Addonics T E C H N O L O G I E S

Similar documents
Addonics T E C H N O L O G I E S. Addonics iscsi Subsystem. Model: ISC8P2G

Addonics T E C H N O L O G I E S. Jupiter Mobile Rack AJMRI, AJMRSA. User s Guide Version 1.0

Addonics T E C H N O L O G I E S. Storage Tower Overview. Storage Tower

Addonics. Serial ATA/RAID Controller. Users Guide Revision 1.0

Addonics T E C H N O L O G I E S. Portable Dual Drive RAID Enclosure. Model: AE25RDESU. Enclosure Overview. RAID Setting button

Addonics. Combo RAID System. Users Guide Revision 1.0

Addonics T E C H N O L O G I E S. mini NAS. Model: NAS25HDU Key Features

Addonics T E C H N O L O G I E S

Addonics T E C H N O L O G I E S

RocketRAID 2760A. 6Gb/s SAS/SATA Host Adapter. Quick Instal l ation Guide v1.1

Addonics. Saturn Cipher Drive Cartridge System(SCDCS) T E C H N O L O G I E S. For the following Models:

Addonics T E C H N O L O G I E S

Addonics. Combo Hard Drive USIB25 Mobile Rack USIB25

Addonics. SATA 4-port RAID controller (ADST114) Users Guide Revision 1.0

RocketRAID 272x/271x Host Adapter

Addonics T E C H N O L O G I E S

Addonics T E C H N O L O G I E S

Addonics. 4-Port SATA II PCI RAID5/JBOD Controller Card (ADSA4R5) User s Guide Revision 1.0 T E C H N O L O G I E S

Addonics. 4X SATA Multilane PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-ML) User s Guide Revision 1.1 T E C H N O L O G I E S

Addonics T E C H N O L O G I E S

Addonics T E C H N O L O G I E S

Addonics TECHNOLOGIES

Addonics. Pocket UDD (Ultra DigiDrive) Users Guide Revision 1.0. USB Firewire T E C H N O L O G I E S

Addonics TECHNOLOGIES. Pocket DVD For Cardbus, USB & Firewire

Hardware Installation 1. Install two AA batteries in the mouse. Pairing Process in Vista and Windows XP SP2

Addonics T E C H N O L O G I E S

Addonics TECHNOLOGIES. Mobile DVD/CDRW Firewire CardBus/PCMCIA USB. Users Guide Revision 2.0. For PC

RocketU 1022C Host Controller

RocketCache 32xx Series HBA

Addonics T E C H N O L O G I E S

RocketRAID 644L / 642L. 6Gb/s esata PCI-Express 2.0 RAID HBA

Rocket 272x 6Gb/s SAS/SATA Host Adapter Quick Installation Guide

RocketRAID 3622/3620. SATA 6Gb/s PCI-Express 2.0 x 8 RAID HBA

RocketU 114xE Host Controller

Bluetooth Micro Dongle User s Guide. Rating: 5V DC 80mA Made in China

RocketStor Dual-Bay Thunderbolt TM 10Gb/s Storage Dock

User Guide of AU-4612

Rocket Dual esata 6Gb/s For Mac

RocketU 1144CM 4-Port USB 3.0 PCI-Express 2.0 x4 RAID HBA

SAS JBOD Installation Reference Guide Revision 1.0

RANGER SERIES. 150Mbps Wireless Green Broadband Router DG-BR4000NG. 150 Mbps V

WHG425 V3.20. Secure WLAN Controller

WHG201 V1.00. Secure WLAN Controller

RocketRAID 2720C2. User Manual V1.00

IEEE 1394 PC-Card Interface Adapter

H560N. Quick Start Guide

WHG405 V2.10. Secure WLAN Controller

Rocket 640L/644L 6Gb/s SATA Host Adapter Quick Installation Guide

USER MANUAL USB Bluetooth Adapter

1. Package contents. 2. Connecting ADSL modem and wireless router

External JBOD 220 (EJ220)

Quick Installation Guide

ATRx Biometric Package Contents: Minimum System Requirements: INSTALLATION GUIDE BIOMETRIC HANDPUNCH TECHNOLOGY

Addonics Technologies. ExDrive. User Guide. Revision 2.7

Intelligent Wireless Router. Quick Installation Guide

Instruction Guide. 2 Channel Ultra ATA/100 PCI Card PCI2IDE100. The Professionals Source For Hard-to-Find Computer Parts. Revised: December 5, 2002

RocketRAID esata For Mac HighPoint Technologies, Inc.

