Raritan Secure Switch Administrator Guide

Similar documents
Owner s Manual. Secure KVM Switches, NIAP Protection Profile Version 3.0

Owner s Manual. DVI/USB + Audio & Peripheral Sharing KVM Switch

BIG BUTTON PHONE WITH ONE TOUCH DIALING AND

AUDIO DELAY BOX WITH MICROPHONE INPUT AD-100M. Instruction manual.

VS-1601.book Page i Tuesday, January 16, :15 PM User Manual VS1601

User s guide for Xtenda TM

QIT600F1 USER'S GUIDE

DSS Console and DSS Console for Attendant for Digital Super Hybrid Systems. Reference Guide ANSWER RELEASE

Owner s Instruction Manual

MultiPlex 15 Touch Screen. User s Manual

WARNINGS AND PRECAUTIONS... 3 PACKING LIST... 5 FRONT PANEL... 5 REAR PANEL... 6 MENU SETTINGS... 7 EXAMPLE SETUP SPECIFICATIONS...

Network Camera. Quick Guide DC-B1203X. Powered by

Big button Speakerphone MODEL: FC-8814

Advanced 8-Port DisplayPort Secure KVM Switch

PICTURE PHONE WITH ONE TOUCH DIALING MODEL: FC-0613

Administrative Guide. Intended Audience This document is intended for the following professionals: System Administrators/IT Managers.

CANTEEN 6000 Portable Battery Pack NAP-30. Instruction Manual Please read carefully before use and keep for future reference.

Owner s Manual. 4-Port HDMI/USB KVM Switch with Audio and Peripheral Sharing. Model: B004-HUA4-K

Advanced 2/4-Port DisplayPort Secure KVM Switch

FUTURE CALL. Future Call Model FC-1204 Totally Hands Free Voice Activated Dialing and Answering Telephone OWNER S MANUAL AND OPERATING INSTRUCTIONS

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

ADVANCED 4/8-PORT SECURE KM SWITCH

ADVANCED 4/8 PORT DVI-D MATRIX SECURE KVM SWITCH

Document ID: DOC-IPG-2004 Revision: 1.10 Release Date: December 13th, Advanced 2/4-Port DVI-I Secure KVM Switch

345 Encinal Street Santa Cruz, CA

VOICE-ACTIVATED INTERCOM SYSTEM

DC-D4213RX DC-D4213WRX

FUTURE CALL USER MANUAL PICTURE PHONE WITH SPEAKERPHONE MODEL: FC-1007 SP / PD

c724e.book Page i Friday, January 27, :26 AM USER MANUAL CS-72E CS-74E

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

Quick Reference Guide

Advanced 4/8-Port DVI-D Matrix KVM

Advanced 4/8 Port Secure KM Switch

VISTA DVI INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281) DVI USB KVM Switch

b. Time Setting c. Volume Setting d. Backlight Setting e. Sleep Setting f. Pin Setting g. Joystick Calibration...

Network Camera. Quick Guide DC-T3243HRX. Powered by

User Manual CS-1762 CS-1764

Advanced 2/4/8/16-Port DVI-I Secure KVM

2/4-Port VGA Switch with Audio VS0201 / VS0401 User Manual

ADVANCED 1/2/4-PORT DVI-I SECURE KVM SWITCH

SPK User Manual. 900MHz Wireless Stereo Headphones INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Advanced 2/4 Port DisplayPort to HDMI Secure KVM

4-Port Single-head Secure Pro DVI-D KVM Switch with KB/Mouse USB emulation, CAC and Preview Screen

1. Introduction Features Checking List Installation Install the Pedestal Connect Your Monitor to Computer...

7-Port Fast Charging Station NAP Instruction Manual Please read carefully before use and keep for future reference.

