EMP1 OPERATING & INSTALLATION INSTRUCTIONS

Similar documents
KOBOLD PDA Series Digital Pressure Transmitter

Series ULT Ultrasonic Level Transmitter

SECTION THERMAL UTILITY METERING INTERFACE

Flow Measurement Applications

DCT7088 Portable Digital Correlation Transit Time Flowmeter

BLDA-1 & 2 Water Leak Detection Manual. CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel:

SERVICE AND INSTALLATION INSTRUCTIONS

KOBOLD TDA Series Digital Temperature Transmitter

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Installation and Operating Manual FM50 IOM 2-18 DRAFT

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Rosemount 1595 Conditioning Orifice Plate

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98

Type Approval Certificate

Installation Guide Solid State Meter

Operating Instructions for Turbine Wheel Flow Meter Model: TUR

Badger Meter Europa GmbH. INSTRUCTION MANUAL Deluxe LCD display for the MN series. September Version MN-Deluxe LCD display-09/01-e

Standard Circulating Pumps

Model 8702 DP-CALC Micromanometer

MONARCH INSTRUMENT. TACH-4A / TACH-4AR Programmable Optical Tachometer. Instruction Manual Rev 2.0

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

RATIO CONTROLLER HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION NOTE DESCRIPTION SPECIFICATION

SOLUTIONS ONICON. Innovative HVAC Flow and Energy Measurement Solutions PRECISE, RELIABLE, TRUSTED

Rosemount 1595 Conditioning Orifice Plate

Family of Water Cut Analyzers

Ultrasonic Flow Meter Brochure

Digi-Stem Digital Temperature Indicating Devices for Food Processing

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Signet Conductivity Electrodes

Phone: Fax: For calls outside the US please call:

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

SERVICE AND INSTALLATION INSTRUCTIONS

Sidewinder Pumps Inc. AC Timer/Controller

HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0215

USER GUIDE. Differential Thermometer Datalogger. Model HD200

VAREC 5000/5010 SERIES FLAME ARRESTERS

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Installation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C*

353 PRECISION ALTIMETER TESTER OPERATING INSTRUCTIONS

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-1-USA

MTP INSTRUCTION MANUAL

MODEL 245 / 345 High Range

Series 3000 User Manual and Product Features

SD1. Differential Controller. Operating and Installation Instructions F2 72.3

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

American Society of Sanitary Engineering Seal (Certification) Program

Rosemount 1595 Conditioning Orifice Plate

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS

Mount Pleasant Waterworks. Cross-Connection Control Program Guidelines October 2010

Chemlock PFA and PP Filter Housings

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

2 CLASS AMR READY INVONIC H DATA APPLICATION HEAT METERING. approved ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50

HI HI N HI HI

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

Spectrum 500D 3/4 gpm Functional Specifications Physical Specifications Standards Spectrum 500D (3 or 4 )

TR-3000 STORM WATER SAMPLER MANUAL OF OPERATION.

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart.

Portable Dual Frequency Doppler Flowmeter

VACUUM METER Model : VC-9200

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

Ultra Sonic Flowmeter DATASHEET

Quantichem 9065C Portable Luminescent Dissolved Oxygen Analyzer Quick Reference Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Rosemount 1595 Conditioning Orifice Plate

VELOCICALC Air Velocity Meter

Spectrum 175D. meter performance with no maintenance.

Energy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free

wd-2

EQUIPMENT Operation Manual

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

P027 Series Pressure Transducer Installation & Operation Manual

DC100 Digital Dispenser Operating Manual

GF90 Installation, Operation and Troubleshooting Guide

The 5400A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel.

Rosemount 1595 Conditioning Orifice Plate

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from

EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS

Cole-Parmer Instrument Company

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

KUHLMAN INSTRUMENT COMPANY 5000K WARRANTY

Nuclear Associates

RWD32S Software Tool. Operating Instructions. CE1U3344en Building Technologies

MEMS Mass Flow Meter. User Manual (V A.4) MF5700 Series SIARGO LTD.