EL-IP-OBF2-WH / EL-IP-OBV2-WH EL-IP-OBF4-WH / EL-IP-OBV4-WH. Quick Start Guide

SKYROS SERIES Megapixel Outdoor Bullet PoE IP Camera with IR LED and IR-cut Filter DG-SC5800PI

EL-IP-IDF2-WH / EL-IP-IDV2-WH EL-IP-IDF4-WH / EL-IP-IDV4-WH. Quick Start Guide

RocketStor 5315 Quick Installation Guide V1.0 Jan. 4, 2013

DRIVE DOCK. User Guide

ZigBee Server USER GUIDE

4800B Series PC Card Wireless LAN Adapter Quick-Start Guide

RocketU 1144D/1142A Quick Installation Guide V1.00

Quick Installation Guide

WebRamp M3 Quick Start. for Windows and Macintosh

HD-PGDU3. User Manual

EL-IP-ODF2-WH / EL-IP-ODV2-WH EL-IP-ODF4-WH / EL-IP-ODV4-WH. Quick Start Guide

DRIVE DOCK. User Guide

WHG311 V1.03. Secure WLAN Controller

PCMCIA Fast Ethernet PC Card

LabelWriter. Print Server. User Guide

3.5 External Hard Drive Enclosure

Quick Install Guide. XGS Port Gigabit Ethernet Switch. luxul.com. Simply Connected. Use the XGS-1024 to:

USB Hub-Audio Series. January 1999 A

USER MANUAL FOR MF0200 GATEWAY BOX VERSION 2.0

DRIVE DOCK. User Guide

HomePlug Ethernet Bridge

FlyTV MCE Installation Guide Animation Technologies Inc.

IEEE g Wireless PC Card. User s Guide

USER S MANUAL. QS2 USB2.0 QS2 USB2.0/eSATA Combo and QS2 USB2.0/eSATA/Firewire Combo Models

Contents Introduction to the Product Configuration CPE built-in Web Server Access CPE Setup on the web page Trouble Shooting Operating Information

IP Camera KK002 Quick Start Guide

N331 Wireless Mini Optical Mouse User s Guide

ViewXnet. Ethernet to DVI/VGA adapter USER S MANUAL

100BASE-TX/10-B REX-CB81U. User Guide. November 1998 First Edition

802MR. User s Manual

Installation Guide AHA Micro Channel-to-SCSI Host Adapter

DATALOCKER H100 ENCRYPTED HARD DRIVE. User Guide

USER S MANUAL USB TO Serial Adapter

NSM Plug-In Users Guide

CardBus 10/100 Fast Ethernet PC Card UE1205CB. Instruction Guide. The Professionals Source For Hard-to-Find Computer Parts. Revised: July 24, 2002

PnP IP/Network Camera

3.5 inch Hard Drive Enclosure. Model #: HDE350U. User s Manual

3.5 inch Hard Drive Enclosure. User s Manual

Outdoor Wireless USB Adapter User Guide

EN-9260TX-E User Manual

Quick Installation Guide

WiFi-Repeater User Manual. Quick Installation Guide(Q.I.G.) REV.1.2

Transcription:

Note: For more detailed information on the Addonics ISC16P2G-S iscsi Subsystem, refer to the User Manual on the CD. You can also visit our website www.addonics.com Addonics T E C H N O L O G I E S Overview This Quick Install guide provides information on how to create an iscsi drive on the Addonics ISC16P2G-S iscsi Subsystem and how to connect to the drive using Microsoft iscsi Initiator. Addonics iscsi Subsystem Model: ISC16P2G-S LCM (LCD Control Module) Display Quick Install Guide Front View Rear View FCC Warning Statement LAN 2 Data port LAN 1 Data port This equipment has been tested and found to comply with the limits for a class B digital device pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try and correct the interference by one or more of the following suggestions. Reorient or relocate the receiving antenna Increase the distance between the equipment and the receiver Connect the equipment to a different power outlet other than the one where receiver is connected Consult a certified television or radio technician 4-Port Molex power connector Web GUI IP port

Top View ISC16P2G-S Mounted on the Storage Tower & Storage Tower II ISC16P2G-S ISC16P2G-S DDR II Slot SATA ports 4 3 2 1 8 7 6 5 10 11 12 9 ISC16P2G-S Mounted on the Storage Rack SATA ports 16 15 14 13 LAN Cable Connections on the Storage Tower ISC16P2G-S Web GUI IP port LAN 1 Data port LAN 2 Data port LAN Cable Connections on the Storage Rack Web GUI IP port ISC16P2G-S Mounted on the Storage Tower II LAN 1 Data port Web GUI IP port LAN 1 Data port LAN 2 Data port LAN 2 Data port

Getting started Before starting, prepare the following items. 1. A server or workstation with a NIC or iscsi HBA. 2. CAT 5e, or CAT 6 network cables for web GUI port and iscsi data ports. We recommend CAT 6 cables for best performance. 3. Gigabit LAN switches. 4. Setup the hardware connection of the ISC16P2G-S before powering up servers and ISC16P2G-S. Connect the web GUI port cable, and ISC16P2G-S data port cables first. Login In the web browser, type the IP address shown on the LCM display. Function block LCM (LCD Control Module) Display After booting up the ISC16P2G-S iscsi subsystem, the LCM display shows web GUI port IP and model name: 192.168.1.50 Addonics ISC16P2G-S Place the cursor on any function block located on the left side of the window then do a right click, an authentication window opens up. Web GUI Management Managing the Addonics iscsi subsystem ISC16P2G-S is describe in the following: The ISC16P2G-S supports Graphic User Interface (GUI) as a management method. The default setting for the web GUI port IP is DHCP and the DHCP address is displayed on the LCM. You can check the LCM for the Web GUI IP address first, then open the browser and type the DHCP address: (The DHCP address is dynamic and user may need to check every time after reboot again.) E.g., on LCM. 192.168.1.50 Addonics ISC16P2G-S User name: admin Password: supervisor After login, you can choose the Quick Install function block on the left side of window to do configuration. Figure 1.0

