Basic Gen-set Controller multi-line F SW version 2.31.X or later

Similar documents
SPARE PART ONLY. Basic Gen-set Controller Multi-line H SW version 2.31.X or later. Data sheet. Standard functions

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit

Automatic Gen-set Controller Multi-line D

Generator Protection Unit, GPU-3 DATA SHEET

Generator Protection Unit, GPU-3 DATA SHEET

Generator Controller GC-1F

Generator Paralleling Controller, GPC-3 DATA SHEET

PPM Protection and Power Management DATA SHEET

Generator Controller GC-1

No longer for sale. Generator Controller GC-1. Data sheet. Standard functions

Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

Engine Controller EC-1

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

AGC 200 Advanced Gen-set Controller DATA SHEET

Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

DATA SHEET Automatic Genset Controller, AGC-3

DATA SHEET Paralleling and Protection Unit, PPU-3

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

Generator Paralleling Controller, GPC-3 Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

Multiple Generator Automatic Synchronising System

AGC 200 Automatic Advanced Gen-set Controller DATA SHEET

DATA SHEET Genset Controller, GC-1F

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

DATA SHEET. AGC PM Automatic Genset Controller, Plant Management

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

PPU Power Management (PPM)

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Delomatic 4, DM-4 Marine & Offshore DATA SHEET

DATA SHEET Automatic Genset Controller, AGC-4

Delomatic 4, DM-4 Land DATA SHEET

DATA SHEET IOM 200 analogue interface for AGC 200

MIC-2 Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Engines & Gen-sets N, page 1 of 6

Installation Manual. Multi Power Controller MPC-1 multi-line D

DATA SHEET Selectable AC transducer, TAS-321 DG

INSTALLATION INSTRUCTIONS

DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description

DATA SHEET Selectable AC transducer, TAS-331DG

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

MULTI-LINE 2 APPLICATION NOTES

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

Automatic Sustainable Controller, ASC Mounting Board slot positions Terminal strip overview I/O lists Wiring

INSTALLATION INSTRUCTIONS

NOT RECOMMENDED FOR NEW DESIGNS

DEIF A/S. Description of options. Option P1, Event and alarm printer Automatic Gen-set Controller. Description of option. Functional description

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Option H3 Serial communication Profibus DP

DATA SHEET Compact Genset Controller, CGC 200

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

easygen- 3100XT/3200XT(-LT) Introduction Presentation

Engine & Genset Controls Z, page 1 of 12

MIC-2 MKII, Multi-instrument DATA SHEET

MULTI-LINE 2 APPLICATION NOTES. Converting PPM-2 to PPM-3 Parameter conversion Wiring Options I/O list Modbus. Document no.: A SW version:

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

TYPE APPROVAL CERTIFICATE

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

Comprehensive Modular Genset Controller

Option P1 Event and alarm printer Description of option Functional description Parameter list

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Genset control and protection with safety system

InteliNano NT. MRS Lite GEN-SET CONTROLLER. Description. Benefits

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

QUICK START GUIDE Paralleling and Protection Unit PPU 300

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

SIGMA. Advanced Generator Protection and Control. Short Form Catalogue

HT-DST4602 Evolution. Genset Controller. AMF and PARALLEL genset controller. Parallel Applications HUEGLI TECH SWITZERLAND

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

GC2000 Generator Controller Power Management and Protection

QUICK START GUIDE Paralleling and Protection Unit PPU 300

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

InteliLite NT SINGLE SET GEN-SET CONTROLLER. Description. Benefits

InteliNano NT GEN-SET CONTROLLER. Description. Benefits MEMBER

with Backlight Graphic LCD Screen

DEIF A/S. Description of options. Option H4 Serial comm. CAT CCM communication Multi-line 2 version 2. Description of option Functional description

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

GPM500 Generator Protection Module

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

InteliLite NT SINGLE SET GEN-SET CONTROLLER. Description. Benefits

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

InteliLite NT SINGLE SET GEN-SET CONTROLLER. Description. Benefits

Genset Controller Unit Model EMS - GC10. Installation Manual Section

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

QUICK START GUIDE Generator Protection Unit GPU 300

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

InteliLite SINGLE SET GEN-SET CONTROLLER. Description. Benefits

DEIF A/S. Description of options. Option C2, Generator add-on protection package Automatic Gen-set Controller. Description of option

