MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

Similar documents
PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

TPE 1464 Series Pressure Transducer

Explosion-Proof Gauge Pressure Transmitter

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Level-Lance Model 5400A

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Zone Pressure Touch Sensor - Standard Range

JT400 Multivariable Transmitter

MicroTrans EQ Signal Processor. Operation & Maintenance Manual

Zone Pressure Touch (ZPT) Sensor - Standard Range

Family of Water Cut Analyzers

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Conductivity Transmitters

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

CALIBRATORS. BetaGauge II INTRINSICALLY SAFE MODEL AVAILABLE

Installation and Operating Manual FM50 IOM 2-18 DRAFT

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Ultrasonic Flow Meter Brochure

Specifications - Installation and Operating Instructions. Duracell is a registered trademark of The Gillette Company.

Model 332 Differential Pressure Transmitter

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Multi-range pressure and differential pressure transmitter

Differential Liquid/Gas Pressure Transmitter

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

Model Sono-Trak General Specification

C100 Portable Multifunction

Flow Measurement SITRANS F US Clamp-on

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

DP DP2500 DP0250

TOXALERT MODEL AIR 2000

Trident and Trident X2 Digital Process and Temperature Panel Meter

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

SITRANS F flowmeters SITRANS F US

CDD4 Duct Carbon Dioxide Transmitter

CDD Carbon Dioxide Transmitter

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

DMT PERFORMING UNDER PRESSURE DMT. All-Media Pressure Scanner Features. Applications. Description 1/8

Control IT Booster Pump Controller

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

Series DMHF Heat Meter

MIST Version 2.0 USER S GUIDE. Preliminary Version. INTRODUCTION...2 General Description...2 Models Available...2

LS 6600 Technical Datasheet

Humidity goes Digital

DPC DPC PRECISION DIGITAL MASS FLOW CONTROLLER WITH MULTI-GAS FUNCTIONALITY

ZFM ZFM DIGITAL MASS FLOW METER

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Precision humidity/temperature control/sensing

200CRS Single-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics

MID approval no. DE-08-MI004-PTB004 Date of release

PDW30 Point-To-Point Wireless Bridge

Series TFXD FIXED LOCATION TRANSIT TIME FLOW METER FEATURES

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

NFC110. Flow Computer For Low Pulses FEATURES

PROJECT: SPECIFIER: TYPE: QTY: OUTPUT LEVEL: COLOR: LENGTH X WIDTH: MOUNTING: DIMMING/CONTROLS:

Series ULT Ultrasonic Level Transmitter

100mm Process Indicator Recorder

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

ETHERNET INTELLIGENT PRESSURE SCANNER

GFC114. Low Power Flow Computer FEATURES

Ultrasonic Heat Flow Meters

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Digital Indicator Solutions

Scanner 2000 Steam Mass Flow Transmitter

350 SMART MANOMETER OPERATING INSTRUCTIONS

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

General Specifications

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

Self-Powered Wireless Instrumentation

BA/BS4S Temperature Sensor Installation & Operating Instructions

VPINSTRUMENTS.COM VPFLOWSCOPE M. Your next step in gas flow measurement

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

How to build a Conductivity Measurement System

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

DPM DPM MULTI PARAMETER - MULTI GAS MASS FLOW METER

Rosemount 1595 Conditioning Orifice Plate

HIGH-VOLTAGE DC METER

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Safety. 1. Installation 1.1 CR:Services 1.2 Driver Card Installation 1.3 Sensor Types 1.4 Sensor Wiring

DREXELBROOK. Datasheet Universal IV In-Line Water Cut Meter. with Spool Piece Mounting USE THE BEST APPLICATIONS. Eliminate Routine Maintenance

Transcription:

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter Brandt Instruments MST2000 Series Loop Powered Multivariable SMARTFLOW Transmitter sets new standards for draft range Differential Pressure / Mass Flow measurement of Air and Gas Flows. Combining Brandt s twenty plus years of experience in industrial process control with state of the art digital signal processing technology, the MST2000 is the most versatile, reliable, cost-effective and simplest to operate loop powered multivariable transmitter in the industry. The MST2000 is a HART compatible, loop powered (two wire ) device available in either a compact, NEMA 1 configuration for wall or panel mounting or a rugged fiberglass NEMA 4X enclosure for hostile environments. With a turndown capability of 10:1 the available draft ranges can be turned as low as 0.01 Inches W.C. full scale. Fully programmable and user friendly, the MST2000 is capable of producing and displaying signals for Differential Pressure (Inches of Water Column) or for Flow (ACFM, SCFM, Lb/Hr). Optional isolated 4-20 ma inputs are available for Absolute Pressure, External Temperature and a second Differential Pressure Transmitter. A HART Communications Module and Digital I/O Module are also available. All the optional modules can be installed in the field by the end user. MST2000 Standard Features High Performance at Ultra Low Spans: Standard spans from 0.10 to 50 Inches Water Column are available (custom and compound ranges are also possible) with a total accuracy of 0.15% of Span. Thermal Compensated Output: Each MST2000 has an onboard temperature sensor and is thermally compensated at the factory to eliminate thermal effects. Password Protection: The MST2000 provides for password security so that modifications to program variables can only be made by authorized personnel. Adjustable Damping: The standard time constant is 500 msec but is user programmable from 0.5 to 5 seconds in 0.5 second intervals. LCD Display and Integral Keypad: A large, high contrast, easy to read LCD display and integral keypad allow the user to effortlessly program the MST2000 for optimal process conditions. Programmable Alarms: User selectable transmitter fault conditions can be programmed to set the 4-20 ma output to a low 3.9 ma or high 21.0 ma state. User can also select HI/LO process conditions to control the optional digital outputs. RTD Input: A non-isolated 4 wire RTD input connection is supplied for external temperature input. Integral Test Jack: Allows the user to monitor the ma output of the MST2000 without disconnecting the loop. Programmable Constants: When external temperature and absolute pressure signals are unavailable, these variables can be programmed in as constants, allowing the end user to select an output signal which will represent ACFM, SCFM or Lb/Hr. Without these constants, or external inputs, only the D.P. will be a true signal. MST2400: NEMA 4X Enclosure MST2000 Isolated Input Modules The MST2000 can be optionally configured with up to three (3) Isolated 4-20 ma input modules for true mass flow measurement. The input range for each input module is software rangeable by the end user. Any combination of the three can be mounted at the factory or field mounted by the user to upgrade process capabilities. Temperature Input Option: Accepts a 4-20 ma input from an external temperature transmitter. Absolute Pressure Input Option: Accepts a 4-20 ma input from an external absolute pressure transmitter. An optional integral absolute pressure transmitter can be mounted in the MST2400 enclosure. External Differential Pressure Input Option: Accepts a 4-20 ma input from an external differential pressure transmitter. A second differential input can be used to extend the available range to provide up to 2% flow rate accuracy over a 25:1 flow range. MST2000 Digital I/O Module The MST2000 can be optionally configured with (1) one digital input and (2) two digital outputs. This option is capable of either being installed at the factory or in the field. Digital Input: Accepts external signal to trigger events, such as a blowdown sequence. The MST2000 will hold the last output signal throughout the duration of the event. Digital Outputs: For control of external devices (AutoZero Valve, High Pressure Blowdown Systems, Alarm Circuits, etc.). HART Communications Module An optional HART Communication Module can be installed to provide industry standard HART access to the MST2000. This option can be installed at the factory or in the field.