Hospitality Telephones User Guide

Network Camera. Quick Guide DC-D1223WX. Powered by

Advanced 4-Port DVI-I Secure KVM Switch

USER GUIDE TABLE OF CONTENTS TECHNICAL SPECIFICATIONS WHAT S IN THE BOX? SECURITY FEATURES SECURE KVM SWITCH FRONT AND REAR INSTALLATION

Advanced 2/4/8-Port DisplayPort Secure KVM Switch

DC-D2212R / DC-D2212WR

ENG. LCD Monitor Series Prestigio P TFT Active Matrix LCD Panel User s Manual. Prestigio P1910 1

Marshall Lynx LCD Universal Monitors

Version 1.0 March 2014 OLC 10.1

UEH4002A 4-port USB 2.0 CAT 5 Extender User Manual

Quick Guide. ENC-H Video Encoder XX

8-Port True 4K HDMI Switch VS0801HB User Manual

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

2/4-Port VGA Switch with Audio VS0201 / VS0401 User Manual

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

OWNER S INSTRUCTION MANUAL

Hospitality Telephones User Guide

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Network Camera. Quick Guide DC-S1283WRX. Powered by

Prestigio P371 Users manual

INDOOR/OUTDOOR SPEAKER WITH BLUETOOTH WIRELESS TECHNOLOGY PART NUMBER PA360 EXPERIENCE 360 OF SOUND. pulseaudio1.com vanco1.com

DVI HDBaseT KVM Extender with ExtremeUSB CE610A User Manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Owner s Manual. 4-Port KVM Switch with Audio, OSD & Peripheral Sharing. Model: B006-VUA4-K-R.

Table of Contents. Federal Communications Commission (FCC) Statement...2

Vista LC DVI. Installation and Operation Manual. 12-Port DVI/USB/Audio KVM Switch Stancliff Road Houston, Texas 77099

HARD DRIVE EXPANSION BAY DESIGNED FOR THE DIGIMERGE BLADE

Manual Version: V1.00. Video Decoder Quick Guide

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

EVO-TM2A EVO-TM2B Touch Screen Monitor

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size

Network Camera. Quick Guide DC-D3C33HRX. Powered by

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Assurance Activities Report for Raritan Secure KVM Switches

Installation and Operations Manual

Blonde On Blonde OWNER S MANUAL SWR SCOTTSDALE, AZ USA

ShoreTel IP Phone 655. Quick Install Guide & Warranty

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

CR6S Stereo Micro Crush

TL-PA4010 AV600 Powerline Adapter

Safety and Maintenance You can use your Tablet PC under a wide range of environmental conditions. However, to ensure long use and continued high

DC-D3233RX-N / DC-D3233X-N

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN

VC-B10U HD Camera (USB 3.0 Camera) Installation Manual - English

Neets Switching Relay - 2. Installation manual

VE2812UST / VE2812EUT HDMI & VGA HDBaseT Transmitter with US / EU Wall Plate User Manual

8780 Line Powered Caller ID Speaker Phone INSTRUCTION MANUAL

4170 POS System Installation Guide

USB Audio Converter. Installation and Operation Manual. USB to Analog Audio Converter Stancliff Road Houston, Texas 77099

Card Enrollment Station. User Manual UD05870B

Startup Guide C01

ISDN 8510T Voice Terminal Instructions for Changing the EPROM

USER MANUAL. For XLCD17-LED XLCD19-LED

Transcription:

Raritan Secure Switch Administrator Guide Release 1.0 Copyright 2018 Raritan, Inc. SecureSwitch_admin-0A-v1.0-E January 2018 255-80-0052-00 RoHS

Raritan Secure Switch Series Administrator Guide version 1.0 This document contains proprietary information that is protected by copyright. All rights reserved. No part of this document may be photocopied, reproduced, or translated into another language without express prior written consent of Raritan, Inc. Copyright 2018 Raritan, Inc. All third-party software and hardware mentioned in this document are registered trademarks or trademarks of and are the property of their respective holders. FCC Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential environment may cause harmful interference. VCCI Information (Japan) Raritan is not responsible for damage to this product resulting from accident, disaster, misuse, abuse, non-raritan modification of the product, or other events outside of Raritan's reasonable control or not arising under normal operating conditions. If a power cable is included with this product, it must be used exclusively for this product. 1

Contents Chapter 1 Introduction... 1 Overview... 1 Administrative Functions... 1 Chapter 2 Hardware Setup... 2 Before You Begin... 2 Tampering prevention and detection... 2 Always use qualified and authorized peripheral devices... 3 Secure Installation... 3 Secure Administrative Operation... 4 Chapter 3 Operation... 5 Powering On... 5 Manual Switching... 6 LED Display... 6 Chassis Intrusion Detection... 7 Administrator Functions... 8 Appendix... 14

