Electro Magnetic Compatibility (EMC)

Similar documents
Colour Observation Camera

RS232 Control Box. Table of contents

Electro Magnetic Compatibility (EMC)

Monochrome Camera. Features. User manual

SERVICE MANUAL 1/3 SONY DSP COLOR CCD CAMERA OVER 650TVL SERIES

CF /BF SERIES CAMERAS

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

SECTION 1 GENERAL DESCRIPTION

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

Please refer to the table below for the features of individual camera models.

SERVICE MANUAL 1/3 SONY DSP COLOR CCD CAMERA 600TVL O.S.D. WDR SERIES

IR Varifocal IP66 Weatherproof Cameras

Industrial Camera GP-MF602. Before attempting to connect or operate this product, please read these instructions completely.

Weatherproof IR Color Day/Night Cameras

D/N VARI-FOCAL IR CAMERA

Heat-sensing Bullet CCTV Camera

Fixed Color Cameras Installation Manual INTRODUCTION These instructions cover the American Dynamics ADCA470 and ADCA330 series of color cameras Read a

Video surveillance camera Installation Guide

Spectrum Laser. User manual UK. Version 1.0

DAY AND NIGHT COLOR CAMERA

INSTRUCTION MANUAL BEDIENUNGSANLEITUNG MANUEL D INSTRUCTIONS VCC-3924P. COLOUR CCD camera CCD-Farbkamera Caméra CCD COULEUR

Blue Weapon Laser. User manual UK. Version 1.0

CCD COLOR CAMERA BDC4803VFD USER MANUAL. Page : 1

B/W PAN/TILT FIXED DOME CAMERA

5 B&W Rear View System Camera

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera

KTC-205C Color Camera

USER GUIDE LPRCAM. License Plate Capture Bullet Camera. For license plate capture only. This technology will not take pictures of surrounding areas.

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

Camera Features. Package Contents. Camera Features

Wide Dynamic Range Dome Camera WDR-D3

CCD COLOR CAMERA BDC4803VF USER MANUAL. Page : 1

D/N VANDAL RESISTANT ATR 700TVL VARI-FOCAL DOME CAMERA CMD6182X/6186X3.6 N/P

ACC484TP(X) 1/3 HIGH RESOLUTION FULL-FEATURED COLOR CAMERA. Features:

Outdoor IR Camera. DVR / Camera Communication System Series

Instruction Manual. Hidden CCD Camera VK-1321/PIR (B&W), VKC-1338/PIR (Colour)

Analog Speed Dome. New 1/4 Sensor. Privacy Masking. Multi-Protocol Telemetry. IP66 Protection. Designed For Constant Use.

Infrared Dome CCD Camera User Manual

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

OPERATING MANUAL DIGITAL COLOR CCD CAMERA OKI USA DAY & NIGHT SERIES

IGLOO IGLOO EASY INSTRUCTION MANUAL

High Resolution Indoor Dome Camera

3-AXIS GIMBAL VARI-FOCAL INDOOR DOME CAMERA

9.2 TFT LCD COLOR MONITORING SYSTEM With 2 Indoor/Outdoor Color Cameras

Architecture and Engineering Specifications SANYO VCC-HD2500P 4 Megapixel Full-HD Advanced Day/Night CS Box Camera

3D OBJECTS RGB LASER. Order ref: UK User Manual

Network Camera. Quick Guide DC-B1203X. Powered by

LED W RGBA User Manual

SUBWOOFER SYSTEM YST-MSW10

1/3" Sony color CCD camera

Digital Color Cameras

KC452xMx/KC652xMx USER MANUAL 1/3" BLACK-AND-WHITE CCD CAMERA

Instruction Manual. English Version 2.0

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

Dahua HAC-ME1500D active deterrence camera

IR Bullet Camera User Manual

CM-Z2212GY. Outdoor IR Speed Dome PTZ Camera

PLCMTR Commercial Grade Camera System

INSTRUCTION MANUAL. Security Camera. Indoor/Outdoor Color Camera w/ Night Vision. Version 1.0. now you can see. Model# VU5

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

3D FPV camera The BlackBird 2. User manual

AMP20. User Manual.

