SI410 Sintony Intrusion Control Panel

Similar documents
SI220 Sintony Intrusion Control Panel

Intrusion Panels Low Segment Panels SI80 / SI100. SiRoute. Passive infrared detector Outdoor siren. Door contact. Indoor siren.

IC60 Sintony 60 Intrusion Control Panel

WaterCress Portfolio

ACS-8-System. Access Control. Performance features at a glance

FC724 Fire control panel

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

FC722 Fire control panel

Intrunet. SPC series Planning guide. Answers for infrastructure.

ACS-8-System. Access Control. Performance features at a glance

TM50 Touch Intuitive Touchscreen

VizioGuard Tiny. Datasheet

Building Technologies. Access Control SiPass networked - simple & networkable for everyday use

FC726 Fire control panel

EN54-16 COMPLIANT HARDWARE BYPASS MICROPHONE PORTS 12 ANALOGUE AUDIO INPUTS 12 GPIO INPUTS & 12 OUTPUTS 12 ANALOGUE AUDIO OUTPUTS

FC726 Fire control panel

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

R165D5GB5GM21-4T Specification Sheet. R165D5GB5GM21-4T Specification Sheet. Advanced. Intelligent. REVO.

Industrial Power Supplies

ET 908. IP-Intercom Module ET 908 DATASHEET PRELIMINARY

FC2080 Fire control panel (modular)

Technical Manual Nova: Cabinet Security Management System (CSMS)

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

Video kit with 1 hands-free internal unit, surface-mounting. Video kit with 2 hands-free internal units, surface-mounting

660/960 Installation Guide

CPS kVA TRIFASE EN50171

Clear Benefits of the KRAL Electronic.

ACCESS CONTROL SYSTEM

R165D2GT6GM21-2T Specification Sheet. R165D2GT6GM21-2T Specification Sheet. Advanced. Intelligent. REVO.

S-Vision. The Digital Video Surveillance System of Shuttle for Home and Office Applications

R165D3GT3GB3GM21-3T Specification Sheet. R165D3GT3GB3GM21-3T Specification Sheet. Advanced. Intelligent. REVO.

Industrial Power Supplies

Product Datasheet. NK8223 Ethernet Port

AC-DC Converter REC /60-K20

IP Desktop Intercom Stations 12 NIB 001 Series

Programmable Switching DC Power Supply

Accessories and options

Secure Your Way of Life. Now Compa ble With. HSVGW-G Series Home Security Voice Gateway Series. Take Smart Living Up a Notch

TAC I/NETTM 1284, 1280, Security Control Unit

RFID PRODUCT AND SYSTEM

CA-A480-A Elevator Controller. Reference & Installation Manual

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

FT724. Fire terminal. Cerberus PRO. FS720 series, IP6

Compact Intercom Server GE 100

Net: EUR Gross: EUR

Interface converter for VAV compact controllers

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

RL161HD5GB5G-1T Specification Sheet RL161HD5GB5G-1T. Advanced. Intelligent. REVO.

Installation Manual for D244X Series 24-volt Power Supplies

Automated Remote Messaging ARM-911A RM-911D RM-911W

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

AC-DC Converter RECE K21

INTEGRA Firmware version 1.11

CallRecorder. Silver Line Octo Quarto ISDN ll PRI

AC5160 SiPass integrated controller kit

Dupline Fieldbus Components

3RG7 Opto-BERO Photoelectric Proximity Switches

Weighing Indicator. Features. Description. Applications

_ Access control SISTEMAS DE SEGURIDAD

GSM Voice Active Monitoring OTP-GSM89

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

MDC-20. Maximum Demand predictive Control. Description

1/5 SING.-FMLY KIT W/VANDALCOM & PC INTERCOM VIP SYST. KIT H.264 OVERVIEW 8504H

Digital Intercom Stations DTM Series

Product Datasheet NK8225 Ethernet Port with BACnet Gateway

AP 701 Access Panel. Features and Functions

Digital input modules

MCS 50. Discussion Control Unit. 1 of 7

Pegasus Equipments Export Limited. Local Contact:

2-Way Wireless I/O Expander Installation Guide

The Cardax FT Controller 6000 can support up to 16 GBUS devices.

