HA Certification Document Dell PowerEdge R720 07/24/2013. Open-E High Availability Certification report for Dell PowerEdge R720

Similar documents
Open-E High Availability Certification report for Intel Server System R2224GZ4GC4

HA Certification Document Happyware HW-OPE2123-R1 07/04/2013. Open-E High Availability Certification report for Happyware HW-OPE2123-R1

HA Certification Document Broadberry CyberStore 424S 05/17/2013. Open-E High Availability Certification report for Broadberry CyberStore 424S

HA Certification Document TAROX ParX R208s G5 03/26/2014. Open-E High Availability Certification report for TAROX ParX R208s G5

Certification Document HP Proliant DL380 G7 12/22/2011. HP Proliant DL380 G7 storage system

Certification Document Supermicro SSG-6027R-E1R12T 04/30/2014. Supermicro SSG-6027R-E1R12T system

Certification Document macle GmbH IBM System xx3650 M4 03/06/2014. macle GmbH IBM System x3650 M4

Certification Document Starline NASdeluxe NDL-4224R/L 06/24/2015. Starline Computer GmbH NASdeluxe NDL-4224R/L Storage system

Certification Document GRAFENTHAL GmbH R2208 S2 01/04/2016. GRAFENTHAL GmbH R2208 S2 Storage system

Certification Document Rackserver Open-E Unified Storage 15 TB O2212iR 06/04/2014. Rackserver Open-E Unified Storage 15 TB O2212iR system

Lenovo RD240 storage system

10Gb iscsi Initiators

Intel SR2612UR storage system

Q500-P20 performance report

iscsi STORAGE ARRAYS: AND DATABASE PERFORMANCE

VMware VMmark V1.1 Results

Intel On-site Repair for Servers

Number of Hosts: 2 Uniform Hosts [yes/no]: yes Total sockets/core/threads in test: 4/24/48

NICs (dedicated for iscsi): NIC Driver version

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays

SanDisk Enterprise Solid State Drives: Providing Cost-Effective Performance Increases for Microsoft SQL Server Database Deployments

Dell with Oracle Database 11g R2 on Oracle VM Server 3.2

Use of the Internet SCSI (iscsi) protocol

Accelerate Applications Using EqualLogic Arrays with directcache

Accelerating storage performance in the PowerEdge FX2 converged architecture modular chassis

CA AppLogic and Dell PowerEdge R620 Equipment Validation

CA AppLogic and Dell PowerEdge R820 Equipment Validation

Number of Hosts: 2 Uniform Hosts [yes/no]: yes Total sockets/core/threads in test: 4/64/64

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage

View Turnkey Appliances (Rapid Desktop Appliances) Guide Last Updated: January 6, 2018 For more information go to vmware.com.

Dell with Oracle Database 11g R2 on RHEL 6.3 & Oracle Linux 6.3 with Compatible Kernel

VMmark 3.0 Results. Number of Hosts: 2 Uniform Hosts [yes/no]: yes Total sockets/cores/threads in test: 4/112/224

View Turnkey Appliances (Rapid Desktop Appliances) Guide Last Updated: May 11, 2018 For more information go to vmware.com.

Ingo Brenckmann Jochen Kirsten Storage Technology Strategists SAS EMEA Copyright 2003, SAS Institute Inc. All rights reserved.

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

Dell TM with Oracle Database Enterprise Edition Running Windows Server 2008

Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces

Performance Characterization of the Dell Flexible Computing On-Demand Desktop Streaming Solution

CA AppLogic and Dell PowerEdge R420 Equipment Validation

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Step-by-Step Guide to Synchronous Volume Replication (Block Based) with multipath Active-Passive iscsi Failover supported by Open-E DSS V7

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4

Configuration Section Configuration

Reduce Costs & Increase Oracle Database OLTP Workload Service Levels:

Performance Comparisons of Dell PowerEdge Servers with SQL Server 2000 Service Pack 4 Enterprise Product Group (EPG)

eslim SV Xeon 2U Server

NEC Express5800/B120f-h System Configuration Guide

Milestone Certified Solution

NEC Express5800/B120e-h System Configuration Guide

Components Vendor Model Number Part Number Result. LGA 1366 Processor Vendor Model Number Part Number Result GT/s Intel QPI, 6C / 12T, 130W

Dell EMC SAP HANA Appliance Backup and Restore Performance with Dell EMC Data Domain

High Performance Computing

Microsoft SQL Server 2012 Fast Track Reference Configuration Using PowerEdge R720 and EqualLogic PS6110XV Arrays

Deploying VMware View in the Enterprise EMC Celerra NS-120. Reference Architecture.

