Rosemount VeriCase User Guide

Similar documents
Emerson Plantweb Insight. Quick Start Guide , Rev DA April 2018

Rosemount 2051G Pressure Transmitter

Rosemount 5708 Series 3D Solids Scanner Integration with DeltaV

Rosemount 928 Wireless Gas Monitor

Rosemount Functional Safety Manual. Manual Supplement , Rev AG March 2015

Rosemount 2410 Tank Hub

Rosemount 3051HT Hygienic Pressure Transmitter

Gain better understanding and insight into your plant data

Quick Start Guide , Rev DA June Rosemount 708 Wireless Acoustic Transmitter

Emerson Wireless THUM Adapter

Rosemount 928 Wireless Gas Monitor

Rosemount 3051P Pressure Transmitter

Rosemount 370XA Natural Gas Chromatograph

Rosemount 2051 Pressure Transmitter and Rosemount 2051CF DP Flowmeters

Quick Start Guide , Rev EB June Rosemount 248 Wireless Temperature Transmitter

ROC800-Series Thermocouple Module

Connecting an Emerson Wireless Gateway to the ABB Totalflow XRC 6490

Rosemount 0085 Pipe Clamp Sensor

ControlWave Micro HART / BTI Interface Module

M-series Intrinsically Safe I/O

V-Cone Metering Program User Manual (for ROC800-Series)

Emerson Wireless 1410D Gateway with 781 Field Link

Rosemount 2160 Wireless Level Switch

ControlWave PAC Resistance Temperature Detector Module and Thermocouple Module

ControlWave Micro Resistance Temperature Detector Module and Thermocouple Module

Rosemount 3493 LOGView

ControlWave PAC Analog Input / Output Modules

Loading Configuration from TEC2000 to TEC2 using DCMLink. Configuration Instructions TEC2-LOAD-1001 Rev. 1 September 2015

TEC2 LDM Programming Instructions

Quick Start Guide , Rev DA June Rosemount 248 Wireless Temperature Transmitter

3420 Fieldbus Interface Module (FIM) Contents

DeltaV Version 14 Safety Instrumented Systems Enhancements

ControlWave Micro Digital Input / Output Modules

ROCLINK 800 Configuration Software

ControlWave PAC Redundant Systems

Rosemount 6888 In-Situ Oxygen Transmitter

Oldham OLCT 200 Revision 1

ControlWave PAC Digital Input / Output Modules

DeltaV Bulk Power Supplies

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

DeltaV Bulk Power Supplies

Guided Wave Radar Level and Interface Transmitter

FBxConnect Configuration Software

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

BLISS ANAND. BA-Series Magnetostrictive Level Transmitter

S-Series DeltaV Controller Interface for PROVOX I/O

AMS ValveLink Software Quick-Start Guide

M-series MQ Controller

Smart Wireless THUM Adapter

OpenEnterprise Licensing User Manual

Smart Wireless THUM Adapter

Rosemount 2110 Compact Vibrating Fork Liquid Level Switch

LCD Meter for Model 3051 Pressure Transmitters English Rev. AA

Rosemount 3493 LOGView

Springfield Product Portfolio

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

M-series MX Controller

Rosemount 6888 In-Situ Oxygen Transmitter

M-series DeltaV Controller Interface for PROVOX I/O

S-series Sequence of Events Card

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

DeltaV Electronic Marshalling for Migrations

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

S-series Mass Connection Solutions

HART Communicator. Emerson Process Management Catalog

DeltaV SD Plus Controller

Roxar SandLog High Accuracy Sand/Erosion Monitoring

8130 Remote Terminal Unit

S-series Sequence of Events Card

Rosemount 1595 Conditioning Orifice Plate

Rosemount 708 Wireless Acoustic Transmitter

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

S-series Electronic Marshalling for Migrations

DeltaV M-series I/O Subsystem Horizontal Carriers

Roxar CorrLog High Accuracy Corrosion Monitoring

ScannerCal Accuracy Verification System for the FlowScanner

PD 601 DPI with RS-232 P-NET Interface PD Series 600

375 Field Communicator

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

FloBoss 107 IEC Interface

S-series Virtual I/O Module 2

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Agilent U8000 Series Single Output DC Power Supplies. Data Sheet

S-series Foundation Fieldbus I/O

CTO CSLS CHARM Cabinets

DS800 Development Suite Quick Start Guide for the FloBoss 107

Altair RU. Owner s Manual. Document name: AtrRU-EN Document version: 0.3 Release date: 25/03/2009

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

Quick Start Guide MC-III TM Flow Analyzer

FloBoss 107 Firmware. Operating System. Remote Automation Solutions. D301235X012 October 2013

PD 667 DPI with RS485 Interface Profibus DP-V0 Essential Features Master PD Series 600

PD 600 DPI with RS-485 P-NET Interface PD Series 600

S-series Horizontal Carriers

914L. Capacitive Level Transmitter. Features. 1 Datasheet 914L Capacitive level transmitter for liquids.