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Models 300, 310, 320, 330 PROTECTIVE AND SUPERVISION STORAGE CABINET FOR AUTOMATED EXTERNAL DEFIBRILLATORS (AED)

PRO3200 Professional Modular Access Control Hardware

Extruder Controls ExtruVision S

UC-2000 Installation Manual Unicorn Computers Technology Limited

The Packs Infotel. GSM Converter V2. Installation Manual V7

DORMA. Access Control

APP 700 Technical Specification

Access Terminal IF-800

ProLine GSM. Installation manual

AC-DC Converter REC K10

Low-Light Color High Speed Dome Camera

Industrial Control SE-607

AUTROVOICE MULTIVES EXCHANGEABLE MODULES

Double-channel measuring and control instrument for free chlorine and ph-value - additionaly ORP optional

PoE IEEE802.3at MIFARE MHz. EM 125 KHz

RL81D2IT4I-1T Specification Sheet RL81D2IT4I-1T. Advanced. Intelligent. REVO.

Intelligent Four Lift Controller TS0869

GE 800. Digital IP-Intercom Server GE 800 DATASHEET

USER S MANUAL Power Supply for Backplane Vdc

FT2040 Fire terminal. Sinteso. FS20 series

The speaking controller

4 balanced inputs 1 relay output

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

WIRELESS S Y S T E M S

Modules Programming Guide. paradox.com

R165D5GT7GM23-8T Specification Sheet. R165D5GT7GM23-8T Specification Sheet. Advanced. Intelligent. REVO.

Gas Controller System DGC-06

Transcription:

SI410 Sintony Intrusion Control Panel Perfect building protection inside and outside Multifunctional intrusion control panel Modular design Extensive assortment of functional modules Flexible configuration Communication via analog network, ISDN and IP 16 areas which can be combined as needed Up to 128 activation wards 20 calendars which are programmable two years in advance 16-464 addressable inputs 11-274 programmable outputs 497 definable movement corridors Various different alarm verification methods Remote configuration and maintenance using Sylcom software Macro programming for enhanced functions Integration of SiRoute wireless systems Fire Safety & Security Products Building Technologies Group

Sintony 410 The multifunctional intrusion control panel not only provides specific functions for the highest security demands. It allows for additional security applications such as access control using card readers or local video surveillance. The modular design with a wide range can be adapted to the customer needs and grow with increasing requirements. Flexible configuration allows for adjustment of the system to fit individual processes, topologies or security concepts. A wide variety of communication options allows for cost-efficient solutions for configuration, maintenance, alarm transfer, control and monitoring of the center using analog and IP networks or ISDN. 20 calendars with a wide array of time functions can be allocated to control units, users, inputs or outputs, thereby providing optimum support for scheduled procedures within a company. Up to 500 movement corridors can be defined. And this can be done up to 2 years in advance. Various types of alarm verification help prevent false alarms caused by incorrect operation or detection, thereby avoiding stressful situations and costly intervention measures. Several events can be filtered before the alarm is signaling or the alarm transmission can either be delayed or confirmed. In addition to this, the audio and video components enable listening, speaking and seeing events inside the building. The Sylcom Software can be used for configuration and maintenance of the Sintony control panel. The system can be accessed locally or via analog and IP networks. Sylcom can also be configured as a un-operated parameter server, which the control panel can access to compare the parameters via remote for optimum system data management. The macro programming language can be used to implement customer specific applications inexpensively. Complex functions can be implemented using the available functions for linking conditions, timers, variables or control units. The 464 inputs and 274 outputs can be programmed as needed. This can be used to monitor and control numerous points in a large building, to activate system functions or to signalize events. 16 alarm and 128 activation areas as well as free configuration of area dependencies allow for easy transfer and administration of customer specific organizational structures in the system. SiRoute radio system integrates all wireless components such as remote controls, sirens, motion and smoke detectors, input and output modules or door contacts into the panel. This embedding system saves you installation time and efforts when covering locations that are difficult to access.

E-Bus All Sintony intrusion control panel are equipped with shapely, user-friendly keypads with plain text displays and operating support for internal and external activation and deactivation of security wards, quick contact checks and hidden triggering of robbery alarms. Illuminated keys and LCD display. SAK41 LCD keypad with flap The SAK41 is equipped with a 2-line display, each consisting of 16 characters. The display and the keys are fitted with backlights. The 5 LEDs display the most important system states such as on/off, ward unset, part set, full set, alarm, etc. The keypad is equipped with a cover. SAK51 LCD keypad The SAK51 is equipped with a 2-line display, each consisting of 16 characters. The display and the keys are fitted with backlights. The 5 LEDs display the most important system states such as on/off, ward unset, part set, full set, alarm, etc. SAK52 LCD keypad with audio function The SAK52 is identical to the SAK51. The added audio function (microphone and loudspeaker) supports applications such as alarm verification and remote help. SAK53 LCD keypad with flap and large display The SAK53 is equipped with a removable cover and an extra-large 2-line display, each consisting of 16 characters. The display and the keys are fitted with backlights. The 5 LEDs display the most important system states such as on/off, ward unset, part set, full set, alarm, etc.