There are four indicators at the top-right corner of the web GUI. Step 1: Click Quick installation, then choose the RAID level. After choosing the RAID level, then click page.. It will link to another Figure 1.1 1. RAID light: Green LED means RAID works well. Red LED represents RAID failure. 2. Temperature light: Green LED is normal. Red LED represents abnormal temperature. Step 2: Click Figure 3.3.1 to use default algorithm. Formatted 3. Voltage light: Green LED is normal. Red LED represents abnormal voltage status. 4. UPS light: Green LED is normal. Red LED represents abnormal UPS status. Step 3: Click to select the default volume size. Quick install The Quick install function is used to create a volume. The ISC16P2G-S Quick Install function has a smart policy. When the system is full, meaning all 8 HDD are connected, and all HDD have the same size, ISC16P2G-S Quick Install function lists all possible configurations and sizes among different RAID level options. The ISC16P2G-S Quick Install will use all available HDD for the RAID level which the user decides. But when the system is inserted with different sizes of HDD, e.g., 6*200G HDD and 2*80G, ISC16P2G-S also lists all possible combinations of different RAID Level and different sizes and you may observe there are some HDD not used (Free Status). Step 4: Confirm page. Click correct. Then a VD will be created. Done. You can start to use the system now. if all setups are Figure 3.3.2 Formatted (Figure 3.3.2: A RAID 0 Virtual disk with the VD name QUICK83716, named by system itself, with the total available volume size 297GB.)

iscsi Initiator (Software) OS Software/Release Number Note: The Link needs to be Up Microsoft Windows Microsoft iscsi Software Initiator Release v2.07 For the OS, below you need to download the iscsi initiator from Microsoft website. 1. Windows XP Professional with SP2 2. Windows 2000 Server with SP4 3. Windows Server 2003 with SP1 4. Windows Server 2003 R2 Step 2: Install Microsoft iscsi Initiator Steps to setup Microsoft iscsi Initiator. Visit Microsoft website for latest iscsi initiator. System Requirements: Windows Vista comes with the iscsi initiator preinstalled. http://www.microsoft.com/downloads/details.aspx?familyid=12cb3c1a-15d6-4585-b385-befd1319f825&displaylang=en 1. Run the iscsi executable file. The Software Update Installation Wizard opens. Click Next Microsoft iscsi Initiator Step 1: Determine iscsi data port IP address or DNS name of ISC16P2G-S iscsi subsystem Before using the Microsoft iscsi Initiator, you need to determine first the iscsi data port IP address or DNS name of ISC16P2G-S iscsi subsystem. The following steps will help you determine the IP address. From the function block in the Web GUI, select iscsi config. Its submenu is shown in Figure 1.4 iscsi config is used for setting up Entity Property, NIC, Node, Session, and CHAP account. 2. Click Next. Figure 1.4 Select NIC to view IP addresses of ISC16P2G-S iscsi subsystem data ports. The ISC16P2G-S have two data ports.

3. Select I Agree and click Next. 4. Click Finish. 2. Click Discovery tab. Step 3: Running the Windows iscsi Initiator 1. Run Microsoft iscsi Initiator version 2.08 icon from the desktop. The iscsi Initiator Properties window opens.

3. Click Add. Input IP address or DNS name of ISC16P2G-S iscsi subsystem. 6. Click Log On. 4. Click OK. 7. Click OK. The status would be Connected. 5. Click Targets. 8. The iscsi disk will show up in Disk Management. ISCSI drive

The following procedure shows how to log off the iscsi drive. 1. In the Targets tab, click Details. The Target Properties window Technical Support If you need assistance to get your unit functioning properly, please call Addonics Technical Support. Our technical staff will be happy to assist you, but they will need your help to do so. Calling the technical support staff without all the proper information can be both time consuming and frustrating. Here are some tips to help you out: MODEL NUMBER Please have this number on hand. SYSTEM INFORMATION Type of computer, peripherals, etc. OPERATING SYSTEM What version of Windows WHAT S THE TROUBLE? Give enough information about your problem so that we can recreate and diagnose it. FREE Software Drivers for all Addonics Technologies Products are available 24 hours per day at the World Wide Web Site: www.addonics.com Contact Information Phone: 408-573-8580 Fax: 408-573-8588 Email: http://www.addonics.com/sales/query/ Internet: http://www.addonics.com TECHNICAL SUPPORT Phone: 408-453-6212 Hours: 8:30 am - 6:00 pm PST Email: http://www.addonics.com/support/query/ 2. Check the radio button under Identifier. Click Log off. 3. This will log off the iscsi drive.