Diagnostics (Logical)

Similar documents
Diagnostics (Logical) Diagnostics (Physical)

TURCK Modular Industrial I/O PROFIBUS -DP Products

Diagnostics (Logical) Diagnostics (Physical)

THE FULL RANGE FOR PROCESS AUTOMATION. This document provided by Barr-Thorp Electric Co., Inc

TURCK Industrial I/O DeviceNet Products

Diagnostics (Physical)

THE FULL RANGE FOR PROCESS AUTOMATION. This document provided by Barr-Thorp Electric Co., Inc

TURCK Industrial Connectivity Products

BL compact fieldbus station for DeviceNet 2 Analog Inputs for Current or Voltage and 2 Analog Outputs for Voltage BLCDN-4M12S-2AI2AO-VI

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

TURCK Industrial Wiring Solutions

BL compact fieldbus station for DeviceNet 4 Analog Outputs for Voltage BLCDN-4M12S-4AO-V

Analog Modules AS-i IP65, M12

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Analog Modules AS-i, IP67, M12

multibox picofast Junction Boxes, 4-port, 3-Pin

TURCK Industrial Connectivity Products

BL compact Fieldbus Station for DeviceNet 4 Analog Current Outputs BLCDN-4M12LT-2AO-I-2AO-I

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

Connect AS-I Gateways to PC for Configuration and Troubleshooting

Type code. BLCEN-8M12LT-4AI-VI-8XSG-P Ident-No Nominal system voltage 24 VDC. Nominal current Vo Max. current Vo

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

NEW. TURCK Inductive Sensors - Specialty DS20

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

BL compact Multiprotocol Station for Industrial Ethernet 2 Analog Pt and Ni Sensor Inputs BLCEN-2M12MT-2AI-PT

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

BL compact Multiprotocol Station for Industrial Ethernet 8 Analog Current or Voltage Inputs BLCEN-8M12LT-4AI-VI-4AI-VI

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

PCB AS-i modules, board based solutions

IP 69K M12 I/O ports LEDs indicating status and diagnostics

IP 69K M12 I/O ports LEDs indicating status and diagnostics

Digital Modules AS-i in IP20, 22,5 mm

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Digital Modules AS-i, IP67, M12

IDC Field Wireable eurofast & picofast Connectors

Installation Instructions Temperature transmitter TAA /00 06/2011

Temperature Switches

On-Machine Modular I/O

AS-i Safety Input Modules (M12), IP67

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

I/O Modules Active Stand-Alone: Interbus

07. har-link INTERFACE CONNECTORS

Bulletin 871D Cylinder Position Inductive Style

AS-i 3.0 Motor modules

Seriplex. System throughput time is 0.4 msec for 32 sensors plus 32 actuators (5 msec for 510 I/O)

BL compact Multiprotocol Station for Industrial Ethernet 8 Analog Thermocouple Inputs BLCEN-8M12LT-4AI-TC-4AI-TC

Cube67 - Modular I/O station

Rotary Measurement Technology Absolute Encoders, Singleturn

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

picofast 4 - Branch Molded Junctions, Standard Wiring

DieGuard Protection Sensing

Miniature Inductive Prox TL-W

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

TURCK Modular Industrial I/O System

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H

Intelligent Temperature Sensors

07. har-link Interface Connectors

Rotary Measurement Technology Absolute Encoders, Multiturn

IB080QM65VA3 Part Number

ABSOLUTE ROTARY ENCODER INTERBUS

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

SensaGuard. Description. Features. Benefits. Specifications

Technical data. General specifications. Indicators/operating means

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

3.4. Inductive Proximity Sensors. Contents Description. Global Proximity Sensors. Global Proximity Sensors...

Specifications. Functional Safety Data Note: For up-to-date information, visit Certifications.

iologik 4000 Series (M) Modules

ABSOLUTE ROTARY ENCODER INTERBUS

Data Sheet for Linear Sensors

Faults on the system Proximity switch connection technology:

BL compact Multiprotocol Station for Industrial Ethernet 16 Digital PNP Inputs BLCEN-16M8LT-8DI-P-8DI-P