Brandt Instruments, Inc., Fuquay, North Carolina 27526 USA (919) 552-9011 www.brandtinstruments.com MODE EDIT Run Alarm ABS. PRES. STATUS STATUS STATUS EXT. TEMP. Brandt Instruments, Inc. Fuquay, North Carolina USA LOOP+ LOOP- RTD+ SEN+ SEN- RTD- +EXTIN 1- +EXTIN 2- +EXTIN 3- +DI1- + DO1- +DO2- RX/TX+ GNDRX/TX- TM Auto Zero Blowdown EXT. DP Brandt Instruments, Inc., Fuquay, North Carolina 27526 USA (919) 552-9011 www.brandtinstruments.com Model: MST2111002S1P 4-20mA Loop Powered Serial Number: 2002001 Range: 0 to 0.25 Inches W.C Abs.Prs Temp. ExtDP LOOP RTD SEN SEN RTD EXTIN 1 EXTIN 2 EXTIN 3 DI 1 DO 1 DO 2 RX/TX INC. DEC. Brandt Instruments, Fuquay, North Carolina 27526, USA (919) 552-9011 Dimensions 2.33 Inches 59.2 mm 6.25 Inches 158.8 mm 6.75 Inches 171.5 mm TM MST2000 Multivariable SMARTFLOW Transmitter MODE INC. 7.0 Inches 177.8 mm EDIT Run Alarm 0.250 - INWC DEC. Auto Zero Blowdown 6.5 Inches 165.1 mm _TEST + ABS. PRES. STATUS STATUS STATUS Model: MST2111002S1P Serial Number: 2002001 EXT. TEMP. Brandt Instruments, Inc. Fuquay, North Carolina USA 4-20mA Loop Powered Range: 0 to 0.25 Inches W.C EXT. DP + + + Abs.Prs + + Temp. + ExtDP + _ + _ + _ + _ LOOP RTD SEN SEN RTD EXTIN 1 EXTIN 2 EXTIN 3 DI 1 DO 1 DO 2 RX/TX LCD Display & Integral Keypad HI LOW 1/8"NPTF Process Connections Bottom View LOOP+ LOOP- RTD+ SEN+ SEN- RTD- +EXTIN 1- +EXTIN 2- +EXTIN 3- +DI1- + DO1- +DO2- RX/TX+ GNDRX/TX- HI LOW Status Light & Resets for Isolated Input Options Side View Test Jacks Top View 0.25 Inch (6.35mm) Dia. Mounting Holes (4X) MST2100: NEMA 1 Enlcosure Top View 0.25 Inch Dia. Mounting Holes (4X) 7.688 Inches 195.3 mm 6.125 Inches 155.6 mm MST2000 Multivariable SMARTFLOW Transmitter 0.250 - INWC 9.188 Inches 233.4mm 9.688 Inches 246.1 mm _TEST + + + + + + + + + + + 11.188 Inches 284.2 mm Brandt MST24111002S1P Serial No:20002001 0 to 0.25 INWC 4-20 ma Loop Powered Output Signal HI LOW 1/2" Conduit Connection Bottom View Window 1/4"NPTF Process Connections Located on MST2000 Front View Recessed Captive Screws Optional 2.5" Pipe Mount Side View With Optional 2.5" Pipe Mount MST2400: NEMA 4X Fiberglass Enclosure

