CINT W Single Output Industrial Series

Similar documents
CINT W Triple Output Industrial Series

ME to 30W Single Output External Power Medical Series. Features

Safety Standards. Model Number: Unit Weight:

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

LPS. ME20 20W Single Output External Power Medical Series. Features

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Safety Standards. Model Number:

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Safety Standards. Model Number:

C1U-W Tx Series

Safety Standards. Model Number:

275 Watt Medical Ultra low profile

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

60 Watt Medical (MWLT)

Safety Standards. Model Number:

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

Safety Standards. Model Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

CPCI - 6U - AC - 600W

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Safety Standards. Model Number:

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Universal Power Supplies

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09

Enclosed Power Supplies

12-15VDC (12V±5%) 24-28VDC (24V±5%)

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

ORDERING INFORMATION SEE PAGE 6

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Constant Voltage Mode

C1U-W Tx Series AC/DC Front End Power Supply

CPCI - 6U - DC - 350W

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

HEC-100RTN-48QSCA Rev A1.0

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

IEC/EN/UL60950 & CE certified, EN55032 Class B

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Safety Standards. Model Number:

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

D1U3CS-W HxxC Series

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Safety Standards. Model Number:

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

The ATF YE meets UL/CSA and all international safety requirements. CE mark is pending. Min Typ Max

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

Output Voltage* (nom.)(adjustable)

SPECIFICATIONS: PSAK650

CLP0224 SERIES 200 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.40

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

PMT. Safety Standards. Model Number:

PMT. Safety Standards. Model Number:

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Universal input VAC <150mW No load power consumption

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

AC-DC Power Supplies. The PerFormanCe Power PFC250 meets international safety requirements and is CE Marked to the Low Voltage Directive.

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Safety Standards. Model Number

Max. Output Power. Typical Efficiency (3) 0 ~ 25.0 A 300 W 91.5% 0.96 EBV-350S012SV 0 ~ 14.6 A 350 W 93.5% 0.96 EBV-350S024SV

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-24V100W2AA Vac 24Vdc 4.50A

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

Top Microsystems Proprietary Specification P/N: P6301H N1F SK SPECIFICATION P/N: P6301H N1F

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

500Watts Medical Single Output

Transcription:

Features 2 x 4 x 1.3 Package For 1U Applications 175W w/air, 12W convection cooled Universal Input 9264 VAC Average Efficiency meets Level V Requirements Approved to CSA/EN/IEC/UL695, 2nd Edition 12V fan output Efficiency 9% typical at Full Load 3 Year Warranty RoHS Compliant Description A highly dense 175Watts AC to DC power supply designed for industrial and ITE applications. With convection rating of 12 Watts, CINT1175 family leads the market in power density and low leakage makes it a perfect solution for lighting applications. With input & output monitoring alarms plus isolated 12V/.4A fan, it is one the most feature rich supplies and can easily fit in 1U chassis. All 5 models are CE marked to low voltage directive and approved to ITE standards of EN695, 2nd edition. Model Selection Model Output Current Ripple & Total OVP*** Number Volts w/2lfm air Convection Fan Output Noise** Regulation Threshold*** CINT1175A126K1 12V 14.6A 1.A 12Vdc/4.A.5%RMS, 1.2% pkpk ±3% 14. ± 1.1V CINT1175A156K1 15V 11.7A 8.A 12Vdc/4.A CINT1175A246K1 24V 7.3A 5.A 12Vdc/4.A CINT1175A486K1 48V 3.6A 2.5A 12Vdc/4.A.5%RMS, 1.% pkpk.5%rms, 1.2% pkpk.5%rms, 1.% pkpk ±3% 18.5 ± 1.5V ±3% 28. ± 2.5V ±3% 55. ± 4.V.5%RMS, CINT1175A566K1 56V 3.1A 2.1A 12Vdc/4.A ±3% 59. ± 1.V 1.% pkpk Notes: * Total convection power is 12 Watts. ** Measured with noise probe directly across output terminals, and load terminated with.1µf ceramic and 1µF low ESR capacitors. *** Output adjustment on 56V model will not exceed 56.2 volts. General Specifications AC Input 124Vac, ±1%, 4763Hz, 1 12 37Vdc Turn On Time Less than 2 sec. @115Vac (inversely proportional to input voltage and thermistor temperature) Input Current 115Vac: 2A, 23Vac: 1A Holdup Time 16mS, typical Inrush Current 264Vac, cold start: will not exceed 5A Signals AC Power Fail, DC OK www.slpower.com CINT1175 REV 5.4, 6 April15 1

