandtinstruments.com Model: MST2111002S1P 4-20mA Loop Powered Serial Number: 2002001 Range: 0 to 0.25 Inches W.C Abs.Prs Temp. ExtDP LOOP RTD SEN SEN RTD EXTIN 1 EXTIN 2 EXTIN 3 DI 1 DO 1 DO 2 RX/TX INC. DEC. Brandt Instruments, Fuquay, North Carolina 27526, USA (919) 552-9011 Dimensions 2.33 Inches 59.2 mm 6.25 Inches 158.8 mm 6.75 Inches 171.5 mm TM MST2000 Multivariable SMARTFLOW Transmitter MODE INC. 7.0 Inches 177.8 mm EDIT Run Alarm 0.250 - INWC DEC. Auto Zero Blowdown 6.5 Inches 165.1 mm _TEST + ABS. PRES. STATUS STATUS STATUS Model: MST2111002S1P Serial Number: 2002001 EXT. TEMP. Brandt Instruments, Inc. Fuquay, North Carolina USA 4-20mA Loop Powered Range: 0 to 0.25 Inches W.C EXT. DP + + + Abs.Prs + + Temp. + ExtDP + _ + _ + _ + _ LOOP RTD SEN SEN RTD EXTIN 1 EXTIN 2 EXTIN 3 DI 1 DO 1 DO 2 RX/TX LCD Display & Integral Keypad HI LOW 1/8"NPTF Process Connections Bottom View LOOP+ LOOP- RTD+ SEN+ SEN- RTD- +EXTIN 1- +EXTIN 2- +EXTIN 3- +DI1- + DO1- +DO2- RX/TX+ GNDRX/TX- HI LOW Status Light & Resets for Isolated Input Options Side View Test Jacks Top View 0.25 Inch (6.35mm) Dia. Mounting Holes (4X) MST2100: NEMA 1 Enlcosure Top View 0.25 Inch Dia. Mounting Holes (4X) 7.688 Inches 195.3 mm 6.125 Inches 155.6 mm MST2000 Multivariable SMARTFLOW Transmitter 0.250 - INWC 9.188 Inches 233.4mm 9.688 Inches 246.1 mm _TEST + + + + + + + + + + + 11.188 Inches 284.2 mm Brandt MST24111002S1P Serial No:20002001 0 to 0.25 INWC 4-20 ma Loop Powered Output Signal HI LOW 1/2" Conduit Connection Bottom View Window 1/4"NPTF Process Connections Located on MST2000 Front View Recessed Captive Screws Optional 2.5" Pipe Mount Side View With Optional 2.5" Pipe Mount MST2400: NEMA 4X Fiberglass Enclosure
SERIES: LOOP POWERED MULTIVARIABLE SMARTFLOW TM TRANSMITTER MST2000 Model Number Description MST21 = MST2100, NEMA 1 Panel Mount Enclosure, Differential Pressure Configuration & Non-isolated 4 Wire RTD Input Standard. MST24 = MST2400, NEMA 4X, Fiberglass Enclosure, Differential Pressure Configuration & Non-isolated 4 Wire RTD Input Standard. ISOLATED INPUT MODULE: Absolute Pressure Transmitter 0 = None 1 = Isolated Input Module: Accepts 4-20mA input signal from an External Absolute Pressure Transmitter. 2 = Isolated Input Module with Integral Absolute Pressure Transmitter, 0-25 PSI range standard. Consult factory for other ranges. MST2400 only. Requires external 24V source. ISOLATED INPUT MODULE: Temperature Transmitter 0 = None 1 = Isolated Input Module: Accepts 4-20mA input signal from an External Temperature Transmitter. ISOLATED INPUT MODULE: 2 nd Differential Pressure Transmitter 0 = None 1 = Isolated Input Module: Accepts 4-20mA input signal from a 2 nd External D.P. Transmitter. COMMUNICATIONS MODULE 0 = None H = HART Communications Module. Availability pending, consult factory. DIGITAL I/O MODULE 0 = None D = Digital I/O Module with 1 Input, 2 Outputs. Availability pending, consult factory. PRESSURE RANGES 1S = Standard Range 1...Max. Span: 0 to 0.10 W.C. Turndown to 0.010 W.C. (10:1). 2S = Standard Range 2...Max. Span: 0 to 0.25 W.C. Turndown to 0.025 W.C. (10:1). 3S = Standard Range 3...Max. Span: 0 to 1.00 W.C. Turndown to 0.10 W.C. (10:1). 4S = Standard Range 4...Max. Span: 0 to 4.00 W.C. Turndown to 0.40 W.C. (10:1). 5S = Standard Range 5...Max. Span: 0 to 16.0 W.C. Turndown to 1.60 W.C. (10:1). 