E-Bus A large assortment of plug-in modules and peripherals such as LCD keypads, addressable expanders for inputs and outputs, card readers or external power supplies are available for professional installation. The panel feeds, controls and monitors the modules, which can be installed in any topology in the building. SAT12 transponder in housing Sintony control panel extension by 4 programmable inputs and 2 outputs via the E-Bus. 2 of these inputs can be used to connect glass break detectors. SMT12 transponder board only This unit is identical in function to SAT12, but without housing. It is installed directly in the control panel, in the external supply or in the universal housing unit SAH24. SMT44 output transponder board only This module is used to extend the center by 8 additional outputs (4 OCs and 4 relays). It is installed in the control panel housing, in the external supply or in the universal housing unit SAH24. SMG71 card reader interface The SMG71 is used to connect Wiegand readers to the Sintony 410. It is possible to connect up to 2 card readers with Wiegand protocol to each module. Each module is equipped with 4 outputs and 2 inputs. Up to 32 SMG71 units can be connected to the Sintony 410. It is installed in the control panel housing, in the external supply or in the universal housing unit SAH24. SAG91 E-Bus concentrator The SAG91 can be used to increase the number of conventional inputs in the Sintony 410. A single system can manage 4 SAG91 units and each extension allows for connecting 20 SAT12 or SMT12 modules.

E-Bus This cost-effective type of installation allows for placement of the modules where they are needed in the building. The modules can be addressed at the push of a button. In addition to this, the E-Bus can be separated into independent, galvanic isolated wards for increased security. SAR11 E-Bus Isolator/repeater E-bus in housing The SAR11 can be used to divide the incoming E-Bus into two independent, electrically separated supply wards. In addition to this, the E-Bus signals can be received over great distances with this module. SMR11 E-Bus Isolator/repeater board only This module is identical to SMR11, but without housing. It is installed directly in the control panel, in the external supply or in the universal housing unit SAH24. SAP14 power supply 12 VDC / 1.3 A in housing The external power supply SAP14 includes a bus-monitored /1.3A supply, 4 secured 12V outputs and a freely programmable relay output with 48V/5A. The housing includes additional space for 4 SMT12/SMR11 modules and either a 17Ah battery or a 7.2Ah battery with 2 SMX13 relay cards. SAP20 power supply 12 VDC / 2.3 A in housing The external power supply SAP20 includes a bus-monitored /2.3A supply, 4 secured 12V outputs and a freely programmable relay output with 48V/5A. The housing includes additional space for 7 SMT12/SMR11 modules and either a 27Ah battery or a 7.2Ah battery with 2 SMX13 relay cards.

WMA11 E-Bus Audio bus Video bus WMV12 The Sintony intrusion control panel provides an integrated solution for remote acoustic and optical alarm verification. The building can be divided into 6 different verification zones, in which a surveillance control panel can listen or see after an alarm and communicate with people. It also provides the option of requesting remote support using the keypad. WMA11plug-on audio module The WMA11 audio module is the interface for the audio bus and is simply mounted on the Sintony mainboard. The audio bus allows for 2-way transfer of acoustic signals between the audio components and the control panel. The module also decodes the DTMF signals of a telephone, thus enabling control panel via telephone keys. WAC12 loudspeaker and microphone (2-way audio) The WAC12 is a combined loudspeaker/microphone solution, which is controlled via the E-Bus. It is possible to connect 3 WAC11 or WAS11 microphone/loudspeaker units to the WAC12 to extend acoustic coverage. WAC11 loudspeaker and microphone (2-way audio) The WAC11 is a combined loudspeaker/microphone solution, which can either be connected to the WAC12 or directly to the WMA11. The LED, which is lightening during microphone activation, can be switched off. WAS11 microphone unit The WAS11 can either be connected to an addressable WAC12 device or directly to the WMA11 audio module. The WAS11 is equipped with a sensitivity controller. SAK52 LCD keypad with audio function The SAK52 is identical to the SAK51. The added audio function (microphone and loudspeaker) supports applications such as alarm verification and remote help.

