CF-4210Z/4220Z. Personal FFT Analyzers

Similar documents
Measurement microphone. MI series

Integrating Sound Level Meters LA-5570/5560/2560

Integrating Sound Level Meter. LA-4440 (Class 1) LA-1410 (Class 2) /LA-1440 (Class 2)

Meters LA-1000/4000 series

Multichannel Data Station DS series. [Standard measurement unit for sound and vibration]

ONO SOKKI-OVERSEAS COMPANY PROFILE

Dynamic & High-Resolution

VIBRATION COMPARATOR. VC-2200 / 3200 Series VC-2200 VC-3200

Sound Level Meter. LA-7000 series. Listen, measure, and identify the sound.

Practical and Compact!

DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope

DS-3000 Series Data Station Operation manual for Vibration Analysis

DS-0322 Tracking Analysis Software Operation manual Basic Operation procedure for Constant-ratio Tracking Analysis

Portable vibration calibrator Model 28959G

VIBRATION METERS VX-54WH. Hand-Arm Vibration VX-54WB. Whole-Body Vibration VX-54WS. Habitability on Ships. 3-Axis Vibration Meter VM-54

Vibration-Resistant Weighing Indicator

GDS-2000 Series. Features

Dynamic & High-Resolution

Vibration Tester. Test and Measurement Instruments C.C.

Innovation in Magnetic Measuring Instruments. Data Acquisition & Conditioning Units

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

Measure Sounds Reliably

F150-3 VISION SENSOR

GHI Systems Rotary Vibration Machine Manual

MachineryMate 200 operating guide Handheld vibration meter

WR1000 SERIES. Thermal Arraycorders. Color. Large-capacity. High-speed

" User s Manual. Adash 3900-II Online Vibration Monitoring System. Applications: Characteristics:

Portable and Online Condition Monitoring System

Digital Storage Oscilloscope

Heavy Duty Vibration Meter

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

Instruction Manual MINI CALIBRATOR MC-20

midi LOGGER 200 SERVICE MANUAL GL200-UM-251 GL200-UM

Data Acquisition & Signal Conditioning Units

Heavy Duty Vibration Meter

power quality Models 8230 & 8220

Electronic SD1, AS 8, ASR 14, ASR 20

Standard Model Digital Force Gauge ZTS series

DVC-8 Vibration Controller

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

System Interface Unit SIU-100/100T

DSP Control. 0.9 Output Power Factor. Wide Input Range. High Efficiency Mode(ECO) Frequency Converter Mode. Input THDi<5% Output THDv<2%

Variable Regulated DC Power Supplies PAD-LA Series

A3900 II Online Monitoring System

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG06

MG12XU Overview Features Technical Data Sheet

Optical Spectrum Analyzer AQ6330. Full featured optical spectrum analyzer with compact and lightweight design

CoCo-80X DYNAMIC SIGNAL ANALYZER

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

User's Guide. Vibration Meter and Laser Combination Tachometer Model

Aim of planning Feature & usability by type

Integrated Recorder GX-1

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console MG10. MG10 is a versatile mixer suitable for a wide range of users and applications.

Specifications. Models. Models EDX-200A-2H EDX-200A-2H-0 EDX-200A-2H-1 EDX-200A-4H EDX-200A-4H-0 EDX-200A-4H-1 EDX-200A-4T

High Functionality Model Digital Force Gauge ZTA series

TES-1358 INSTRUCTION MANUAL

One (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.

OFV-2500 Vibrometer Controllers

Note: Unit is set at the factory for 120V operation. Be sure to change the fuse (2A rating) before switching to 230V operation.