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

InteliLite NT SINGLE SET GEN-SET CONTROLLER. Description. Benefits MEMBER

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

Transcription:

multi-line 2 492124027F SW version 2.1.X or later Standard functions DEIF A/S Applications AMF (no synchronising) Island mode (stand alone) Generator controls Engine start/stop Configurable start sequence Protection and I/Os (ANSI) Reverse power (2) Overcurrent, 2 levels (51) configurable VDO inputs 1-5 configurable digital inputs 1- configurable outputs Display Status texts Easily readable Password-protected setup Configurable views Complete alarm list Event log (150 events) Language configuration M-logic Simple logic configuration tool Selectable input events Selectable output commands Measurement system -phase true RMS (100-480V AC) Supports delta V applications -/1 and -/5A AC 100-25000V AC trafo ratios Breaker types Contactor Circuit breaker Compact breaker General Approval: Gost-R PC software available Additional functions available Additional applications available Additional I/Os available DEIF A/S

Application The is a microprocessorbased control unit containing all necessary functions for control and protection of a gen-set and control of mains and generator breaker. The standard control functions include start and stop sequences for the engine, but regulation control is also possible. The BGC contains all necessary -phase measuring circuits and all values and alarms are presented on the LCD display. The BGC is a compact all-in-one unit designed for the following standard and al applications: Standard applications: (no synchronising) 1. Automatic mains failure (no back sync.) 2. Island operation Optional applications: (synchronising). Multiple gen-sets, load sharing 4. Peak shaving 5. Fixed power to mains 6. Automatic mains failure (back sync.) 7. Load take over The al applications require governor/avr control for parallel operation. ( G2 or G). The generator and mains breaker types can be configured to be either a circuit breaker, a contactor or the compact breaker which requires a signal to reset the breaker from tripped to open position. Governor and AVR control Speed governor control and automatic voltage regulation are al functions and can be analogue or digital. (Both digital AVR + GOV outputs requires a total of 4 relay outputs. Note that -1 relays are available depending on s and breaker selection. Setup Setup is easily done via a menu structure in the display (password protected, levels) or via the RJ45/RS22 PC connection and the multi-line 2 Windows based PC utility software. The PC interface box needed for this operation is al equipment for the BGC. The utility software offers additional features such as monitoring of all relevant information during commissioning, saving and downloading of settings and downloading of software updates. Options In order to perfectly match the product solution to specific applications, the functionality of the BGC can be equipped with a number of available s. The s selected by the customer will be integrated in the standard BGC hereby securing the same user interface unaffected by whether the application needs a highly complex or a more basic gen-set controller. Display variants Two display variants are available for the BGC unit. The unit is normally supplied with the AMF folio. AMF folio Configurable inputs/outputs: The BGC is supplied with a standard number of inputs and outputs that can be used for control and/or protection purposes. The number of configurable I/Os depends on the used breaker type. The table only shows available I/Os for the standard unit (no hardware s are selected.) This means that additional I/Os can be selected (please refer to the list for more). PCB Circuit Compact Contactor I/O breaker breaker MPU (Tacho) 1 1 1 Digital inputs 9 (5) 9 (7) 9 (5) VDO Relay outputs 9 (1) 9 () 9 (1) If the unit is used in island applications, the island folio is selectable (Specify Y1). Island folio The number in parenthesis indicates the number of user configurable digital inputs/relay outputs. (Horn output, start/stop functionality and breaker handling occupies the I/Os not freely configurable). Additional I/Os can be selected. Example: BGC - M1.2 - M14. gives an additional 7 digital inputs/4 digital outputs. Please see the list and hardware overview in this data sheet. DEIF A/S Page 2 of 10

Single line application diagrams Standard Automatic mains failure (no back sync.) (1) Island operation (2) DEIF A/S Page of 10

Optional Multiple gen-sets, load sharing () Peak shaving, load take over (4/7) Fixed power to mains (5) Automatic mains failure (back sync.) (6) DEIF A/S Page 4 of 10