COLOR USB CAMERA. W-01U2 (Preliminary Specs SUBJECT TO CHANGE) For more details, see NEW ITEM.

HDCVI Compact Mobile Camera User s Manual

WARNING & SAFETY PRODUCTS

B&W RearView Camera Installation & Operation

SA-36 PTZ series SS316L analogue PTZ camera station

TVAC25100 TVAC25110 User manual

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

Cisco Video Surveillance 2621V IP Dome

Industrial B&W CCD Camera

CONTENTS PRODUCT FEATURES EG-2

IGLOO IGLOO EASY INSTRUCTION MANUAL

Dahua 4x2MP IR Dome Network Camera

TA12 full-rangespeaker. user manual

VIDEO DOORPHONE SYSTEM

THE INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL CODES.

SP mm F/2.8 Di VC USD (Model A009)

5.6 Color Rear View Safety System Installation & Operation. RV56 (Includes MO56 monitor & CA56 camera)

INFRARED ILLUMINATOR HOUSING 60M

PORTABLE HOME SECURITY VIDEO CAMERA

CS-1 Active Full Range Integrated Commercial Audiovisual System

CMOS HD Digital Camera User's Manual

CAMit I Camera with built in Modem

IR Dome Camera User Manual

EX-BC36 PTZ series Explosion-proof analogue PTZ camera station

Eyemax 1080P Starlight True WDR IR Dome Camera with 2.8mm Lens

Lens Backfocus & Adjustment Procedures. 1. Backfocus

IR Dome Camera. User Manual UD.6L0201D0092A02

IR Dome Camera User Manual

User's Guide. Model W 3-in-1 Switching DC Power Supply

Infrared Illumination Camera

VPC-64/ VPX-64 VIDEO POLE CAMERA OPERATION MANUAL

Table of Contents. Camera Care. Handling the camera. Camera base. Warnings. Table of Contents. Camera Care

1. REMOTE SENSOR 2. A/V IN JACK 4. DC 12V IN 5. TFT-LCD SCREEN 6. EARPHONE JACK 7. SPEAKER 9. TV/AV BUTTON 13. ROD ANTENNA 14.

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

Digital Display Company

Monochrome Cameras LTC 0140 LTC 0142 LTC Eng. Philips Communication & Security Systems

High Contrast License Plate Capture Camera

Transcription:

Electro Magnetic Compatibility (EMC) This equipment complies with the European rules for EMC according to EN5501, EN5500 and EN5008-1. The equipment conforms to the EMC directive and low-voltage directive. This device complies with EMC rules under test conditions that included use of system cables and connectors between system components. If you have any problems, contact your dealer. English Warning Any unauthorized modification to this equipment may cause violation of the EMC rules resulting in the revocation of the authorization to operate the equipment. The exclamation mark within a triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. Note: We advise you to use the following types of mains power adaptors in combination with the camera: UK Philips VCM116/01R EUR Philips VCM116/00R English

Colour Observation Camera English Table of contents Page Introduction... 4 Connection and operation facilities... 5 Installation... 5 Camera position Focus adjustment Back-focus adjustment Camera sound on/off Outdoor use Using a different lens... 9 4mm/F1. lens 8mm/F1. lens 4mm/F1. auto-iris lens 8mm/F1. auto-iris lens Changing a lens... 11 System cable... 1 Tips for maintenance... 1 Read these instructions, before taking your system in operation.

Introduction This camera is especially designed for the Philips Observation System. It can be used in combination with a system monitor (System, Quad or Slave). The System and Quad monitor provides input for up to 4 cameras. The slave monitor can handle 1 camera in a stand-alone configuration. The camera has a standard camera mount allowing installation on, for example, a tripod or wall bracket. Power supply: The safe low voltage (16-V ) for the camera and system accessory is supplied by the monitor through the system cable. If the length of the system cable is more than 00m/600ft a mains power adapter should be used to provide the camera power supply. Camera accessories: The following camera accessories are available: Auto-iris lens 4mm (F1.) Auto-iris lens 8mm (F1.) Protective camera housing Mains power adapter 4