Pen Vibration Meter. User's Guide. Model VB Washington Street Melrose, MA Phone Toll Free

VIPEDIA-12. Cameo specification sheet. Product Description

Bus Bar Protection Relay B-PRO 4000

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Product RS stock no. Mitsubishi no. Description and features Display FX-40DU-E LCD display and function keys directly connected into FX PLC

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG03

LA-2111 LA-5111 and LA-5120 Sound Level Meter Measurement by 1/3 Real-time Octave Filter

Impact-Echo Instruments, LLC. Ithaca, New York. Field Instruments for Nondestructive Evaluation of Concrete & Masonry

Bearing (Shock Pulse) Condition Analyzer -110

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Highspeed. New inspection function F160. Simple operation. Features

ES Energy Saver Product Ranges 90Amp 6000Amp

Series Lineup. NL Sound Level Meter <Class 2> NL A New Generation of Sound Level Meters. Sound Level Meter <Class 1>

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Encoders IE Series. Magnetic Encoders 6,1 12, Features: 64 to 512 Lines per revolution 2 Channels Digital output

Flexible Test Setup 16 model types 10 operations, each can have a unique test setup

Vibration Meter and Laser Combination Tachometer

PZ4000 Product Tutorial. Product Tutorial

Swift Responses with Accurate Measurement

User friendly and easy to program

Note: Unit is set at the factory for 120V operation. Be sure to change the fuse. (2A rating) before switching to 230V operation.

Advanced Features. High Performance Stepper Drive Description. Self Test and Auto Setup

VR9500. Advantages Ease of Use. Features

X725 USB DAC & AMP. User s Manual

Ref. No " DUAL CD PLAYER, MIXER AND CASE USER MANUAL

Advanced Test Equipment Rentals ATEC (2832)

APM. User manual & Installation guide. Digital paging microphone.

INSTRUCTION MANUAL CALIBRATION EXCITER VE Higashimotomachi, Kokubunji, Tokyo , Japan

2U/5U. AC + DC Power Solutions. Transient Generation for Disturbance Tests. only. High Performance Programmable AC Power Source

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

LAUREL ELECTRONICS, INC.

FCC Statement. 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

ILS Presentation Systems Better for presenters, better for the audience

SI3300. user and installation manual. 4-20mA/DC-Digital Display

RT4F-110V/25A RECTIFIER

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

Portable FFT Analyzer Model CF-7200

Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys. For innovation in magnetic measuring instruments

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

CSI 6300 SIS Overview

Transcription:

Personal FFT Analyzers The jog/shuttle cursor, a wheel that combines the functions of a rotary knob and a shuttle cursor, provides easy menu window setup operation. The FFT analyzers can be used as OK/NG judgment machines on production lines simply by installing the comparator output card that is available as an option. The incorporation of a 6.4-inch LCD screen has enabled a considerable reduction in device weight (a reduction of 30% when compared with the previous models, CF-4210A/4220A).

Personal FFT Analyzers Lineup The and CF-4220Z are single-channel FFT analyzers that are equipped with a range of basic functions. There are two models available: the standard model and the more sophisticated CF-4220Z model that is provided with a microdot connector for direct sensor input and a floppy disk drive. The optional comparator function (CF-0460Z) enables the to be used as OK/NG judgment devices on production lines. Built-in 6.4-inch LCD screen Jog/shuttle cursor for easy on-site operation Standard type Light weight for easy carrying 1. 2. 3. 4. 5. 6. 7. 8. 16-bit A/D conversion, 85 db (typ) dynamic range 20 khz real-time analysis function (CF-0430) provided as standard. Note: The CF-0460Z option is required for points 3. to 8. above. CF-4220Z Direct sensor input, floppy disk drive provided as standard OK/NG judgment is performed with respect to the power spectrum, 1/1 and 1/3 octave calculation results. Up to a maximum of 16 blocks can be specified as the judgment area. The comparison judgment method can be selected from five types: level, maximum value, area percentage, segment overall value and peak level. The judgment results can be displayed on the LCD, or output using a relay contact. Six types of functions such as Start, Start Comparison Judgment, and so forth can be freely used for the contact input. NG data can be saved automatically to a floppy disk (CF-4220Z only).

