Installation Instructions 4291 and 4292 Keypads

Similar documents
9212i INSTALLATION. Stand-Alone Keypad. Instructions

Digital Keypad Introduction

KP2000E/EM Series Style Keypad

2000 Series e/em Style Keypad Installation and Programming Manual

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Installing Keypad and Backplate

THE CTB08D LIGHT CONTOLLER

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

232iLM Keypad Installation and Programming Instructions

Keypad Programming Instructions for the Profile Series LK and v.g1.5 Locks A7857A

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

DG-800 Stand-Alone Proximity Reader Instruction Manual

212iL Rev. 1.1

232iLM Keypad Installation & Programming Instructions

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

*740130* 2800, 9500 Series. Cable Companion Motor Power. Cable AC Power. Cable Retrofit Acessories

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

Two Door Controller GEN-045

EL-ST100 KEYPAD CONTROLLER

MAXIMA + Series ROTARY LEVEL CONTROL

INSTALLATION INSTRUCTIONS E77 SERIES STANDALONE ELECTRONIC LOCKSET

CM-110SK Standalone Keypad Installation Instructions

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL

MAXIMA+ Series Rotary Level Indicator

SAVE THESE INSTRUCTIONS

5 B&W Rear View System Camera

Stand-Alone Data Chip System

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

THIS FORM IS THE PURCHASE ORDER. DO NOT SEND A COVER P.O. DUPLICATED ORDERS CANNOT BE RETURNED. Technology/Description

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

DC Outdoor Power Supply/Chargers

User Manual. PCKeypad Wireless Keypad

Intelli-M eidc Quick Start Guide. infinias

ACTsmart2 Product Range Operating and Installation Instructions

SAVE THESE INSTRUCTIONS

Model HM-535 Power Supply Installation and Service Instructions

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Single Door Standalone Access Control User Manual

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

Programming/Troubleshooting Instructions

Key Switch. Document version: 1.5 (Updated 02 May 2017)

Installation Instructions

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

MAXIMA + Series ROTARY LEVEL CONTROL

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Installation Instructions For Profile Series Exit Device

REX F-0-9 Standalone or Access Controller

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ASI Systems ML5740A Series

B-33. Hardware and Install Manual. (DC 12V / PoE)

Waterproof. Keypad/Reader/Controller

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Operating instructions. Switching amplifier DN0210 DN / / 2015

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

Satellite INSTALLATION GUIDE

Quick Start Installation Guide

Connecting a Cisco Reader Module

PXL-250 Tiger Controller

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

Quick Start Installation Guide

Transceiver Hub with Integral Camera Power

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

Operating instructions. Speed monitor D / / 2014

2-Way Wireless I/O Expander Installation Guide

CP150B Vandal & Weather Resistant Keypad Security Systems

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions

Active UTP Transceiver Hub with Integral Isolated Camera Power

CONTROLLER BOARD CONVERSION KIT Rev Installation Instructions Part Number: PUPKIT

INTELLIKEY. Mini-DCU Installation Manual GENIUS AT YOUR FINGERTIPS. 1 rev

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

istar Pro Installation Guide

Quick Start Installation Guide

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Safety Control Relay Product Catalog

PARTNER Contact Closure Adjunct

UC-2000 Installation Manual Unicorn Computers Technology Limited

7612 Programming Instructions

IBA-7612 Programming Instructions

CA-A480-A Elevator Controller. Reference & Installation Manual

Installation Instructions

Transcription:

Installation Instructions 4291 and 4292 Keypads A6851J 02/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