Available s Option slot #4 is allocated to s G2 and G only. The two remaining slots (#2 and #) can hold a maximum of two hardware s per unit. Option Description Type Note A Loss of mains protection package B C D A1 Over- and undervoltage (generator and busbar/mains) (27/59) Over- and underfrequency (generator and busbar/mains) (81) Vector jump (78) df/dt (ROCOF) (81) A2 Over- and undervoltage (generator and busbar/mains) (27/59) Over- and underfrequency (generator and busbar/mains) (81) df/dt (ROCOF) (81) A Over- and undervoltage (generator and busbar/mains) (27/59) Over- and underfrequency (generator and busbar/mains) (81) Vector jump (78) Generator/busbar/mains protection package B1 Over- and undervoltage (generator and busbar/mains) (27/59) Over- and underfrequency (generator and busbar/mains) (81) Generator add-on protection package C1 Over- and undervoltage (generator) (27/59) Over- and underfrequency (generator) (81) Overload (2) Short circuit (50) Current unbalance (46) Voltage asymmetry (47) Reactive power import (excitation loss) (40) Reactive power export (overexcitation) (40) Voltage/var/PF control D1 Selection between: Constant voltage control (stand-alone) Constant power factor control (parallel with mains) Reactive load sharing (island paralleling with other generators) Constant reactive power control (parallel with mains (with H2/H)) Software Software Software Software Software Software Option D1 requires G2 or G See note below D2 Constant voltage (stand-alone/sync.) Software Option D2 requires G2 or G See note below F G Analogue transducer outputs F1 2 transducer outputs, 0...20mA or 4...20mA Hardware F2 4 transducer outputs, 0...20mA or 4...20mA Hardware Control functions G1 2 load-dependent relays (high load/low load) Hardware G2 Synchronising with analogue lines Hardware (Option included in G) Two boards occupied - see hardware overview Option M14.X (relay outputs) is included Two other hardware s available G Synchronising with analogue lines and kw load sharing (G includes all functionality contained in G2) Hardware Parallel mains operation Two other hardware s available Parallel mains operation/ parallel DG operation Note regarding D1 and D2: Analogue output for AVR is included on terminals 6/64. When relay control is needed please check the I/O list to ensure that a sufficient number of relays are available. D1 or D2 follows G2/G and -5 relays are available depending on the breaker configuration. Option M14.X offers extra relay outputs that can be used for controlling of the governor and AVR. DEIF A/S Page 5 of 10

Available s (continued from page 5) Option Description Type Note H Serial communication H1 CAN-open Hardware H2 Modbus RTU Hardware H Profibus DP Hardware H4 CAT CCM Hardware H5 CAN-bus (J199 + MTU) engine communication: MTU MDEC Scania EMS 1&2 Detroit Diesel DDEC Volvo Penta EMS 1&2 Deutz EMR John Deere JDEC Hardware J H6 Cummins ECM (RS485) engine communication Hardware Cables J5 BGC converter box kit Other K1 Designer s reference handbook (hard copy) Other CD rom encl. at delivery L Gasket Other Display IP 54 M Y Configurable I/O extension cards M1.X 7 binary inputs, configurable Hardware 2M1 14 binary inputs Hardware M14.X 4 relay outputs Hardware 2M14 8 relay outputs Hardware M15 4 analogue inputs, configurable, 4...20mA Hardware Display layout Y1 BGC display for island operation (no mains breaker) Hardware (ANSI# as per IEEE Std C7.2-1996(R2001) in parenthesis). Can be placed in both slot 2 and if 14 extra binary inputs are needed Same as M1.2/M1. Occupies slot 2 and Can be placed in both slot 2 and if 8 extra relay outputs are needed Same as M14.2/M14. Occupies slot 2 and Specification of s M1.X and M14.X:.X signifies the slot position. M1.2 therefore means that this is placed in slot #2 and M1. means that this is placed in slot #. DEIF A/S Page 6 of 10

Hardware overview There can only be one hardware in each slot. This means that slot 2 and can hold one or two s only, never three. Example given: G1 and F1 can be ordered but not G1, F1 and H1. Besides the hardware s shown on this page, it is possible to select the software s mentioned in the s overview. Standard: Slot #1, term. 1-46 Power supply/i/os AC measurements DC supply Digital I/Os VDO inputs RPM (tacho) input Slot #2, term. 47-54 Slot #, term. 55-6 Option (hardware) Option F1: 2 transducer outputs, 0-20/4-20mA Option F2: 4 transducer outputs, 0-20/4-20mA Occupies slot 2 and slot Option G1: 2 x relay outputs for load dep. start/stop SLOT # 1 SLOT # 2 SLOT # SLOT # 4 Option H1: Option H2: CAN-open Modbus RTU 1 6 7 11 12 16 17 20 47 54 55 62 6 80 Option H: Option H4: Option H5: Option H6: Option M1.X: Option M14.X: Profibus DP CAT CCM CANbus (J199+MTU) Cummins ECM 7 binary inputs, configurable 4 relay outputs Option M15: 4 analogue inputs Configurable, 4-20mA Option 2M1: 14 binary inputs Occupies slot 2 and slot Option 2M14: 4 relay outputs, Occupies slot 2 and slot 21 4 46 M1.X and M14.X: -X indicates slot position. (Can be selected for slot #2 and slot # at the same time). Slot #4, term. 6-80 Synchronising/regulation RJ45 connection PC service port, J5 PC interface: Converter box complete with cables Option G2: Option G: Synchronising and governor control (No load sharing) Synchronising and governor control (load sharing) DEIF A/S Page 7 of 10