Features The comparator function demonstrates its power on production line OK/NG judgment applications. The comparator function is available as an option (CF-0460Z). A judgment block is specified for the amplitude level, and then contact output used to perform OK/NG judgment of products on a production line. The reference parameter used by the comparator is the rectangle defined by the upper and lower frequency and level limits (hereinafter referred to as "block"). Judgment is performed with respect to this block. The maximum number of blocks that can be specified is 16. The judgment level can be specified as (1) Upper limit value only, (2) Lower limit value only or (3) Both upper and lower limit values. The block's peak value or partial overall value can be used to perform comparison judgment. With this judgment method, a judgment area block is specified on the power spectrum and one of five types of judgment methods selected for OK/NG judgment. Control can be performed via transmission through an RS-232C or other interface. A maximum of six types of relay contact input functions can be used, and control in combination with a sequencer can also be performed. The judgment results can be output via contact output to configure a system in combination with an inline tool such as a rotating warning light or alarm. Acceleration pickup NG OK Built-in contact input/output functions INPUT 1 2 3 4 5 6 COM OK CMP BBY The comparator function enables output of the OK/NG results. In addition, it can be used as an external remote control function. By registering GPIB commands to each of the six contact input terminals, external control can be performed of such functions as start/stop, changing of the judgment parameters, and so forth. Comparator setup window Why judgment using FFT analysis is required When evaluating product quality, it is not possible to judge phenomena such as sound frequency shifts and level variations, the effects on rotational frequency caused by motor eccentricity, or the variations in the tapping sound caused by the generation of cracks from the overall sound and vibration levels or from simply viewing the levels of specific frequency bands. For this type of evaluation, frequency analysis performed by an FFT analyzer is essential. If the models have been equipped with the CF-0460Z comparator function, a window specifying the frequency range and the upper and lower level limits can be set up (up to a maximum of 16 blocks can be specified for the judgment area) and the judgment method selected from the five types available: level, maximum value, area percentage, segment overall value and peak level.

Applications Crack inspection of flexible pads, castings, metal plates, etc. The tapping sound changes if there are any cracks present in homogeneous material. A microphone is used to measure the tapping sound. Frequency analysis is then performed and the results used to judge whether any cracks are present. MI-3110 Preamp MI series Microphone Hammer tap Motor OK/NG judgment The vibration frequency varies slightly if the motor shaft moves eccentrically or if an abnormality occurs. The spectrum area percentage with respect to the area defined by the specific frequency band and by its upper and lower limits is used for OK/NG judgment. Acceleration pickup CF-4220Z SR-2200 Note: An amplifier with a built-in acceleration pickup can be used for direct input. Judgment of mobile phone ring tones Spectrum harmonics are used for the OK/NG judgment of the sound quality and level of mobile phone ring tones. Estimation of the resonance frequency of components OK/NG judgment is performed from the power spectrum used for analysis when the components are shaken prior to assembly. External generator Anechoic box MI-3110 Preamp MI series Microphone SR-2200 Amp Shaker Judgment of turbine noise level The noise level generated by the turbo fan is held at peak-hold level. This level is then used for OK/NG judgment. Continuous monitoring of rotational fluctuations The rotational fluctuations that occur when film or paper is being wound onto a roll result in bad production lots. The amplitude value of the amount of rotational fluctuation is monitored continuously. Sound level meter FV-1300 Turbine plate Roller encoder RP-721