1 2 General Description The 4290 Series Microprocessor Controlled Keypads provide keyless access primarily for electric locking devices requiring dry contact switching. User codes are programmed from the keypad to perform various functions. A yellow LED indicates keypad status and red and green user LEDs can be wired to display latchbolt and/or door status. The 4291 Keypad is designed for indoor use in a protective environment. The 4292 Keypad is weather resistant and can be used for outdoor use. Specifications Wallplate Finish Wall Plate Dimensions Mounting Screws Master Codes User Codes Memory Backup Voltage Input Current Draw 45mA Green User LED Red User LED Yellow User LED Control Ouput Momentary Control Maintained Control Temperature Range Tamper Feature Special Features (Connector Output) Auxiliary Output (2) Keypad Active Panic Output Request to Exit Stainless Steel (US32D) 4.50 x 2.75 x 1.53 (2) 6-32 Tamper Resistant (2) 6-32 Slotted Oval 1 (1 to 6 digits) 15 (1 to 6 digits) Non Volatile 24VDC 45mA 24VDC, 15mA 24VDC, 15mA Keypad Status SPDT Dry, 8A, @ 24VDC Res. 0-90 Seconds Infinite -20-130 F 3 Incorrect Entries/ 15 Second Lockout 24VDC, 50mA (SINK) 24VDC, 50mA (SINK) 24VDC, 50mA (SINK) Dry Contact Activated 3 Functions 1. Control Output (Terminal Strip TS-1) Enter programmed user code to activate this output for 0-90 seconds or maintained. This is a Form C dry contact output and should not exceed 8 AMP (24VAC RES) load. It is used to control an electric locking device. 2. Auxiliary 1 Output (Wht/Red) Enter programmed user code to activate this output for 0-90 seconds. This output should not exceed a 50mA (24VDC) load. It is used to control a relay, horn, LED etc. 3. Auxiliary 2 Output (Wht/Blu) Enter programmed user code to activate this output for 0-90 seconds or maintained. This output should not exceed a 50mA (24VDC) load. It is used to control a relay, horn, LED, etc. 4. Keypad Active (Wht/Blk) Enter any key and this output will activate for 10 seconds (from last keypress). This output should not exceed a 50mA (24VDC) load. When used in conjunction with an auxiliary relay, it can control LEDs or a CCTV camera. 5. Panic Output (Org) Enter * and # keys simultaneously to activate this output for 1 second duration. The orange wire output should not exceed a 50mA (24VDC) load. It is used to control a relay, horn, LED, etc. 6. Request to Exit (Wht/Org, Brn) A momentary closure (N. O. dry contact) will activate the Control Relay for the same time period as programmed for the Master Code. It is used in conjunction with a Motion Detector for exiting. Refer to Fig. A, following page. 7. Tamper Feature A 15 second keypad lockout will occur if (3) improper codes are entered. 8. Passage Mode Programming this feature changes the state of the keypad relay contacts. Its intended use is to maintain the door in the unlocked mode. Master code and user codes cannot be used in this mode. 2 1-800-810-WIRE www.sargentlock.com A6851J

4 Mounting Instructions A. Important CAUTION: Disconnect all power before beginning installation to prevent electrical shock and equipment damage. 1. Installer must be a trained, experienced service person. 2. All wiring must comply with applicable local electrical codes, ordinances and regulations. B. Installation 1. Mount outlet box to stud or other rigid structure. Use Outlet Box Slater S1-18W for indoor applications and Waxman 35-276 for outdoor applications (not furnished). 2. Install and wire electric locking devices, monitoring components and power sources to appropriate keypad connections. 3. Figure A shows color code wiring connections on keypad. 4. Figure B (pg.3) shows typical wiring when using SARGENT s electrical locking devices with accessories. 5. Fasten wallplate with keypad to outlet box using machine screw furnished. See Figure C for 4292 keypad outdoor installations. 6. Energize power supply and refer to Programming Procedures (pg. 5) Wiring Harness Warning: Plug this harness in on the proper pins. Permanent damage will result if incorrectly inserted. 10 9 8 7 6 5 4 3 2 1 White Wht/blue Wht/red Orange Brown Wht/orange Wht/black Wht/yellow Black Red Note: LED s shown are for the 4291 keypad. LED s for 4292 are located on the front right side. Not used Aux 2 Output (SINK 50mA) Aux 1 Output (SINK 50mA) Panic Output (SINK 50mA) Request to Exit Input Request Input Common Keypad Active (SINK 50mA) N/A Output Ground (Only) 24 + Fig. A 1-800-810-WIRE www.sargentlock.com A6851J 3

,1.5A SLO BLO TF USE 4291 and 4292 Keypads Typical Wiring with SARGENT Electric Locking Devices, 3510 Power Supply and Door Status Switch 3510 24VDC/1.8AMP Power Supply L NG ND INPUT OUTPUT 1 +- +- OUTPUT 2 120VAC,.8A, 60HZ 24VDC, 1.8A 120VAC L/N/G (+) (-) Red (Red LED) Red (Green LED) (N.O) (N.C) (C) - 4291 or 4292 Keypad Fig. B (N.O) (N.C) *Black *Red See Note 4 Electric Hinge 3287 Door Status Switch Electromechanical Locks 8200/7800 Mortise 10 Lined Bored 773-773 ET 775-776 ET 56- EXIT 58- EXIT * Colors of wires shown are leads from the Electric Locking Device only, not Electric Hinge. 4 1-800-810-WIRE www.sargentlock.com A6851J Note: Consult 3287 instruction sheet for proper wire colors

