Agilent IO Libraries L.02.xx or higher

Similar documents
Procedure to set up an HPIB 82350B card on an M57. M58 or C20x PC. Table 1: Parts required. Part Number Description Qty

Agilent E2094M IO Libraries

HP / HP HPIB Driver Installation and Troubleshooting ChemStation Version A.07.0x- A.08.0xon Windows NT

Agilent G1732AA MSD Security ChemStation

CD-ROM Image Viewer Installation Guide M&T Bank. Member FDIC.

82341C HPIB Installation and Troubleshooting Agilent ChemStations on Windows 95 and Windows NT

This is a GENERAL Servant Keeper Network Installation help sheet. If you need further assistance, please contact your network administrator.

Agilent G1701DA MSD Productivity ChemStation Software

Before you attempt to upgrade from the Live200 system to LiveLAN 3.1, make sure that you have the following:

Agilent ChemStation for GC Systems

HP G1701BA Productivity ChemStation Software. Installation Manual

Registering Your D1 with the System (Windows 2000)

SMT107 User Manual User Manual (QCF42); Version 3.0, 8/11/00; Sundance Multiprocessor Technology Ltd. 1999

Installation of fi-4110cu Scanner under Windows 2000

Agilent G1701DA MSD Productivity ChemStation Software

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory Installation & Administration Guide Version

This document provides additional information for the installation and use of the Keithley I/O Layer.

Sound Card Installation for Windows 95/98

MF9300. Software setup guide

4190 Information Management System (IMS) Software Upgrade Instructions

Windows XP Professional Configuration

1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically.

KLAS v7 Workstation Installation Self-Hosted Progress Version 10.2B / Windows 7

USB driver and Software Installation. UPS Monitoring and Management Software

Copyright Autodesk, Inc.

Thuraya SG-2520 Software Upgrade Manual

System Requirements. Package Contents

DCN Software Installation Instructions. en Software Installation Instructions

USB-MIDI Driver installation and settings...1 Windows XP users... 1

Agilent OpenLAB Chromatography Data System (CDS)

Quick Install Guide. Wireless-G Network PCI Adapter. WLP54G 3a

Windows XP Professional Configuration

HDI HP-GL/2 Driver for AutoCAD Getting Started

Installing Intellicus DotNet Client on Windows. Version: 16.0

Sage Fixed Assets Lite Depreciation for Sage 50 - U.S. Edition

Windows NT Server Printer Driver Upgrade Instructions

Chapter 5. Driver Installation. 5-1 Intel Software Installation Utility. Driver Installation. 2. Click Intel Chipset Software Installation Utility.

JPRO Fleet Service Portal User s Guide

Sage Fixed Assets. Network Installation Guide for Administrators. for Depreciation, Tracking, Planning, and Reporting

Agilent Dissolution Tester Driver

FAS Asset Accounting FAS Asset Inventory FAS CIP Accounting Network Installation & Administration Guide Version

Installation Guide V1.1

How do I apply the patch files?

Mercury QuickTest Professional. Installation Guide Version 9.0

Sage Fixed Assets Lite Depreciation for Sage 50 - U.S. Edition. Quick start guide

Agilent OpenLAB Chromatography Data System (CDS)

Online Update Procedure

Removing Norton Internet Security or Norton Personal Firewall 2004 from Windows XP/2000 after Add/Remove Programs does not work

PCI RadioLINK. FM Radio with Digital Turning. User Manual

3. IMPORTANT: When prompted, accept the default Installation directory.

Quick Reference Guide Updating Anti-Virus to Microsoft Security Essentials. Check for McAfee EPO Agent

NET-DYN USB Dual Band (Mediatek) Installation Guide. This manual is divided into three parts: Windows XP, Windows 7 / 8 / 8.

FAS 50 Asset Accounting - Peachtree Edition. Quick Start Guide Version

Installing the Driver

T E KLYNX BACKTRACK V E R S I O N 6 I N S T A L L A T I O N G U I D E

Windows 2000/XP Network

Network Device Installation Software DeviceInstaller

Sage Fixed Assets Network Installation Guide

Galileo Desktop SM 2.1. Installation Guide

Note that if the downloadable distribution file is provided to you by an HP representative, you can skip the downloading steps in this README.