Dell PowerEdge R910 SQL OLTP Virtualization Study Measuring Performance and Power Improvements of New Intel Xeon E7 Processors and Low-Voltage Memory

10/08/2010 Please see the part number system chart on page 8 for all red X, Y, R and Z s. Page1

TEMPERATURE MANAGEMENT IN DATA CENTERS: WHY SOME (MIGHT) LIKE IT HOT

IT Business Management System Requirements Guide

Dell PowerVault MD1200 and PowerVault MD1220 Interoperability Guide

Deploying Microsoft SQL Server 2005 Standard Edition with SP2 using the Dell PowerVault MD3000i iscsi Storage Array

Video Surveillance Storage and Verint Nextiva NetApp Video Surveillance Storage Solution

VessR2000 Series SR1.3 Compatibility List

DELL Reference Configuration Microsoft SQL Server 2008 Fast Track Data Warehouse

eslim SV Opteron 1U Server

Reference Architecture

Minimum Hardware/Software Requirements (For details, see below)

HP Z Turbo Drive G2 PCIe SSD

Notes Section Notes for Workload. Configuration Section Configuration

IBM and HP 6-Gbps SAS RAID Controller Performance

Four-Socket Server Consolidation Using SQL Server 2008

VMware VMmark V1.1 Results

Demartek September Intel 10GbE Adapter Performance Evaluation for FCoE and iscsi. Introduction. Evaluation Environment. Evaluation Summary

A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510

Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740

StorPool System Requirements


Version 1.0 October Reduce CPU Utilization by 10GbE CNA with Hardware iscsi Offload

eslim SV Xeon 1U Server

NEC Express5800/B110d Configuration Guide

NEC Express5800/B120d-h System Configuration Guide

Dell PowerVault MD3000i 5000 Mailbox Single Copy Cluster Microsoft Exchange 2007 Storage Solution

BLADE SERVER DATABASE PERFORMANCE: DELL POWEREDGE M420

Dell PowerVault MD3000i Support Matrix

Synology Alex Wang CEO, Synology America

EMC CLARiiON CX3 Series FCP

TEST REPORT. SEPTEMBER 2007 Linpack performance on Red Hat Enterprise Linux 5.1 and 3 AS Intel-based servers

Aster Database Platform/OS Support Matrix, version 5.0.2

Avigilon Control Center System Integration Guide

Highpoint Takes On Adaptec's SAS Controller

How Verify System Platform Max. Performance

Hardware & Software Specification i2itracks/popiq

VMware VMmark V1.1 Results

vstart 50 VMware vsphere Solution Specification

Milestone Systems CERTIFICATION TEST REPORT Version /08/17

Microsoft SharePoint Server 2010 on Dell Systems

AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide

Dell PowerEdge with Oracle Database 10g x86-64 and RAC on Enterprise Linux AS 5 U2 version 4.1 Updated 01/30/2009

ReadyNAS OS 6 Desktop & Rackmount Performance

IBM eserver xseries. BladeCenter. Arie Berkovitch eserver Territory Manager IBM Corporation

Performance Characteristics on Gigabit networks

Transcription:

Open-E High Availability Certification report for 1

Executive summary After successfully passing all the required tests, the is now officially declared as Open-E High Availability Certified Storage Server. The tests, conducted by Open-E s Quality Assurance team, prove that Open-E High Availability solution works effectively and efficiently on the certified system. The certification also signifies to customers that the has met specific Open-E integration and interoperability standards. The Open-E High Availability solution, based on the, is considered to be stable and secure with superb performance. Certification notes The has been certified according to Open-E High Availability Certified Hardware Guide v. 1.0. 2

High Availability solution hardware components... 4 Auxiliary systems hardware components... 5 High Availability solution performance... 7 High Availability solution performance test topology... 7 Active-Passive iscsi Failover data throughput performance test... 8 Active-Active iscsi Failover data throughput performance test... 9 Active-Passive iscsi Failover resource group switching time test... 10 Active-Active iscsi Failover resource group switching time test... 11 High Availability solution functionality... 12 High Availability solution functionality test topology... 12 High Availability solution functionality test... 13 3

High Availability solution hardware components Technical specification of iscsi Failover nodes is listed below: Model Operating system Open-E DSS V7 build 7356 Enclosure/chassis CPU 2x Intel Xeon E5-2640 2.50 GHz Motherboard Dell Power Edge R720 (based on Intel C600) Memory 4x 8GB DDR3 ECC-REG Hynix HMT31GR7BFR4A-H9 Broadcom NetXtreme II BCM57711 Dual-Port 10 GbE Broadcom 5720 Quad-Port 1GbE HW RAID Dell PERC H710 Integrated Hard disk drives 16x 146GB Seagate Savvio 15K.2 ST9146852SS TABLE 1: Hardware components list of iscsi Failover nodes Both iscsi Failover nodes have the same hardware configuration as listed above. 4

