ICC. Siemens FLN Master Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

Similar documents
ICC. Metasys N2 Master Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

ICC. Modbus/TCP Client Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

ICC. Modbus RTU Sniffer Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

ICC. Modbus RTU Slave Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

ICC. EtherNet/IP Client Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

ICC. Mitsubishi MELSEC Client Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

ICC. Generic Socket Client Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

ICC. BACnet MS/TP Server Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

ETH-1000 Version Info

D-100 FLOW DISPLAY Siemens P1-FLN Network Interface Installation Guide

Enron Modbus I/O Driver (Series 2) Programmable Serial Interface Card

ABB Modbus RTU Driver for JMobile

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

17 Configuring a BM85 In this chapter

ICC Configuration Studio Version Info

DCP - Interface. Dynavert L. Technical Description July 2010 (Draft) Dynavert

Open Processor with Modbus Master Driver Owner s Manual Rev. 1, 6/98

ICC. XLTR-1000 Multiprotocol RS-485 Gateway INDUSTRIAL CONTROL COMMUNICATIONS, INC. Instruction Manual

DAQ Electronics, Inc 262B Old New Brunswick Road, Piscataway, NJ

ICC. PROFINET IO Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

X-gateway Interface Addendum DeviceNet Scanner Interface

Rotork Pakscan Driver for DeltaV Programmable Serial Interface Card

COMMUNICATIONS INTERFACE

Siemens S7-200 Driver PTC Inc. All Rights Reserved.

Setting the DCM Switches

NI-XNET Python API Documentation

LMV2 / LMV3... Modbus. User Documentation. Building Technologies Division

PM130 Powermeters Reference Guide ASCII Communications Protocol

Metrologics, LLC. Modbus Client Application User s Manual

INTELLIS. Modbus Direct Network Monitor

Communication 7. What's in this Chapter? This chapter contains the following sections:

JetWeb JX6-INT1 Function Description

Connecting UniOP Using Generic Modbus RTU

1. System Topology Required Equipment and Components Hardware Equipment Software Equipment... 6

D8000 SERIES QUICK START GUIDE

2G Actuator Communications Protocol Document Rotary & Linear Actuators

CONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS

CO General Specifications GS48D62Z00-00E-N GENERAL. ProSafe-COM extended communication system

750/760 COMMUNICATIONS GUIDE. Digital Energy Multilin. Feeder Management Relay

Using ModbusTest. Introduction:

Modbus Protocol For FTS/FTM 3x&8x

Analog Devices Driver Kepware, Inc.

Golander Peristaltic Pump MODBUS Communication Instruction

MGL Avionics. N16 Aviation band Navigation Radio ICD V1

User Guide Laird Configuration and Test Utility Software. Version 1.0

CAS IKS Gateway (Modbus RTU/TCP and HTML) Manual

Linear-Encoder Multi-Sensor CANopen Profile

Version Action Author Date

PM130 Powermeters Reference Guide Modbus Communications Protocol

Modbus ASCII Serial Device Driver Help 2009 Kepware Technologies

TOP Server V5 to MicroLogix Using DNP3 Ethernet Driver

Sample F4T 32-bit Modbus RTU Packet

Robert Shaw Reeltape Model 185A Programmable Serial Interface Card Series 2

GW-USB-05. User's Guide. FW v1.07. IQRF USB Gateway MICRORISC s.r.o. User_Guide_GW-USB-05_ Page 1

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

DirectNET Host. Communications Programs. In This Chapter...

MVI46-MCM SLC Platform Modbus Interface Module USER MANUAL. February 5, 2004

Lufkin Modbus Serial Driver Help Kepware Technologies

Sample F4T 32-bit Modbus RTU Packet

FACTORY AUTOMATION. PROGRAMMING SOFTWARE VisoSetup

GPD 506/P5 Apogee - FLN Technical Manual

DNP3 Master Serial Driver PTC Inc. All Rights Reserved.