SERIES: LOOP POWERED MULTIVARIABLE SMARTFLOW TM TRANSMITTER MST2000 Model Number Description MST21 = MST2100, NEMA 1 Panel Mount Enclosure, Differential Pressure Configuration & Non-isolated 4 Wire RTD Input Standard. MST24 = MST2400, NEMA 4X, Fiberglass Enclosure, Differential Pressure Configuration & Non-isolated 4 Wire RTD Input Standard. ISOLATED INPUT MODULE: Absolute Pressure Transmitter 0 = None 1 = Isolated Input Module: Accepts 4-20mA input signal from an External Absolute Pressure Transmitter. 2 = Isolated Input Module with Integral Absolute Pressure Transmitter, 0-25 PSI range standard. Consult factory for other ranges. MST2400 only. Requires external 24V source. ISOLATED INPUT MODULE: Temperature Transmitter 0 = None 1 = Isolated Input Module: Accepts 4-20mA input signal from an External Temperature Transmitter. ISOLATED INPUT MODULE: 2 nd Differential Pressure Transmitter 0 = None 1 = Isolated Input Module: Accepts 4-20mA input signal from a 2 nd External D.P. Transmitter. COMMUNICATIONS MODULE 0 = None H = HART Communications Module. Availability pending, consult factory. DIGITAL I/O MODULE 0 = None D = Digital I/O Module with 1 Input, 2 Outputs. Availability pending, consult factory. PRESSURE RANGES 1S = Standard Range 1...Max. Span: 0 to 0.10 W.C. Turndown to 0.010 W.C. (10:1). 2S = Standard Range 2...Max. Span: 0 to 0.25 W.C. Turndown to 0.025 W.C. (10:1). 3S = Standard Range 3...Max. Span: 0 to 1.00 W.C. Turndown to 0.10 W.C. (10:1). 4S = Standard Range 4...Max. Span: 0 to 4.00 W.C. Turndown to 0.40 W.C. (10:1). 5S = Standard Range 5...Max. Span: 0 to 16.0 W.C. Turndown to 1.60 W.C. (10:1). 6S = Standard Range 6...Max. Span: 0 to 50.0 W.C. Turndown to 5.00 W.C. (10:1). CR = Compound Range...Consult factory. Supply desired Compound Range. All maximum pressure ranges have a turndown of 10:1. Specify Pressure Range # in model number (example 1S or CR). Standard Ranges: MST2000 will be calibrated at Maximum Span. If an Initial Range Setting is desired, supply with order and unit will be shipped with this Initial Range preset. (Example: 3S set to 0 to 0.5 W.C.). Compound Ranges: MST2000 will be calibrated at desired Compound Range. Supply compound range with order (example: -0.25 to +0.25 W.C.). All spans will be calibrated in Inches of W.C. Other Units of measure will be converted to Inches of W. C. OUTPUT 1 = 4-20mA Output. 2 = 4-20mA Output with Integral 120VAC to 24VDC Power Supply. 120VAC Source Required. MST2400 only. OPTIONS 0 = None B = Integral High Pressure Blowdown System. MST2400 Only. Requires Digital I/O Module. 120VAC source required. Enclosure size will change. Consult Factory for specifications and availability. P = Continuous Purge to Flowmeter. MST2400 Only. Spans of 0.25 W.C. or greater. A filtered air supply source of 20 to 80 PSI is required. ACCESSORIES 0 = None P = Pipe Mount. MST2400 Only. MST24 1 1 1 H D 2S 1 0 P NOTE: For factory setup of the MST2000 s multivariable configuration, provide the following information with your order. Initial Span Setting of MST2000 in Inches of Water Column if other than the standard range. External parameters for Temperature, Pressure and 2nd Differential Pressure Transmitter (Input Range, Zero/Span Values, etc.). Flowmeter Parameters and conditions. Type of Flowmeter. Effective Area in Square Feet or Kfactor of Flowmeter. Minimum/Maximum range of flow, temperature and pressure. Please include units of measure. Type of medium, molecular weight and specific gravity or density. Desired milliamp output setting. Inches of Water, SCFM, etc. Tagging Information.

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter LCD Display Increment & Decrement Buttons Mode & Edit Buttons Reset Button Status Light & Reset Button for Isolated Input Options Test Jack 1/8 NPTF Process Connections Mounting Plate MST2000 Multivariable Versatility The MST2000 s multivariable capabilities provide the necessary versatility required to satisfy today s demanding industrial process applications. With programmable constants, input/output options and communication features the MST2000 will concurrently measure and/or apply the numerous process variables for a true mass flow measurement. The MST2000 s configuration is user friendly and is accomplished through the integral keypad (no external software or hardware is required). Optional input, digital I/O and communication modules can be installed at the factory or in the field as required. MST2100: NEMA 1 Enclosure MST2000 Loop Powered Multivariable SMARTFLOW Transmitter Differential Pressure Spans from 0.01 to 50.0 Inch. W.C. with 10:1 Turndown Temperature 4 Wire RTD Input Standard Programmable Constant or Optional 4-20 ma Analog Input Absolute Pressure Programmable Constant or Optional 4-20 ma Analog Input nd 2 D.P. Transmitter Optional 4-20 ma Analog Input HART User Interface Integral Keypad Programmable LCD Display 4-20 ma Output User Selectable Inches W.C., SCFM, ACFM or Lbs./Hr.