E-Bus Audio bus Video bus The detectors can be linked to the verification zone so that the allocated module within the building is activated directly following an alarm. The audio bus and the video bus can be installed in the same cable as the E-Bus for simple, cost-effective alarm verification. WMV12 plug-on video module The WMV12 video module is the interface for the video bus and is simply mounted on the Sintony mainboard. A monitor can be connected to check camera availability at the push of a button. In the case of alarm, 6 images from the allocated camera are stored digitally and transferred to the emergency center with alarm notification. The WMV12 is not required for local surveillance. WAV61 monitor interface The WAV61 monitor interface enables connection of a monitor or video recorder to the video bus for local video monitoring. It can be used to view and record the existing images from WAC32 or WAT21. WAT21 video camera interface The WAT21 E-Bus connection is used to connect a Siemens or industry-standard video camera to the video bus. In addition to this the module has interfaces for the microphone/loudspeaker modules WAC11 and WAS11. A relay output also signalizes activation of the interface subsequent to an alarm (e.g. to switch on external infrared lighting). WAC32 E-Bus camera The WAC32 includes a camera, a loudspeaker and a microphone. The camera does not depend on surrounding lighting due to integrated infrared lighting. Therefore the WAC32 is especially suited to difficult ambient conditions.

PSTN CMS Receiver SML61 SML51- SMN36 IP ISDN Telephone Service PC Surveillance system SMV11 There are several communication modules available for the Sintony intrusion control panel, which can be implemented for alarm transfer, configuration and maintenance. The Sylcom Software provides a cost-effective maintenance of the system. SML51-TBR dialer board PSTN The SML51-TBR dialing device connects the Sintony with the analog telephone network (PSTN). It supports the various different remote applications such as alarm transfer, audio/video alarm verification, configuration or maintenance. Used in connection with the SMV11, individual voice messages can also be transferred. SML61 dialer board ISDN The SML61 dialing device connects the Sintony with the digital network (ISDN). It supports the various different remote applications such as alarm transfer, audio/video alarm verification, configuration or maintenance. Used in connection with the SMV11, individual voice messages can also be transferred. SMN36 IP interface module The SMN36 IP module connects the Sintony with IP networks. It supports the various different remote applications such as alarm transfer, configuration, maintenance, system control or monitoring. In addition to this, the conventional dialing devices can be used for redundant transfer. SMV11 voice module The SMV11 stores 6 alarm messages, 4 help messages and an identification message, which can be recorded individually with the integrated microphone.

Overview system technology Standard SI410 (expansion Expandable to options) Inputs and outputs Inputs 16 464 Outputs 11 274 - OC 12V / 0.15A 7 243 - OC 12V / 1A 1 1 - Relay 12V / 2A with 1 changeover contact 1 7 - Relay 12V / 2A with 2 changeover contacts 1 7 - Relay 48V / 5A 1 16 Functions Independent alarm wards 16 Activation wards 128 Physical input types (freely selectable for each input) 7 Logical input types (freely selectable for each input) 49 Logical output types (freely selectable for each input) 50 Automatic test function for seismic detectors Event memory with time stamp and additional information 1500 PINs for users / installer 497 / 3 2-year calendar 20 Time control for control panel, users, inputs and outputs Various different alarm protocols Local RS232 printer connection Local RS232 PC connection Macro programming (SAS97) Connections for external systems Remote maintenance and configuration (SAS31) Plain text programming using control unit or PC Operation LCD keypad (SAK41 / SAK51 / SAK52 / SAK53) 32 Activation without code Plain text user support System control unit Communication Analog PSTN dialing device (SML51) Digital ISDN dialing device (SML61) IP communication module (SMN36) Voice alarm via telephone (WMA11) System control via telephone (WMA11) Multiple alarm protocol transfer Transfer to backup alarm receiver Line extensions Input/output module without SAG91 / with SAG91 (SAT12 / SMT12) 32 /112 E-Bus concentrator (SAG91) 4 Output module (SMT44) 3 Power supplies Integrated power supply 1 External power supplies (SAP 20 / SAP14) 15 Output load of the monitored power supplies (nominal voltage 12V) 2.3 A 36.8 A Secure 12V outputs 4 64 Battery and network monitoring Sabotage monitoring Installation of additional modules possible Card reader Card reader module (SMG71) 32 Card reader for each module 2 64 Offline mode "Autoshunt" function Audio and video functions Independent verification zones 32 Event-controlled verification zones Call-back for alarm verification 2-way audio bus for alarm verification and intervention (WMA11) Video alarm verification with image storage (WMV12) Connection for local image playback on monitor or video recorder (WAV 61) Remote help (audio support) Wireless SiRoute wireless gateways (W7EG10) 4 SiRoute wireless inputs 12 48 SiRoute wireless outputs 5 20 SiRoute wireless remote controls 7 28 Automatic wireless network routing Bi-directional wireless system