ATTENTION If the tamper-evident seals is missing or peeled, avoid using the product and contact your dealer. If all your front panel LEDs flash continuously, or the switches enclosure appears breached, avoid using this product and contact your dealer. This Secure Switch is equipped with active always-on chassis intrusion detection security. Any attempt to open the enclosure will permanently damage, disable the switch, and void the warranty. Image of Tamper-evident seal here About This Administrator Guide This Administrator Guide is intended for authorized Administrator. This Administrator Guide is provided to help authorized Administrator to audit logs and configure the RARITAN Secure Switch. To maximize security, Administrator is advised to audit logs/events record and the Secure Switch configuration on a routine base. This Administrator Guide covers the following Secure Switch s Configuration PC Video Connection Console Video Connection CAC Support 2-Port 4-Port DVI DVI w/ CAC Feature RSS-102C RSS-104C w/o CAC Feature RSS-102 RSS -104

Raritan Secure Switch Series Administrator Guide version 1.0 Chapter 1 Introduction Overview The Raritan Secure Switch series is NIAP-certified and compliant with NIAP PP 3.0 (Protection Profile for Peripheral Sharing Switch version 3.0) requirements, satisfying the latest security requisites set by the U.S. Department of Defense for peripheral sharing switches. Compliance ensures maximum information security while sharing a single set of HIDs (keyboards, mouse, speakers, and CAC Reader) between multiple computers. Conformity with Protection Profile v3.0 certifies that other USB peripherals cannot be connected to the console ports of the Raritan Secure Switch, and that only a keyboard and mouse are accommodated, therefore providing high-level security, protection and safe-keeping of data. The Raritan Secure Switch hardware security includes tamper-evident tape, chassis intrusion detection, and tamper-proof hardware, while software security includes restricted USB connectivity non HIDs (Human Interface Devices) are ignored when switching an isolated channel per port that makes it impossible for data to be transferred between secure and unsecure computers, and automatic clearing of the keyboard and mouse buffer when switching port focus. By combining physical security with controlled USB connectivity and controlled unidirectional data flow from devices to connected computers only, the Raritan Secure Switch series gives you the means to consolidate multiple workstations of various security classification levels with one keyboard, monitor and mouse (KVM) console. Administrative Functions To be complaint with Protection Profile 3.0 while providing higher deployment flexibility, wider product support for new authentication devices, and maximum security, the Raritan Secure Switch supports Administrative Functions. Through secured access, authorized Administrator can audit log data, configure the Secure Switch, and perform configurable device filtering. Note: 1. The National Information Assurance Partnership (NIAP) is a United States government initiative to meet the security testing needs of IT consumers and manufacturers. It is operated by the National Security Agency (NSA) and the National Institute of Standards and Technology (NIST). 2. The Raritan Secure Switch series additionally satisfies Protection Profile version 3.0 for Peripheral Sharing Switch (PSS). 1

Chapter 2 Hardware Setup Before You Begin If the tamper-evident seals are missing or peeled, avoid using the product and contact your Raritan dealer If all your front panel LEDs flash continuously, or the switches enclosure appears breached, avoid using this product and contact your Raritan dealer This Secure Switch is equipped with active always-on chassis intrusion detection security. Any attempt to open the enclosure will permanently damage, disable the switch, and void the warranty. To maximize security and to prevent unauthorized access to Secure Switch, please do change default logon password after your first successful logon. Tampering prevention and detection 1. The Raritan Secure Switch includes Tamper-evident tape to provide visual indications of intrusion to the switches enclosure. If the tamper-evident seal is missing, peeled, or looks as if it s been adjusted, avoid using the product and contact your RARITAN dealer. 2. The Raritan Secure Switch is equipped with Active always-on chassis intrusion detection. If a mechanical intrusion is detected, the Switch will be permanently disabled and the front panel LEDs will flash continuously. If the switches enclosure appears breeched or all the LEDs are flashing continuously, stop using it, remove it from service immediately and contact your dealer. 3. Any attempt to open the switches enclosure will activate the chassis intrusion detection security, which will render it inoperable and void the warranty. 4. The Raritan Secure Switch cannot be upgraded, serviced or repaired. 5. The Raritan Secure Switch is equipped with active always-on chassis intrusion detection security. Never attempt to open the enclosure. Any attempt to open the enclosure will permanently damage and disable the switch. 6. The Raritan Secure Switch contains an internal battery which is non-replaceable. Never attempt battery replacement or open the switches enclosure. 2