FAR < > NEAR Connection and operation facilities 1 Focus adjustment ring Back-focus adjustment ring 1 CL 66610005_10b.AI Camera sound on/off 4 Auto-iris socket 5 Cable length compensation selector 6 System cable socket 7 External supply socket 0 1 100m 0-50m 00m 00m 4V + - 7 4 5 6 CL 66610005_11b.AI Installation This chapter describes the installation of the camera. For more detailed information about the installation and operation of the system monitor and accessories (optional) you should consult the monitor and/or accessory manuals. Remark: When the system configuration is altered, the system monitor needs to check and memorise the cameras and accessories connected to its inputs. This is done automatically when the power is switched on. Use the power switch to switch off, only operating the power save key is not sufficient. If switching off is impracticable, use the auto install option of the system monitor s install menu. Caution: Never touch the glass of the camera lens as this may cause damage. 5

Camera position 1 Take the camera, system cable and monitor to the area you want to observe (with the monitor on site, you can check whether the camera covers the required area). Remark: For outdoor use protective camera housing has to be used to protect the camera from rain and snow. Connect the camera to the system monitor (1). Connect the system monitor to the mains (). 4 Switch on the mains power switch (). The monitor will check the system. After about 0 seconds or when a key is pressed the camera image will appear on the monitor screen. camera in slave 1 4 out video audio in out VCR out aux max 4V A out alarm gnd power 1 CL 66610005_14A.AI 5 If necessary adjust contrast /brightness and/or colour (controls at the front of the monitor) to optimise the camera image. 6

6 Hold the camera at the proposed installation position 7 Check on the monitor whether the camera covers the required area (The best results are obtained when the camera is pointed 1/4" 0 UNC slightly downwards and is not looking into a bright light source). Adjust focus 1 if necessary. 8 Fasten the wall bracket (1) to the wall, or another even and firm surface. 9 Tighten the knob (). 10 Fasten the camera to the bracket (). 11 Loosen knob (4) and screw (5) slightly (figure below). 1 Direct the camera at the object or area you want to observe (8). Check the camera image on the monitor. Adjust focus if necessary. 1 Tighten the knob (4) and screw (5) when the camera is in position. CL 66610005_0.AI 8 5 7 4 0 1 100m 00m 0-50m 00m 4V + - 6 CL 66610005_0.AI 7

14 Check if the cable length compensation (6) selector is set to the correct length. The length set must be the same as the length of the system cable (0-00m/900ft max.) connecting monitor and camera. Remark: If the length of the system cable is more than 00m/600ft, a mains power adapter (optional) should be used (the max. allowed cable length is 00m/900ft). Connect the adaptor to the mains and to the external supply socket (7) at the back of the camera. Focus adjustment Adjust the focus ring of the camera lens to obtain optimal image sharpness. Remark: If still no sharp object image is obtained, you should adjust the back-focus of the camera. Back-focus adjustment 1 FAR < > NEAR Caution: Back-focus adjustment is only necessary when no CL 66610005_04B.AI sharp object image is obtained with the focus adjustment ring. Set focus adjustment ring to Far or Infinity (1). Aim the camera at an object at least 15 metres/45 feet away. Remark: When bright light sources are positioned within thecamera view field; dim the light source. Loosen the back-focus locking ring (). Rotate the lens, including the CS-mount ring, until the video image on the monitor is sharp. Tighten the back-focus locking ring (), while keeping the lens in place. 1 FAR < > NEAR CL 66610005_05.AI 8

Camera sound on/off Use switch (9) to enable or disable the built-in camera microphone. Outdoor use For outdoor use a protective cover has to be used to protect the camera. Remark: When the camera is used outdoors an auto-iris lens is recommended. 9 On Off CL 66610005_06.AI Using a different lens The CS-mount of the camera allows you to use other lenses. The field of view (= covered area) of an 8mm lens is half of the field of view of the 4mm lens (see figure below). Lenses available are: 4mm/F1. lens 8mm/F1. lens 4mm/F1. auto-iris lens 8mm/F1. auto-iris lens The cameras are supplied either with the 4mm or 8mm lens. V d The auto-iris lenses are recommended when the camera is used in environments with variable light conditions (eg. outdoors). By means of the auto-iris the amount of light going through the lens is regulated. The auto-iris is DC-controlled through a 4-pole connector at the back of the camera (). Horizontal field of view in meters (V) 10 8 6 4 0 0 4 6 8 Distance object to camera in meters (d) 4 mm 8 mm 10 Focal length of the lens CL 66610005_08A.AI 9