0.6 ud 0.6 ud 1 1 0.6 ind 0.6 ind 0 0 500 500 1000 1000 + + - - Data sheet Principle diagram PF kw PF kw DEIF supplies a complete range of current transformers (MAK range of CTs), power supplies (DCP range), meters (DQ range) and transducers (TAS range) that are suitable for use with our range of generator controls and protection relays - please see www.deif.com for full details. DEIF A/S Page 8 of 10

Technical specifications Accuracy: Class 1.0, to IEC 688 Short circuit: 5% of 50% * I N Analogue outputs: Class 1 of acc. to max. range Acc. to IEC688 Operating temp.: -25-70 ο C (-1-158 ο F) Galvanic separation: Between AC voltage, AC current and other I/Os: 2200V AC, 50Hz, 1 min. Between analogue outputs: 500V DC, 1 min. Meas. voltage: 100-480V AC +/-20% Consumption: Max. 0.15VA/phase Load sharing lines: +/-5V DC Impedance: 2.5kΩ Analogue outputs: 0(4)-20mA (transducer) and +/-25mA (regulation) Galvanically separated Active output (internal supply) Load max. 500Ω Safety: To EN 61010-1, installation category (overvoltage category) III, 600V, pollution degree 2 Protection: Unit: IP20 Display: IP52 (IP54 with gasket L) Acc. to IEC529 and EN 60529 EMC/CE: To EN 61000-6-1/2 SS46150 (PL4) and IEC 255- Meas. current: -/1 or -/5A AC VDO inputs: Resistor inputs, internal supply Consumption: Current overload: Meas. frequency: Max. 0.VA/phase 4 x I n continuously 20 x I n, 10 sec. (max. 75A) 80 x I n, 1 sec. (max. 00A) 0-70Hz Aux. supply: 12/24V DC, -25/+0% Max. 8W consumption Binary inputs: Bi-directional optocoupler ON: 5-6V DC OFF: <2V DC Impedance max. 4.7kΩ Material: Plug connections: PC: Approval: Weight: All plastic materials are selfextinguishing according to UL94 (V1) AC current: 4 mm 2 multi stranded Other: 2.5 mm 2 multi stranded RS22 converter box ( J5) Gost-R (Russia) Approx. 1 kg (2.2 lbs) Relay outputs: Analogue inputs: Mounting: 250V AC / 8A or 24V DC / 2A +/-10V DC Not galvanically separated Impedance: 100kΩ 4-20mA inputs: Impedance: 50Ω Not galvanically separated MPU (tacho): 2-70V AC, 10-10000Hz, Impedance: 200kΩ Panel mounted Climate: Class HSE, to DIN 40040 Response times: Busbar 1 and 2: Over-/undervoltage Over-/underfrequency Generator: Reverse power: Overcurrent: Fast overcurrent: Over-/undervoltage: Over-/underfrequency: Overload 1/Overload 2: Current unbalance: Voltage unbalance: React. power import: React. power export: Mains: ROCOF: Vector jump <50 ms <50 ms <00 ms <250 ms <40 ms <00 ms <00 ms <1100/00 ms <00 ms <00 ms <00 ms <00 ms 10 ms (4 periods) <20 ms DEIF A/S Page 9 of 10

Unit dimensions in mm (inches) Panel cutout: H x W = 86 x 208 (.86 x 8.190) Display size: H x W = 129 x 248 (5.079 x 9.764) 207 (8.150) 248 (9.764) 86 (.86) 129 (5.079) 148 (5.827) 158 (6.220) Order specifications DEIF A/S, Frisenborgvej DK-7800 Skive, Denmark Due to our continuous development we reserve the right to supply equipment which may vary from the described. Tel.: +45 9614 9614, Fax: +45 9614 9615 E-mail: deif@deif.com, URL: www.deif.com