Gas detection just got personal

Similar documents
Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Exposure Monitoring HEALTH AND SAFETY

MET ONE HHPC+ Series Handheld Particle Counters. Simple Fast MET ONE MET ONE

Microdust Pro Real-Time Dust Monitor

DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532

MC Toolkit (Rugged & Intrinsically Safe models)

G460 Multi-gas Detector

4-gas detector. Versatile multi-gas H 2 S O 2 SO 2 LEL

SENSIT P400. Accessories. Replacement Parts. Calibration Kits. Calibration Gases MADE IN THE USA WITH GLOBALLY SOURCED COMPONENTS

Temperature & Humidity Datalogger

SENSIT IRED INSTRUCTION MANUAL INFRARED ETHANE DETECTOR READ AND UNDERSTAND INSTRUCTIONS BEFORE USE. 851 Transport Drive Valparaiso, IN

Model KB 400 Cooling incubators with compressor technology

Operation Manual IMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone: E-mai:

Infrared temperature measuring instrument

Sulfur-in-Oil Analyzer SLFA-60

CEL-350 dbadge / CEL-352 dbadge Plus Personal Sound Exposure Meter

Data Cal 2000 Operator s Manual

SDM-03 Docking Station Standalone Configuration Operator s Manual

Eltek TU GenII AQ110A comprehensive portable air quality monitor transmitter

SDM-6000 Docking Station Standalone Configuration Operator s Manual

SDM-2012 Docking Station PC Controlled Configuration Operator s Manual

Easidew Portable Hygrometer

ARP992/ ARP992-B User Reference Manual

The Apex, for professional air sampling in all monitoring scenarios

Model 475 Field Communicator. Connection. Environmental. Shipping Weight

In North America call toll free: Fax

Flue Gas Analyzer. The Value Leader TM

EC 600 Electronic Volume Corrector

Key Features. Applications

See more with the NEW testo 880 thermal imager

Phone: Fax: For calls outside the US please call:

from P.R.Engineering Ltd Tel:

SENSIT GOLD CGI. Accessories. Replacement Parts. Calibration Kits. Calibration Gases MADE IN THE USA WITH GLOBALLY SOURCED COMPONENTS

ARL992/ ARL992-B User Reference Manual

Hand-Held Thermometer Model CTH 6200

GA-12. madur Polska sp. z o.o.

SIDEPAK AM510 Personal Monitor

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

News from EIUK. The New RASI 300 Flue Gas Analysers. Plug & Play sensors User Replaceable plug and play sensor

Certificate of Conformity

Indoor Air Quality Meter/Datalogger

UNIVERSAL TEMPERATURE TRANSMITTER

EAGLE IMAGER 320 T H E R M A L I M A G I N G C A M E R A S T H E N E X T G E N E R A T I O N

SENSIT HCN. Accessories. Replacement Parts. Calibration Kits. Calibration Gases MADE IN THE USA WITH GLOBALLY SOURCED COMPONENTS

Carbon Monoxide (CO) Gas Detection and Control System

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

CI-150 Series. Airborne Particle Counters

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

BYK-mac. Total color impression of effect finishes. Ergonomic design and easy operation. Reliable readings at any time

DS404. Software Installation and Operations Manual. Multi-Inlet Docking Station. (800) (734)

SENSIT GOLD. Accessories. Replacement Parts. Calibration Kits. Calibration Gases MADE IN THE USA WITH GLOBALLY SOURCED COMPONENTS

DS400 / DS404. Software Installation and Operations Manual. DS400 Docking Station. (800) (734)

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Formaldehyde Thermo-Hygrometer

ARP 970 User Reference Manual

Optical CWDM Power Meter

Operation MANUAL. CARBOMETER - CO2 concentration measurement unit. LAMBDA CARBOMETER - CO 2 concentration measurement unit

MC Toolkit Rugged & Intrinsically Safe models Model MCT404 Specification 34-ST , July 2017

Technical Data FLIR i7

User s Guide. OM-EL-WiFi-TH. Data Logger. Shop online at omega.com. Temperature Data Logger With Graphic Screen

ARP 945 User Reference Manual

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

WP-82Y. WP-82Y Waterproof Dissolved Oxygen - Temperature Meter. TPS Australia - Quality hand-made instruments since Rugged and Waterproof

FiberBasix 50 Handheld Testers

Humidity/Temperature Dataloggers

Model BS-150. Instruction Manual. Video Inspection Camera. reedinstruments. www. com

ARL 945/ ARL945-B User Reference Manual

SDM-6000 Docking Station Standalone Configuration Operator s Manual

C2000 POWER METER With Data Storage

PM-100 SERIES. Operation Guide. Power Meter V

Hand-held thermometer Model CTH7000

REGULATORY COMPLIANCE. Each device complies with the EMC Directive 2004/108/EC and is CE marked

MX 62 CONTROLLER. Certifications. Better detection. Better protection. Monitoring system for gas and flame detection

USER MANUAL Video Particle Counter with built in Camera Model VPC300

Hand-held thermometer Model CTH6200

Waterproof Construction. Notepad Function. Automatic Datalogging. Automatic Calibration. Good Laboratory Practices. Serial Interface Port

Dräger UCF 9000 NFPA Certified Thermal Imaging Camera

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

ARL 970/ ARL970-B User Reference Manual

WP-81 Waterproof Conductivity/TDS-pH/mV- Temperature Meter

Precision hand-held pressure indicator Model CPH6400

[ Capture Hoods. What is a capture hood?

