Close-coupled cooling

Similar documents
InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

84 kw, Tier 3, Direct Expansion, 937 ft 2

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Schneider Electric Easy UPS 3S

200 kw, Tier 3, Chilled Water, 5250 ft 2

1008 kw, Tier 2, Chilled Water, ft 2

Schneider Electric Easy UPS 3S

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Business continuity made easy

APC APPLICATION NOTE #146

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

INNOVATE DESIGN APPLY.

9.6 MW, Traditional IT and OCP-compatible, Indirect Air Economizer, m 2

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

INNOVATE DESIGN APPLY.

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

5.2 MW, Pod-based build, Chilled Water, ft 2

Ecoflair Air Economizers

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Modular, scalable, high-efficiency power protection for data centers

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Rittal Cooling Solutions A. Tropp

Overcoming the Challenges of Server Virtualisation

Aquaflair. BREC/F and BCEC/F kw

Virtualization and consolidation

Uniflair Access Floor for data centers

Next Generation Cooling

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

APC by Schneider Electric Elite Data Centre Partner

Modular, scalable, high-efficiency power protection for data centers

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Precision Cooling. Precision Cooling Advantages

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Total Modular Data Centre Solutions

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Rack cooling solutions for high density racks management, from 10 to 75 kw

Liebert PDX from 15 to 120 kw

The synergy of SCADA with energy control

Close Coupled Cooling for Datacentres

One Stop Cooling Solution. Ben Tam Business Development Manager

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

Efficiency of Data Center cooling

IT Air Conditioning Units

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Liebert DCW CATALOGUE

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

DC Energy, Efficiency Challenges

Configurable power distribution

Power and Cooling for Ultra-High Density Racks and Blade Servers

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Liebert PDX from 15 to 120 kw

Reducing Data Center Cooling Costs through Airflow Containment

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

SmoothAir Modular Precision Cooling

Power & Cooling Considerations for Virtualized Environments

ACFD12-T ACFD12-B. Technical Data

MGE Galaxy 5000 for emergency lighting and power equipment

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Scalable, Secure. Jason Rylands

Liquid Cooling Package LCP Cooling Systems

MSYS 4480 AC Systems Winter 2015

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

HIGH DENSITY RACK COOLING CHOICES

Galaxy VX. From 500 kw to1500 kw N+1 Parallel solutions up to 4000 kw 480 V. schneider-electric.com

Precision Cooling Mission Critical Air Handling Units

Switch to Perfection

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Industry leading low energy evaporative fresh air cooling.

Data Center Energy Savings By the numbers

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Data Center Trends: How the Customer Drives Industry Advances and Design Development

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

Liquid Cooling Package LCP Cooling Systems

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

SmartMod Intelligent, Integrated Infrastructure for the Data Center

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Create a sustainable, high-performance university campus.

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Data Center Optimized Controls

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

APC APPLICATION NOTE #126

Thermal management. Thermal management

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Modbus Register Map: InRow ACRD60x / ACRC60x

HPC Solutions in High Density Data Centers

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

1.0 Executive Summary. 2.0 Available Features & Benefits

Transcription:

Close-coupled cooling Intelligently controlled high-performance InRow cooling for the IT environment APC TM by Schneider Electric close-coupled cooling products provide a modular, scalable, and predictable solution to meet the cooling needs of any IT environment. apc.com

apc.com

Table of contents InRow cooling Close-coupled architecture Active response controls InRow chilled water Chilled water distribution unit InRow direct expansion Data center infrastructure management Online resources Page 4 Page 6 Page 7 Page 8 Page 10 Page 12 Page 14 Page 16 apc.com

InRow cooling Up to 70 kw Close-coupled cooling for small to large data centers The InRow TM cooling product design closely couples the cooling with the IT heat load. An unpredictable data center environment is common among IT managers. In today s data centers, traditional cooling approaches involve complex air distribution systems that tend to be unpredictable and leave many customers guessing where the cold air goes. With the InRow cooling products, Schneider Electric has taken the guesswork out of data center cooling. Placing the unit in the row of racks moves the source of cooling closer to the heat load. This minimizes air mixing and provides a predictable cooling architecture. Close-coupled cooling for small to large data centers Scalability with Predictability at the rack and row level High density zones in larger data centers Small 200 kw Data center size Medium 500 kw Large 1 MW+ 0 5 10 12 15 20 25 >25 Density kw/rack Total cost of ownership: InRow units are ideally suited for small and medium data centers as well as high density zones in data centers of any size. Check out White Paper #130: Choosing Between Room, Row, and Rack-based Cooling for Data Centers www.apc.com/wp?wp=130 4 apc.com