Isotemp. Bath Circulators. Improve the productivity. of your lab with solutions. from Fisher Scientific

Standard Circulating Pumps

Explosion-Proof Gauge Pressure Transmitter

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

CONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA

ThermoPro TM Series TP10

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016

SONOMETER TM 500 Ultrasonic compact energy meter

Operating Instruction PPC-04 /2

PRO REMOTE 25 CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT Jamieson Equipmen toll free 800

EW170 Series Woltman Bulk Water Meters DN FOR COLD AND WARM POTABLE WATER APPLICATIONS

350 SMART MANOMETER OPERATING INSTRUCTIONS

Transcription:

468 Liberty Drive Wittenberg, WI 54499 U.S.A. Tel: 715-253-2801 Ver.11-01-2008 Fax: 715-253-2811 Web: www.solar.imcinstruments.com REV. 5-15-10 EMP1 OPERATING & INSTALLATION INSTRUCTIONS EMP1-0200 PILOT 12-20-09 WATER FLPM-0200 INSTRUMENTATION WITH QUALITY ENGINEERING

EMP1 OPERATING & INSTALLATION INSTRUCTIONS TABLE OF CONTENTS PG 2 PG3 PG4 PG6 PG8 Pg10 Pg12 Pg13 TABLE OF CONTENTS PRODUCT DESCRIPTION PERFORMANCE SPECIFICATIONS AND OIML R-075 CERTIFICATE OF CONFORMANCE SIZE 2 - MODEL FLPM-0200 FLOW METER SIZE 1 - MODEL FLPM-0100 FLOW METER SIZE 1 ½ - MODEL FLPM-0150 FLOW METER SIZE 3/4 - MODEL FLPM-0075 FLOW METER ENERGY METER SETUP INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTION FOR FLOW METERS MODELS FLPM & FLPH INSTRUMENTATION WITH QUALITY ENGINEERING PG2

IMC EAGLE 2 DIFFERENTIAL CONTROLLERS / ENERGY METER The IMC EAGLE 2 DIFFERENTIAL CONTROLLERS with built in BTU METERS are being sold only to qualified Distributors as PROJECTS "one at a time". These "projects" as we call them today, are fully functional products minus a few future features such as a 5th sensor for top of tank temperature monitoring and so on. They include a full featured EAGLE 2 WEB Differential Controller with an isolated serial interface which can be permanently connected to a PC for data logging and a FLOW meter plug and play interface. The following are the sizes of flow meters that are available : 3/4", 1", 1-1/2" and 2". Please see pgs 4-9. The controller has 4th and a 5th pages on the display that includes GPM and Kilo-watt hours of collected energy. It is FLASHED into permanent memory every 20 minutes incase of power failures. The customer has to read the KILOWATT HOUR METER value and record it every month or at any other interval he wishes. He can also reset the Kilo watt hour counter to ZERO if he follows the RESET instructions. The BTU calculations have bee carefully programmed to take into account the effects of Glycol-water mixtures. The Processors are permanently programmed to a specific percentage of Propylene Glycol present in the heat transfer solution from 0 % to 100%. We supply Precision MATCHED sensors to with in 0.2F which are essential for accurate BTU calculations. The matching was been tested and verified over the range of 80F to 210F in our precision temperature baths for each set of sensors supplied with each BTU / CONTROLLER. Connecting cables to both sensors have to also be matched with in 1.5 ohms of each other in the field. Cable length equivalency = 18Ga.>75, 20Ga.>35. 22Ga.>20 feet For your information most of these initial systems are being connected to WIRED SOLAR for WEB monitoring and PUBLISHING. A very impressive marketing TOOL. There is now a stand alone PC based software package SOLAR-BTU-LOG that can be installed in a local PC to monitor and DATA log in graphical form the entire solar installation. This information is available for download directly from our website at www.solar.imcinstruments.com. Rev 05-15-2010 EMP1-0200 PILOT 12-20-09 WATER FLPM-0200 Line Corded models also available SOLAR BTU CHARTING / LOGGING SOFTWARE PG3