Auxiliary systems hardware components Auxiliary systems with MS Windows installed, used in Open-E High Available solution Hardware Certification Process. Model Operating system Enclosure/chassis MS Windows Server 2008 R2 Motherboard Dell Power Edge R720 (based on Intel C600) CPU Memory HW RAID Hard disk drives Intel Xeon E5-2640 2.50 GHz 4x 8GB DDR3 ECC-REG Hynix HMT31GR7BFR4A-H9 Broadcom NetXtreme II BCM57711 Dual-Port 10GbE Broadcom 5720 Quad-Port 1GbE PERC H710 Integrated 2x 146GB Seagate Savvio 15K.2 ST9146852SS TABLE 2: Hardware components of first Workstations with MS Windows Model Operating system MS Windows Server 2008 R2 Enclosure/chassis Motherboard Dell Power Edge R720 (based on Intel C600) CPU Intel Xeon E5-2640 2.50 GHz Memory 4x 8GB DDR3 ECC-REG Hynix HMT31GR7BFR4A-H9 Broadcom NetXtreme II BCM57711 Dual-Port 10GbE Broadcom 5720 Quad-Port 1GbE HW RAID PERC H710 Integrated Hard disk drives 2x 146GB Seagate Savvio 15K.2 ST9146852SS TABLE 3: Hardware components of second Workstations with MS Windows Model Dell PowerEdge R620 Operating system MS Windows Server 2008 R2 Enclosure/chassis Dell PowerEdge R620 CPU Intel Xeon E5-2640 2.50 GHz Motherboard Dell PowerEdge R620 (based on Intel C600) Memory 4x 8GB DDR3 ECC-REG Samsung M393B1K70CH0-CH9 Broadcom 5720 Quad-Port 1GbE HW RAID PERC H710 Integrated Hard disk drives 4x 300GB Hitachi Ultrastar C10K600 HUC106030CSS600 TABLE 4: Hardware components of third Workstations with MS Windows 5

Model Dell PowerEdge R620 Operating system MS Windows Server 2008 R2 Enclosure/chassis Dell PowerEdge R620 CPU Intel Xeon E5-2640 2.50 GHz Motherboard Dell PowerEdge R620 (based on Intel C600) Memory 4x 8GB DDR3 ECC-REG Samsung M393B1K70CH0-CH9 Broadcom 5720 Quad-Port 1GbE HW RAID PERC H710 Integrated Hard disk drives 4x 300GB Hitachi Ultrastar C10K600 HUC106030CSS600 TABLE 5: Hardware components of fourth Workstations with MS Windows Model Dell PowerConnect 6224 Description 24-ports 1GbE managed switch TABLE 6: switches details Both switches used for performing certification tests are of the same type as listed above. 6

High Availability solution performance Tests performed in this section compare the performance of Active-Passive iscsi Failover with Active-Active iscsi Failover available in the Open-E DSS V7 software running on the certified systems. High Availability solution performance test topology topology for High Availability solution performance testing is shown below. FIGURE 1: topology for High Availability performance testing 7

Block size [KB] HA Certification Document 07/24/2013 Active-Passive iscsi Failover data throughput performance test 1. Test description The test relies on using the iscsi targets exported by Active-Passive iscsi Failover running on certified systems. The data are copied from four Workstations with MS Windows equipped with two 1GbE interfaces each to iscsi targets located on one active node using the Iometer tool. One 10GbE interface is used on each node for Volume replication. 2. Test results for Active-Passive iscsi Failover data throughput performance using Broadcom 5720 Quad-Port 1GbE on one active node Block size [KB] Active-Passive iscsi Failover data throughput performance test results Total write throughput [MB/s] Total read throughput [MB/s] Performance test results 4 95.58 133.43 passed 32 221.41 305.81 passed 64 257.03 393.83 passed 128 357.57 440.05 passed 256 389.09 451.47 passed 512 415.79 464.34 passed 1024 424.49 473.36 passed 4096 438.59 468.82 passed TABLE 7: Active-Passive iscsi Failover data throughput performance test results table for Broadcom 5720 Quad-Port 1GbE on one active node 4 32 64 128 256 512 1024 4096 Total write throughput [MB/s] Total read throughput [MB/s] 0 200 400 600 800 1000 FIGURE 2: Active-Passive iscsi Failover data throughput performance test results chart for Broadcom 5720 Quad-Port 1GbE on one active node 8