General Specifications (continued) Input Fuse 4A, 25VAC fuse provided on all models Overload Protection Hiccup Mode Earth Leakage Current <35µA@264Vac, 6Hz, NC Short Circuit Protection Provided no damage will occur if the output is shorted. Efficiency 9% typical at 115Vac Overvoltage Protection OVP firing reduces output voltage to <5% of nominal in <5ms. See chart for trip range. Output Power 175W continuous, with 2 lfm airflow, 12W convection cooled See chart for specific voltage model ratings. Switching Frequency PFC: 65kHz typical Transient Response 5% load step. i/ t: <.2A/µS Max Volt Deviation = 3% Isolation InputOutput: 4Vac InputGround: 18Vac OutputGround: 15Vac Ripple and Noise See chart Operating Temperature 1 C to +7 C Start Up at 4 C, full load Output Voltage See chart Temperature Derating Derate output power linearly above 5 C to 5% at 7 C Voltage Adjustability +/5% from nominal Storage Temperature 4 C to +85 C Minimum Load Not required Altitude Operating: 5 to 1, ft. Nonoperating: 5 to 4, ft. Total Regulation +/ 3%. See chart Relative Humidity 5% to 95%, noncondensing Vibration Operating:.3g/Hz, 1.5grms overall, 3 axes, 1 min/axis NonOperating:.26g2/Hz, 5.grms overall, 3 axes, 1 hr/axis Shock Operating: Halfsine, 2gpk, 1ms, 3 axes, 6 shocks total NonOperating: Halfsine, 4 gpk, 1 ms, 3 axes, 6 shocks total Dimensions W: 2. x L: 4. x H: 1.3 Safety Standards EN/CSA/UL/IEC 6951, 2nd Edition Weight 21g MTBF 331,15 hours, 175W load, 11Vac input, 25 C ambient Auxiliary Signals AC Power Fail: During normal operations, stays HIGH. Signal goes LOW with 5mS warning before loss of DC output from AC failure. DC OK: Open collector logic signal goes and stays HIGH 1mS to 5mS after main output reaches regulation. Inhibit: Connect to inhibit pin to output common to inhibit the DC output. www.slpower.com CINT1175 REV 5.4, 6 April15 2

EMI / EMC Compliance Conducted Emissions Radiated Emissions Static Discharge Immunity Radiated RF Immunity EFT/Burst Immunity Line Surge Immunity Conducted RF Immunity Power Frequency Magnetic Field Immunity Voltage Dip Immunity Line Harmonic Emissions Flicker Test EN5511/22 Class B, FCC Part 15, Subpart B, Class B EN5511/22 Class A, FCC Part 15, Subpart B, Class A w/6db margin EN6142, Criteria A, 6kV Contact Discharge, 8kV air discharge EN6143, 3V/m. Criteria A EN6144, 2kV/5kHz, Criteria A EN6145, 1kV differential, 2kV commonmode, Criteria A EN6146, 3Vrms, Criteria A EN6148, 3A/m, Criteria A EN61411, % Vin,.5cycle; 4% Vin, 5 cycles; 7% Vin, 25 cycles; Criteria A EN6132, Class A, B, C, & D EN6133, Complies (dmax<6%) Mechanical Drawing When installing the power supply into the endproduct, a nonconductive Insulator should be placed between the unit and any conductive metal chassis or mounting platform. www.slpower.com CINT1175 REV 5.4, 6 April15 3