Sage Fixed Assets Network

Sage Fixed Assets Single User. Installation guide

SoftPro Installation Guide

Sage Fixed Assets Lite Depreciation

INTRODUCTION...1. Under Windows 98SE... 2 Under Windows ME... 6 Under Windows Under Windows XP...10

B MP45 Driver installation Windows Vista, page 8 D Uninstall MP45 Driver Windows Vista, page 14

SD007-PFX (BPChecker3000) Ver. 2 Update Manual

ehealth Integration for HP OpenView User Guide

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version

QN-USB-Cable Driverinstallation (Windows XP)

Sage Fixed Assets Network. Installation guide

Magic Card Professional

Agilent ChemStation. ECM Interface Guide. Agilent Technologies

NiceLabel Suite. Installation guide. Euro Plus d.o.o. English Edition. Version

Sage Fixed Assets Single User

Inmagic Content Server Standard Version 9.00 Installation Notes for New and Upgrade Installations

Inmagic Content Server Workgroup Version 9.00 Installation Notes for New and Upgrade Installations

Before Installing the Software


Client Data System. Upgrade Guide. CDS v4.0 to v Client Data System Upgrade Guide v4.0 to v4.1.1 Revised:

Getting Started. ContrexHost 3. Suite of Serial Communications Applications for Contrex Motion Controls

AUA DuoConnect for Notebooks. Installation Guide

FAS 50 Asset Accounting Quick Start Guide

Installing the Cisco Unified MeetingPlace Web Server Software

RTE for WIN32. Installation Manual (Rev.7.0) Midas lab

1. Contents. b. Windows ME

NEC Versa 500D/550D Windows 98 Upgrade Information

CellSync Manager. User Manual F8V7D006-SS F8V7D008-SS. Get online and synchronize anywhere. Web Access. Phone Book Manager

HiCOCAN. Setup Information

Océ Windows Raster Driver 2. Getting Started

Galileo Print Manager Installation Guide

Lite Depreciation Quick Start Guide

PropertyBoss Upgrade

Sage Fixed Assets Lite Depreciation. Quick start guide

Agilent 89600B VSA. Software Installation Guide

Inmagic Content Server Enterprise Inmagic Content Server Standard Version 1.3 Installation Notes

HP Travel Phone User s Guide

BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING

Galileo Print Manager Installation Guide

Transcription:

Installation Instructions for use with the Agilent ChemStation After installing the GPIB 82350A or 82350B board in the computer, it is necessary to install or upgrade the corresponding driver and configuration software, located in the \GPIB directory on the Agilent ChemStation CD-ROM or the Agilent GP-IB Libraries for Instrument control CD-ROM. To install the I/O Libraries proceed according to the steps described in this note. The Agilent ChemStation B.01.01 and greater requires version L.02.01.00 of the I/O Libraries. These libraries are supported under both Windows 2000 Professional and Windows XP Professional. Be sure to follow the correct installation description. Contents: Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional 2 Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional 12 Upgrading Existing IO Libraries 22 Working with your Agilent IO Libraries 27 What has been changed by the Installation? 27 Troubleshooting 28 Agilent Technologies

Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional Installing New IO Libraries 1 Turn the Computer ON. As Windows 2000 Professional starts, the Found New Hardware Wizard will start. At this moment, select Cancel. (See Figure 2) Figure 1 Found New Hardware Wizard opens 2 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional Figure 2 Found New Hardware Wizard 2 Using the Windows Explorer, locate and start Iolibs.exe in the \GPIB directory of your ChemStation CD-ROM. Follow the instructions in the installation Wizard. This will install the Standard Interface Control Library (SICL) on your computer, update the registry and add a new Program Group called Agilent I/O Libraries. The InstallShield Wizard opens and starts the IO Libraries installation. Figure 3 Install Shield Wizard Agilent IO Libraries L.02.xx or higher - Installation Instructions 3

Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional 3 When the title screen appears (see Figure 4), click Next to go the License Agreement screen and then click Yes to accept the licenses terms and to display the Readme Information. Figure 4 Installation screen IO Libraries 4 Click Next to display the Select Type of Installation screen. 4 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional 5 Choose installation option Full Installation, for an installation of both the SICL libraries and VISA components. The System will go to the next screen and display the current settings. (see Figure 5) Figure 5 Installation options 6 By default SICL is installed in C:\Program Files\Agilent\IO libraries. VISA is installed by default in C:\Program Files\VISA\winnt. Click Next if you accept the default setting, or go back to set the directory you want via Custom Installation option. By clicking Next the IO Libraries will be installed. Agilent IO Libraries L.02.xx or higher - Installation Instructions 5

Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional 7 The IO Libraries has been successful installed now. Finish the installation without viewing the Readme file and without running the IO Conifg. Leave the screen with Finish and reboot the system. 8 As Windows 2000 starts after power cycling, the Found New Hardware Wizard will start again. This time click Next (See Figure 6) Figure 6 Found New Hardware Wizard 6 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional 9 Select Option 2 and click Next (See Figure 7). Figure 7 Install Hardware Device Drivers Agilent IO Libraries L.02.xx or higher - Installation Instructions 7

Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional 10 Click Next and the installation will start. (See Figure 8). Figure 8 Select a Device Driver 8 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional 11 Select Finish. (See Figure 9) Figure 9 Finishing installation GPIB 12 Start the IO Config Utility by clicking in the Icon and choose Run IO Config. 13 From the list of available interface types choose the appropriate one, i.e. 82350 PCI GPIB in case you have the Agilent 82350 board installed (see Figure 10) Agilent IO Libraries L.02.xx or higher - Installation Instructions 9

Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional Figure 10 IO Libraries Configuration 14 Select Configure. The configuration utility, now attempts to detect the selected GPIB interface in the PC in order to assign the correct resources to the card. 10 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Configuring the Agilent 82350 GPIB Interface Drivers under Windows 2000 Professional 15 Set the SICL Interface Name to hp82341, the Bus Address to 30 and the System Controller flag as shown in Figure 11. Please note that the appearance of the dialog slightly differs depending on the type of GPIB board installed. NOTE. You need to type in the SICL interface name hp82341 with lower case letters for both cards. Figure 11 Configuring GBIB Cards 16 Select OK. The configured GPIB board should now be listed under Configured Interfaces in the Interface Configuration Screen. Close the window by clicking OK. The installation is complete. Note that you must re-start to initialize the IO Libraries. Agilent IO Libraries L.02.xx or higher - Installation Instructions 11

Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional Installing New IO Libraries 1 Turn the Computer ON. As Windows XP Professional has started, the user is notified about new detected hardware via tool tip in the right corner of the task bar. The Found New Hardware Wizard will start some while later. At this moment, select Cancel. (See Figure 12) Figure 12 Found New Hardware Wizard 2 Using the Windows Explorer, locate and start Iolibs.exe in the \GPIB directory of your ChemStation CD-ROM. Follow the instructions in the installation Wizard. This will install the Standard Interface Control Library 12 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional (SICL) on your computer, update the registry and add a new Program Group called Agilent I/O Libraries. The InstallShield Wizard opens and starts the IO Libraries installation. Figure 13 Install Shield Wizard 3 When the title screen appears, click Next to go the License Agreement screen and then click Yes to accept the licenses terms and to display the Readme Information. Agilent IO Libraries L.02.xx or higher - Installation Instructions 13

Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional Figure 14 Installation screen IO Libraries 4 Click Next to display the Select Type of Installation screen. 14 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional 5 Choose installation option Full Installation, for an installation of both the SICL libraries and VISA components. The System will go to the next screen and display the current settings. Figure 15 Installation options 6 By default SICL is installed in C:\Program Files\Agilent\IO libraries. VISA is installed by default in C:\Program Files\VISA\winnt. Click Next if you accept the default setting, or go back to set the directory you want via Custom Installation option. By clicking Next the IO Libraries will be installed. Agilent IO Libraries L.02.xx or higher - Installation Instructions 15

Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional 7 The IO Libraries has been successful installed now. Finish the installation without viewing the Readme file and without running the IO Conifg. Leave the screen with Finish and reboot the system. 8 As Windows XP Professional starts after power cycling, a tool tip will notify about new hardware and the Found New Hardware Wizard will start again. Select Option 2 and click Next. (See Figure 16) Figure 16 Found New Hardware Wizard 16 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional 9 Select Option 2 and click Next (See Figure 17). Figure 17 Install Hardware Device Drivers Agilent IO Libraries L.02.xx or higher - Installation Instructions 17

Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional 10 Select 82350 PCI and click Next.(See Figure 18). The installation of the device driver will start. Figure 18 Select a Device Driver 18 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional 11 Select Finish. (See Figure 19). Figure 19 Finish Installation GPIB card 12 The user will get a notification by the taskbar that the hardware is installed and ready to use. Also the IO Config Utility will be placed now in the taskbar. 13 Start the IO Config Utility by clicking in the Icon and choose Run IO Config. 14 From the list of available interface types choose the appropriate one, i.e. 82350 PCI GPIB in case you have the Agilent 82350 board installed (see Figure 20) Agilent IO Libraries L.02.xx or higher - Installation Instructions 19

Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional Figure 20 IO Libraries Configuration 15 Select Configure. The configuration utility, now attempts to detect the selected GPIB interface in the PC in order to assign the correct resources to the card. 20 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Configuring the Agilent 82350 GPIB Interface Drivers under Windows XP Professional 16 Set the SICL Interface Name to hp82341, the Bus Address to 30 and the System Controller flag as shown in Figure 21. Please note that the appearance of the dialog slightly differs depending on the type of GPIB board installed. NOTE. You need to type in the SICL interface name hp82341 with lower case letters for both cards. Figure 21 Configuration screens for GPIB cards 17 Select OK. The configured GPIB board should now be listed under Configured Interfaces in the Interface Configuration Screen. Close the window by clicking OK. The installation is complete. Note that you must re-start to initialize the IO Libraries. Agilent IO Libraries L.02.xx or higher - Installation Instructions 21

Upgrading Existing IO Libraries Upgrading Existing IO Libraries Upgrading IO Libs under Windows 2000 / XP The upgrade of the IO Libraries is the same for Windows 2000 Professional and Windows XP Professional systems. 1 Using the Windows Explorer, locate and start Iolibs.exe in the \GPIB directory of your ChemStation CD-ROM. Follow the instructions in the installation Wizard. This will install the Standard Interface Control Library (SICL) on your computer, update the registry and add a new Program Group called Agilent I/O Libraries. The InstallShield Wizard opens and starts the IO Libraries installation. Figure 22 Install Shield Wizard 22 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Upgrading Existing IO Libraries 2 An upgrade screen appears that shows the current version installed and the new version that will be installed. (see Figure 23) Figure 23 Upgrade screen Agilent IO Libraries L.02.xx or higher - Installation Instructions 23

Upgrading Existing IO Libraries 3 When the upgrade screen appears, click Next to go the License Agreement screen and then click Yes to accept the licenses terms, click Next to display the Readme Information and click Next again to get to the current settings. 4 By clicking Next the system will install the SICL libraries and VISA components. Figure 24 SICL libraries and VISA components 5 Select Run IO Config to check configuration of the interface card (see Figure 24) 6 The installed interface card appears already in the Configured Interface List. Please verify VISA Name GBPI0 and SICL Name hp82341. Otherwise select the configured interface and enter via edit. (see Figure 25) 24 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Upgrading Existing IO Libraries Figure 25 IO Libraries Configuration 7 If necessary set the SICL Interface Name to hp82341, the Bus Address to 30 and the System Controller flag as shown in figure. Please note that the appearance of the dialog slightly differs depending on the type of GPIB board installed. NOTE. You need to type in the SICL interface name hp82341 with lower case letters for both cards. Agilent IO Libraries L.02.xx or higher - Installation Instructions 25