468 Liberty Dr. Wittenberg, WI,54499, USA TEL 715-253 2801 715-445 4946 FAX 715-253 2811 THERMAL ENERGY METER MODEL # EAGLE 2 PILOT BTU 1-4-2010 PERFORMANCE SPECIFICATIONS The ENERGY METER shall consist of the following : 1) Flow meter having an error no greater than 2.0 % over the measuring range from its minimun transitional flow Qtr to its maximum normal operating flow Qn. See below ERROR % Qmin Qtr Qn Qmax 4 2 0-2 -4 FLOW GPM The flow meter must have test certificates showing conformance to the above required accuracies by approved test methods or labs. In order to minimize other possible sources of error, installation guide lines for proper fluid entry and exit to the flow meters must be strictly adhered to. For Physical and Electrical specifications please refer to attached Flow meter specifications and or Literature. 2) Two Precision Matched IMMERSION Temperature sensors with a temperature difference error no greater than 0.2 degrees F from a measured temperature of 77 F (25C) to 220 F (104.4C). Insure that the temperature sensors are properly exposed to the heat transfer fluid media and insulated from the effects of external temperatures. The Temperature sensors must have a test certificate that is NIST traceable showing conformance to the stated accuracies of this specification. 3) Differential Solar Temperature Controller with four-matched temperature channels and a built in ENERGY METER TOTALIZER using the precision sensors and the flow meter to provide a sum total of the accumulated thermal energy to be displayed in a continuous RUNNING TOTAL of Electrical equivalent of thermal energy expressed in KILOWATT HOURS. The sum total can be manually reset to Zero only. No other alterations to the VALUE are possible. For Physical and Electrical specifications please refer to attached Flow meter specifications and or Literature.. 4) Energy Computer to calculate and Totalize the Thermal Energy elements with a maximum of a 17 second interval frequency. The calculations must follow well-established calorimetry mythology as set forth by the ASHRAE HAND BOOK of FUNDAMENTALS. Physical constants for the heat transfer fluid must be accurately defined for the Density and Specific Heat of the heat transfer fluid every 10 degrees F from a temperature of 77 F (25C) to 220 F (104.4C) and must be included in the energy content calculations. If Glycol is part of the Heat Transfer fluid, the Density and Specific Heat constants obtained form a recognized Laboratory must also be included in accordance with the water to Glycol mixture and temperatures that the fluid is at when the energy measurements are made. a) The Kilowatt-Hours readings will be stored in the energy computer's PERMANENT memory and retained for a period of at least 12 years. NO BATTERIES ARE REQUIRED. The maximum number of Kilowatt-Hours is 830,000 at which time the contiguous counter will reset to ZERO and start over again. INSTRUMENTATION WITH QUALITY ENGINEERING PG4

PERFORMANCE SPECIFICATIONS cont b) The over all accuracy of the Thermal Energy meter is dependant on the magnitude of the heat transfer fluid temperature increase thru the solar collection as follows: Temp Diff Flow Mtr Error Sensor error Calculator error MAXIMUM TOTAL error 50.0 F ** +/- 2.0% Max +/-0.2F/50.0 = 0.4% +/- 0.4% 2.8%** 14.0 F +/- 2.0% Max +/-0.2F/14.0 = 1.4% +/- 0.4% 3.8% 11.2 F +/- 2.0% Max +/-0.2F/11.2 = 1.8% +/- 0.4% 4.2% 7.5 F +/- 2.0% Max +/-0.2/F7.5 = 2.6% +/- 0.4% 5.0% 5.4 F** 3.5 F +/- 2.0% Max +/- 2.0% Max +/-0.2/F5.4 = 3.7% +/-0.2F/3.5 = 5.7% +/- 0.4% +/- 0.4% 6.1%** 8.1% -- Currently The following PROPYLENE GLYCOLS are approved and stored in our computers for use with IMC ENERGY METERS Dow Frost-HD -The Dow Chemical No Burst-HD - The Noble Company As other Glycols are approved they will be characterized and entered into the IMC Energy METERS. Please contact the factory for additional information **Note values used to show OIML compliance 468 Liberty Dr. Wittenberg, WI,54499, USA TEL 715-253 2801 715-445 4946 FAX 715-253 2811 CERTIFICATE OF COMPLIANCE for IMC Energy Meters EMP1-0050 EMP1-0075 EMP1-0100 EMP1-0150 EMP1-0200 With OIML R 75-1 Specification Date: 15 May 2010 Certifying engineer. Louis Frias Engineering Manager- IMC Instruments 468 Liberty Drive, Wittenberg, WI 54499 Tel: 715-253-2801 INSTRUMENTATION WITH QUALITY ENGINEERING PG5

