USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Similar documents
True RMS AC Voltage/Current Datalogger

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Model A Mini AC/DC Clamp Meter. User's Guide

Humidity & Temperature Datalogger

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User's Guide. EasyView K-Type Thermometer. Model EA11A

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

User Manual. Thermocouple Datalogging Thermometer. Model EA15

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

User's Guide. Datalogging Hygro-Thermometer Model SD500

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

Dual Moisture Meter Pin / Pinless Moisture Meter

Indoor Air Quality Meter/Datalogger

Heavy Duty Datalogging Light Meter

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

User's Guide. 3 Channel Datalogging Thermometer Model SD200

Humidity & Temperature Datalogger

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

Digital Sound Level Meter

Model A Current / Voltage Calibrator. User's Guide

Vibration Meter and Laser Combination Tachometer

User's Guide. Digital Multimeter. Model MN42

User's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

Vibration Meter SD Card real-time datalogger

Hygro-Thermometer / Datalogger

Datalogging Hygro-Thermometer

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

RS Stock No Instruction Manual RS Input Data Logging Thermometer

User's Guide. Hot Wire Thermo-Anemometer. Model

Model A Current Calibrator. User Guide

Datalogging Hygro-Thermometer

Light Meter SD Card real-time datalogger

3 Channel Datalogging Thermometer

USER GUIDE. AC/DC Magnetic Meter. Model MF100

Digital Sound Level Meter MODEL

4-Channel Vibration Datalogger

User's Manual. Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface. Model

User Guide. Video Borescope. Models BR200 and BR250

Mini Digital Multimeter

Barometric Pressure / Humidity and Temperature Datalogger

4-Channel Thermometer / Datalogger

User's Guide. Extech AM A AC Analog Clamp Meter

USER GUIDE. Differential Thermometer Datalogger. Model HD200

Mini Digital Multimeter Model MN15. User's Guide

User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer

ph/orp Meter SD Card real-time Datalogger

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide. Video Borescope. Models BR200 and BR250

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

USER GUIDE. Heavy Duty Differential Pressure Manometer. Model HD700

Earth Resistance and Resistivity Tester

Sound Level Meter SD Card real-time Datalogger

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

USER GUIDE Current Calibrator

12-Channel Thermocouple Datalogger

Heat Stress WBGT Meter

User's Guide. Extech CG204 Coating Thickness Tester. 99 Washington Street Melrose, MA Phone Toll Free

User's Guide. Phase Sequence and Motor Rotation Tester Model

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

High Precision Quad Output DC Power Supply

User's Guide. Humidity + Temperature + Pressure Datalogger. Model RHT50

3-Phase Power Analyzer/Datalogger

Auto-timer Datalogging Temperature / Humidity Meter

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

User Guide True RMS Multimeter Extech EX205T

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

True RMS Industrial Multimeter Extech EX520

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Humidity + Temperature + Pressure Datalogger

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Personal Sound Level Meter

User's Guide. Model W 3-in-1 Switching DC Power Supply

Thermocouple Calibrator

ENGLISH. User manual.

9040/9040UK. Users Manual. Phase Rotation Indicator

Extech EX845 True RMS 1000 Amp Clamp Meter with Bluetooth

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

1000A 3-Phase Power Analyzer/Datalogger

1366 INSTRUCTION MANUAL

User Guide. Moisture Meter. Model MO250

11 in 1 Environmental Meter

Wireless TRMS Multimeter and Insulation Tester

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

DC / AC True RMS Watt Clamp DMM

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Heavy Duty Datalogging Light Meter

TEMPERATURE / HUMIDITY /DEW POINT METER

True RMS Industrial Multimeter Extech EX530

Mini Digital Multimeter

USER GUIDE Turbidity Meter Model TB400

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented

Coating Thickness Tester

User's Guide. Cup Thermo-Anemometer. Model AN400

SuperHeat Psychrometer Models RH350 and RH355 (kit)

Transcription:

USER GUIDE Dual Input True RMS AC Voltage/Current Datalogger Model DL160

Introduction Congratulations on your purchase of this Dual Input Voltage / Current datalogger. With this meter, you can monitor and log data (Voltage/Voltage, Current/Current or Voltage/Current) over long periods of time and then easily transfer the data to a pc for viewing and evaluation. The LCD display provides real time data, Max/Min data and time information. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Safety Warning! Do not attempt to make measurement in flammable gaseous areas! When testing a non-insulated cable, pay attention to avoid short circuits. Do not attempt to use the instrument when your hand is wet! Do not input over range during measurements. Never open the battery cover during measurements. Stop using the instrument when there is any structural defect or exposed metal parts. Do not install substitute parts or make modifications on the meter. Never replace the battery in moist areas. Ensure the meter is disconnected and switch off before opening the battery cover to replace the battery. Do not attempt to place the instrument in high vibration areas. Do not expose the meter to direct sunlight, high temperature and high moisture environment. Switch off the meter after use. Remove the AAA batteries when the meter will be stored for a period of time.. When cleaning, do not use abrasives or solvents on the meter, use a damp cloth and mild detergent only. 2

Description and Button Functions 1. LCD Description REC: FULL Auto power off (does not apply when recording), the meter will automatically shuts off after 5mins without any button presses. Recording status. After the record mode is set up by the software, press the START/STOP button for more than 4 seconds to begin recording. This icon will be displayed and indicates the meter is recording data. Press the same button again for more than 4 seconds to stop recording. Record until full is selected. When the memory is full, the datalogger will stop recording. Continuous recording is selected. When the memory is full, the data will overwrite the oldest data. Memory full and recording has stopped. Battery status, when completely filled in (black) the battery power is full. When there is only one section filled in, the battery is exhausted and should be replaced with a new one. 2. AC adaptor Jack 3. ON/OFF Button 4. MAX/MIN: Press the button one time to display the MAX (maximum) reading. Press again to display the MIN (minimum) reading. A third press will exit MAX/MIN mode. The meter will automatically exit MAX/MIN mode in 10 seconds if no button is pressed. 5. CH Input Jacks: Insert the current or voltage sensor to these ports to measure and record the data. 6. CHANNEL: Select the channel for display on the LCD 1 2 3 4 5 8 7 6 7. START/STOP: After the datalogger is setup from the software, press the START/STOP button for 4 seconds to begin recording. Press the button again for 4 seconds to stop recording. Recording cannot be started again until the data is downloaded to the software! 8. USB Port 9. AC Current Clamp Jaw: Clamp the jaws around a single conductor for AC current measurements to 200A 10. Jaw Opening Trigger 9 10 11 11. CH Plug 12. AC Voltage Probes or Alligator clips 13. Voltage module 14. CH Plug 13 12 14 3

Operation 1. Install 4 fresh AAA batteries or connect the AC adaptor. 2. Set-up the datalogger using the software provided. 3. Connect the voltage test leads or the current probes to the AC source to be measured. 4. Press and Hold the START/STOP button for four seconds to start recording. The REC icon will appear in the display indication that recording has begun. 5. Press and Hold the START/STOP button for four seconds to stop recording. The REC icon will disappear from the display. 6. Remove the probe, connect the datalogger to a PC and use the supplied software to download the data. Note: If the clock does not set to the correct time, replace the 3V button battery. You, as the end user, are legally bound (Battery ordinance) to return all used batteries and accumulators; disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle. Software Introduction 1. Place the CD in the drive and then follow the on-screen installation instruction. 2. After the software is installed, keep the CD in the drive and connect the datalogger to the PC by the USB cable. 3. A USB Driver installation window will pop-up. Follow the directions to install the driver. Software Operation The Software operation is described in the HELP file located on the software disk. 4

Specifications Display Multi-function LCD Maximum data points 262,000 (Single channel) or 131,000 (Dual channel) Channels dual channel, TRMS AC Voltage or Current Sample rate 1s to 24h selectable Data output USB port Current Clamp Jaw opening 12.7mm (0.5 ) Open input indication "LO" appears on the LCD Low battery indication Empty battery symbol appears on the LCD Power supply 4 AAA Batteries and 1 CR 3V memory button battery (CR2032 or equivalent) Battery life 5 days (approximately) AC Adaptor 9V, 0.5A Standards CC, CAT III 600V, for inside use, maximum height 2000 meters Operating Temperature 0 to 50 C, 32 to 122 F Operating Humidity <70% RH Storage temperature -20 C to 60 C (-4 F to 140 F) Storage Humidity < 80% relative humidity Dimensions 114 x 63 x 34mm (4.5 x 2.5 x 1.3) Weight 248g. (8.7oz) Function Range Accuracy Voltage (40Hz to 1kHz) 10VAC to 600.0VAC ±2.0%±1V Current (50/60Hz) 10A to 200.0A ±2.0%±1A Copyright 2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form. www.extech.com 5