Connector Information Input Connector J1 Ground J11 DC Output Connector J3 Fan Output Connector J5 Signal Connector J6 PIN 1) AC LINE PIN 2) EMPTY PIN 3) AC NEUTRAL.187 x.32 FASTON TAB PIN 1) +Vout PIN 4) Vout PIN 2) +Vout PIN 5) Vout PIN 3) +Vout PIN 6) Vout PIN 1) +12Vfan PIN 2) RTN PIN 1) Inhibit PIN 2) PF/DC OK PIN 3, 4) Common Molex 95331 Pins= 85272 Molex 1929 AMP 64256 Pins = 642521 Molex 1375822 Pins = 1375819 Molex 1375824 Pins = 1375819 Fan Output J5 J5 provides a 12V@.4mA output to support a system cooling fan. The fan output is always available when AC input is present, so it also can be used for a 12V standby output is so desired. AC Power Failure/DC OK and Inhibit Signals J6 Timing Sequence www.slpower.com CINT1175 REV 5.4, 6 April15 4

Isolation Specifications Insulation Safety Rating Electric Strength Test Voltage Input Specifications Input/Ground Input/Output Output/Ground Input/Ground Input/Output Output/Ground 18 4 15 Basic Reinforced n/a Vac Vac Vac All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Input Voltage 9 115/23 264 Vac TurnOn Input Voltage Ramping up 82.7 Vac TurnOff Input Voltage Ramping down 67. Vac Input Frequency 47 5/6 63 Hz Inrush Current Limitation 264Vac, cold start 5 A Power Factor Vi nom, Io nom.9 Efficiency Vi nom, Io nom CINT1175A126K1 CINT1175A156K1 CINT1175A246K1 CINT1175A486K1 CINT1175A566K1 9% % Output Specifications CINT1175A126K1 CINT1175A156K1 CINT1175A246K1 CINT1175A486K1 CINT1175A566K1 Vi nom,, Io1 @, TC = 25 C 3 3 % Vo nom Vi nom,, Io1 @, TC = 25 C 3 3 % Vo nom Vi nom,, Io1 @, TC = 25 C 3 3 % Vo nom Vi nom,, Io1 @, TC = 25 C 3 3 % Vo nom Vi nom,, Io1 @, TC = 25 C 3 3 % Vo nom CINT1175A126K1 CINT1175A156K1 CINT1175A246K1 CINT1175A486K1 CINT1175A566K1 Static Line Regulation V1 Vi minvi max, Vi nom, 1% Io nom 1 1 % Vo nom Static Load Regulation V1 (Droop Characteristic) www.slpower.com CINT1175 REV 5.4, 6 April15 5 1. 8. 5. 2.5 2.1 14.6.4 11.7.4 7.3.4 3.6.4 3.1.4 Vi minvi max, Vi nom, 1% Io nom 3 3 % Vo nom

Output Specifications (continued) HoldUp Time Starting at Vi = 23 VAC, Po nom 16 ms Dynamic Load Regulation Load change =5%, di/dt =.2A/µS voltage deviation 3% 3 StartUp Time Vi nom, Io nom 2 s % Vo nom Protection All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted Input Fuse Not user accessible Input Transient Protection 2KV(CM) and 1KV(DM) surge 2 KV (CM) Output Noload and short circuit proof short circuit proof overload (latch style) Hiccup or Latch Hiccup or Latch Hiccup Overvoltage Protection Latch style Latch Over temperature Protection Automatic power shutdown at TC =155 C Characteristic Curves Output vs. Temperature 12W convection cooled and 175W continuous with 2 LFM airflow, Derating output power to 5% at 7 C. www.slpower.com CINT1175 REV 5.4, 6 April15 6

Efficiency vs. Loading The high efficiency is achieved by using LLC technology, PFC topology minimizing switching losses. Synchronous SCHOTTKY or ultrafast diode is used as rectifier in CINT1175 family because of high output voltage level. Noise & Ripple To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with.1uf ceramic and a 1uF electrolysis capacitor connected in parallel across it, BW limit with 2MHz. www.slpower.com CINT1175 REV 5.4, 6 April15 7

Output Transient Response 5% load step within the regulation limits of minimum and maximum load, di/dt<.2a/µsec. Recovery time not specified as there is no laps in regulation with a 5% Load Step. Maximum voltage deviation is 3%, This test is performed on the MAIN OUTPUT ONLY. Output Overload Characteristic Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention. Output Overshoot When supply is turned on, off or when the load is stepped 1%, the Power Supply Overshoot/Undershoot shall not exceed minimum or maximum of output voltage regulation. www.slpower.com CINT1175 REV 5.4, 6 April15 8