Process Gas Chromatograph PGC1000

Similar documents
NGC 8206 Natural gas chromatograph

ABB MEASUREMENT & ANALYTICS DATA SHEET. NGC8206 Natural gas chromatograph

ABB MEASUREMENT & ANALYTICS DATA SHEET. NGC8207 Natural gas chromatograph

ABB. The NGC 8209, the C9+ natural gas chromatograph performs on-site natural gas analysis and heating value computation using an extended analysis.

NGC 8209 Natural gas chromatograph

ABB MEASUREMENT & ANALYTICS DATA SHEET. Portable NGC Natural gas chromatograph

PGC1000 Process gas chromatograph

Process Gas Chromatograph PGC5000 Series. PGC5000A Master Controller Designed for Reliability and Simplicity

FICHA TÉCNICA DE PRODUTO

Process Gas Chromatograph

ABB Analytical ABB Process Analytics. VistaII. Model 2000 Process Gas Chromatograph

Process Gas Chromatograph

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

Rosemount TM 700XA Process Gas Chromatograph

Advances in NeSSI TM communications

Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. VASTHI ENGINEERS

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

MOVING FROM PIPELINE TO PROCESS APPLICATIONS

subject to change without notice and should not be construed as a Notice: This publication is for information only.

MICRO GC FUSION Micro GC Fusion 3/17/2014 1

VPINSTRUMENTS.COM VPFLOWSCOPE M. Your next step in gas flow measurement

DTM Distributed Transmitter Monitor

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

µflo 6200 Series Overview 6200 Series Products µflo 6200 Series

Heat Value Gas Chromatograph ISO standard version

Level-Lance Model 5400A

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

XRC 6490, XRC 6790, and XRC 6890 XSeries Products Remote Controller

Family of Water Cut Analyzers

700XA Process Gas Chromatograph

PRODUCT CATALOG PRODUCT CATALOG.

IN-LINE. vpinstruments.com

Rosemount 370XA Natural Gas Chromatograph

Dräger Polytron 8200 Stationary gas detector (CatEx)

Process Gas Chromatograph Transmitter

NGC8106 Single Stream Sampler Startup Guide

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter

3420 Fieldbus Interface Module (FIM) Contents

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

TA Instruments Installation Requirements for Microcalorimeter Systems

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

HGC Data Manager. Model HDM303 OVERVIEW FEATURES. No. SS2-HDM (Rev.3)

SS3000e DUAL CHANNEL H2O GAS ANALYZER KEY FEATURES NEW FEATURES. FOR NATURAL GAS Product Code 10805

Technical Information Promonitor NRF560

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Danalyzer 700XA Gas Chromatograph

Model 700 On-line Gas Chromatograph NATURAL GAS MEASUREMENT - Power, Precision, Reliability

700XA Process Gas Chromatograph

MMT330 Series Moisture and Temperature Transmitters for Oil

Flow Measurement SITRANS F US Clamp-on

MPU 600 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Applications. Operating Specifications. Principle of Operation

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

JT400 Multivariable Transmitter

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

ASM Series. Advanced Signal Multi-scanner. Functional signal multi-scanner adding flexibility to your calibration needs

XFC 6411, XFC 6414, and XFC 6714 XSeries Products Linear Flow Computer

DMT345 and DMT346 Dewpoint Transmitters

red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection

Multiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

MPU 800 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation. Applications

Fast, accurate, easy to integrate and easy to maintain leak testing

TA Instruments Installation Requirements for Microcalorimeter Systems

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. In-situ low cost, low maintenance devices for continuous process and emissions monitoring.

Portable Ground Control Station

XFC 6410, XFC 6413, and XFC 6713 XSeries Products Differential Flow Computer

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

RHE28. Field and Wall Mount Multifunction Coriolis Flow Transmitter

Technical Data. General specifications. Rated operating distance s n 3 mm

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

XRC G Panel Mount XSeries G4 Products Remote Controller

Oil & Gas. Control Control. every move. Pressure Temperature Level Flow

NUFLO MC Series. Flow totalizers

Online data sheet. Flow-X FLOW COMPUTER

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Electric actuator for quarter-turn valves. For output torques to 17,700 lb. in.

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

SwirlMaster The new generation of swirl flowmeters

Soprane II Documentation

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

RHE26. Rack/Panel/DIN Rail Mount Multifunction Coriolis Flow Transmitter

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Ultrasonic Heat Flow Meters

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Fibre-optic Multichannel Process FT-NIR Analyzer for Gasoline and Gasoil Final Product Blend Optimization

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Digital Positioner 8049

Danalyzer Model 2350A. Gas Chromatograph Controller

SITRANS F flowmeters SITRANS F US

Zone Pressure Touch (ZPT) Sensor - Standard Range

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Micro Motion Model 7950 and Model 7951 Signal Converters

TPE 1464 Series Pressure Transducer

Transcription:

Data Sheet Process Gas Chromatograph PGC1000 Analyzer Products Field Mounted GC DESCRIPTION The PGC1000 is a field mounted GC using two analytical trains per analyzer that enable measurements of C1 thru C9+, inerts and H2S in various Hydrocarbon Processing Industry (HPI) streams. The PGC1000 is perfect for measuring light hydrocarbon gases in locations where minimal space is available and a simple, reliable, low cost measurement is required. This analyzer is an excellent choice for most Gas Processing Industry applications. Also it is an excellent choice for monitoring fuel gases such as natural gas, synthetic gas, methane and/or bio-gas required for the efficient operation of process equipment and plant wide systems in the HPI. Servicing the analyzer requires minimal effort to gain access to the modular analytical hardware which is easily removed for replacement. The PGC1000 innovations include: Compact footprint - 16 inches front to back, 28 pounds Conventional analytical components, not a GC on a chip Windows CE operating system Interactive graphical display actuated by magnet contact Economical to operate Simple, reliable, easy to service, low cost measurement! STANDARD FEATURES Modular design includes: Modular software application based plug in software modules Manifold module (internal tubing now replaced by manifold) Analysis section contains stream selection solenoids, pressure regulation, 32 bit digital detector electronics and a dual-train chromatograph in a single, replaceable module 32 bit digital, low-power controlling electronics, using Windows CE (internal to GC unit) Microsoft Windows 2000 or XP based remote user interface software (PGC1000 RUI) Lithium battery-backed RAM Two remote serial digital communications ports; one local port Comprehensive diagnostics and wizards available to users Two-level security for user access control Audit-quality historical data; date and time stamped Auto-start cycle automatically: Stabilizes oven temperature Confirms modules functions Sets valve operation times Locates natural gas components Sets carrier gas pressures Gates natural gas components Validates/calibrates Returns to pipeline streams Operational alarms available with each analysis cycle Detectors - constant temperature, glass encapsulated thermister beads for rugged service and long life (will not burn out on loss of carrier) Dual 10 port valves have no moving metal parts Low utility usage - low-power, low-carrier, no instrument air required On demand or scheduled automatic calibration and diagnostics

Standard Sample Conditioning System On board digital ¼ VGA display with multiple screen access USB (Host and Client) and Ethernet ports SD memory cards Feed-Through heater DESCRIPTION A process gas sample is extracted from a flowing pipeline, transported to the analyzer, processed for particle removal and phase integrity, injected onto the chromatographic columns where component separation and peak detection occurs. The PGC1000 analyzes each sample utilizing established chromatographic techniques. The portioned sample is then vented with the carrier gas and results are stored in memory and communicated to other devices as needed. All of these values, as well as composition, are available on various OPC and MODBUS communication protocols. For specific application information, refer to separate application sheets. INSTALLATION The PGC1000 is a weatherproof device designed for field installation near the sampling point. This means it is acceptable to mount outside - in a temperature range of 0 F to 131 F (-18 C to 55 C), onto a pipeline with 2'' to 12'' pipe sizes or with an optional pole mount configuration. A cold weather enclosure is available as an option if ambient conditions are below either the sampled gas dew point or the operational specifications of the unit. SAMPLE SYSTEM The integral stream selector for the PGC1000 allows sampling up to four (4) different gas streams. Up to two of these sample streams can be designated as the calibration/validation sample. A standard sample conditioning module is supplied to address gas streams that need additional filtering and speed loops to reduce sample transport lag times. SAMPLE PROBE A sample probe is recommended to obtain a representative sample of the flowing gas stream. Genie and Welker sample probes are available and are specifically designed to require no power and avoid sample probe regulator icing. Optional electrically heated and auto insertion probes are also available. OPERATOR INTERFACE Functional setup and operation of the PGC1000 is accomplished by using a graphical user s interface software package called PGC1000 RUI (supplied with each unit) operating on a laptop or workstation PC in a Microsoft Windows 2000 or XP environment. The Windows utilities, combined with software designed specifically for the PGC1000, provide a powerful tool for operations, diagnostics, and downstream data handling. The PC can be directly connected to the PGC1000 via an RS-232, USB, or Ethernet connection. The Ethernet connection allows seamless integration onto the VistaNET 2.0 Analyzer Network. The user is prompted through push-buttons, dropdown boxes, wizards, and dialog boxes for setup, operations, data collection and monitoring. In addition, the unit has a standard ¼ VGA interactive display screen allowing the user access to basic analysis data. The user can also accomplish most of the operator functions from the front panel display without the use of a laptop or workstation PC. The Run-Hold-Calibrate functions can be done via a magnet interface through the explosion proof glass in the display. MAINTENANCE The PGC1000 was designed from the ground up to be maintained by personnel with little or no prior knowledge of Process Gas Chromatography. Both hardware and software are designed to provide low maintenance through easily replaceable electro-mechanical modules such as: PGC Termination Panel PGC Analytical Module, an easily removable Chromatograph subassembly, containing; PGC Manifold, Stream Selector Solenoid Valves, GC valve assembly, Dual Electronic Carrier Pressure Regulator Valves, Chromatograph Pilot Valve, and the PGC Analytical Processor. Heated PGC Feed-Through Sample Conditioning Module (SCM) 2