Modbus on SenseAir S8

KL4001, KL4002 and KL4004

SERIES PM130EH POWERMETERS COMMUNICATIONS REFERENCE GUIDE

BLH. DXp-40 Interface Manual Allen-Bradley Remote I/O WEIGH SYSTEM TECHNOLOGY. TM014 Rev D 6/1/11 Doc 35105

Configuring the DX99 HART Node for HART Field Devices

Preliminary. SLDU022 User s Manual. PGA300 Pressure and Temperature Sensor Signal Conditioner. Copyright 2016, Texas Instruments Incorporated

Doug Fleenor Design, Inc. RS-232 to DMX512 Interface, 2 Generation. March 8, 2010 (Software V1.2)

THERMOSALD ISX RS485 MODBUS (V5) 3E S.r.l. - Via del Maccabreccia 37/a LIPPO DI CALDERARA (BOLOGNA) THERMOREGULATOR for PULSE WELDING

BV4531U. I2C or Serial 6 Way Relay

ICS Regent. Communications Package for W INTERPRET. Guarded Peer-Link Communications (T3831) PD-6041

Virtual RS3 I/O Driver For Series 2 Simplex Programmable Serial Interface Card

Tejas V Master Protocol

CLVM Driver CLV Command Language Module. Table of Contents

Modbus on S8. Modbus is a simple, open protocol for both PLC and sensors. Details on Modbus can be found on

EM23-DIN COMMUNICATION PROTOCOL. Version 0 Revision 0

Modbus on S8. Modbus is a simple, open protocol for both PLC and sensors. Details on Modbus can be found on

MN101EF69D. 8-bit Single-chip Communication LSI. Overview

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08

Profibus Gateway 3E V Technical Bulletin

Configuring Cisco IOS IP SLAs DNS Operations

PACSystems* RX3i IC695CMM002 and IC695CMM004

Application Note. Introduction AN2471/D 3/2003. PC Master Software Communication Protocol Specification

PACSystems* RX3i IC695CMM002 and IC695CMM004

Modbus Serial Driver PTC Inc. All Rights Reserved.

IntelliCAP PLUS Supplement for Landis & Gyr Telegyr 8979 Protocol

ASCII Printer Driver Programmable Serial Interface Card Series 2

Lufkin Modbus Driver PTC Inc. All Rights Reserved.

X-gateway Interface Addendum DeviceNet Scanner

Square D Sy/Max Driver Programmable Serial Interface Card

Experion LX Safety Manager Integration Guide

Softstarters. Type PSTX Fieldbus communication, Fieldbus Plug Modbus RTU. 1SFC132092M0201 June SFC132092M0201 1

Section 31. DMA Controller

Contents. Additional Instructions P-3X CANopen

Linear-Encoders CANopen Profile

SIMATIC S7 MPI Direct Driver

101M ProLinx Gateway IEC Master

IEC Master Driver PTC Inc. All Rights Reserved.

Please refer to application note AN00129 for further details on HCP2 configuration in ABB motion control products.

Transcription:

INDUSTRIAL CONTROL COMMUNICATIONS, INC. Siemens FLN Master Driver Manual January 5, 2018 2018 Industrial Control Communications, Inc.

TABLE OF CONTENTS 1 Siemens FLN Master... 2 1.1 Overview... 2 1.2 Master Settings... 2 1.3 Service Object Settings... 3 1.3.1 LAI Service Object Settings... 3 1.3.2 LAO Service Object Settings... 4 1.3.3 LDI Service Object Settings... 5 1.3.4 LDO Service Object Settings... 6 1.4 Override Release Trigger (excludes XLTR-1000)... 6 1.5 Diagnostics Object... 7 1