BL67 electronic module 4 analog inputs for current/voltage BL67-4AI-V/I

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features

Linear Measurement Technology Draw Wire Mechanics with Encoder or Analog Sensor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Angular Position Technology

AS-i Safety Analog Input Module, IP20

Inductive proximity switches with long operating distance, series 500

PROFIBUS Contents. Product Topology Profibus I/O Blocks Cordsets Field Attachables Accessories

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Magnetically Actuated Safety Interlock Switches

ProfiPro Distributed PROFIBUS I/O Modules User Manual

In-Cabinet Block I/O. FDP20 PROFIBUS digital I/O. FEN20 Ethernet digital block I/O. FDN20 DeviceNet block I/O. FAS20 AS-interface digital I/O

File (19 inches) for RS3 FIC I/Os (AI/AO) migration toward a new system

Photoelectric Sensors E3F2

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

iologik E1200H Series

Sensor boxes SRBG Key features

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Cube20. Application-oriented. Installation-friendly. Efficient

Thread length (overall length) material

Chemical Resistant Inductive Prox

mobile data carrier TW-R16-B128 Phone: Fax: Web: -

NO - NPN PSC10-30GI70-E PSC10-30GI70-E-V1 NO - PNP PSC10-30GI70-E2 PSC10-30GI70-E2-V1

Transcription:

Input Station Rugged, Fully Potted Stations IP 67 Protection Flat and Round Cable Support AS-I Version 2.1 FAS4-S0400 Electrical Operating Current: <75 ma plus input currents (from AS-I) Sensor Current: <200 ma sum of all inputs (from AS-I) Inputs: AS-I power supply Mechanical Operating Temperature: -25 to +70 C (-25 to +158 F) Protection: IEC IP 67 Vibration: 50 g @ 10-500 Hz Material Connectors: Nickel-plated brass Housing: Nylon 6 (Logical) I/O faults are reported via the AS-I peripheral fault bit. AS-I eurofast Female 1. = AS-I+ 2. = NC 3. = AS-I 4. = NC 4-Pin

Inputs Data Part Number AS-I Version Addressing Input Count Connectors FAS4-S0400 2.1 AB 4 0-3 S 1 PNP X 0.A-E Inputs per Connector Sensor Group Wire-Break Detection Slave Profile Input/Output Connectors S Mating cordset: RK 4.4T-*-RS 4.4T AS-interface

Input/Output Stations Rugged, Fully Potted Stations IP 67 Protection Flat and Round Cable Support AS-I Version 2.1 FAS4-CSG44 FAS4-CSG43* * Not UL Electrical Operating Current: <50 ma plus I/O currents (from AS-I) I/O Current: <200 ma sum of all inputs and outputs(from AS-I) (FAS4-CSG43) <400 ma sum of all inputs and outputs from AS-I (FAS4-CSG44) Inputs: AS-I power supply Outputs: AS-I power supply Mechanical Operating Temperature: -25 to +70 C (-25 to +158 F) Protection:IEC IP 67 Vibration: 50 g @ 10-500 Hz Material Connectors: Nickel-plated brass Housing: Nylon 6 (Logical) I/O faults are reported via the AS-I peripheral fault bit AS-I eurofast Female 1 = AS-I+ 2 = NC 3 = AS-I 4 = NC 4-Pin

Inputs Outputs Data Part AS-I Version Addressing In Count Connector Sensor Group FAS4-CSG44 2.1 Single 4 CS PNP X 4 CS 0.4 A * 7.F-E FAS4-CSG43 2.1 AB 4 CS PNP X 3 CS 0.2 A * 7.A-E * Total current is shared by all I/O on station Wire-Break Detection Output Current Wire-Break Detection Slave Profile Input/Output Connectors CS Mating cordset: RK 4.4T-*-RS 4.4T Splitter: VB2-RS 4.4T-1/2RK 4.4T-*/*/S651 AS-interface