Technical specifications SI410UK SAP20 SAP14 Power supply 230VAC +10%/-15%, 50 Hz 230VAC +10%/-15%, 50 Hz 230VAC +10%/-15%, 50 Hz Main fuse T500mA T500 ma T200mA Power consumption max. 230 ma max. 230 ma max. 160 ma Ripple output voltage 200 mvpp at 2.3A 200 mvpp at 2.3A 60 mvpp at 0.8 A Power supply output voltage / nominal voltage 12 VDC / 2.3 A SMP20 12 VDC / 2.3 A SMP20 12 VDC / 1.3 A SMP14 Mainboard power min. 150mA consumption max. 200mA Battery type (optional) 12 VDC / 27 Ah 12 VDC / 27 Ah 12 VDC / 17 Ah Inputs 16 Outputs Operating temperature (93% relative humidity) 1 relay 48V / 5A 2 relays 24VDC / 2A 7 OC / 150mA 1 relay 48V / 5A 1 relay 48V / 5A -10 ~ +40 C -10 ~ +40 C -10 ~ +40 C Housing protection class IP30 IP30 IP30 Housing material Metal housing 1.5 mm Metal housing 1.5 mm Metal housing 1.5 mm SAK41 SAK51 SAK52 SAK53 Power supply 12 VDC 12 VDC 12 VDC 12 VDC Main fuse Power consumption min. 13 ma max. 73 ma min. 13 ma max. 73 ma min. 18 ma max. 114 ma min. 23 ma max. 120 ma LCD display 2 x 16 characters 2 x 16 characters 2 x 16 characters 2 x 16 characters Operating temperature (93% relative humidity) Housing protection class? -10 ~ +55 C -10 ~ +55 C -10 ~ +55 C -10 ~ +55 C Housing material ABS ABS ABS ABS Power supply Power consumption Power restriction SAT12 / SMT12 SMT44 SAR11 / SMR11 SMG71 SAG91 min. 6 ma max. 19 ma min. 42 ma max. 66 ma min. 15 ma max. 35 ma 400mA E-BUS output min. 11 ma max. 35 ma min. 6 ma max. 19 ma 400mA E-BUS output Battery (optional) Inputs 4 4 Outputs 2x OC / 150mA 2 x relay 24VDC / 2A 2x OC / 150mA 4x OC / 150mA Card scanner protocols Wiegand and ABA Track 2 Card scanner for each 2 max. module Operating temperature (93% relative humidity) -10 ~ +55 C -10 ~ +55 C -10 ~ +55 C -10 ~ +55 C -10 ~ +55 C Housing protection class IP30 IP30 IP30 IP30 IP30 Housing material ABS ABS

Technical specifications WAC12 WAC11 WAS11 WAV61 WAT21 WAC32 Power supply Power consumption Battery Loudspeaker power Audio bus Audio bus min. 5 ma min. 12 ma max. 24 ma max. 7 ma max. 3 ma typ. 23 ma max. 107 ma min. 15 ma max. 1000 ma NiCd battery Charging 2W Microphone activation Display via LED Display via LED Display via LED Display via LED Camera Camera lens Camera IR lighting Inputs Outputs 1 Vpp for Monitor/VCR 1 Vpp for Camera 1 Vpp for Monitor OC 12 V/150 ma active LOW with 40 Ohm serial resistance LCD 1/3 ; 0.5 Lux; 300000 pixels, 3.8 mm 12 diodes 1 Vpp for monitor Sabotage signalizing Via E-Bus NC contact NC contact NC contact Via E-Bus Via E-Bus Bus connections Operating temperature (93% relative humidity) E-Bus Audio bus Video bus E-Bus Audio bus Video bus E-Bus Audio bus Video bus -10 ~ +55 C -10 ~ +55 C -10 ~ +55 C -10 ~ +55 C -10 ~ +55 C 0 ~ +40 C Housing protection class IP30 IP30 IP30 IP30 IP30 IP30 Housing material ABS ABS ABS ABS ABS ABS WMA11 WMV12 SMV11 SML51 SML61 SMN36 Power supply Mainboard Mainboard Mainboard Mainboard Mainboard Mainboard Power consumption min. 10 ma max. 100 ma min. 8 ma max. 160 ma min. 3 ma max. 25 ma min. 4 ma max. 82 ma min. 4 ma max. 82 ma Operating temperature (93% relative humidity) -10 ~ +55 C -10 ~ +40 C -10 ~ +55 C -10 ~ +55 C -10 ~ +55 C Technical note: A) Use of external power supply is recommended behind the output of SAR11/SMR11 and SAG91 (otherwise output current is limited to 400mA). E-Bus sections with more than 20 addressable E-Bus modules must be separated by an SAR11/SMR11 or SAG91. B) SMG71 or SAP25 cannot be addressed behind an SAG91. C) To use more than 8 card reader gateways SMG71, the index C2 or higher is required.