System configuration External control Program sequencer OK/NG Judgment display OK NG Input /output of judgment control Comparator card Option (CF-0460Z) Sound analysis Microphone: MI-1211/1233/1431 Microphone preamp: MI-3110 2-channel sensor amp: SR-2200 Sound level meter: LA Series Vibration analysis Acceleration pickup: NP-3000 series FDD (CF-4220Z) Vibration analysis Acceleration pickup: NP-2000 Series Specifications Direct sensor input (CF-4220Z) Model variations CF-4220Z (Direct sensor input function and floppy disk drive are provided.) Processing functions Time-axis waveform, power spectrum, phase spectrum, 15 band 1/3 octave, 5 band 1/1 octave Probability density function, probability distribution function Input section Number of input channels: 1 Input signal connectors: BNC connector (front and rear panels) Microdot connector (CF-4220Z only) Voltage range: ±10 mv to ±50 V, 12 ranges Dynamic range: 85 db (typ) Analysis-related specifications Frequency ranges: 1 Hz to 40 khz, 19 ranges, and Zoom (CF-0431) Number of sampling points: 1024 A/D resolution: 16-bit Frequency resolution: 1/400 of the frequency range Real-time analysis: 20 khz standard (CF-0430) Trigger section Trigger modes: Free, repeat, single, one-shot Trigger source: Internal or external Trigger position: Specifiable in one-point increments within the range of -1024 to 1023 points Trigger level: Specifiable in ±1% increments with respect to full scale of the voltage range Secondary processing calculation functions Frequency axis differential/integral function, power spectrum density, partial overall, arithmetic calculation using memory waveforms Averaging processing Averaging modes Time axis waveform: Summation averaging Power spectrum: Summation averaging, exponential averaging, peak hold Phase spectrum: Summation averaging Octave: Summation averaging, exponential averaging, peak hold Probability density function: Summation averaging Number of averages: 1 to 8192 3.5-inch floppy disk drive (CF-4220Z only) Number: 1 Format: MS-DOS format (1.2 M/1.44M) Voltage input (/CF-4220Z) Charge amp: CH-1200 Display function Display: 6.4-inch liquid crystal display Waveform display mode: Single frame, dual frame, two overlaid frames Display functions: Y-axis auto scaling, Y-axis manual scaling, maximum value display function, search function, cursor function, list display, label function, setup display, etc. Memory section Screen data block memory: 30 frames maximum Panel condition setups: 4 types Comparator function (Option CF-0460Z) Functions that can be processed: Power spectrum, 15 band 1/3 octave, 5 band 1/1 octave Specifiable maximum number of blocks: 16 Comparison judgment: Level, maximum value, area percentage, segment overall value, peak level Output of judgment results: When the judgment is OK: contact closed; when the judgment is NG: contact open. Please note however, that the OK/NG logic can be changed. Display of judgment results: The OK/NG judgment results can be displayed on the LCD. Automatic saving of NG data: When the judgment is NG, the data can be saved automatically to the screen data block memory or to a disk (in common with the auto store function) Relay contact input: Six functions such as Start, Start Comparison Judgment, and so forth can be freely used as the ON/OFF switch. Interface: RS-232C General specifications Power supply: 90 to 264 VAC (50/60 Hz) Power consumption: Approx. 50 VA Operating temperature range: 0 to +40 C Storage temperature range: -10 to +60 C Outer dimensions: 200 (W) x 292 (H) x 396.4 (D) mm Weight: ; Approx. 4.4 kg CF-4220Z; Approx. 5.2 kg Options CF-0460Z: Comparator & RS-232C card

Outer Dimensions CF-4220Z 200 (12) 270 (10) OPTION (CF-0460Z) 41 (11.4) (35) 350 Outer appearance and specifications are subject to change without prior notice. * URL: http://www.onosokki.co.jp/english/english.htm U.S.A. & CANADA Ono Sokki Technology Inc. 2171 Executive Drive, Suite 400 Addison, IL. 60101 U.S.A. Phone : 630-627-9700 Fax : 630-627-0004 URL : http://www.onosokki.net E-mail : info@onosokki.net THAILAND Ono Sokki (Thailand) Co., Ltd. 29/67 Moo 5 Tivanon Road, Pakkred, Nonthaburi 11120, Thailand Phone : 02-964-3884 Fax : 02-964-3887 E-mail : osth_sales@onosokki.co.jp P.R.CHINA Ono Sokki Beijing Office Beijing Jing Guang Center 3510 Hu Jia Lou, Chao Yang Qu Beijing P.R.C. 100020 Phone : 010-6597-3113 Fax : 010-6597-3114 E-mail : onosokki@public.bta.net.ch WORLDWIDE Ono Sokki Co., Ltd. 1-16-1 Hakusan, Midori-ku, Yokohama 226-8507, Japan Phone : 045-935-3976 Fax : 045-930-1906 E-mail : overseas@onosokki.co.jp on 100% Recycled Paper CAT. NO. 536-01E-01 Printed in Japan 06X (SK) 2K