Block size [KB] HA Certification Document 07/24/2013 Active-Active iscsi Failover data throughput performance test 1. Test description The test relies on using the iscsi targets exported by Active-Active iscsi Failover running on certified systems. The data are copied from four Workstations with MS Windows equipped with two 1GbE interfaces each to iscsi targets located on two active nodes using the Iometer tool. One 10GbE interface is used on each node for Volume replication. 2. Test results for Active-Active iscsi Failover data throughput performance using Broadcom 5720 Quad-Port 1GbE on both active nodes Block size [KB] Active-Active iscsi Failover data throughput performance test results Total write throughput [MB/s] Total read throughput [MB/s] Performance test results 4 124.32 185.23 passed 32 471.61 643.47 passed 64 556.95 783.03 passed 128 776.81 865.52 passed 256 816.71 880.39 passed 512 853.85 896.08 passed 1024 855.81 895.43 passed 4096 855.28 891.20 passed TABLE 8: Active-Active iscsi Failover data throughput performance test results table for Broadcom 5720 Quad-Port 1GbE on both active nodes 4 32 64 128 256 512 1024 4096 0 200 400 600 800 1000 Total write throughput [MB/s] Total read throughput [MB/s] FIGURE 3: Active-Active iscsi Failover data throughput performance test results chart for Broadcom 5720 Quad-Port 1GbE on both active nodes 9

Number of targets HA Certification Document 07/24/2013 Active-Passive iscsi Failover resource group switching time test 1. Test description The test relies on copying data of 4MB block size using the Iometer tool from four Workstations with MS Windows equipped with two 1GbE interfaces each to iscsi targets located on one active node. The Resource group switching time is measured under high load for 2, 10 and 20 iscsi targets located on one active node. One 10GbE interface is used on each node for Volume replication. 2. Test results for Active-Passive iscsi Failover resource group switching time using Broadcom 5720 Quad-Port 1GbE on both active nodes Active-Passive iscsi Failover resource switching time test results Total number of targets Switching time [seconds] Performance test results 2 1 passed 10 2 passed 20 4 passed TABLE 9: Active-Passive iscsi Failover resource group switching time test results table for Broadcom 5720 Quad-Port 1GbE on one active node 2 10 20 Switching time [seconds] 0 1 2 3 4 5 FIGURE 4: Active-Passive iscsi Failover resource group switching time test chart for Broadcom 5720 Quad-Port 1GbE on one active node 10

Number of targets HA Certification Document 07/24/2013 Active-Active iscsi Failover resource group switching time test 1. Test description The test relies on copying data of 4MB block size using the Iometer tool from four Workstations with MS Windows equipped with two 1GbE interfaces each to iscsi targets located on two active nodes. The Resource group switching time is measured under high load for 2, 10 and 20 iscsi targets located on two active nodes. One 10GbE interface is used on each node for Volume replication. 2. Test results for Active-Active iscsi Failover resource groups switching time using Broadcom 5720 Quad-Port 1GbE on both active nodes Active-Active iscsi Failover resource switching time test results Total number of targets Switching time [seconds] Performance test results 2 1 passed 10 1 passed 20 2 passed TABLE 10: Active-Active iscsi Failover resource groups switching time test results table for Broadcom 5720 Quad-Port 1GbE on both active nodes 2 10 20 Switching time [seconds] 0 1 2 3 4 5 FIGURE 5: Active-Active iscsi Failover resource groups switching time test chart for Broadcom 5720 Quad-Port 1GbE on both active nodes 11

High Availability solution functionality Tests performed in this section analyze the functionality of High Availability solution configured as Active-Active iscsi Failover, available in the Open-E DSS V7 product on the certified systems. High Availability solution functionality test topology topology for High Availability solution functionality testing is presented below. FIGURE 6: topology for High Availability solution functionality testing 12

High Availability solution functionality test 1. Test description The test relies on performing various actions which should cause Resource group switching during copying data from four Workstations with MS Windows equipped with two 1GbE interfaces each to iscsi targets exported by Active-Active iscsi Failover. It tests whether failover occurs and if all resources are still reachable for 20 iscsi targets located on two active nodes. One 10GbE interface is used on each node for Volume replication. 2. Test results for High Availability solution functionality Total number of targets High Availability solution functionality test Test case Test results 20 Manual resources transfer test passed 20 malfunction test passed 20 Reboot test passed 20 Shutdown test passed 20 I/O error test passed TABLE 11: High Availability solution functionality test results table 13