M-series Intrinsically Safe I/O

Similar documents
M-series Foundation Fieldbus I/O

DeltaV M-series I/O Subsystem Horizontal Carriers

M-series Traditional I/O

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

S-series Foundation Fieldbus I/O

S-series Mass Connection Solutions

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies

S-series Horizontal Carriers

DeltaV SIS Conditioning Components

S-series Sequence of Events Card

DeltaV VerticalPlus I/O Subsystem Carriers

M-series DC to DC Power Supply

DeltaV M-series Traditional I/O

DeltaV M-series Traditional I/O

DeltaV M-series Traditional I/O

S-series H1 I/O Card with Integrated Power

M-series MQ Controller

M-series MX Controller

M-series Profibus DP Series 2 Plus Interface Card

S-series DeviceNet Interface Card

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

M-series I/O Subsystem Horizontal Carriers

DeltaV SIS TMConditioning Components

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

DeltaV S-series Traditional I/O

DeltaV Electronic Marshalling for Migrations

S-Series DeltaV Controller Interface for PROVOX I/O

M-series DeltaV Controller Interface for RS3 I/O

M-series Profibus DP Series 2 Plus Interface Card

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

S-series Horizontal Carriers

S-series Sequence of Events Card

M-series DeltaV Controller Interface for PROVOX I/O

M-series Serial Interface Series 2

Introduction. DeltaV Product Data Sheet February 2016 Page 1. M-series MX Controller. Right-sized controllers. Easy to use

S-series Electronic Marshalling for Migrations

M-series MQ Controller

DeltaV SD Plus Controller

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

S-series Electronic Marshalling

S-series IS Electronic Marshalling

M-series Virtual I/O Module 2

S-series DeviceNet Interface Card

S-series Profibus DP Interface Card

S-series Serial Interface

S-series Electronic Marshalling

DeltaV IS Electronic Marshalling

DeltaV Ethernet I/O Card

S-series Electronic Marshalling

S-series Virtual I/O Module 2

M-series Virtual I/O Module 2

S-series Virtual I/O Module 2

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

DeltaV Electronic Marshalling

Ethernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging

S-series IS Electronic Marshalling

S-series Ethernet I/O Card

CSI 9330 Vibration Transmitter

S-series Serial Interface

M-series Serial Interface Series 2

DeltaV Control Network Hardware

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DeltaV Wireless I/O Card

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

DeltaV Virtual IO Module Network Gateway

MTL8000-2/x Series Modular I/O

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Valve and Case Expansion Monitor Specifications

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

ControlWave Micro Digital Input / Output Modules

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

VariTrans P The Problem The variety of tasks results in a large number of different devices.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

ROC800-Series Thermocouple Module

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

FLEX Ex Spring Clamp Terminal Base

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

DeltaV Safety Instrumented System (SIS) with Electronic Marshalling

Intrinsically Safe Barriers

CTO CSLS CHARM Cabinets

Operating Instructions

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Fast Control Response Requirement

Isolated Process Current Input with Loop Power 7B35

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

APPLICATION GUIDE. Interface Modules IM Series.