Raritan Secure Switch Series Administrator Guide version 1.0 Always use qualified and authorized peripheral devices 1. For security the Raritan Secure Switch supports only standard USB Keyboard/Mouse(or pointing device). Do not connect a wireless keyboard/mouse, or Keyboard/Mouse with internal USB hub or composite device functions to the switch. 2. When connecting a non-qualified keyboard, the keyboard will not function. No keyboard keystrokes will be seen on the screen. 3. When connecting a non-qualified mouse, the mouse will not function. No mouse cursor movement will be seen on the screen. 4. Num Lock LED, Caps Lock LED, and Scroll Lock LED on keyboard will be disabled due to security policy. 5. Special Multi-media keys on keyboard will be disabled due to security policy. 6. For security the Raritan Secure Switch does not support an analogue microphone or line-in audio input. Never connect a microphone to the switches audio output port, including a headset, only standard analogue speakers and headphones are supported. 7. For security the USB CAC Port by Raritan Secure Switch supports by default only authorized User Authentication Device such as USB Smartcard or CAC reader. Do not connect other USB devices to USB CAC Port. Non-qualified or non-authorized USB devices will be rejected. (for administrative configuration, please refer to Administrator Guide and Port Authentication Utility Guide for detail) 8. For security, do not use USB CAC Authentication device or other peripherals that adopt external power source. 9. Always use qualified monitor, when the device is connected with monitor, it will check the monitor s EDID (Extended display identification data). If the check fails, the content will not be displayed on the monitor and rejected. 10. Do not use wireless video transmitters or any docking device. 11. Do not connect any Thunderbolt device to the Secure Switch. Secure Installation 1. Do not attempt to connect or install the following devices to the computers connected to the Raritan Secure Switch: TEMPEST computers; Telecommunication equipment; Frame grabber video cards; Special audio processing cards. 2. Important safety information regarding the placement of this device is provided on page 14. Please review it before proceeding. 3. Before installation, make sure the power sources to all devices connected to the 3

installation are turned off. You must unplug the power cords of any computers that have the Keyboard Power On function. 4. Hot-swapping of console monitor is not allowed. Power off the Secure Switch and the monitor before changing the console monitor. 5. A computer connected to the KVM switch should only be powered on after all of the connections to the device are made (Video, USB and audio). 6. Please refer to the Raritan Secure Switch user manual for hardware installation. Secure Administrative Operation 1. The Raritan Secure Switch Administration function (such as Log data audit and configuration of authentication devices filter) can only be performed by authorized Administrator. 2. To maximize security and to prevent unauthorized access to Secure Switch, please change the default logon password right after your first successful logon. 3. Administrator s Logon session will be terminated if Administrator logs off the session or the KVM is powered off. 4. Please refer to Operation section for detail Administrator functions. 4

Raritan Secure Switch Series Administrator Guide version 1.0 Chapter 3 Operation Powering On When you power on, reset, or power cycle the Raritan Secure Switch, the Raritan Secure Switch will perform a self-test with follow test items to check the unit s integrity and security functions. Firmware integrity Accessibility of internal memory of the micro-controller Key stuck test Anti-tampering test Port isolation test During the self-test All Port LEDs will turn ON and then OFF The KVM focus will be switched to Port 1 when the self-test completes successfully (Port 1 Port LED lights GREEN) Self-test failure In case of self-test failure, the Secure Switch becomes inoperable, with front panel LED combination indicating the potential cause to the failure (such as button jam and KVM integrity) Pre-defined combination of Port LED indicates the cause to the failure. - Button jam: The Port of jammed button port will flash green If all Port LEDs flash, it means KVM tampering detected or integrity issues happened For security, the Raritan Secure Switch becomes inoperable if self-test fails. Please verify your KVM installation, pushbuttons, and power cycle again the Security KVM. If the self-test failure remains, stop using the Raritan Secure Switch immediately, remove it from service and contact your Raritan dealer. Reset the KVM This Administrator function enables the authorized Administrator to reset the KVM configuration to factory default. For actual instructions, please refer to the Reset KVM to Default in the Administrator Functions Section. 5

