Getting Started Guide

Similar documents
DTX-NSM Network Service Module Getting Started Guide

NX1 Pocket Toner Users Guide

NX8 Pocket Toner Users Guide

AirCheck. Wi-Fi Tester. Getting Started Guide. PN December 2009 Rev. 1 3/10

IT100. Users Manual. IntelliTone Pro Toner and Probe

DTX-PCU6S. Users Manual. Patch Cord Adapters

Visit us at

DTX-PCxxS. Users Manual. Patch Cord Test Adapters

9040/9040UK. Users Manual. Phase Rotation Indicator

GPS Synchronization Module

TS 120. Test Telephone. Users Guide

MicroScanner 2 Cable Verifier Raising cable verification to a higher power

Residential Cabling Solutions. More vision into residential cabling. Network SuperVision Solutions for voice-data-video networks NETWORKSUPERVISION

TiR2, TiR3, TiR4. Getting Started Guide. IR FlexCam Thermal Imager

TiR2,TiR3,TiR4, Ti40,Ti45,Ti50,Ti55 IR FlexCam Thermal Imager

AirCheck. Users Manual. Wi-Fi Tester

Airborne Particle Counter

Datasheet: CableIQ Qualification Tester - The network tech s vision into cabling bandwidth.

AirCheck. Users Manual. Wi-Fi Tester

Temperature Humidity Meter

AirCheck. Wi-Fi Tester. Getting Started Guide

Power Quality Recorder

AirCheck. Users Manual. Wi-Fi Tester

XS, XST. IR InSight Thermal Imager. Getting Started Guide

Power Quality Recorder

OptiView Protocol Expert Quick Start Guide

Advanced Test Equipment Rentals ATEC (2832) OMNIScanner 2 OMNIFiber

UÊ, Ê* - 1 Ê Ê Ê " /",Ê

DTX Series. Users Manual. CableAnalyzer

JANUARY 2000 TS800A TS801. MicroScanner

TR100-A / TR200-A. Temperature / Humidity Data Loggers. Users Manual. For detailed specifications and ordering info go to

Chapter 3 Certifying Twisted Pair Cabling

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

660 Series. Frame Relay Installation Assistant. Users Guide

709/709H. Calibration Manual. ma Loop Calibrator

HDMI Over IP Receiver for ST12MHDLAN

DTX Series. Technical Reference Handbook. CableAnalyzer

Electrical Measurement Module Kit with Docking Station

Introduction. Package Contents. System Requirements

OneTouch AT Network Assistant Configuration Guide

MIR-K16S-2101Q IR Distribution Kit with 6 Ports

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Zonit μats TM Users Guide μats1-lv Version 1.2

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

TMA40. Airflow Anemometer. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

USB 2.0 LR 4-Port Extender

25D Test Set Users Guide

Wireless Doorphone Intercom

MTP INSTRUCTION MANUAL

PTT-100-VZ Wireless Speaker Microphone

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

DTX Series. Technical Reference Handbook. CableAnalyzer

SignalTEK II. idealindustries.com

3M Constant Monitors WSMONITOR1, WSMONITOR 2, WSMONITOR3

PIECAL 520B & 521B Thermocouple Source Operating Instructions

DTX-MFM/GFM/SFM. Fluke Networks DTX-GFM Specs. Users Manual. Provided by Fiber Modules

VR1710. Users Manual. Voltage Quality Recorder

700 Series 200 Amp Clamp Meters

t3000 FC Calibration Manual Wireless K-Type Thermometer

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

DTX Series. Fluke Networks DTX-1200 Specs Provided by Users Manual. CableAnalyzer

Proliphix EPA-60 Installation Guide

Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking

TeraJet DOCSIS Modem Installation. Guide

FlukeView Forms. Documenting Software. Getting Started

KVM - DVI, Audio, USB 2.0, Cat 5 Extender

LinkRunner Pro TM. Network MultiMeter Quick Reference Guide. Welcome. Safety. What s in the box? Item

GE A Acoustic Belt Tension Tester. User s Operation Manual

Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.