Flexibility Modular and tailored solutions for any application Availability Continuous operation to safeguard the customer s business Energy saving Technological excellence for efficient performance apc.com 5

Close-coupled architecture Flexible, reliable, standardized solutions Modular unit design allows a pod/zone expansion as IT needs change and grow Greenfield/brownfield environments Raised/slab floor Room neutral Non-conventional IT spaces/office space Worldwide availability InRow cooling products are designed by combining cutting-edge technology with extensive tests for energy efficiency and continuous availability. Predictable solution for the unpredictable environment Energy savings, complete reliability, and total flexibility guarantee TCO reduction. A close-coupled cooling architecture moves the cooling unit from a traditional perimeter placement to a location that is in the row or above the IT racks. The InRow unit targets the heat that is generated by the IT equipment by pulling the hot air directly from the hot aisle where the heat is generated. The unit removes the heat and supplies cool air into the cold aisle/ environment, which is the source of cool air for the IT equipment. Initial deployment Cooling units Close coupling keeps the hot air in the hot aisle InRow cooling with EcoAisle containment maximizes efficiency and predictability Expansion Final deployment 25 kw per rack when combined with thermal containment system +80% of additional capacity* by capturing the heat at the source *29.4 C (85 F) vs. 22.2 C (72 F) return air temperature 6 apc.com

Active response controls Increase availability by actively responding to thermal changes Built into the microprocessor controller Provides visibility into the unit s operation, health, and capacity 40% energy savings when paired with active flow controller 100% predictable redundancy per pod/cluster* * Each cluster is designed for N+1 redundancy apc.com 7

InRow chilled water Up to 70 kw Standard features Water side economization Allows maximum capacity at elevated water temperatures Dual power inputs Offers redundancy and protection Top/bottom piping and power connection Flexibility of installation Field configurable Variable speed fans Reduce energy consumption during off-peak hours Intelligent control Network manageability, real-time capacity monitoring, predictive failure notification, and rack inlet temp control Air filter Removes airborne particles and protects cooling coil Casters and leveling feet Easily adjustable leveling from top down Integrated baying brackets 24 in. or 600 mm spacing options Bays with other APC rack and power products Field configurable two-way or three-way chilled water flow operation Remote temperature probe to control rack inlet temperature Factory-installed condensate pump (except models with optional dew point control) Dew point control pump 8 apc.com

Technical data Model 300 mm (12 in.) wide 600 mm (24 in.) wide Capacity Up to 40 kw Up to 60 kw Up to 70 kw Input voltage 100 240 V, 1 ph, 50/60 Hz 208 230 V, 1 ph, 50/60 Hz Fans Variable speed EC propeller fans (hot swappable) 200 V 240 V, 3 ph, 50/60 Hz 380 V 415 V, 3 ph, 50/60 Hz 460 V 480 V, 3 ph, 60 Hz Variable speed EC plug fans Condensate management Dual-float condensate pump Dew point control (optional) Dual-float condensate pump Options Cable water detector Electric reheat humidification cable water detector Controls 4.3 in. touch-screen display with active response controls Communications Network transport layer security protocols: SNMP, Telnet, HTTP, HTTPS, Modbus TCP/IP, FTP Serial Protocols: RS-232 Console, RS-485 Modbus RTU remote monitoring Dimensions Height 1991 mm (78.4 in.) 1991 mm (78.4 in.) Length 300 mm (11.8 in.) 600 mm (23.6 in.) Depth 1095 mm (43.1 in.) 1070 mm (42.1 in.) Options/accessories Flexible piping Active flow controller Height adapters Aquaflair TM chillers Rack air containment EcoAisle containment apc.com 9

Chilled water distribution unit Up to 12 InRow RC (ACRC301S) cooling units Standard features Top/bottom piping connection Flexibility of installation Field configurable Isolation and balancing valve Allows isolation and coolant flow adjustments for installation and service Casters and leveling feet Easily adjustable leveling from top down Insulated piping headers Prevents condensation in the unit Technical data Model Capacity Dimensions Height Length Depth ACFD12 Up to 10.1 lps (160 GPM) 1991 mm (78.4 in.) 1070 mm (42.1 in.) 750 mm (29.5 in.) Options/accessories Flexible piping 10 apc.com

Maximum efficiency, total availability Where no failure is allowed apc.com 11

InRow direct expansion Up to 42 kw Standard features Variable capacity control Allows for low load handling capabilities Top/bottom piping and power connection Flexibility of installation Field configurable Variable speed fans Reduce energy consumption during off-peak hours Intelligent control Network manageability, real-time capacity monitoring, predictive failure notification, and rack inlet temp control Air filter Removes airborne particles and protects cooling coil Casters and leveling feet Easily adjustable leveling from top down Integrated baying brackets 24 in. or 600 mm spacing options Bays with other Schneider Electric rack and power products Lead/lag functionality Remote temperature probe to control rack inlet temperature Factory-installed condensate pump 12 apc.com