Input/Output Stations Rugged, Fully Potted Stations IP 67 Protection Auxiliary Powered Outputs AS-I Version 2.1 FAS4-CSG44-A FAS4-CSG43-A* * Not UL Electrical Operating Current: <50 ma plus Input currents (from AS-I) I/O Current: <200 ma sum of all inputs from AS-I (FAS4-CSG43-A) <400 ma sum of all inputs from AS-I Power (FAS4-CSG44-A) Output Current: <700 ma per output (from Aux. power) Inputs: AS-I power supply Outputs: AS-I power supply Mechanical Operating Temperature: -25 to +70 C (-25 to +158 F) Protection: IEC IP 67 Vibration: 50 g @ 10-500 Hz Material Connectors: Nickel-plated brass Housing: Nylon 6 (Logical) I/O faults are reported via the AS-I peripheral fault bit AS-I eurofast Female 1. = AS-I+ 2. = NC 3. = AS-I 4. = NC 4-Pin Aux. Power eurofast Female 1. = V AUX + 2. = NC 3. = V AUX - 4. = NC 4-Pin

Inputs Outputs Data Part Number AS-I Version Addressing In Count Connectors Sensor Group FAS4-CSG44-A 2.1 Single 4 0-3 CS PNP X 4 0-3 CS 0.7 A 7.F-E FAS4-CSG43-A 2.1 AB 4 0-2 CS PNP X 3 0-2 CS 0.7 A 7.A-E Wire-Break Detection Output Connectors Current Wire-Break Detection Slave Profile Input/Output Connectors CS Mating cordset: RK 4.4T-*-RS 4.4T Splitter: VB2-RS 4.4T-1/2RK 4.4T-*/*/S651 AS-interface

Input/Output Stations Rugged, Fully Potted Stations IP 67 Protection Auxiliary Powered Outputs AS-I Version 2.1 FAS4-S0202G-A Electrical Operating Current: <50 ma plus Input currents (from AS-I) Input Current: <200 ma sum of all inputs (from AS-I) Output Current: <400 ma sum of all outputs (from Aux. power) Inputs: AS-I power supply Outputs: AS-I power supply Mechanical Operating Temperature: -25 to +70 C (-25 to +158 F) Protection:IEC IP 67 Vibration: 50 g @ 10-500 Hz Material Connectors: Nickel-plated brass Housing: Nylon 6 (Logical) I/O faults are reported via the AS-I peripheral fault bit AS-I eurofast Female 1 = AS-I+ 2 = NC 3 = AS-I 4 = NC 4-Pin Aux. Power eurofast Female 1 = V AUX + 2 = NC 3 = V AUX - 4 = NC 4-Pin

Inputs Outputs Data Part Number AS-I Version Addressing In Count Connectors Sensor Group FAS4-S0202G-A 2.1 AB 2 2-3 S PNP X 2 0-1 G 0.4 A B.A-E Wire-Break Detection Output Connectors Current Wire-Break Detection Slave Profile Input/Output Connectors S G Mating cordset: RK 4.4T-*-RS 4.4T Mating cordset: RK 4.4T-*-RS 4.4T AS-interface

Output Station Rugged, Fully Potted Stations IP 67 Protection Auxiliary Powered Outputs AS-I Version 2.1 FAS4-S0003G-A Electrical Operating Current: <50 ma (from AS-I) Output Current: <700 ma per output (from Aux. power) Outputs: Auxiliary power supply Mechanical Operating Temperature: -25 to +70 C (-25 to +158 F) Protection: IEC IP 67 Vibration: 50 g @ 10-500 Hz Material Connectors: Nickel-plated brass Housing: Nylon 6 (Logical) I/O faults are reported via the AS-I peripheral fault bit AS-I eurofast Female 1 = AS-I+ 2 = NC 3 = AS-I 4 = NC 4-Pin Aux. Power eurofast Female 1 = V AUX + 2 = NC 3 = V AUX - 4 = NC 4-Pin

Outputs Data Part Number AS-I Version Addressing Output Count FAS4-S0003G-A 2.1 AB 3 0-2 GS 0.7 A 8.A-E Connectors Current Wire-Break Detection Slave Profile Output Connectors GS Mating cordset: RK 4.4T-*-RS 4.4T AS-interface