Certified Technical Training for Emerson Flow Instruments. Helping you to maximize your Flow instrument investment

SMART WIRELESS SOLUTIONS FROM EMERSON

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

Rosemount TM 700XA Process Gas Chromatograph

HART Applications SEC-5000 Gas Detector

M-series Traditional I/O

Transcription:

Quick Start Guide 00825-0500-4530, Rev AC Rosemount VeriCase User Guide Rosemount 3308 and 5300 Series Level Transmitters with HART and Modbus

Quick Start Guide Rosemount VeriCase 1.0 Rosemount VeriCase overview The Rosemount VeriCase is a mobile verification tool for the Rosemount 3308 and 5300 Level Transmitter with HART and Modbus communications. Rosemount VeriCase Accuracy: Within ±1mm The picture below identifies the parts inside the case that the user should be familiar with before performing verification. Note The Rosemount VeriCase does not have any hazardous approvals certifications and should only be used outside of such classified areas. Figure 1. Rosemount VeriCase A G F E C B D A.Transmitter mount E. Power input B. Terminal connections F. Ground connection C. Cable switch G. USB cable connection D. Temperature display Contents Rosemount VeriCase overview................ 2 Check Rosemount VeriCase and verification sheet 3 Performing a verification on a Rosemount 5300 transmitter................................. 4 Performing a verification on a Rosemount 3308 transmitter.............................. 6 Generating a report....................... 8 Appendix................................ 9 2

Quick Start Guide 2.0 Check Rosemount VeriCase and verification sheet 2.1 Check contents Open the Rosemount VeriCase and check that it contains the following items; USB stick containing - User Instructions - Microsoft Excel workbook - Calibration certificate - HART modem drivers - Rosemount Radar Master (for Rosemount 5300 Level Transmitter) - Rosemount Configuration Tool (for Rosemount 3308 Wireless Level Transmitter) Printed calibration parameters Printed certificate 110/220V Power Supply 12 VDC Power Cable USB A-B cable Two terminal connection cables with banana plugs and grippers 2.2 Check verification sheet Open the Excel workbook found on the USB memory stick and check that the following details in the workbook correspond to the printed certificate found inside the Rosemount Vericase; Serial number and calibration date Cable lengths Values for temperature correction table 2.3 Power-up the Rosemount VeriCase The Rosemount VeriCase can be powered by either a 110V/220V power supply or a 12VDC power adapter supplied with the Rosemount VeriCase. In order to power-up the Rosemount VeriCase and connect to a transmitter head, follow the steps below; Connect the power cable Screw the transmitter firmly onto the mount on the faceplate Insert the terminal connectors in the '+' and ' ' terminals on the faceplate and attach the other ends to the terminals of the transmitter Connect the USB A-B cable between your computer and the Rosemount VeriCase. In order to start the verification procedure the switch should be turned from position '0' to position '1'. 3

Quick Start Guide 3.0 Performing a verification on a Rosemount 5300 transmitter 3.1 Before you start Open Rosemount Radar Master and record the serial number and firmware revision of the device to be tested in the verification data tab of the workbook. This information can be found in the device properties window in the 'device' menu in Rosemount Radar Master. 3.2 Verification procedure Note Inches or millimeters should be selected for measurement units (there is a possible inaccuracy of 1.25mm (0,05-in.) when inches are used for the display). 4 Configure device for verification 1. Save a backup file of the current device (this will need to be reloaded once the verification is complete) by selecting Device -> Save Config to File 2. In the Tank window under the Setup menu, configure the following parameters for the transmitter that will be tested: - Probe type: User Defined - Probe length: longest cable length +50cm (20-in) - Probe Impedance: 100 Ω - Reference Pulse Amplitude: 3000mV Make sure that the below parameters are set with the following values - Propagation Factor: 1,000 - Tank Connection Length: 0 - Remote housing: None - Probe angle: 0 - Vapor DC: 1 - Measurement mode: Liquid product level, solid product level or product level and interface level

Quick Start Guide Save these configuration changes and restart the device. 3.3 Verification test 1. Set the Cable Switch to position 1. Wait for the values to stabilize before taking a reading from the Device Display window in Rosemount Radar Master. 2. Record the distance value, internal temperature of transmitter and Rosemount VeriCase temperature. 3. Repeat the procedure in 2 for all six cable lengths in the Rosemount VeriCase. 4. Once the verification is complete, restore the original configuration by uploading the backup file to the transmitter. Select Device -> Upload Config from File and reload the file saved (see Configure device for verification ). 5. After the backup has been restored, disconnect power and communication to the transmitter. 5

Quick Start Guide 4.0 Performing a verification on a Rosemount 3308 transmitter 4.1 Before you start Record the serial number of the device from the nameplate located on top of the transmitter. Open Radar Configuration Tools and record the software revision of the device to be tested in the verification data tab of the workbook. This information can be found in the setup window under the info tab. 4.2 Verification procedure Note Inches or millimeters should be selected for measurement units (there is a possible inaccuracy of 1.25mm (0,05-in.) when inches are used for the display). Configure device for verification 1. Save a memory map from the current device (this will need to be reloaded once the verification is complete) by selecting Memory Map from the left-hand menu. Select Receive. When the values have finished loading select File and Save Memory. Note When reading a measurement value remember that the repeatability of a Rosemount 3308 is ± 2mm (0,08-in.) 6 2. In the Setup window under the Setup menu, configure the following parameters for the transmitter that will be tested: Probe type: User Defined