PGC Controller, (32 bit Processor) PGC ¼ VGA Display Other Maintenance Support Features: Intuitive Local Operator Interface (PGC1000 RUI) running Microsoft Windows 2000 or XP Diagnostic software and wizards for maintenance Digitized detector output (chromatogram) to PGC1000 RUI Remote or local operation of PGC1000 RUI Quick Start guide, Start up manual and Start up video HISTORICAL DATA The PGC1000 is designed to retain historical data. This data can be used for audit trails, maintenance and troubleshooting to verify transmitter operation over time, and provide a limited data backup for communication link reliability. The user is allowed to configure the period of the data retained by the PGC1000 via the Operator Interface. The default 1 memory configuration provides the most recent 480 analysis cycles containing: Normalized components Un-normalized components Alarms Stream averages for the (default 1 ) 840 last hours, 35 last days and the most recent last month analyses. Operational Parameters for the (default 1 ) last 480 cycles (Diagnostics Report): Selected peak times Selected peak areas Carrier regulator pressure Oven temperature Ambient temperature Sample pressure Detector noise values Detector balance values Audit logs (default 1 ) Last 480 alarms Last 480 events Data retained by the PGC1000 can be collected via a remote communication link or by the laptop PC local operator interface PGC1000 RUI. SPECIFICATIONS Designed for Pipeline-Quality Gas Streams. Clean is defined as having no particles larger than 1 micron and no more than 1 milligram of solids per cubic meter of gas Dry is defined as no more than 7 psi of water per million cubic feet of gas Dry is also defined as having less than 0.1 ppm of liquid at the coldest ambient condition expected at the coldest point in the system The liquid can be water, oil, synthetic lubricant, glycol, condensed sample, or any other non-vapor contaminate Stable gas is defined as a vapor containing less than 0.1 ppm of liquid when the vapor is cooled to 10 o C below the coldest ambient temperature possible at any point in the system Carrier Gas: Hydrogen, Nitrogen, Helium (consumption rate typically <20 cc/minute during analysis cycle) Analysis Time: Determined by application. Repeatability: Defined by application. Typically +1% Environmental Temperature Storage: -22 F to +140 F (-30 C to 60 C) Normal Operation: 0 F to +131 F (-18 C to 56 C) With optional Cold Weather Enclosure: -40 F to +131 F (-40 C to 56 C) Supply Voltage: 10.5 to 16 volts DC. Optional: 21 to 28 VDC Power Consumption @ 0 F ( 18 C)) Nominal: 7 Watts @ 15 VDC; 650 ma Start up: 45 Watts @ 15 VDC; less than 3 A Four stream capability. Manual calibration required with 4 sample streams. Single auto calibration stream and 3 sample streams, or 2 auto calibration streams and 2 sample streams. Certifications: NEC & CEC Class I, Div. 1, Groups B, C, and D, T6 (Default 1 ) The default memory configuration will provide for the data storage above. User may reallocate the memory that is available. 3

CFR 47, Part 15 : - ATEX II 2G : Ex d, IIB+H 2 T6; Zone 1 - EMC - EMI/RFI: - EN 55022, EN 61000-6-1, EN 61000-4-2, 4-3, 4-4, 4-6, 4-8 - CISPR 22-2004 IECEx Exd IIB + H2 T6; Zone 1 Miscellaneous Type Approvals: Industry Canada NMI (Pending) BRML (Romania) Communications supported: Two serial digital ports, software selectable for RS232, RS485, or RS422 One USB Man-Machine Interface USB hub (host and client) and Ethernet Ports Protocols Supported: OPC MODBUS ASCII or RTU MODBUS / TCP Server MODBUS / TCP Client Dimensions: 6.75 dia. 16'' long 9.00'' tall (17.1 cm 40.6 cm 22.9 cm) Weight: Approximately 28 lb. (12.7 Kg) Shipping Weight: 47 lb. (21.3 Kg). Weatherproof Construction: NEMA/Type 4X/IP 56, aluminum alloy with white polyester powder coating. AVAILABLE ACCESSORIES 120/240 VAC to 12VDC GP and Exp power supplies Pole or pipeline mounting kits Cold weather enclosure (also available in pipe mount configuration) Cold weather thermal jacket (future) Probes Temperature compensating fixed Temperature compensating retractable Liquid rejection Electrically heated, retractable Regulators (carrier and calibration blend) SD memory card Export crating Tool kit Welker liquid shut-offs Various maintenance kits Customer Factory Acceptance Test (FAT) 4

Installation Dimensions BUASC2-1-0607 Specifications subject to change without notice. ABB Inc. Analytical Products 843 N. Jefferson Street Lewisburg, WV 24901 USA Visit: www.abb.com/analytical E-mail: AnalyzeIT@us.abb.com