4292 Weather Resistant Mounting Diagram CAUTION: The 4292 is not weatherproof, it is only weather resistant. It may be installed outside, but the following precautions must be followed. 1. Do not install in any area where direct rain will strike the keypad or where water will run down the wall and seep into the keypad. 2. When mounting the 4292 outside, apply silicone to the area where wires enter the case, and install a weep hole at the bottom of the box. This will help prevent warm air from condensing on the circuit board. Water shield: This shield should fold down from the top to allow moisture to run away from the board. Wires should be run so that they do not interfere with the placement of the shield. Tamper resistant screws recommended (provided) Wiring Harness Gasket (provided) Add weep hole for wet environment 4292 Weather Resistant Wiring Diagram Notes 1. Wires must be protected from abrasion. 2. For use with Class II circuitry only. NOTE: Dots ( ) indicate wire connections. 3. Use N.C. Relay Contacts for Fail Safe Lock (normally energized). Use N.O. Relay Contacts for Fail Secure Lock (normally de-energized). 4. Insulate any loose wires from Outlet Box and each other. 5. When operating inductive loads such as electric strikes and solenoid operated locks (10G70-73, 8270-73 etc.) the supplied transorb must be installed. For locking devices that have built in protection, the use of the transorb is not necessary. Refer to the literature furnished with the locking device for this information. SARGENT 56-, 57-, 58- and 59- devices do NOT require use of transorb. IMPORTANT: The transorb must be installed as close to the locking device as possible. This is to prevent the electrical (inductive) kickback voltage generated by the locking device from damaging the keypad. 24VDC 24VDC 4291 or 4292 Keypad + - NC C NO 4291 or 4292 Keypad + - NC C NO Magnetic Door Lock (Fail Safe) Transorb Electric Strike (Fail Secure) Transorb 1-800-810-WIRE www.sargentlock.com A6851J 5

5 Programming The keypads come pre-programmed with the master code 1234*. The master code is used to program your fifteen (02-16) user codes and functions. If you are unsure of where you are in programming, press the * key several times until the yellow LED is off and start again at the beginning. Also, if no key is pressed for 30 seconds, the programming mode in process is automatically aborted. A. Program Users Codes 2 Through 16 1. Enter 99# to initiate programming sequence. 2. Enter Master Code*. This code can be changed, refer to C. Changing the Master Code. 3. Enter two digit time duration desired. Enter 01 to 90 seconds for Momentary Function. Enter 00 for Maintained Function. 4. Enter two digit user number. Enter 02# to 16#. 5. Enter Selected User Code. Use between a one and six digit number followed by a *. 6. Repeat step 5. Sample Programming: B. Delete User Codes 2 through 6 1. Enter 99# to initiate deleting sequence. 2. Enter Master Code*. This code can be changed, refer to C. Changing the Master Code. 3. Enter two digit user number desired to be deleted. Enter 02# to 16#. 4. Enter ** to complete deletion. 6 1-800-810-WIRE www.sargentlock.com A6851J

C. Changing the Master Code 1. Enter 99# to initiate programming sequence. 2. Enter current Master Code*. 3. Enter time duration: 01-90 seconds. 4. Enter 01#. 5. Enter new desired Master Code. 6. Use between a one and six digit number, followed by a *. 7. Repeat step 5. Sample Programming: NOTES: If LED does not turn off, the code entered has not been verified. Press * and repeat Steps 1-6. If the Master Code is unknown, Programming or Changing Mode can be entered by removing the keypad from the outlet box and momentarily pressing SW1 (reset button) on the circuit board. For location, see Mounting Instructions, page 2. The yellow LED will flash slowly and programming should proceed from Step 3. D. Programming for Special Functions 1. Enter 99# to initiate programming sequence. 2. Enter Master Code*. 3. Enter Special Function Code. 91-Code operates Aux 1./Time Duration 92-Code operates Aux 2./Time Duration 98-Code operates Aux 1, and Control Relay (Master Code duration) 4. Enter two digit time duration desired. Enter 01 to 90 seconds for momentary Function. Enter 00 for Maintained Passage Function. 5. Enter User Number. Enter 01# to 16#. 6. Enter Selected User Code. Use between a one and six digit number followed by a *. 7. Repeat Step 6. Sample Programming: NOTES: 1. If User Number 01# is used then its user code is the master code. 2. Special function 98 should not be used with User 01#. 3. AUX1 duration is common for all users of AUX1. Changing it for one user changes it for all users. 4. Special Function 98 uses duration set in section "c" for Main Relay and common duration for AUX1. Setting a duration for Special Function 98 is ignored. 1-800-810-WIRE www.sargentlock.com A6851J 7

SARGENT Manufacturing 100 Sargent Drive New Haven, CT 06511 USA 800-810-WIRE (9473) www.sargentlock.com Founded in the early 1800s, SARGENT is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company s customer base includes commercial construction, institutional, and industrial markets. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. A6851J -02/11