1 Siemens FLN Master 1.1 Overview This driver supports the Siemens FLN protocol as a network master. Some notes of interest are: Service objects can access LAI (Logical Analog Input), LAO (Logical Analog Output), LDI (Logical Digital Input), and LDO (Logical Digital Output) points. Supported FLN commands are indicated in Table 1. Table 1: Supported Siemens FLN Commands Command Code Command 06H Read A Point 07H Write A Point 75H Memorize A Point 0AH Get Point Information 0FH Release A Point* * Excludes XLTR-1000 The Get Point Information (0AH) command is implicitly used by the driver to get the current point information of each point before executing a read or write command. LAI and LAO slope and intercept is applied automatically when reading and writing points. Both English and Metric units are supported when accessing LAI and LAO points. 1.2 Master Settings Baud Rate Selects the baud rate of the network. Parity Fixed at No Parity (1 Stop Bit). Timeout Sets the time in milliseconds that the driver will wait for a response from a device after sending a request. Scan Rate This is the time in milliseconds the driver will wait between sending requests. This is a useful feature for certain devices or infrastructure components (such as radio modems) that may not be capable of sustaining the maximum packet rates that the driver is capable of producing. The start time for this delay is taken with respect to the moment at which the driver is capable of sending the next packet (due to either reception or timeout of the previous request). If no additional time is required, setting this field to 0 instructs the driver to send its next request packet as soon as possible. 2

1.3 Service Object Settings A variety of different service object types are available. Each type targets a different FLN point type. For each service object, the driver will continually read the values of the defined FLN point within the service object from the designated device, storing the values in the database (if the read function is enabled). When data in the database changes where the FLN points are mapped, a write request is generated to the designated device notifying it of the changed object values (if the write function is available and enabled). 1.3.1 LAI Service Object Settings Description This 32-character (max) field is strictly for user reference: it is not used at any time by the driver. Destination Address Indicates the destination address (0 99) of the remote slave device on the network that will be accessed by this service object. A destination address of 99 will receive a response from a device at any address. If the destination address is set to 99, ensure that there is only one slave connected. Start Point Number Defines the starting point number (1 99) for a range of FLN points for this service object. Number of Points Defines the number of FLN points (1...99) to be targeted by this service object. Database Address Defines the database address where the first FLN point value of this service object will be mapped. The configuration studio will not allow entry of a starting database address that will cause the service object to run past the end of the database. The highest valid database address, therefore, will depend on the targeted data type, as well as the number of items to be accessed. Data Type Specifies how the value will be stored in the database for each FLN point in this service object. This defines how many bytes will be allocated, whether the value should be treated as signed or unsigned, and whether the value should be interpreted as an integer or a floating point number. Select the desired data type from this dropdown menu. Multiplier The amount that associated network values are scaled by prior to being stored into the database or after being retrieved from the database. Upon retrieval from the database, raw data is multiplied by the multiplier to produce a network value (to be sent to the device). Similarly, network values (read from the device) are divided by the multiplier before being stored into the database. 3

Unit System Select the desired unit system to use for applying the FLN points slope and intercept. Read Function Fixed at Read A Point (06H). 1.3.2 LAO Service Object Settings Description This 32-character (max) field is strictly for user reference: it is not used at any time by the driver. Destination Address Indicates the destination address (0 99) of the remote slave device on the network that will be accessed by this service object. A destination address of 99 will receive a response from a device at any address. If the destination address is set to 99, ensure that there is only one slave connected. Start Point Number Defines the starting point number (1 99) for a range of FLN points for this service object. Number of Points Defines the number of FLN points (1...99) to be targeted by this service object. Database Address Defines the database address where the first FLN point value of this service object will be mapped. The configuration studio will not allow entry of a starting database address that will cause the service object to run past the end of the database. The highest valid database address, therefore, will depend on the targeted data type, as well as the number of items to be accessed. Data Type Specifies how the value will be stored in the database for each FLN point in this service object. This defines how many bytes will be allocated, whether the value should be treated as signed or unsigned, and whether the value should be interpreted as an integer or a floating point number. Select the desired data type from this dropdown menu. Multiplier The amount that associated network values are scaled by prior to being stored into the database or after being retrieved from the database. Upon retrieval from the database, raw data is multiplied by the multiplier to produce a network value (to be sent to the device). Similarly, network values (read from the device) are divided by the multiplier before being stored into the database. Unit System Select the desired unit system to use for applying the FLN point s slope and intercept. 4