Manual Switching For increased security, the Raritan Secure Switch offers manual port-switching only. This is achieved by pressing the port selection pushbuttons located on the unit s front panel. Press and release a port selection pushbutton to bring the KVM focus to the computer attached to its corresponding port (see Port ID Numbering, below). To meet maximum security and channel isolation requirements, Keyboard, Mouse, Video, Audio, and USB CAC reader port will be switched together. The Selected Port LED lights GREEN to indicate that the computer attached to its corresponding port has the KVM focus (including Keyboard, Mouse, Monitor, Audio, and CAC reader). The PC that has the port focus should be able to detect the peripherals after port switching. If the PC fails to detect your keyboard, mouse, or CAC card reader, Please verify if you are using qualified Keyboard, Mouse, or CAC Card reader. Please verify if your keyboard, mouse, or CAC reader is a failed device. For USB CAC Card reader (USB authentication device), please make sure the USB CAC cable has been securely connected, and the CAC function is enabled. For USB CAC Card reader port, please contact your administrator to verify if the device you use has been authorized. Port ID Numbering Each KVM port on the Raritan Secure Switch is assigned a port number (1 2 for the 2-Port models; 1 4 for the 4-Port models). The port numbers are marked on the rear of the switch. See Rear View Section in Raritan Secure Switch User Guide, page 7. The port ID of a computer is derived from the KVM port number it is connected to. LED Display In addition to the Power LED, the Raritan Secure Switch has Port LEDs (Online and Selected), and CAC LED that are built into the front panel to indicate Port / CAC reader operating status. These LEDs also serve as the alarm notification for KVM security issues. 6

Raritan Secure Switch Series Administrator Guide version 1.0 LED Power LED Port LED CAC LED Indication The Power LED is on the front panel and lights WHITE to indicate that the KVM switch is powered on. The Port LEDs are located on the front panel to indicate the Port selection or connection status. Online Lights WHITE to indicate that the computer attached to its corresponding port is up and running. Selected Lights GREEN to indicate that the computer attached to its corresponding port has the KVM focus. Note: 1. Port LEDs will flash constantly when a chassis intrusion is detected. See Chassis Intrusion Detection section for details. 2. Port LEDs also indicate the status of the Secure Switch self-test status. See Operation section for further details The CAC LED are located on front panel to indicate CAC reader selection or connection status. Light GREEN when USB authentication device is connected. Lights RED when connected USB device is rejected. (such as USB thumb drive, USB camera etc.) Chassis Intrusion Detection To help prevent malicious tampering with the Raritan Secure Switch, the switch becomes inoperable and the Front Panel LEDs flash GREEN constantly when a chassis intrusion, such as the cover being removed, is detected. The Intrusion Detection is an always-on function. If all your front panel LED flash continuously, or the switches enclosure appears breached, avoid using this product and contact your Raritan dealer. 7

Administrator Functions Administrator functions by the Raritan Secure Switch enables authorized Administrator to configure the Secure Switch, configure user authentication device filtering, and audit log data generated by the Secure Switch. Log data audit: Log data generating and recording is activated when the KVM is manufactured and can not be disabled or erased. The Raritan Secure Switch Administrator Functions enable authorized Administrator to download, view, and audit important log data and events. User Authentication Device filtering configuration: This function enables authorized Administrator to assign whitelist and blacklist for the User Authentication Device. The Secure Switch configuration: This function enables authorized Administrator to perform functions such as Reset to Factory Default. The Reset to Factory Default command on KVM clears White/Blacklists by both Admin function and Port Authentication Utility Administrator must first logon and be authenticated for the Secure Switch Administrator Functions. To maximize security, before performing other administrative functions, Administrator must set a new password after the first successful logon. (Administrator password can be changed anytime via Administrator Configuration.) Setup for Administrator Logon Administrator must logon and be authenticated for the Secure Switch administrative operations. This section helps you setup the installation for Administrator Logon. 1. Connect qualified Keyboard, Mouse, and Display to the Raritan Secure Switch console section. (Please refer to the Secure Switch User manual for details) 2. Connect a secure source computer to Port 1 of the Secure Switch KVM Port section via KVM cable sets. The USB cable that attaches to your computer's Keyboard / Mouse must be plugged in the KVM USB Port. (Please refer to the Secure Switch User manual for details) 3. Power on first the Raritan Secure Switch, and then power on the source computer. The Raritan Secure Switch will switch to Port 1 after a successful KVM self-test. 8