Application of Cable Assembly

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide

OFSR-X. Users Manual. OptiFiber Smart Remote Options

PWRguard PLUS Spring City Drive Waukesha, WI

Net Prowler TM. Identify, Monitor & Test LAN Issues Quick Start Guide TNP700 TNP800 TNP850K1

USER S MANUAL MODEL VP6630

USB 2.0 Ranger High Speed Extender System. User Guide

Serial ExpressCard 4 port 16C950 Serial ExpressCard

FlukeView. Users Manual. Software for ScopeMeter Test Tools

3M Workstation Monitor Checker CTE701A User s Guide

user s manual LoudSpeak r model #: BTS01 Portable Bluetooth Speaker

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

Datasheet: IntelliTone Pro 200 LAN Toner and Probe Series

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Telephone Line Monitor USER GUIDE

v3001 FC Wireless DC Voltage

CableMaster CM200 Compact and economic cable tester

4 Port USB 2.0 Extender over Gigabit Ethernet or Cat5e/6 Cabling - 100m (330ft)

CAT5-1600A Extender. EXT-CAT5-1600A User Manual.

FastForward TM User Guide

Targus Wireless 2.4 GHz Presenter

PS/2 & USB KVM Console Extender

FastForward User Guide

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

USBTHERE User Guide USB110EXT USB120EXT. USB110 EXT shown. Extending the Range of USB

ScopeData Pro User s Guide

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

Woolich Racing. USB ECU Interface User Guide

CONTENTS 1. BOOMBOT ANATOMY 2. GETTING STARTED 3. BLUETOOTH PAIRING 4. AUDIO CONTROLS 5. SPECIFICATIONS 6. TROUBLESHOOTING 7.

Transcription:

TM CableIQ Qualification Tester Getting Started Guide PN 2113427 January 2005, Rev. 1 3/07 2005, 2007 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITY Fluke Networks mainframe products will be free from defects in material and workmanship for one year from the date of purchase. Parts, accessories, product repairs and services are warranted for 90 days, unless otherwise stated. Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories. This warranty does not cover damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke Networks behalf. To obtain service during the warranty period, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then send your defective product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE NET- WORKS IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, IN- CIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. 4/04 Fluke Networks PO Box 777 Everett, WA 98206-0777 USA

CableIQ Qualification Tester Accessing the Users Manual This guide provides basic information to help you quickly get started using the tester. The CableIQ Qualification Tester Users Manual on the Product CD provides additional information. Safety XWWarning The tester is not intended to be connected to active telephone inputs, systems, or equipment, including ISDN devices. Prolonged exposure to the voltages applied by these interfaces may damage the tester. Disconnect the tester if the voltage alert symbol (V) appears. Read the safety information given in the CableIQ Users Manual on the Product CD before using the tester. Controls axy01 1

CableIQ Getting Started Guide Setting User Preferences Turn the rotary switch to SETUP; then use AD and H to select a setting. User Information: Three lines of text are stored with saved Autotests. Language / ft m: Select a language for the display. Select feet or meters for length measurements. Time / Date: Timestamp saved Autotests. Auto Shutoff: The tester stays on indefinitely or turns off after 15 minutes of inactivity. Editing Text Use the keys to edit text on the User Information and Enter ID screens. H: Selects the highlighted field for editing. B C: Moves the cursor. Moving the cursor beyond the last character inserts the first character from the last character s set. A D: Changes the highlighted character. J Ins: Inserts the first character from the set that includes the highlighted character. K Del: Deletes the highlighted character. SHIFT and D or SHIFT and A: Changes the character set. Character Sets Available ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 0123456789 #"!$%&'( )*+,-./:;<=>?@[ \ ]^_ `{ } space 2

Connecting for Cabling Tests Connecting for Cabling Tests Notes A wiremap adapter or remote ID locator must be connected to the end of the cabling for the wiremap to be completely verified. If you use patch cords at the near or far end during an Autotest, Fluke Networks recommends patch cords at least 2 m long. Connecting to a Data Link axy10 Connecting to a Bus Topology axy13 3

CableIQ Getting Started Guide Connecting to a Star Topology axy12 Connecting to Coaxial Cabling axy34 4

Results Icons Results Icons The icons below appear on Autotest and Discover screens. F f i The cabling qualifies for the application. The cabling does not qualify for the application. Results are for informational purposes only, not for qualification. The cabling cannot be completely qualified for the application because the wiremap results are incomplete (wiremap adapter not used). O Pair is open. N Pair is shorted. W R Wiremap adapter or remote ID locator at far end, with its number. E Bridge tap detected. Q Hub, switch, or PC NIC card detected. Port speeds are 10, 100, 1000 Mb/s. V Voltage detected. This may indicate an active telephone circuit, ISDN line, or Power over Ethernet (PoE) device. U The tester is connected to an active telephone circuit. T A signal is present on the pair.? The tester cannot identify the termination. 5