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

DeltaV Distributed Control System Product Data Sheet M-series Intrinsically Safe I/O Features full system modularity Reduces system footprint Decreases installation time and expense Plug-and-play installation saves money Phased installation saves time Easy to use This fail-safe design enables you to initially install I.S. DeltaV M-series Intrinsically Safe I/O makes your I.S. installations easy and compact. Real-time, online equipment additions Introduction DeltaV M-series Intrinsically Safe Input/Output (I.S. I/O) provides the perfect solution to the precarious situation of running I/O in hazardous areas. DeltaV I.S. I/O is a distributed I/O system capable of withstanding Class I Division 2 and IEC Zone II environmental conditions. The I.S. I/O subsystem connects field circuits and field devices to the DeltaV system. Intrinsically safe field circuits and field devices can enter Class I Division 1, Zone 1, and Zone 0. The DeltaV I.S. I/O supports industry-standard AI, AO, DI, and DO, applications. Benefits Features full system modularity. The I.S. I/O subsystem was designed to optimize your automation investment. All components are fully modular and installable under power. You add I/O interface carriers and I/O interfaces in groups of 8 channels, as you need them. The modular design enables you to buy the exact amount of I/O cards and power/controllers that you need. Add more DeltaV I/O as your system grows. Reduces system footprint. The state-of-the-art form factor design of the DeltaV I/O components enables you to mount the I/O interface carrier in a junction box in the field. You significantly reduce the footprint of your equipment and free up valuable control room space for other uses. Decreases installation time and expense. DeltaV Intrinsically Safe I/O are native DeltaV I/O cards that are part of the controller s I/O subsystem. This eliminates the need for third party barriers or interface mapping. Save even further on wiring expenses by installing I.S. I/O in the field, close to the actual field devices. Mounting the controller with the I/O further reduces your wiring expenditures by eliminating the need for long runs of multi-cores. Plug-and-play installation saves money. We talked to customers like you to find out what you wanted in an I/O system. We designed and produced exactly what you wanted. The I.S. I/O subsystem is easy to use. All I.S. I/O components plug into the I/O interface carrier. You can install the I/O interface carriers to manage anticipated growth, without purchasing the I/O interfaces until you re ready to install your additional field devices. Phased installation saves time. Mount the I/O interface carrier and you are ready to begin installing the field devices. I/O terminal blocks plug directly onto the I/O interface carrier there s no need to have the I/O cards installed. Easy to use. I.S. I/O interfaces and terminal blocks have I/O function keys. These keys ensure that the correct I/O card is always plugged into the corresponding terminal block easy!

This fail-safe design enables you to initially install I.S. I/O quickly and efficiently. When you need to replace an I/O card the function key design ensures that you will always install it correctly. DeltaV I.S. I/O easy to install and maintain. Real-time, online equipment additions. Online addition of new I/O interfaces means your process does not get interrupted. As new equipment is added, DeltaV Explorer acknowledges it and assigns it basic configuration. Product Description A variety of analog and discrete I/O cards are available to meet your specific requirements. All I/O cards are enclosed in a common form factor that plugs into the I/O interface carrier. The housing is clearly labeled with the I/O card type. Clearly visible LEDs on the top of the I/O card display the power, error, and status to the channels included in the I/O card. (It is important to note that, when connecting standard I/O carriers to I.S.I/O carriers, more standard I.O. carriers may not be added after I.S. carriers the I.S.I/O carriers must always be mounted last in line.) Hardware Specifications Category Common Environmental Specifications for all I/O Interfaces Operating temperature -40 to 60 C (-40 to 140 F) Storage temperature -40 to 85 C (-40 to 185 F) Relative humidity Airborne contaminants Protection rating IP 20 Hazardous area/location* I/O Interfaces Field circuits Shock Vibration Dimensions 5 to 95%, non-condensing Specifications ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating CENELEC Zone 2 IIC T4 hazardous area Class I, Div 2, Groups A. B, C, D T4 hazardous locations. CENELEC Zone 0, IIC hazardous area or Class 1, Div 1, Groups A,B,C,D hazardous locations 10 g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 to 16 Hz; 0.5 g from 16 to 150 Hz H 10.7 cm (4.2 in.) W 4.1 cm (1.6 in.) Depth 10.5 cm (4.1 in.) www.emerson.com/deltav 2