MODEL FLPM-0200 FLOW METER 2 FLOW METER PG6 8-07- 2009

MODEL FLPM-0200 FLOW METER FLANGE TYPE ANSI 150 H2 H1 L www.solar.imcinstruments.com PRODUCT # FLPM-0200 SIZE: 2 INCH FLANGED; MOUNT HORIZONTAL / VERTICAL 1.5 min to 66 max GPM CONT. O 200 F MAX; 225 PSI MAX S/N ; CSN K=2 038 220 L 7 7/8 B 6 1/8 H1 2 7/8 H2 3 5/8 WEIGHT 22 LBS B PRESSURE LOSS Ploss=0.0000748 x Q Ploss=PSIG, Q=GPM PG7 02-05-2010 2

MODEL FLPM-0100 FLOW METER MODEL FLPM-0150 FLOW METER 1 and 1 1/2 FLOW METERS 02-05- 2010 PG8

B H H1 H1 L C MODEL FLPM-0100 FLOW METER MODEL FLPM-0150 FLOW METER L 10 1/4 B 3 5/8 H1 1 7/8 H 3 3/8 C 2 5/8 WEIGHT 6 LBS PRODUCT # FLPM-0100 www.solar.imcinstruments.com SIZE: 1 INCH NPT; MOUNT HORIZONTAL with THIS SIDE UP 0.5 min to 14 max GPM CONT. O 200 F MAX; 150 PSI MAX S/N # ; CSN # K=0913 L 11 3/4 B 4 3/4 H1 1 7/8 H 3 3/8 C 2 7/8 WEIGHT 12 LBS PRODUCT # FLPM-0150 www.solar.imcinstruments.com SIZE: 1-1/2 INCH NPT; MOUNT HORIZONTAL with THIS SIDE UP 0.8 min to 24 max GPM CONT. O 200 F MAX; 150 PSI MAX S/N #; CSN # K=1302 PRESSURE LOSS Ploss=0.00456 x Q Ploss=PSIG, Q=GPM 2 PRESSURE LOSS Ploss=0.001546 x Q Ploss=PSIG, Q=GPM 2 02-05-2010 PG9

MODEL FLPM-0075 FLOW METER 3/4 FLOW METER PG10 8-07- 2009

MODEL FLPM-0075 FLOW METER A B C C1 www.solar.imcinstruments.com PRODUCT # FLPM-0075 SIZE: 3/4 INCH NPT; MOUNT HORIZONTAL / VERTICAL 0.2 min to 7 max GPM CONT. O 200 F MAX; 150 PSI MAX S/N #; CSN # K=202 A 1/4 B 1 5/8 C1 2 1/8 C 5 1/8 WEIGHT 1.5 LBS PRESSURE LOSS Ploss=0.0287 x Q Ploss=PSIG, Q=GPM 2 02-05-2010 PG11