CableIQ Getting Started Guide Discovering Cabling Characteristics Discover mode lets you quickly check wiremaps, measure length, and determine if cabling is connected to a network port, video device, or telephone. Turn the rotary switch to DISCOVER, then connect to twisted pair or 75 Ω coaxial cabling with or without a wiremap adapter at the far end. Results from Discover mode cannot be saved. Discover Mode on Twisted Pair Cabling axy46 Discover Mode on a Bridge Tap axy49 6

Discover Mode on a Port Discovering Cabling Characteristics axy48 Discover Mode on Coaxial Cabling with Adapter axy50 Discover Mode on Coaxial Cabling Connected to a Device axy35 7

CableIQ Getting Started Guide Discover Mode with MultiMap Verifies wiremaps of multiple telephone outlets connected in a star or bus topology. Qualifying Cabling with the Autotest axy07 The Autotest tells you if cabling will support a selected application. You can save Autotest results to document an installation. Connect to the cabling as shown on pages 3 and 4. Turn the rotary switch to AUTOTEST. To select tests and pairs to test, press J Setup. To start the test, press P. Note The Autotest does not support use of multiple remote ID locators (the MultiMap function). To save the test, press K S. You can enter a Site name, Location, and Outlet to identify the results. The last character of the Outlet string increments each time you save an Autotest. 8

Autotest Results for Twisted Pair Cabling Using the Toner Using the Toner axy14 Turn the rotary switch to TONE; then select a tone function. The two IntelliTone functions work with a Fluke Networks IntelliTone probe. The other four analog tones can be detected by most tone probes. axy06 9

CableIQ Getting Started Guide Blinking a Port Light The Blink Port Light function helps you determine which cable is connected to which port on a network hub or switch. The tester s analog toner is also active when the port light function is active. Turn the rotary switch to DIAG; then select Blink Port Light. Look for the blinking activity LED on the hub or switch. axy05 10

Testing for Continuity Testing for Continuity The continuity function lets you test for opens and shorts on the 8-pin modular jack or the coaxial connector. Turn the rotary switch to DIAG. Use D to highlight Continuity; then press H, J, or P. The tester s beeper is silent for resistances above about 5000 Ω. The beeper s tone and rhythm increase as resistance decreases. axy37 11

CableIQ Getting Started Guide Using the Continuity Toner Turn the rotary switch to DIAG; then select Continuity. The beeper s tone and rhythm increase as resistance decreases. Locating Crosstalk and Impedance Faults The Find Crosstalk Fault and Find Impedance Fault functions let you quickly check cable pairs for crosstalk and impedance faults on twisted pair cabling. Turn the rotary switch to DIAG, select Find Crosstalk Fault or Find Impedance Fault; then press H or J. Select a transmission standard and pair or pairs to test; then press P. A wiremap adapter or ID locator is not required. axy38 12

Testing Speaker Cabling Testing Speaker Cabling The Speaker Test generates audible tones for testing the wiring and phase of installed twisted pair speaker cabling. Turn the rotary switch to Diag; then select Speaker Test. 4-clip test lead wiring: + Pair 12: green + Pair 45: blue - Pair 36: orange - Pair 78: brown axy39 13

CableIQ Getting Started Guide Replacing the Batteries Remove yellow boot to access battery door. 4 AA batteries (alkaline recommended) 20 hours typical battery life. axy53 Contacting Fluke Networks www.flukenetworks.com support@flukenetworks.com +1-425-446-4519 Australia: 61 (2) 8850-3333 or 61(3) 9329 0244 Beijing: 86 (10) 6512-3435 Brazil: 11 3044 1277 Canada: 1-800-363-5853 Europe: +44-(0) 1923 281 300 Hong Kong: 852 2721-3228 Japan: 03-3434-0510 Korea: 82 2 539-6311 Singapore: 65 6799-5566 Taiwan: (886) 2-227-83199 USA: 1-800-283-5853 Anywhere in the world: +1-425-446-4519 Visit our website for a complete list of phone numbers. 14