Read Function Select whether or not to allow the service object to issue read requests. When enabled, the service object will continuously read from the slave unless a pending write exists. Write Function Select whether or not to allow the service object to issue write requests, and the command to use when enabled. When values encompassed by this service object change in the internal database and writes are enabled, these changes will be written down to the targeted slave. Note that not all points support the Write A Point (07H) command. Points such as set points and setup parameters that typically do not change once they ve been established may reject this command with a Security Error, which can be seen when using a Diagnostics Object. For these points, the Memorize A Point (75H) command must be used. Because the Memorize A Point (75H) command writes to both RAM and EEPROM on the slave device, while the Write A Point (07H) command writes only to RAM, it is recommended to only use the Memorize A Point (75H) command when absolutely necessary. 1.3.3 LDI Service Object Settings Description This 32-character (max) field is strictly for user reference: it is not used at any time by the driver. Destination Address Indicates the destination address (0 99) of the remote slave device on the network that will be accessed by this service object. A destination address of 99 will receive a response from a device at any address. If the destination address is set to 99, ensure that there is only one slave connected. Start Point Number Defines the starting point number (1 99) for a range of FLN points for this service object. Number of Points Defines the number of FLN points (1...99) to be targeted by this service object. Database Address Defines the database address where the first FLN point value of this service object will be mapped. The configuration studio will not allow entry of a starting database address that will cause the service object to run past the end of the database. The highest valid database address, therefore, will depend on the targeted data type, as well as the number of items to be accessed. Data Type Fixed at 1 Bit. Read Function Fixed at Read A Point (06H). 5

1.3.4 LDO Service Object Settings Description This 32-character (max) field is strictly for user reference: it is not used at any time by the driver. Destination Address Indicates the destination address (0 99) of the remote slave device on the network that will be accessed by this service object. A destination address of 99 will receive a response from a device at any address. If the destination address is set to 99, ensure that there is only one slave connected. Start Point Number Defines the starting point number (1 99) for a range of FLN points for this service object. Number of Points Defines the number of FLN points (1...99) to be targeted by this service object. Database Address Defines the database address where the first FLN point value of this service object will be mapped. The configuration studio will not allow entry of a starting database address that will cause the service object to run past the end of the database. The highest valid database address, therefore, will depend on the targeted data type, as well as the number of items to be accessed. Data Type Fixed at 1 Bit. Read Function Select whether or not to allow the service object to issue read requests. When enabled, the service object will continuously read from the slave unless a pending write exists. Write Function Select whether or not to allow the service object to issue write requests, and the command to use when enabled. When values encompassed by this service object change in the internal database and writes are enabled, these changes will be written down to the targeted slave. Note that not all points support the Write A Point (07H) command. Points such as set points and setup parameters that typically do not change once they ve been established may reject this command with a Security Error, which can be seen when using a Diagnostics Object. For these points, the Memorize A Point (75H) command must be used. Because the Memorize A Point (75H) command writes to both RAM and EEPROM on the slave device, while the Write A Point (07H) command writes only to RAM, it is recommended to only use the Memorize A Point (75H) command when absolutely necessary. 1.4 Override Release Trigger (excludes XLTR-1000) Each commandable service object, i.e. Output service objects, can optionally include an override release trigger to release a previously written override value. The trigger is assigned to 6

a byte in the database. When a write is detected at this database address, the trigger value is reset to 0, and a release request is sent to all points defined in the service object. Release Trigger Database Address Specifies the database address to use to trigger the release request. 1.5 Diagnostics Object Each service object can optionally include a diagnostics object for debugging and diagnostics. Diagnostics Database Address Enter the database address at which to store the diagnostics information. 7

INDUSTRIAL CONTROL COMMUNICATIONS, INC. 1600 Aspen Commons, Suite 210 Middleton, WI USA 53562-4720 Tel: [608] 831-1255 Fax: [608] 831-2045 http://www.iccdesigns.com Printed in U.S.A