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter FUNCTIONAL SPECIFICATIONS Service: Pressure Ranges: Clean, dry, non-corrosive Air or Gas. Other media may be possible with the use of the Continuous Purge option. Consult factory. Standard Pressure Ranges Range 1: 0 to 0.10 W.C. Range 2: 0 to 0.25 W.C. Range 3: 0 to 1.0 W.C. Range 4: 0 to 4.0 W.C. Range 5: 0 to 16.0 W.C. Range 6: 0 to 50.0 W.C. Standard Ranges have a turndown of 10:1. Compound ranges available. Consult factory. Example: Range 1 Maximum Range = 0 to 0.10 W.C., Minimum Range = 0 to 0.01 W.C. (Turndown of 10:1) Output Signals: Analog: 4-20 ma signal (Max. Loop resistance = 615 Ohms @ 24 VDC) is user programmable to Differential Pressure (Inches of Water Column) or Flow (SCFM, ACFM or LB/Hr). External inputs or programmed constants for temperature and absolute pressure are necessary for a true flow measurement. Digital: Two (2) optional digital (open collector) outputs available. Activation programmable by end user. Availability pending. Communications: Alarm Display: Power Supply Required: Reverse Polarity Protection: Turn On Time: Temperature Limits: Overpressure Limits: Damping: Humidity Limits: Inputs: Optional digital HART Communications module Availability pending. Programmable HI/LO Limit Alarm. High Contrast, 2 line, alphanumeric LCD with -20 o to 150 o F (-28 to 66 o C) operating temperature. 24 to 40 VDC loop power, minimum 10.5 volts required at inputs. Yes 4 seconds (maximum). Operating: -40 to 150 o F (-40 to 66 o C) Storage: -40 to 180 o F (-40 to 82 o C) Proof Pressure: 10 PSID Burst Pressure: 50 PSID Maximum Line Pressure: 50 PSIG Standard Time Constant: 500 msec. Additional damping adjustable via integral keypad from 0.5 to 5 Seconds in 0.5 second increments. 100% Non-condensing, (MST2400 Only). Standard: Non-isolated, 4 wire RTD input connection. Optional 4-20mA Isolated Inputs: Input ranges are software rangeable. External Temperature: 4-20mA Input. External Absolute Pressure: 4-20 ma Input External DP: 4-20mA Input Optional Digital Input: One optional digital (TTL level) input is available. Availability pending. PERFORMANCE SPECIFICATIONS Accuracy: Stability: Ambient Temperature: Mounting Position Effect: For spans from 40% to 100% of maximum range 1:1 to 2.5:1 then accuracy = 0.15% of Re-ranged Span. For spans from 20% to 39% of maximum range 2.5:1 to 5:1 then accuracy = (0.15 + 0.005 TD) of Re-ranged Span. For spans from 10% to 19% of maximum range 5:1 to 10:1 then accuracy = (0.15 + 0.010 TD) of Re-ranged Span. TD = Maximum Range / Re-ranged Span 0.1% of Maximum Range / 12 Months Zero: No Effect Span: Less than 0.001% of Re-ranged Span per Deg F. Corrected by internal temperature sensor. Minor effect on Zero. Corrected by setup parameters. Vibration Effect: Less than 0.2% of Maximum Range / g, 10-130 Hz. PHYSICAL SPECIFICATIONS: Enclosure Types: Process Connections: Electrical Connections: Weight: Company MST2100: NEMA 1, Anodized Aluminum. MST2400: NEMA 4X, Fiberglass. MST2100: 1 / 8 NPTF MST2400: 1 / 4 NPTF Stainless Steel MST2100 & MST2400: Cage Clamp style terminal block. 12-24 AWG wire size. MST2400: 1 / 2 Liquid-Tight flexible conduit connections. MST2100: 2.5 lbs. (1.14 kg) MST2400: 8.0 lbs (3.63 kg) For over 20 years, Thermo Electron has been the recognized leader in the measurement of air/gas flow and very low differential pressure in industrial applications. Thermo offers a complete line of pitot/static probes and arrays, D.P. Transmitters, the unique Nozzle Pitot Flow Sensor, turbine flowmeters, the 4400 Alarm Monitor and a complete family of Current to Pressure (I/P), Voltage to Pressure (E/P) and Pressure to Current (P/I) Transducers. Contact Thermo Electron, Therm's Representative, or visit our website for further information, specifications and applications assistance. www.thermo.com Let us point you in the right direction. Thermo Electron Corporation P.O. Box 1190, 3333 Airpark Road Fuquay, North Carolina 27526 U.S.A. Telephone: (919) 552-9011 Facsimile: (919) 552-9716 Represented By: NATIONAL ACCREDITATION OF CERTIFICATION BODIES SIRA CERTIFICATION SERVICE SUPPLIER QUALITY MANAGEMENT CERTIFICATE NO. 940099 ISO 9001 MD37-2000-00, March 2000 All specifications subject to change without notice. HART is a registered trademark of the HART Communications Foundation. All other trademarks acknowledged.