Quick Start Guide Probe length: longest cable length +50cm (20-in) Probe Impedance: 100 Ω Reference Pulse Amplitude: 30mV Make sure that the below parameters are set with the following values Propagation Factor: 1,000 Tank Connection Length: 0 Probe angle: 0 Vapor DC: 1 Measurement mode: Liquid product level or product level and interface level - Save these configuration changes and restart the device. 4.3 Verification test 1. Set the Cable Switch to position 1. Open Monitor in the left-hand menu. Select Product Distance and Electronics Temperature and press play. Wait for the values to stabilize before taking a reading from the Device Display window in Rosemount Radar Master. 2. Record the Product Distance value, Electronics Temperature and Rosemount VeriCase temperature. 3. Repeat the procedure in 2 for all six cable lengths in the Rosemount VeriCase. 4. Once the verification is complete, restore the original configuration by uploading the memory map to the transmitter. Select File from the top menu and Open Memory Map. When the values have loaded select Send to reload the configuration file saved (see Configure device for verification ). 7

Quick Start Guide 5. After the configuration has been restored, disconnect communication to the transmitter. 5.0 Generating a report Once testing is complete, a report can be generated from the Excel workbook. It is possible to generate a verification report and/or a Q4 certificate by selecting the corresponding generate report buttons located at the bottom of the verification data tab and the Q4 data tab respectively. In order to generate a Q4 certificate the analog output of the transmitter under verification should be tested at 4mA, 12mA and 20mA and the results saved in the Q4 data tab before generating the certificate. 8

Quick Start Guide 6.0 Appendix 6.1 FAQs Q: Can verification of a FOUNDATION Fieldbus transmitter be performed using the Rosemount VeriCase? A: Yes, but an external FOUNDATION Fieldbus modem (and power supply if Explosion proof) will be required as a FOUNDATION Fieldbus modem is not built in to the Rosemount VeriCase. Q: What do I do if a device fails? A: Check that the device is correctly configured and repeat the test. If the results are the same, log a support request in the same way as you would with other level instrumentation, providing all details of the testing, including results and backup files. Q: How do I know if a device has passed the test? A: Refer to the Rosemount 5300 PDS for accuracy specifications. A device has passed if the final result is inside the combined accuracy for the Rosemount 5300 and the Rosemount VeriCase as shown in the Excel workbook. Q: What does the offset value in the results mean? Do I need to adjust anything in the guided wave radar settings? A: This is the offset generated from using the Rosemount VeriCase rather than a probe. This is compensated for automatically and there is no need for manual adjustments. Q: Why is the transmitter rebooted every time I switch cable length? A: This is so the measurement can be reset to lock on to a new value without echo logic or filtering affecting the measurement. Q: How often should Rosemount VeriCase be calibrated? A: Once a year or if calibration seals have been broken. Q: The calibration of the Rosemount VeriCase has expired. What do I do? A: Every world area has an assigned administrator to coordinate recalibrations. Contact your administrator for further instructions. 9

*00825-0500-4530* Quick Start Guide 00825-0500-4530, Rev AC Global Headquarters 6021 Innovation Blvd. Shakopee, MN 55379, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@Emerson.com North America Regional Office 8200 Market Blvd. Chanhassen, MN 55317, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RMT-NA.RCCRFQ@Emerson.com Latin America Regional Office 1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA +1 954 846 5030 +1 954 846 5121 RFQ.RMD-RCC@Emerson.com Europe Regional Office Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland +41 (0) 41 768 6111 +41 (0) 41 768 6300 RFQ.RMD-RCC@Emerson.com Asia Pacific Regional Office 1 Pandan Crescent Singapore 128461 +65 6777 8211 +65 6777 0947 Enquiries@AP.Emerson.com Middle East and Africa Regional Office Emerson FZE P.O. Box 17033 Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates +971 4 8118100 +971 4 8865465 RFQ.RMTMEA@Emerson.com Linkedin.com/company/Emerson-Automation-Solutions Twitter.com/Rosemount_News Facebook.com/Rosemount Youtube.com/user/RosemountMeasurement Google.com/+RosemountMeasurement Standard Terms and Conditions of Sale can be found on the Terms and Conditions of Sale page. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and Rosemount logotype are trademarks of Emerson. HART is a registered trademark of the FieldComm Group. Modbus is a registered trademark of Gould Inc. FOUNDATION Fieldbus is a trademark of the FieldComm Group. Excel and Microsoft are a registered trademarks of Microsoft Corporation in the United States and other countries. All other marks are the property of their respective owners. 2017 Emerson. All rights reserved.