*Refer to Zone 0 installation instructions (12P1990) for information on installing in hazardous areas. Intrinsically Safe Analog I/O Cards Specifications for DeltaV I.S. I/O AI, 4 to 20 ma with HART Number of channels 8 Isolation LocalBus to any channel Between channels I. S. Channel to non-i. S. LocalBus Nominal signal range (span) Full signal range LocalBus current (12 VDC nominal) per card Line fault detection short circuit current open circuit current Resolution Calibration Optional loop disconnect Voltage to transmitter @ 20 ma 60 VAC 250 VAC 4 to 20 ma 2 to 22 ma, 600 ma >21.5 ma < 0.5 ma 16 bits required Yes 15 V (min) Temperature stability ±0.006% of span per C Specifications for DeltaV I.S. I/O AO, 4 to 20 ma with HART Number of channels 8 Isolation LocalBus to any channel Between channels I. S. channel to non-i. S. LocalBus Nominal signal range (span) Full signal range LocalBus current (12 VDC nominal) per card Open circuit detection threshold Resolution Calibration Optional loop disconnect Voltage to load Load resistance 60 VAC 250 VAC 4 to 20 ma 1 to 22 ma, 630 ma (typical) 0.7 ma ±0.2 ma 12 bits required Yes 13 V (min) @ 20 ma 650 Ω max. Temperature stability ±0.006% of span per C www.emerson.com/deltav 3

Intrinsically Safe Discrete I/O Cards Specifications for DeltaV I.S. I/O DI Number of channels 16 Isolation LocalBus to any channel Between channels I. S. Channel to non-i. S. LocalBus Detection level for On Detection level for Off Output Impedance LocalBus current (12 VDC nominal) per card Switching hysteresis 60 VAC 250 VAC >2.1 ma <1.2 ma 100 Ω @ >6 ma (wetting current) 350 ma 200 µa nominal Applicable specifications NAMUR, DIN 19234 Voltage applied to sensor 7.0 to 9.0 V from 1 k Ω ±10% Line fault detection short circuit open circuit Maximum input frequency in pulse counting mode Minimum pulse width detected Optional loop disconnect < 100 Ω > 50 k Ω 20 Hz 45 ms No www.emerson.com/deltav 4

Specifications for DeltaV I.S. I/O DO Number of channels 4 Isolation LocalBus to any channel Between channels I. S. Channel to non-i. S. LocalBus Output range Off state leakage LocalBus current (12 VDC nominal) per card Field circuit power per card Discrete Output Momentary Output Continuous Pulse Output Configurable channel types: 60 VAC 250 VAC 22 V 11 V @ 45 ma load 25 V maximum N/A 560 ma Output Output stays in last state submitted by the controller. Output is active for a pre-configured time period (100 ms to 100 s). Output is active as a percentage of a pre-configured base time period (100 ms to 100 s). Resolution = 5 ms Minimum output voltage 22 V (open circuit) 11 V at 45 ma Maximum output voltage Current limit per channel Output supply ripple Optional loop disconnect 25 V 45 ma (min) <0.5% of output (peak to peak) Yes www.emerson.com/deltav 5

Intrinsically Safe Power Supply The intrinsically safe power supply accepts 24 VDC power and converts it to 12 VDC to power the DeltaV I.S. I/O cards. The number of I/O cards that can be powered by a single Intrinsically Safe Power Supply depends on the I. S. I/O card type. Optional power supply redundancy is supported by adding power supplies at a rate of n + 1. The following table gives the specifications for the DeltaV I.S. I/O Power Supply. Input voltage Output current I.S. I/O Power Supply Specifications 18.5 36 VDC Output voltage 12 VDC ±5% Input protection Input/output isolation Input connection Cable size 5A Internally fused, non-replaceable 250 V ac rms (tested at 1,500 V ac rms) 2 part screw terminal, each duplicated 2.5 mm2 Overvoltage protection Output protected at 110% to 120% Operating temperature optimum orientation (full load) worst case orientation Storage temperature Relative humidity Airborne contaminants 0 to 55 C (32 to 131 F) 0 to 50 C (32 to 122 F) -40 to +85 C (-40 to 185 F) 5 to 95%, non-condensing ISA-S71.04-1985 airborne contaminants class G3 Shock 10 g, 11 ms pulse width, to BS EN 60 068-2-27 Vibration 2 g @ 10-100 Hz to BS IN60 068-2-6 and BS 2011 part 2.1 Mounting Green DC Power Primary power LED Indicators: External connectors: On either slot of 2-wide power/controller carrier Input DC power is applied and internal fuse/diode is sound. DC input, 3-wire www.emerson.com/deltav 6