Raritan Secure Switch Series Administrator Guide version 1.0 Administrator Logon After the Administrator setup 1. Open a text editor on the connected source computer 2. Use the console keyboard and a. Press and hold down the Ctrl key b. Press the F12 key: [Ctrl] + [F12] c. Release the Ctrl and F12 key, press [L] key, and then press [Enter] After successful input of the key sequence, you will be in Administrator Logon mode and be prompted in text editor to be authenticated. 3. In the text editor, you will be prompted to input the default Administrator logon password. ATTENTION - This default Administrator password is used only for the first-time Administrator Logon. - To maximize security and to prevent unauthorized access to Secure Switch, please change default logon password after your first successful logon. Once changed, the default Administrator password will not be restored after Reset to Factory Default. 4. The default Administrator password for the first-time logon is: ABCD@xyz#2468! a. The password is case-sensitive b. Use [Shift] key for upper case letters and special characters 5. A [Logon OK] message prompts if the password input is correct; you will be prompt to input password again if the input password is wrong. a. With 3 (three) failed attempts to logon, the Administrator Logon mode will be terminated automatically. Access to Administrator Logon mode will be blocked for 15 minutes. b. With 9 (nine) failed attempts to logon, the Secure Switch becomes inoperable permanently. Please remove it from service immediately and contact your Raritan dealer. 9

6. Type [LIST] and press [Enter] for Administrator Functions after [Logon OK] message for Administrator Functions. (Command LIST displays administrator functions) 7. For maximum security, Administrator must change the Administrator Logon password via Administrator Functions after the first successful logon. The new password should contain, a. At least 8 characters in length, but no longer than 22 characters. b. A minimum of 1 lower case letter and, c. A minimum of 1 upper case letter and, d. A minimum of 1 numeric character and, e. A minimum of 1 special character Do not use the default Administrator password for your new password. Administrator will be asked to enter new password again for confirmation. Once the new Administrator Logon password is selected, the default Administrator Logon password will not be restored even after Reset to Factory Default. Log data audit Log data recording is activated when the KVM is manufactured and can not be disabled or erased. After the successful Administrator Logon, type the command [LIST] to view logs data in the text editor. (Command LIST displays administrator functions) Administrator Logon Mode ID: Administrator Please enter password: ******** Logon ok. 10

Raritan Secure Switch Series Administrator Guide version 1.0 Operation ok For the menu interface information, please refer to the Raritan PP3.0 Secure Switch Admin Log Audit Code Document. 1. KVM Information Area This area displays the Secure Switch status and critical information a. DATE-TIME: Current Date and Time in UTC b. MFG_DATE: Manufacturing Date (in UTC) of the Secure Switch c. TAMP_TEST: The Secure Switch Tamper protection test status d. HW_TEST: The Secure Switch hardware self-test status e. FW_TEST: The Secure Switch firmware self-test status f. FW_CHECKSUM: The Secure Switch firmware checksum for firmware integrity check. g. AUDT_ST: Date and Time (in UTC) when the KVM activates all protection mechanism and starts generating log data. 11

h. AUDT_SP: NA will be displayed if the Secure Switch functions normally. If events that trigger the Secure Switch protection mechanism are detected, and make the KVM shut down and become inoperable, a Date/Time log will be recorded for the Secure Switch manufacturer. (This particular Date/Time log can only be decoded by the Secure Switch manufacture) i. i. FW_VER: Firmware version j. j. TTL_LOGS: Total numbers of Log data 2. Log Data Area The Log Data Area is an area where critical and non-critical Log data can be displayed. Each Log/Event is recorded with data such as Date, Time and special codes to indicate the type and content of the event. These special codes can only be decoded and interpreted by the Secure Switch manufacturer. a. Critical Log Data: Critical Log Data includes Administrator Logon events (up to four events), Administrator password change events (up to two events), Critical Administrator KVM configuration (one event), and Self-test / Tampering events (up to five events) The last one of Critical Log data will be kept for audit. That means New Critical Log events will overwrite the old Log data and keep the last one record. b. Non-critical Log Data: Non-critical Log Data includes Administrator Logon records (including Administrator login and log-off events), Administrator password change events, Administrator configuration events, Device filter configuration events, Self-test events, and power cycle events. Maximum thirty-two Non-critical Log Data logs will be kept in the Secure Switch. The new log entry will overwrite the oldest one (for example, the thirty-third log entry will overwrite the first log) User Authentication Device filtering configuration Administration functions enable authorized Administrator to configure device filtering (CDF). This function allows the Administrator to configure the Secure Switch to accept or reject specific USB devices. For finding the detail description on port authentication utility, please refer to the Raritan Port Authentication Document 12