AS-I Conduit Adapter Slave Slave Right in Conduit Fits Crouse-Hinds Bodies Ideal Where Conduit Is Required Bus Powered I/O BCS-ASI-CSG22 Electrical Operating Current: <200 ma including all I/O current (from AS-I) Output Current: <80 ma sum of all outputs (from AS-I) Inputs: AS-I power supply Outputs: AS-I power supply Mechanical Operating Temperature: -25 to +70 C (-25 to +158 F) Protection:IEC IP 67 Material Connectors: Nickel-plated brass (stainless steel available on request) Housing: Nylon (other materials available on request) (Logical) I/O faults are reported via the AS-I peripheral fault bit AS-I Connector

Inputs Outputs Data Part Number AS-I Version Addressing Input Count Connectors Group BCS-ASI-CSG22 2.1 AB 2 0-1 CS PNP X 2 0-1 CS 80 ma B.A-E Wire-Break Detection Output Count Connectors Current OCD Slave Profile Input/Output Connectors CS Mating cordset: RK 4.4T-*-RS 4.4T AS-interface

Analog Input Stations Analog on AS-I IP 20 for In-the-Cabinet Powered by AS-I or Auxiliary Supply ASI-AI-2 BW1345 ASI-AI-2 BW1447 ASI-AI-2A BW1726 Electrical Operating Current: <80 ma (from AS-I) Sensor Current: <40 ma per input Inputs: AS-I or Auxiliary supply, selectable by user BW1345, BW1447 default sensor current from AS-I BW1726 default sensor current from auxiliary supply Mechanical Operating Temperature: 0 to +70 C (+32 to +158 F) Protection: IP 20 (Logical) I/O errors are indicated by the AS-I peripheral fault bit (v2.1 and higher) (Physical) One LED indicates an I/O fault (over or under-range for each channel) LEDs to indicate status of AS-I communication and power supply

Inputs Data Part Number AS-I Version Addressing In Count ASI-AI-2 BW1345 2.1 Single 2 4 to 20 ma/0 to 10 V X X X 7.3-D 1 ASI-AI-2 BW1447 2.1 Single 2 4 to 20 ma/0 to 10 V X X X 7.3-D 1 ASI-AI-2A BW1726 2.1 Single 2 4 to 20 ma/0 to 10 V X X X 7.3-D 1 Group OCD Slave Profile Map Input/Output Connectors AS-interface I/O Data Map 1 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 In 0 Analog Value (LSB) 1 Analog Value (MSB) * Notes:Data map applies to each channel of analog data used. Resolution is 1 ua/bit in current mode and 1 mv/bit in voltage mode. BW1345 and BW1726 use range of 4000...20000 for current and 0...10000 for voltage inputs. BW1447 uses range of 0...27648 (0x0000...0x6C00) for compatibility with existing Siemens based programs.

Analog Input Stations Analog on AS-I IP 65 Protection Powered by AS-I or Auxiliary Supply ASI-AI-2 BW1232 ASI-AI-2 BW1233 Electrical Operating Current: <80 ma from AS-I Sensor Current: <40 ma per input Inputs: AS-I or Auxiliary supply, selectable by user Mechanical Operating Temperature: 0 to +70 C (+32 to +158 F) Protection: IP 65 Connections: Cage clamp block through gland fittings Material Housing: Plastic (Logical) I/O errors are indicated by the AS-I peripheral fault bit (v2.1 and higher) (Physical) LEDs indicate I/O faults (over- and under-current or voltage for each channel) LEDs to indicate status of AS-I communication and power supply

Inputs Data Part Number AS-I Version Addressing In Count ASI-AI-2 BW1232 2.1 Single 2 4 to 20 ma X X X 7.3-D 1 ASI-AI-2 BW1233 2.1 Single 2 0 to 10 V X X X 7.3-D 1 Group OCD Slave Profile Map Input/Output Connectors 1 1 V AUX + 2 Signal1+ 3 V AUX - 4 Signal1-5 Shield 6 Shield 7 V AUX + 8 Signal0+ 9 V AUX - 10 Signal0-11 FG (Function Gnd) 12 FG (Function Gnd) AS-interface I/O Data Map 1 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 In 0 Analog Value (LSB) 1 Analog Value (MSB) Note: Data map applies to each channel of analog data used. Resolution is 1 ua/bit in current mode and 1 mv/bit in voltage mode. BW1232 range of values is 4000-20000. BW1233 range of values is 0-10000. AS-I connections are made via standard AS-I base modules (ASI-BM BW1180, ASI-BM BW1182) if I/O is powered by AS-I or auxiliary supply base modules (ASI-BM BW1181, ASI-BM BW1183) if I/O is powered by auxiliary power (see pages E105-106).