LocalBus Isolator The DeltaV LocalBus Isolator protects the I.S. I/O from fault voltages from AC main power supplies. The LocalBus Isolator also links intrinsically safe I/O with non-intrinsically-safe I/O. The following table gives the specifications for the DeltaV LocalBus Isolator. LocalBus Isolator Specifications Height 11.0 4.3 Width 4.2 1.7 Depth 16.0 6.2 Weight 250 grams 8.7 oz Carriers All DeltaV I.S. I/O cards are contained in modular 8-wide carriers. Connect the carriers in the most efficient configuration for your plant. The carriers have multi-pin connectors to ensure that I.S. I/O is never connected to non-i.s. I/O. Power supplies for I.S. I/O modules using field wiring have their own modular carriers. These carriers connect between the I/O carriers. Use a LocalBus isolator to connect I.S. I/O with non-i.s. field wiring. The LocalBus isolator resides on its own carrier. Carrier Specifications Relative humidity Airborne contaminants Category Common Environmental Specifications for all Carriers 5 to 95% RH, non-condensing Protection rating IP 20, NEMA 12 Shock Vibration Hazardous area/location* Applicable standards Specifications ISA-S71.04-1985 Airborne Contaminants Class G3 10 g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 to 16 Hz; 0.5 g from 16 to 150 Hz CENELEC Zone 2 IIC T4 hazardous areas Class I, Div 2, Groups A, B, C, D T4 hazardous locations. Factory Mutual Research Co., Class I Div 2, Groups A-D hazardous locations. EN 50 014: 1992 electrical apparatus for potentially explosive atmospheres, general requirements. EN 50 020: 1995 Electrical apparatus for potentially explosive atmospheres, intrinsically safe i. EC directive 94/9/EC (ATEX 100A) www.emerson.com/deltav 7

*Refer to Zone 0 installation instructions (12P1990) for information on installing in hazardous areas. 8-Wide I.S. I/O Carrier Specifications Capacity Eight I/O cards and eight terminal blocks Height 16.5 6.5 Width 33.6 13.2 Depth 3.1 1.2 I.S. I/O Power Supply Carrier Specifications Capacity One I.S. power supply Height 16.5 6.5 Width 8.4 3.3 Depth 3.1 1.2 LocalBus Isolator Carrier Specifications Capacity One LocalBus Isolator Height 16.5 6.5 Width 8.4 3.3 Depth 3.1 1.2 I.S. 1-wide Carrier Extender (Left and Right) Specifications Capacity Single cable Height 16.5 6.5 Width 4.2 1.7 Depth 3.1 1.2 www.emerson.com/deltav 8

System Compatibility M-series I/O cards are not compatible with S-series Controllers and Carriers. Ordering Information Description 8-channel AI, 4-20 ma with HART with I/O term block with loop disconnect term block 8-channel AO, 4-20 ma with HART with I/O term block with loop disconnect term block 16-channel DI, switch/proximity detector 4-channel, DO, solenoid driver, IIC Gas Groups with I/O term block with loop disconnect term block 8-wide carrier without carrier extension cable with carrier extension cable VE4012S2B1 VE4012S2B2 VE4013S2B1 VE4013S2B2 VE4010B1 VE4011B1 VE4011B2 VE4060C0 VE4060C1 24 VDC input I/O module supply and carrier VE5010 LocalBus isolator and carrier VE4070 Model Number Emerson North America, Latin America: +1 800 833 8314 or +1 512 832 3774 Asia Pacific: +65 6777 8211 Europe, Middle East: +41 41 768 6111 www.emerson.com/deltav 2017, Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. The DeltaV logo is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.