The pin connections of the auto-iris connector are: pin 1 = control coil - pin = control coil + pin = drive coil - pin 4 = drive coil + All lenses have the same light sensitivity. 4 1 CL 66610005_09.AI 10

Changing a lens Perform the following steps to change a lens: Point the camera downwards. This to minimize possible deposit of dust on the inside of the camera when the lens is removed. Remove the old lens by turning it counter-clockwise (1). Do not release the back-focus locking ring (), otherwise you may have to readjust the back-focus of the camera. Caution: Never touch the CCD sensor which is located at the inside of the camera. Only use clean, dry air to blow particles from the surface of the sensor. Mount the new lens by turning it clockwise onto the lens mount of the camera. 1 FAR < > NEAR CL 66610005_1.AI 1 6 4 FAR < > NEAR 5 CL 66610005_1.AI Direct the camera at the object or area to be monitored (6). Tighten the knob () and screw (4) when the camera is in position. Adjust the focus ring (1) of the camera lens to obtain an optimal image sharpness. Remark: If an auto-iris lens is used, connect the auto-iris cable to the camera (5). 11

System cable For the interconnections between the system monitor and camera 5m/75ft system cable is supplied. For an optimum picture and sound quality you should always use 4-wire dual twisted-pair cable when extending the connection. The max. allowed cable length is 00m/900ft. The cable and plugs are available in the hobby and professional trade. Pay attention that the connectors are fixed to the cable corresponding to the figure. 45 4 5 4-5 - 45 4 5-4-5 CL 66610005_006.AI If the cable length between the monitor and camera is more than 00m/600ft a mains power adapter should be used (see accessories). Caution: The plugs used for the observation system have the same dimensions as standard telephone plugs. Never connect a telephone to the camera or system monitor. Tips for maintenance Cleaning You can clean the outside of the camera with a moist fluff-free cloth or shammy leather cloth. When cleaning the camera lens a special cleaning cloth should be used. Do NOT use cleaning fluids based on alcohol, methylated spirit, ammonia, etc.. Never touch the glass of the camera lens to prevent its delicate coating from damaging. Avoid direct contact with water. 1

Technical specifications (VCM7177/00T / VCM7178/00T) Pick-up element 1/" solid state CCD Pixel elements 51 (H) x 58 (V), PAL interlaced Resolution 0 TVL Gain control automatic, 0dB Lens See: Using a different lens Iris Electronic iris When connected, an auto-iris lens overrides the electronic iris. Light sensitivity 0.4 lux minimally acceptable picture with standard lens (F1.) at 00K, transmission 86%, scene reflection 100%.0 lux, 50ire (-6dB) with standard lens (F1.) at 00K, transmission 86%, scene reflection 100% Scene illumination Not for continuous use above k lux with standard lens (F1.) For outdoor use an auto-iris lens is recommended. Signal to noise ratio 48dB at 00-5000 lux, 5 C White balance TTL range 500-6500K System connector (output) audio: common mode 500mVpp video: differential mode 175mVpp with pre-emphasis of 1dB at 5MHz. In the dual twisted pair system cable one pair carries the audio signal and the videosignal, the other the power supply and the synchronisation pulses. Microphone Built-in, can be switched off at the camera. Frequency range 00-000Hz Synchronisation The camera automatically synchronises to the system monitor. Without system monitor the camera generates its own synchronisation signals. Power supply 4V DC, when the system-cable length exceeds 00m/600ft a poweradapter(4v DC, current limit 500mA)isrequired(availableasaccessory) Power consumption W System-cable length max. 00m/900ft (when a mains power adaptor is used) Dimensions 7,5 (H) x 70 (W) x 60 (D) mm (excl. lens) Weight 190g Connectors System cable RJ11E modular ( telephone plug) External power Power jack Auto-iris control 4-pole socket Mounting 1/4" 0 UNC Ambient temperature Operating -10 to +50 C Storage -5 to +70 C Ambient humidity Operating 0 to 90% RH Storage up to 99% RH Specifications may change without notice. 14