CO Analyzer. The Value Leader TM

Dräger UCF 8000 NFPA Certified Thermal Imaging Camera

Data logger systems from ROTRONIC

PHOENIX CONTACT - 05/2007

Data Sheet Version 1.0

Programming unit VIATOR HART modems Model PU-H

Guardian2 Multi-Agent Monitoring Station

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

Waterproof Construction. Notepad Function. Automatic Datalogging. Automatic Calibration. Good Laboratory Practices. Serial Interface Port

PM-204A/B. Power Meter. Operation Guide

CombiView DFON Graphical display

H 2. Technical data. S Power & Communication Cables. M07996/Eng Issue 4 Jul 2015

Product Registration. Register your product online by visiting: By registering your product, you can:

SVG3 (Basic Equipment)

WARNING & SAFETY PRODUCTS

Transcription:

Gas detection just got personal Part of the ersonal urveyor range Coloured 'rubber boot' for multi-site or multi-application working (7 colours available) Simple 1-button operation Any combination of (LEL/O 2 /CO/H 2 S) Audible, visual and vibrating alarms Fully certified Internal pump (optional) Lightweight Sensor integrity checking Robust construction Ease of maintenance Auto Bump & Calibration Station Simple user interface Full bump, calibration and charging options Bump/calibration results storage Stand-alone, PC or ethernet options Robust construction Detection, Protection, Innovation Gas Measurement Instruments Ltd GMI. CONFIDENCE WHERE SAFETY IS CRITICAL. Gas Measurement Instruments designs, manufactures and markets a wide range of the highest quality proven personal portable and fixed gas monitoring systems. GMI is an international brand with a worldwide network of distributors and dedicated service centers ensuring fast and effective turnaround on instrument calibration and repair. Our uncompromising engineering excellence, established in over half a century of leadership, enables us to meet the exacting demands of industries where safety is critical. By building and maintaining strong relationships with our customers, GMI understands the unique challenges of the diverse markets we serve. Today, our proud heritage of pioneering gas leak monitors and detectors is shaping the future of GMI. an company

The PS200 Series detects all possible combinations of LEL, O 2, CO, H 2 S, including single gas detection. In addition to displaying all gas readings simultaneously, the user can also initiate a manual bump test anytime. The PS200 accessory pack includes the following as standard: USB Charging/Comms Cable, Universal Power Plug, User CD- ROM, Quick Operating Instructions. Tubing (3m) complete with a Quick Connector is also supplied as standard with pumped instruments. Features Green / Red Visual Alarms TECHNICAL SPECIFICATION Size: 121 x 59 x 32mm (4.8 x 2.3 x 1.3 ) Weight: 230g (8oz) with pump 215g (7.6oz) without pump Temperature: -20 o C to +50 o C (-4 o F to 122 o F) Humidity: 0 to 95% R.H non-condensing Alarms: Highly visible flashing LED, piercing >90dB audible Display: Green and red LCD backlight display Datalogging: Timed: 24 hours of timed logs at 1 log per minute Session: Minimum of 180 logs Calibration: Minimum of 8 calibration logs Bump Logs: Minimum of 180 logs Battery: Lithium Ion rechargeable battery Run Time > 14 hrs (diffusion) Charging Time < 4 hrs Enclosure: High impact rubberized polycarbonate case Drop Test: 3m (10ft) IP Rating: IP67 (Dust-tight and waterproof to 1m) Response LEL = 10 secs (IEC 60079-29-1) Times (T 90 ): O 2 = 10 secs (BSEN 50 104) CO = 25 secs H 2 S = 35 secs Approvals: IEC Ex ia d IIC T4 Gb ATEX Ex II 2 G Ex ia d IIC T4 CSA Class 1 Div 1 Groups A,B,C,D, T4 c us Class 1, Zone 1 EX ia d IIC T4 MED (0038/YY) - Module B & E 0518 Warranty: 2 years as standard Red display in alarm conditions On/Off button Actual Size Sensors (x3) Audible Alarm Configurable calibration options Charging & communication contacts (x4) Sample inlet nozzle Configurable bump options