Upgrading Existing IO Libraries Figure 26 Configuration screens for GPIB cards 8 When installation is complete, leave the screen with OK. Note that you must re-start to initialize the IO Libraries. 26 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Working with your Agilent IO Libraries Working with your Agilent IO Libraries What has been changed by the Installation? Depending on the installation option you selected, SICL and/or VISA were installed and several program icons were created. In addition, an Agilent IO Libraries Control was created. During installation, the Agilent IO Libraries program group was created. Figure 27 Agilent IO Libraries program group Agilent IO Libraries L.02.xx or higher - Installation Instructions 27

Working with your Agilent IO Libraries Troubleshooting Missing files during installation During installation is might by possible that the system is looking for some IO installation files which are not copied during the installation process. In case of these the system will ask you to manual locate the files during the installation process. 1 The manual process might take place during the installation of the driver, after choosing next to start installation (see Figure 28) Figure 28 Driver Installation Screen 28 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Working with your Agilent IO Libraries 2 The wizard asks for the file agtgpibclass.dll as shown in Figure 29. Figure 29 Searching for file 3 Browse to C:\windows\system32\ and click OPEN. (See Figure 30) Figure 30 file Location Agilent IO Libraries L.02.xx or higher - Installation Instructions 29

Working with your Agilent IO Libraries 4 Select OK as shown in Figure 31 Figure 31 Choosing file 30 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Working with your Agilent IO Libraries 5 The wizard asks for the file agt82350.sys when an Agilent 82350 card is installed as shown in Figure 32. Figure 32 Searching for file agt82350.sys 6 Browse to C:\windows\system32\drivers\ and click OPEN. (SeeFigure 33) Figure 33 File location Agilent IO Libraries L.02.xx or higher - Installation Instructions 31

Working with your Agilent IO Libraries 7 Select OK as shown in Figure 34 Figure 34 select file 32 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Working with your Agilent IO Libraries 8 After the driver installation is completed press Finish, the configuration of the driver can be done using the IO Config Utility described in the installation procedures. Figure 35 Finishing installation Agilent IO Libraries L.02.xx or higher - Installation Instructions 33

Working with your Agilent IO Libraries Problems with Plug and Play option Operation systems using Plug and Play may show problems during the installation of the appropriate drivers for the GPIB (PCI) cards. In order to overcome plug and play related problems please follow the steps to install the card successfully. 1 If already installed, uninstall the Agilent IO Libraries from Control Panel, Add/Remove Programs. 2 Remove the GBIB Interfaces (if installed) listed under the Device Manager and shutdown the computer. For Windows 2000: Control Panel, double-click System, Hardware Tab, Device Manager, GPIB Interfaces For Windows XP: Control Panel, double-click System, Hardware Tab, Device Manager, GPIB Interfaces 3 Physically remove the GPIB card from the computers PCI Interface. 4 Restart the computer and log on to the system. Install the Agilent IO Libraries revision L.02.01. Do not configure the card this time and shutdown the computer. 5 Install the GPBI card again and turn on the computer - the new hardware found wizard will indicate that a PCI card is found. Select the second choice to search from a list of known devices and there select the option for Agilent Technologies, since the IO Libraries are already installed. 34 Agilent IO Libraries L.02.xx or higher - Installation Instructions

Working with your Agilent IO Libraries 6 If the new hardware wizard does not run, then check the device manager to verify that the GPIB interfaces is listed and installed correctly. installation procedures. Figure 36 Device Manager Windows 2000 7 To configure the GPIB card please follow the instructions stated in the first sections of this booklet. Continue by step 12 (Windows 2000)/step 13 (Windows XP). Start the IO Config Utility by clicking in the Icon and choose Run IO Config. Agilent IO Libraries L.02.xx or higher - Installation Instructions 35

*G2170-90121* *G2170-90121* G2170-90121 Part Number: G2170-90121 Edition 08 / 2004 Printed in Germany Agilent Technologies, Inc. 2004 Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn, Germany