CI-tronic Reversing contactor Type RCI

Similar documents
CI-tronic Soft start motor controller

Contact protection relay

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Solid-State Contactors

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

MCX08M2 Programmable controller

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-ERD.12

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Disconnect Switches. Safe Switching and Disconnecting

Data sheet. CI-TI TM Contactors and Motor Starters Timers ATI, BTI, MTI 520B1307

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Micro Contactor MA Series

Electronic timer CT-AHD.22

Switching relay CT-IRE with 1 c/o (SPDT) contact

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Electronic time relays ATI, BTI, SDT and MTI

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Power Electronics. Semiconductor relay / - contactor

Mini Contactors & Overloads

Modulating controlled actuator AME 11

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Installation / Control Technique

Circuit Breakers Type CTI 25M, CTI 45MB

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Electronic timer CT-ARS.11

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Three-phase monitoring relay

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Electronic timer CT-ERS.21

ELR W1/ 6-24DC. Extract from the online catalog. Order No.:

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Voltage Current Front-mounting bracket

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

Motor protection circuit breakers

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

CC COMPACT DIP SWITCH

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

COMPACT LED CONVERTERS 48 V

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Actuators for modulating & 3-point control

Zelio Control-modular measurement and control relays 1

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Bulletin 817 Thermistor Protection Relay

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Thermistor motor protection relay CM-MSS.21

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

DRMS SERIES DIN RAIL MOUNT HYBRID MOTOR STARTERS

RW-E. Overloads. Solid-State Overload Relays. Standard Features

MOTOR PROTECTION CIRCUIT BREAKERS

Power Supply HARTING pcon

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Thermistor motor protection relay CM-MSS.41

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Transcription:

Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast and precise motor control and virtually eliminates EMC emission. The RCI reversing contactor is ideal where fast switching capability and long life are essential. Typical applications are conveyors, thread cutting machines, packaging lines and other applications where fast reversing capabilities are needed. Features Compact modular design complete with heat sink DIN-rail mountable Built-in varistor protection Operational current up to 10 A (AC-3) Line voltage up to 480 V AC Built-in interlock Universal control voltage Burst firing (zero cross) LED status indicator IP 20 protection Problem-free specification according to industry standard Easy and quick installation EN 60947-4-2 and UL-C Danfoss DCS (mw) 2017.10 IC.PD.C50.D3.02 520B3036 1

Selection guide Operational voltage Max. motor current Max. motor power 24 480 V AC 10 A 4 kw / 5.5 HP Control Dimensions Type Code no. voltages 5 24 V DC 45 mm 037N0044 RCI 10 24 230 V AC / DC module 037N0043 Technical data Output specifications Operational current AC-3 (motor load) AC 4 (motor load) Motor size at 208 240 V AC (50 / 60 Hz) 400 480 V AC (50 / 60 Hz) Leakage current max. Operational current min. Semiconductor protection fusing Type 1 coordination Type 2 coordination 10 A 8 A AC-3: 0.1 2.2 kw (0.18 3 HP) AC-4: 0.1 1.5 kw (0.18 2 HP) AC-3: 0.1 4 kw (0.18 5.5 HP) AC-4: 0.1 3 kw (0.18 4 HP) 1 ma 10 ma 50 A gl / gg 450 A 2 s Technical data (continued) Thermal specification and environment Power dissipation Continuous duty Intermittend duty 2.0 W/A 2.0 W/A x duty cycle Ambient temperature range 5 C to 60 C Cooling method Neutral convection Mounting Vertical (± 30 ) Storage temperature range 20 C to 80 C Enclosure degree / pollution degree IP 20/3 Insulation Rated insulation voltage, U i Rated impulse withstand voltage, U imp Installation category 660 V AC 4 kv III Control circuit specifications 037N0044 037N0043 Control voltage range (±10%) 5 24 V DC 24 230 V AC / DC Pick up voltage max. 4.25 V DC 20.4 V AC / DC Drop-out voltage min. 1.5 V DC 7.2 V AC / DC Control current / power max. 25 ma at 4 V DC 6 ma / 1.5 VA at 24 V DC Response time max. ½ cycle 1 cycle Interlock delay time (min. / max.) 30 ms / 80 ms 60 ms / 150 ms EMC immunity Meets requirements of EN 60947-4-2 Functional description When control circuit A1 A2 is ON, the motor will rotate forward. With control circuit A3 A4 ON the motor will rotate in reverse direction. If both control circuits are switched ON the motor will rotate in the direction determined by the circuit which was switched ON first. A delay time (interlock) between forward and reverse running is incorporated. Danfoss DCS (mw) 2017.10 IC.PD.C50.D3.02 520B3036 2

Functional diagram Mains voltage (L1, L2, L3) Control voltage, F (A1, A2) Control voltage, R (A3, A4) Delay F-R Delay R-F Motor forward LED F Motor reverse LED R Wiring Motor overload and short circuit protection Motor full load current [A] Danfoss CTI 25M / CTI 25MB circuit breaker, code no. 0 0.16 047B3140 0.16 0.25 047B3141 0.25 0.4 047B3142 0.4 0.63 047B3143 0.63 1.0 047B3144 1.0 1.6 047B4145 1.6 2.5 047B3153 2.5 4.0 047B3154 4.0 6.3 047B3155 6.0 10.0 047B3156 Danfoss DCS (mw) 2017.10 IC.PD.C50.D3.02 520B3036 3

Dimensions Mounting The controller is designed for vertical mounting. If the controller is mounted horizontally the load current must be reduced by 50%. Controllers mounted side by side need no clearance. Controllers mounted vertically on top of another need a clearance of minimum 80 mm (3.15 in.). Clearance between controller top and ceiling and between controller bottom and floor must be at least 30 mm (1.2 in.) Danfoss DCS (mw) 2017.10 IC.PD.C50.D3.02 520B3036 4

Overheat protection If required the controller can be protected against overheating by inserting a thermostat in the slot on the right-hand side of the controller. Order: UP 62 thermostat 037N0050 The thermostat is connected in series with the control circuit of the main contactor. When the temperature of the heat sink exceeds 100 C the main contactor will be swtiched OFF. A manual reset is necessary to restart this circuit. For wiring connections see application examples. Application examples Combined reversing contactor and soft starter Soft start & soft stop A soft reversing of a motor can easily be achieved by connecting a reversing contactor to the soft starter. The reversing contactor, type RCI, will determine the direction of rotation, forward or reverse and the soft starter, type MCI, will perform soft starting and soft stopping of a motor. Soft start only If soft stop is not required, the application can be simplified by connecting the control circuit of the soft starter to the main terminals. A delay of approx. 0.5 sec. between forward and reverse control signal must be allowed to avoid influence from the voltage generated by the motor during turn-off. Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss DCS (mw) 2017.10 IC.PD.C50.D3.02 520B3036 5