Technical data Model 300 mm (12 in.) wide 600 mm (24 in.) wide Capacity Up to 10 kw Up to 42kW Input voltage Heat rejection Fans 208 230 V, 1 ph, 60 Hz 220 240 V, 1 ph, 50 Hz Air-cooled Fluid-cooled Self-contained Variable speed EC propeller fans (hot swappable) 200 V 240 V, 3 ph, 50/60 Hz 380 V 415 V, 3 ph, 50/60 Hz 460 V 480 V, 3 ph, 60 Hz Air-cooled Variable speed EC plug fans Condensate management Dual-float condensate pump Dual-float condensate pump Options Cable water detector Electric reheat humidification cable water detector Controls Four-line alphanumeric display with active response controls 4.3 in. touch-screen display with active response controls Communications Network transport layer security protocols: SNMP, Telnet, HTTP, HTTPS, Modbus TCP/IP, FTP Serial Protocols: RS-232 Console, RS-485 Modbus RTU remote monitoring Dimensions Height 1991 mm (78.4 in.) 1991 mm (78.4 in.) Length 300 mm (11.8 in.) 600 mm (23.6 in.) Depth 1095 mm (43.1 in.) 1070 mm (42.1 in.) Options/accessories Heat rejection Active flow controller Height adapters Data and power troughs Rack air containment EcoAisle containment apc.com 13

Data center infrastructure management Good design and quality construction alone do not ensure a highly available and efficient data center. Data centers require ongoing monitoring and management to ensure the facility lives up to its design intent. StruxureWare for Data Centers is a software management suite designed to collect and manage data about a data center s assets, resource use, and operational status throughout the life cycle of the facility. This information is then distributed, integrated, and applied in ways that help managers optimize the data center s performance and meet IT, business, and service-oriented goals. From IT assets to racks, rows, rooms, and buildings, StruxureWare for Data Centers delivers the right information to the right users at the right time. Control level Experts, on-site or remotely, can control process performance and ensure business continuity in real time while tracking energy consumption in a highly critical and secure environment. Operations level Functional managers can optimize operations, energy, and assets through smart analytical tools, often spanning multiple sites. Technological solutions are constantly evolving and improving our experience and expertise in cooling. 100% state-of-the-art technology Many years of experience, combined with innovative technology, has enabled our designers to make the technological and operational choices necessary to reach technical excellence in our products and make them ideal in cutting-edge applications. Enterprise level C-level executives can drive their sustainability strategy efficiently, choosing the best scenario that meets their business objective to conserve enterprisewide resources. StruxureWare for Data Centers allows for flexibility when requirements and implementation strategies change over time. StruxureWare software applications and suites simplify integration time, improve reliability, enhance visibility to energy information, and streamline operational efficiency. Visit www.apc.com/software to learn more about StruxureWare for Data Centers! 14 apc.com

apc.com 15

Online resources Product showcase videos Cooling capabilities For the data center and beyond visit http://tv.schneider-electric.com InRow pumped refrigerant cooling system Visit http://tv.schneider-electric.com Market solutions Visit http://tv.schneider-electric.com Schneider Electric interactive cooling application Visit www.apc.com/products/category.cfm?id=9# Additional resources White Paper #130: Choosing Between Room, Row, and Rack-based Cooling for Data Centers Visit www.apc.com/wp?an=130 White Paper #135: Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency Visit www.apc.com/wp?an=135 White Paper #153: Implementing Hot and Cold Air Containment in Existing Data Centers Visit www.apc.com/wp?an=153 InRow chilled water Visit www.apc.com/products/family/index.cfm?id=339 InRow pumped refrigerant Visit www.apc.com/products/family/index.cfm?id=415 InRow direct expansion Visit www.apc.com/products/family/index.cfm?id=379 To learn more about Schneider Electric cooling solutions visit www.schneider-electric.com Schneider Electric Head Office 35 rue Joseph Monier 92500 Rueil Malmaison Cedex- France Tel.: +33 (0)1 41 29 70 00 www.schneider-electric.com www.schneider-electric.com October 2016 2016 Schneider Electric. All Rights Reserved. Schneider Electric Life Is On is a trademark and the property of Schneider Electric SE, its subsidiaries, and affiliated companies. 998-1253170_GMA-US_A This document has been printed on recycled paper