468 Liberty Dr. Wittenberg, WI,54499, USA TEL 715-253 2801 715-445 4946 FAX 715-253 2811 SET UP INSTRUCTIONS Dated 02-15-2010 IMC EAGLE 2 DIFFERENTIAL CONTROLLER / ENERGY METERS For the proper installation of the Thermal Energy meter please insure that the following Installation Documents have been reviewed and carefully followed: 1) Flow meter INSTALLATION instructions 2) Eagle 2 WEB CONTROLLER General description and INSTALLATION instructions The Energy Meter feature of the combination Solar Differential Controller/Energy Meter requires two system components to be carefully set up and verified for proper operation as follows: 1) The TWO DIFFERENTIAL TEMPERATURE SENSORS which have been matched to each other to an accuracy of 0.2 degrees F. They have to be keep togther as they have calibration numbers in their lead wires that identify their nominal matching numbers. Sensors from other production batches can not be used for this purpose unless they have identical calibration numbers. Sensor matching was tested and verified over the range of 80F to 210F in our precision temperature baths for each set of sensors supplied with each BTU / CONTROLLER. Connecting cables to both sensors have to be matched with in 1.5 ohms of each other in the field. Maximum allowable cable length are 18Ga.=75 max, 20Ga.=35 max and 22Ga.=20 feet max. When connecting the sensors to the energy Meter, the HI-sensor must be connected to AUX1 terminals and the LO-sensor to the AUX2 terminals. Insure that the sensors are measuring only the fluid flow temperatures and are un affected by local surrounding temperatures. 2) The Plug and Play Flow Meter must be properly installed and protected of debris in the fluid with the use of filter strainers. The flow meter is furnished with a matching PROCESSOR and requires no additional set up. Just make sure that the male/female connectors are FIRMLY brought together until an engaging klick is felt. Proper operation can be verified when there is fluid flow by observing ON and OFF flashing of the in-line BLUE LED located in the connecting cable. After a maximum of 17 seconds the flow GPM will be displayed in the Energy meter LCD window. Make sure that the display is paged to the proper GPM window. For the final operation of the Energy meter the LCD display can be paged to the Kilo-Watt Hour page to view the TOTALIZED energy in KWH with a resolution of 1/10ths of a KWHR. This reading can be reset to ZERO by pressing and holding down the paging button for 33 seconds until the KWH reading shows 0000000.0. INSTRUMENTATION WITH QUALITY ENGINEERING PG12

IMC FLOW METERS MODELS FLPM & FLPH INSTALLATION AND OPERATING INSTRUCTION Rev. 1-11-2010 1) Prior to installation please confirm that the system TEMPERATURE and PRESSURE DO NOT EXCEED the NAME PLATE RATING. The maximum flow specified for the meter should also never be exceed as excessive wear may occur. 2) It is recommended that UNIONS and SHUT OFF VALVES be installed upstream and downstream of the flow meter to allow for service and removal of the flow meter. IF the meter is to be temporarily removed a piece of straight pipe can be installed in its place until the meter is serviced and returned back into operation. 3) To insure that only clean liquid enters the flow meter it is HIGHLY recommended that a STRAINER be installed upstream of the meter inlet. In addition to the above it is also recommended that the system be flushed thoroughly after any plumbing changes. The use of Pipe tape is discouraged in lieu of TFE plumbers compound thread paste to avoid loose tape from entering the fluid stream. 4) When installing the flow meter pay careful attention that the direction of flow matches the arrow on the body of the flow meter. The flow meter body is to be mounted with the name plate facing UP. The only exception to this is when vertical mount is permitted and is clearly shown on the name plate of the flow meter. 5) For the 1/2" and 3/4" flow meters there is a requirement to have at least 5 pipe diameters of STRAIGHT pipe in order to achieve rated accuracy. For Meters 1" and larger a 3 pipe diameter will meet this requirement. 6) EXTRA SPECIAL ATTENTION should be paid in PREVENTING the flow meter from being exposed to WATER HAMMER as well as FREEZING fluids. Damage will occur Any questions should be directed to: Attn. Flow meter dept. IMC Instruments, Inc. 468 Liberty Drive Wittenberg, WI 54499 (715) 445-4946 PG13