Ordering information Type Item No. Designation Dimensions (WxHxD in mm) Weight SI410UK BPZ:8008080001 Sintony control panel SI410UK (English version) 365x505x133 8.600 kg SAK41 BPZ:8006590001 LCD keypad with flap 110x166x30 0.250 kg SAK51 BPZ:8006630001 LCD keypad 170x110x30 0.220 kg SAK52 BPZ:8006930001 LCD keypad with audio function 170x110x30 0.250 kg SAK53 BPZ:8006940001 LCD keypad with flap and large display 170x110x30 0.270 kg SMT44 BPZ:8006730001 Output transponder board only 156x55x20 0.090 kg SAT12 BPZ:8006150001 Transponder in housing 135x86x27 0.130 kg SMT12 BPZ:8006160001 Transponder board only 90x52x20 0.050 kg SMG71 BPZ:8006600001 Card reader interface 156x55x20 0.120 kg SAG91 BPZ:8009740001 E-Bus concentrator 135x86x27 0.130 kg SAR11 BPZ:8000990001 Isolator/repeater E-Bus in housing 135x86x27 0.130 kg SMR11 BPZ:8001090001 Isolator/repeater E-Bus board only 90x52x20 0.050 kg SAP14 BPZ:8003160001 Power supply 12 VDC / 1.3 A in housing (without battery) 303x405x88 5.400 kg SAP20 BPZ:8006880001 Power supply 12 VDC / 2.3 A in housing (without battery) 365x505x133 8.400 kg WMA11 BPZ:8000310001 Plug-on audio module 113x60x26 0.060 kg WMV12 BPZ:8000040010 Plug-on video module 130x118x24 0.130 kg WAC12 BPZ:8007720001 2-way audio unit with loudspeaker/microphone (addressable) 105x145x70 0.240 kg WAC11 BPZ:8000110001 2-way audio unit with loudspeaker/microphone 105x145x70 0.240 kg WAC32 BPZ:8001750001 E-Bus camera with IR lighting 85x215x120 0.450 kg WAS11 BPZ:8005230001 Microphone unit 77x77x35 0.070 kg WAV61 BPZ:8003430001 Monitor interface 135x86x27 0.120 kg WAT21 BPZ:8002150001 E-Bus camera interface 135x86x27 0.140 kg SMV11 BPZ:8000440001 Voice module 106x60x26 0.060 kg SML51TBR BPZ:8003480001 Dialer board PSTN 140x50x24 0.070 kg SML61 BPZ:8003970001 Dialer board ISDN SML21 BPZ:8000530001 Line monitoring for analog telephone network 50x31x20 0.020 kg SMN36 A6E80117810 IP-interface module 111x60x35 0.070 kg SMX13 BPZ:8009180001 Relay module 60x38x20 0.030 kg SMZ93 BPZ:8007270001 Breakaway contact for Sintony 410 SAH24 BPZ:8004370001 Plastic housing for module 215x130x35 0.180 kg W7EG10 BPZ:8010650001 SiRoute E-Bus gateway 135x86x27 0.130 kg SAQ11 BPZ:8001960001 PC/printer cable 0.090 kg SAQ18 BPZ:8006410001 X.25 cable 0.090 kg Siemens Schweiz AG International Headquarters Gubelstrasse 22 CH 6301 Zug Switzerland Tel. +41 41 724 24 24 Fax +41 41 724 35 22 www.sbt.siemens.com 2006 Copyright by Building Technologies Group Subject to delivery conditions and technical changes. Document No. 009174_a_de_-- Manual - Edition 03.2006 Register -