6S = Standard Range 6...Max. Span: 0 to 50.0 W.C. Turndown to 5.00 W.C. (10:1). CR = Compound Range...Consult factory. Supply desired Compound Range. All maximum pressure ranges have a turndown of 10:1. Specify Pressure Range # in model number (example 1S or CR). Standard Ranges: MST2000 will be calibrated at Maximum Span. If an Initial Range Setting is desired, supply with order and unit will be shipped with this Initial Range preset. (Example: 3S set to 0 to 0.5 W.C.). Compound Ranges: MST2000 will be calibrated at desired Compound Range. Supply compound range with order (example: -0.25 to +0.25 W.C.). All spans will be calibrated in Inches of W.C. Other Units of measure will be converted to Inches of W. C. OUTPUT 1 = 4-20mA Output. 2 = 4-20mA Output with Integral 120VAC to 24VDC Power Supply. 120VAC Source Required. MST2400 only. OPTIONS 0 = None B = Integral High Pressure Blowdown System. MST2400 Only. Requires Digital I/O Module. 120VAC source required. Enclosure size will change. Consult Factory for specifications and availability. P = Continuous Purge to Flowmeter. MST2400 Only. Spans of 0.25 W.C. or greater. A filtered air supply source of 20 to 80 PSI is required. ACCESSORIES 0 = None P = Pipe Mount. MST2400 Only. MST24 1 1 1 H D 2S 1 0 P NOTE: For factory setup of the MST2000 s multivariable configuration, provide the following information with your order. Initial Span Setting of MST2000 in Inches of Water Column if other than the standard range. External parameters for Temperature, Pressure and 2nd Differential Pressure Transmitter (Input Range, Zero/Span Values, etc.). Flowmeter Parameters and conditions. Type of Flowmeter. Effective Area in Square Feet or Kfactor of Flowmeter. Minimum/Maximum range of flow, temperature and pressure. Please include units of measure. Type of medium, molecular weight and specific gravity or density. Desired milliamp output setting. Inches of Water, SCFM, etc. Tagging Information.
MST2000 Loop Powered Multivariable SMARTFLOW Transmitter LCD Display Increment & Decrement Buttons Mode & Edit Buttons Reset Button Status Light & Reset Button for Isolated Input Options Test Jack 1/8 NPTF Process Connections Mounting Plate MST2000 Multivariable Versatility The MST2000 s multivariable capabilities provide the necessary versatility required to satisfy today s demanding industrial process applications. With programmable constants, input/output options and communication features the MST2000 will concurrently measure and/or apply the numerous process variables for a true mass flow measurement. The MST2000 s configuration is user friendly and is accomplished through the integral keypad (no external software or hardware is required). Optional input, digital I/O and communication modules can be installed at the factory or in the field as required. MST2100: NEMA 1 Enclosure MST2000 Loop Powered Multivariable SMARTFLOW Transmitter Differential Pressure Spans from 0.01 to 50.0 Inch. W.C. with 10:1 Turndown Temperature 4 Wire RTD Input Standard Programmable Constant or Optional 4-20 ma Analog Input Absolute Pressure Programmable Constant or Optional 4-20 ma Analog Input nd 2 D.P. Transmitter Optional 4-20 ma Analog Input HART User Interface Integral Keypad Programmable LCD Display 4-20 ma Output User Selectable Inches W.C., SCFM, ACFM or Lbs./Hr.