Automatic Bump Testing and Calibration To complement the Personal Surveyor product line, GMI has developed a compact, robust and easy to use Auto Bump & Calibration Station that can provide full bump and calibration options. Data transfer is facilitated using a USB memory stick with Standalone software that is simple to set up and customise based on end users specifications. Standalone, PC, and ethernet versions are available. Standalone By adding the Auto Bump & Calibration Station to your PS200 package, data can be easily retrieved using specific software in a userfriendly time logged format. This gives you the ability to create and print your personalised calibration certificate. PC Allows easy configuration (bump test or calibration) of Auto Bump & Calibration Station and allows all results to be automatically stored to a database on the PC. The stored results can be easily viewed and calibration certificates produced. The history of all results can be easily viewed and reports of instruments can be easily compiled. Ethernet Same as PC except multiple units can be connected to a network allowing one PC to control and receive data. Datalogging Datalogging is a standard feature of all PS200 Series instruments and the internal memory can hold up to 180 bump test and session logs, 8 calibration logs and 24hrs of timed logs at 1 log per minute. Simple data extraction from instrument to PC using USB cable supplied. Upgrade your package to include PC datalogging software. AUTO BUMP & CALIBRATION STATION TECHNICAL SPECIFICATION Size: 200 x 140 x 135mm (7.9 x 5.5 x 5.3 ) Weight: 1.2kg (43oz) Interfaces: Standalone /USB /Ethernet LED Indicators: Power (Green) /Testing (Yellow) /Pass (Green) / Fail (Red) Testing Time: Bump Test 60 secs Calibration Test 90 secs Data Storage: >6000 Bump & Calibration results Power Supply: 12V dc, 2A Operating Temperature: -10 o C to 40 o C (14 o F to 104 o F) Gas Ports: 3 (Air, Combi Gas & Exhaust) Contact GMI for other combinations SENSOR SPECIFICATIONS GAS RANGES INCREMENTS SENSOR TYPE LEL 0-100% LEL 1% LEL Catalytic Bead O2 0-25% 0.1% Electrochemical CO 0-1000ppm 1ppm Electrochemical H2S 0-100ppm 1ppm Electrochemical

Simple User Maintenance High impact rubberised polycarbonate case (Part No. 64244) LEL sensor (Part No. 64825) Flexi PCB (Part No. 64290) Robust belt clip (Part No. 64242) Display (Part No. 64327) Sensor grill (with captive screw) (Part No. 64240) Hydrophobic filter (Part No. 64254) Sample quick connect (Part No. 64241) Sample inlet filter (Part No. 64084) O 2 sensor (Part No. 64066) Dual Toxic (CO/H 2S) sensor (Part No. 64067) Pump Assembly (optional) (Part No. 64255) Sounder (Part No. 64322) ORDERING INFORMATION AND ACCESSORIES Accessories supplied with the instrument 64260 USB Charging / Comms Cable 64247 Universal Power Plug (Mains USB) 64190 User CD-ROM (Incl. Handbook) 64172 Quick Operating Instructions 64118 3m. PVC sample line with Quick Connector (pumped only) RECOMMENDED SPARE PARTS 64254 Hydrophobic Filter 64084 Sample Inlet Filter 64825C LEL sensor 64066 O 2 sensor 64067 Dual Toxic CO/H 2 S Sensor 64176 CO sensor 64128 H 2 S sensor 64255 Pump Assembly ADDITIONAL ACCESSORIES 64303 Rubber Boot (Colour options:- black, grey, yellow, red, orange, blue, green) 66123 Hand Aspirator 66478 Hand Aspirator (c/w 10 ft. tubing) 66112 Sample Line Extender 66485 In-Line Hydrophobic Filter Assy 66545 64100 64248 64138 Ball Float Rugged Carry Case Charging Accessories In-Vehicle Charging Adaptor (12V/24V USB) 5 Way Multi-Charger Automatic Bump & Calibration 64052 Auto Bump & Calibration Station (6mm. fittings & incl. PSU and USB stick with Standalone software) 64052Q Auto Bump & Calibration Station (1/4 in. fittings & incl. PSU and USB stick with Standalone software) 99553 flexical Plus software for PC 99118 Demand Flow Regulator 64265 Tubing with 6mm Push Fit Connector Manual Bump & Field Calibration Kit 64051 Manual Bump Kit (no power required) (c/w Combi Test Gas 99146, Direct Flow Regulator, tubing & sample line connector) Gas Kits for Auto Bump & Calibration Station 99146 Combi Test Gas Cylinder (2.5% CH 4, 500ppm CO, 50ppm H 2 S, 18% O 2, balance N 2 ) 64060 64060Q Test Gas Kit (6mm fittings) (Combi Test Gas 99146, Demand Flow Regulator 99118 c/w 6mm tubing) Test Gas Kit (1/4 in Fittings) (Combi Test Gas 99146, Demand Flow Regulator part no. 99118 c/w 1/4 tubing) Software 64197 Data downloading CD-ROM (c/w Handbook) 64184 Auto Bump & Calibration Station USB Flash Drive (c/w Handbook) Documentation 64193 Configuration & Field Calibration Handbook (CD-ROM)

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.