Analog Input Stations Analog on AS-I IP 20 for In-The-Cabinet Powered by AS-I or Auxiliary Supply Voltage, Current or Temperature Inputs ASI-AI-4 BW1364 ASI-AI-4 BW1365 ASI-AI-4PT100 BW1368 Electrical Operating Current: <80 ma from AS-I Sensor Current: <40 ma per input (BW1364 and BW1365) Inputs: AS-I or Auxiliary supply Mechanical Operating Temperature: 0 to +70 C (+32 to +158 F) Protection: IP 20 (Logical) I/O errors are indicated by the AS-I peripheral fault bit (v2.1 and higher) (Physical) LEDs indicate faults for each input LEDs to indicate status of AS-I communication and power supply

Inputs Data Part Number AS-I Version Addressing In Count ASI-AI-4 BW1364 2.1 Single 4 1 4 to 20 ma X X X 7.3-E 1 ASI-AI-4 BW1365 2.1 Single 4 1 0 to 10 V X X X 7.3-E 1 ASI-AI-4PT100 BW1368 2.1 Single 4 2 RTD X X X 7.3-5 1 Group OCD Slave Profile Map Input/Output Connectors AS-interface I/O Data Map 1 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 In 0 Analog Value (LSB) 1 Analog Value (MSB) Note: Data map applies to each channel of analog data used. Resolution is 1 ua/bit in current mode, 1 mv/bit in voltage mode and 0.1 C in temperature mode (range is -200 to +850 C).

Temperature Input Stations Analog on AS-I IP 20 for In-The-Cabinet Powered by AS-I or Auxiliary Supply Relay Output Option ASI-AI-4PT100 BW1254 ASI-AI/DO-2RTD/2R BW1552 Electrical Operating Current: <80 ma from AS-I Inputs: AS-I or Auxiliary supply (BW1368 is only powered from AS-I) Mechanical Operating Temperature: 0 to +70 C (+32 to +158 F) Protection: IP 65 Connections: Cage clamp block through gland fittings Material Housing: Plastic (Logical) I/O errors are indicated by the AS-I peripheral fault bit (v2.1 and higher) (Physical) LEDs indicate faults for each input LEDs to indicate status of AS-I communication and power supply

Inputs Outputs Data Part Number AS-I Version Addressing In Count Group ASI-AI-4PT100 BW1254 2.1 Single 4 1 RTD X X X 0 7.3-E 1 ASI-AI/DO-2RTD/2R BW1552 2.1 Single 2 2 RTD X X X 2 2 0.5 A 7.3-D 1 OCD Out Count Current Slave Profile Map Input/Output Connectors 1 2 1 V+ 2 Signal 0-3 V0-4 V+ 5 Signal 1-6 V 1-7 V+ 8 Signal 2-9 V 2-10 V+ 11 Signal 3-12 V 3-1 V+ 2 Signal 0-3 V0-4 V+ 5 Signal 1-6 V 1-7 O 0 (NO) 8 O 0-9 O 0 (NC) 10 O 1 (NO) 11 O 1-12 O 1 (NC) AS-interface I/O Data Map 1 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 In 0 Analog Value (LSB) 1 Analog Value (MSB) Note: Data map applies to each channel of analog data used. Resolution is 0.1 C/bit in RTD mode (range is -200 to +850 C). For BW1552 relay outputs are set via parameter bits 2 and 3. AS-I connections are made via standard AS-I base modules (ASI-BM BW1180, ASI-BM BW1182) if I/O is powered by AS-I or auxiliary supply base modules (ASI-BM BW1181, ASI-BM BW1183) if I/O is powered by auxiliary power (see pages E105-106).