MST2000 Loop Powered Multivariable SMARTFLOW Transmitter FUNCTIONAL SPECIFICATIONS Service: Pressure Ranges: Clean, dry, non-corrosive Air or Gas. Other media may be possible with the use of the Continuous Purge option. Consult factory. Standard Pressure Ranges Range 1: 0 to 0.10 W.C. Range 2: 0 to 0.25 W.C. Range 3: 0 to 1.0 W.C. Range 4: 0 to 4.0 W.C. Range 5: 0 to 16.0 W.C. Range 6: 0 to 50.0 W.C. Standard Ranges have a turndown of 10:1. Compound ranges available. Consult factory. Example: Range 1 Maximum Range = 0 to 0.10 W.C., Minimum Range = 0 to 0.01 W.C. (Turndown of 10:1) Output Signals: Analog: 4-20 ma signal (Max. Loop resistance = 615 Ohms @ 24 VDC) is user programmable to Differential Pressure (Inches of Water Column) or Flow (SCFM, ACFM or LB/Hr). External inputs or programmed constants for temperature and absolute pressure are necessary for a true flow measurement. Digital: Two (2) optional digital (open collector) outputs available. Activation programmable by end user. Availability pending. Communications: Alarm Display: Power Supply Required: Reverse Polarity Protection: Turn On Time: Temperature Limits: Overpressure Limits: Damping: Humidity Limits: Inputs: Optional digital HART Communications module Availability pending. Programmable HI/LO Limit Alarm. High Contrast, 2 line, alphanumeric LCD with -20 o to 150 o F (-28 to 66 o C) operating temperature. 24 to 40 VDC loop power, minimum 10.5 volts required at inputs. Yes 4 seconds (maximum). Operating: -40 to 150 o F (-40 to 66 o C) Storage: -40 to 180 o F (-40 to 82 o C) Proof Pressure: 10 PSID Burst Pressure: 50 PSID Maximum Line Pressure: 50 PSIG Standard Time Constant: 500 msec. Additional damping adjustable via integral keypad from 0.5 to 5 Seconds in 0.5 second increments. 100% Non-condensing, (MST2400 Only). Standard: Non-isolated, 4 wire RTD input connection. Optional 4-20mA Isolated Inputs: Input ranges are software rangeable. External Temperature: 4-20mA Input. External Absolute Pressure: 4-20 ma Input External DP: 4-20mA Input Optional Digital Input: One optional digital (TTL level) input is available. Availability pending. PERFORMANCE SPECIFICATIONS Accuracy: Stability: Ambient Temperature: Mounting Position Effect: For spans from 40% to 100% of maximum range 1:1 to 2.5:1 then accuracy = 0.15% of Re-ranged Span. For spans from 20% to 39% of maximum range 2.5:1 to 5:1 then accuracy = (0.15 + 0.005 TD) of Re-ranged Span. For spans from 10% to 19% of maximum range 5:1 to 10:1 then accuracy = (0.15 + 0.010 TD) of Re-ranged Span. TD = Maximum Range / Re-ranged Span 0.1% of Maximum Range / 12 Months Zero: No Effect Span: Less than 0.001% of Re-ranged Span per Deg F. Corrected by internal temperature sensor. Minor effect on Zero. Corrected by setup parameters. Vibration Effect: Less than 0.2% of Maximum Range / g, 10-130 Hz. PHYSICAL SPECIFICATIONS: Enclosure Types: Process Connections: Electrical Connections: Weight: Company MST2100: NEMA 1, Anodized Aluminum. MST2400: NEMA 4X, Fiberglass. MST2100: 1 / 8 NPTF MST2400: 1 / 4 NPTF Stainless Steel MST2100 & MST2400: Cage Clamp style terminal block. 12-24 AWG wire size. MST2400: 1 / 2 Liquid-Tight flexible conduit connections. MST2100: 2.5 lbs. (1.14 kg) MST2400: 8.0 lbs (3.63 kg) For over 20 years, Thermo Electron has been the recognized leader in the measurement of air/gas flow and very low differential pressure in industrial applications. Thermo offers a complete line of pitot/static probes and arrays, D.P. Transmitters, the unique Nozzle Pitot Flow Sensor, turbine flowmeters, the 4400 Alarm Monitor and a complete family of Current to Pressure (I/P), Voltage to Pressure (E/P) and Pressure to Current (P/I) Transducers. Contact Thermo Electron, Therm's Representative, or visit our website for further information, specifications and applications assistance. www.thermo.com Let us point you in the right direction. Thermo Electron Corporation P.O. Box 1190, 3333 Airpark Road Fuquay, North Carolina 27526 U.S.A. Telephone: (919) 552-9011 Facsimile: (919) 552-9716 Represented By: NATIONAL ACCREDITATION OF CERTIFICATION BODIES SIRA CERTIFICATION SERVICE SUPPLIER QUALITY MANAGEMENT CERTIFICATE NO. 940099 ISO 9001 MD37-2000-00, March 2000 All specifications subject to change without notice. HART is a registered trademark of the HART Communications Foundation. All other trademarks acknowledged.