Raritan Secure Switch Series Administrator Guide version 1.0 Reset KVM to Default This Administrator function enables the authorized Administrator to reset the KVM configuration to factory default. 1. When Administrator performs Reset KVM to Default, settings previously configured by Administrator (such as USB device whitelist/blacklist) will be cleaned and reset to factory default settings. 2. Once Reset KVM to Default has been completed, the Secure Switch will terminate the Administrator Logon mode, purge keyboard/mouse buffer, and power cycle the Secure Switch automatically. After a successful self-test, KVM port focus will be switched to Port1, and CAC function of each port will be set to factory default (enabled). 3. Reset KVM to Default will not affect or erase Log data. 4. Reset KVM to Default will not affect previously changed Administrator password 5. Reset KVM to Default will clear the whitelist/blacklist created by both the Secure KVM administrator functions and the Raritan Port Authentication Utility Reset KVM to Factory Default (Actual Instructions) 1. Press the Reset button on the front panel to reset the Raritan Secure Switch. 2. When performing the reset function by pressing Reset Button for more than 5 seconds, Keyboard/Mouse buffer will be purged and KVM will reboot and perform self-test. 3. After a successful self-test, port focus will be switched to Port1, and CAC function of each port will be set to factory default (enabled). 4. If the Secure Switch fails to generate video on the monitor after reset, please power off the installation, check the installation, and follow the operation instructions in user manual to power on the installation. 13

Appendix Safety Instructions General This product is for indoor use only. Read all of these instructions. Save them for future reference. Follow all warnings and instructions marked on the device. Do not place the device on any unstable surface (cart, stand, table, etc.). If the device 14 falls, serious damage will result. Do not use the device near water. Do not place the device near, or over, radiators or heat registers. The device cabinet allows for adequate ventilation. To ensure reliable operation, and to protect against overheating, the cabinet must never be blocked or covered. The device should never be placed on a soft surface (bed, sofa, rug, etc.) as this will block its ventilation. Likewise, the device should not be placed in a built in enclosure unless adequate ventilation has been provided. Never spill liquid of any kind on the device. Unplug the device from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning. The device should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company. The device is designed for IT power distribution systems with 100-240V~. 1A, 50-60Hz input line voltage. To prevent damage to your installation it is important that all devices are properly grounded. The device is equipped with a 3-wire grounding type plug. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not attempt to defeat the purpose of the grounding-type plug. Always follow your local/national wiring codes. Do not allow anything to rest on the power cord or cables. Route the power cord and cables so that they cannot be stepped on or tripped over. If an extension cord is used with this device make sure that the total of the ampere ratings of all products used on this cord does not exceed the extension cord ampere rating. Make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes. To help protect your system from sudden, transient increases and decreases in electrical power, use a surge suppressor, line conditioner, or uninterruptible power supply (UPS). Position system cables and power cables carefully; Be sure that nothing rests on any

Raritan Secure Switch Series Administrator Guide version 1.0 cables. Never push objects of any kind into or through cabinet slots. They may touch dangerous voltage points or short out parts resulting in a risk of fire or electrical shock. Do not attempt to service the device yourself. Refer all servicing to qualified service personnel. If the following conditions occur, unplug the device from the wall outlet and bring it to qualified service personnel for repair. The power cord or plug has become damaged or frayed. Liquid has been spilled into the device. The device has been exposed to rain or water. The device has been dropped, or the cabinet has been damaged. The device exhibits a distinct change in performance, indicating a need for service. The device does not operate normally when the operating instructions are followed. CAUTION: Never attempt battery replacement or open the switches enclosure. MAINTENANCE STAFF CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. 15