NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

Similar documents
24-Channel, ±24 V Precision PXI Source Measure Unit

12-Channel, ±24 V Precision PXI Source Measure Unit

NI PXIe-4080/4081/4082

NI PXIe Contents GETTING STARTED GUIDE. RF Preselector Module

To access NI 5622 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

NI PXI Contents GETTING STARTED GUIDE. 8 GHz RF Amplifier

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

Electromagnetic Compatibility Guidelines

To access NI 5105 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI PXI/PXIe/PCI Contents GETTING STARTED GUIDE. 14-Bit, 100 MS/s PXI Oscilloscope

Single-Channel Precision System Source Measure Unit (SMU)

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

PXI/PCI Contents GETTING STARTED GUIDE. 2 GS/s Oscilloscope

NI PXI-5650/5651/5652

To access NI 5114 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

NI PXIe-6544/6545/6547/6548

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

To access NI 5671 documentation, navigate to Start»All Programs»National Instruments» NI-RFSG»Documentation.

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

NI PXIe-6555/6556. Contents GETTING STARTED GUIDE. 200 MHz Digital Waveform Generator/Analyzer with PPMU

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

Electromagnetic Compatibility Guidelines

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

6 GHz Reconfigurable RF Vector Signal Transceiver with 1 GHz Bandwidth

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

100 MHz, 250 MS/s, 14-Bit PXI Express Oscilloscope. This document explains how to install and start using the PXIe-5172.

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

NI PXIe Contents GETTING STARTED GUIDE. 6 GHz T/R Two-Port Vector Network Analyzer

NI R Series. Contents. Software CALIBRATION PROCEDURE

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

6 GHz Reconfigurable RF Vector Signal Transceiver with 200 MHz Bandwidth

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

Bracket and Mounting Dimensions

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

INSTALLATION GUIDE AND SPECIFICATIONS PXIe-4844

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

This document includes instructions for installing and configuring your PXIe-8821 PXI Express controller module.

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

NI Safety Guidelines. Safety Guidelines for Hazardous Locations GETTING STARTED GUIDE. Ethernet Expansion Chassis for C Series Modules

Foundation Fieldbus Hardware and NI-FBUS Software

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

Figure 1. NI-7935R. Related Information For information about the device specifications, refer to the NI-7935R Specifications at ni.com/manuals.

Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules. This document describes how to begin using the NI crio-9064.

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

CALIBRATION PROCEDURE CAL Contents. Software

NI PXI Contents GETTING STARTED GUIDE

USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4340 and TB Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

Electrical. SPECIFICATIONS SH Cable

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

USRP Contents. Verifying the System Requirements GETTING STARTED GUIDE. USRP Software Defined Radio Stand-Alone Device

NI crio-9101/9102/9103/9104

Electromagnetic Compatibility Guidelines

Contents. CALIBRATION PROCEDURE NI PXIe-5624R 2 GS/s, 12-Bit IF Digitizer

This document includes instructions for installing and configuring your PXIe-8861 PXI Express controller module.

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

NI ELVIS RIO Control Module

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-4357

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

Contents. Software CALIBRATION PROCEDURE NI TC-4353

SH Cable Specifications

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4322 and TB Channel, Isolated Voltage/Current Analog Output Module

Contents. Software Requirements CALIBRATION PROCEDURE NI TB-4353

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4357 and TB-4357

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

10 MHz to 6 GHz, x86 Processor, GPS-Disciplined OCXO, USRP Software Defined Radio Stand-Alone Device

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

Electromagnetic Compatibility Guidelines

NI CMS-9068 and NI MMS-9068

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

NI WSN-9791 Ethernet Gateway

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

This document describes the features, functions, and operation of the NI PXIe-8383mc PXImc adapter module.

NI SMD-7610 Stepper Drives and NI 9512 C Series Modules

Electromagnetic Compatibility Guidelines

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4339 and TB-4339/B/C 8 Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module

GETTING STARTED GUIDE

Getting Results with the NI 5752R

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

NI 6521 Specifications

Getting Results with the NI PXI-6585R

Transcription:

GETTING STARTED GUIDE NI PXIe-4138/4139 Single-Channel System SMU Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the NI PXIe-4138/4139 (NI 4138/4139). The NI 4138/4139 is a single channel system source measurement unit (SMU). To access NI 4138/4139 documentation, navigate to Start»All Programs»National Instruments»NI-DCPower»Documentation. Contents Electromagnetic Compatibility Guidelines...1 Verifying the System Requirements...2 Unpacking the Kit... 2 Kit Contents... 3 Other Equipment... 3 Preparing the Environment... 4 Safety... 4 Installing the Software... 4 Installing the NI 4138/4139... 5 Configuring the NI 4138/4139 in MAX... 6 Programming the NI 4138/4139... 7 Troubleshooting... 8 What Should I Do if the NI 4138/4139 Doesn't Appear in MAX?...8 Why Is the ACCESS LED Off When the Chassis Is On?...8 Where To Go Next... 9 Worldwide Support and Services... 9 Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with

radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Caution To ensure the specified EMC performance, the length of all I/O cables must be no longer than 3 m (10 ft). Caution To ensure the specified EMC performance, you must install PXI EMC Filler panels, NI part number 778700-01, in all open chassis slots. A kit of six single slot EMC Filler Panels can be ordered at ni.com. Verifying the System Requirements To use the NI-DCPower instrument driver, your system must meet certain requirements. Refer to the product readme, which is available on the driver software media or online at ni.com/manuals, for more information about minimum system requirements, recommended system, and supported application development environments (ADEs). Unpacking the Kit Caution To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. 1. Touch the antistatic package to a metal part of the computer chassis. 2. Remove the device from the package and inspect the device for loose components or any other sign of damage. Caution Never touch the exposed pins of connectors. Note Do not install a device if it appears damaged in any way. 3. Unpack any other items and documentation from the kit. Store the device in the antistatic package when the device is not in use. 2 ni.com NI PXIe-4138/4139 Getting Started Guide

NSE HI ARD HI ARD LO NSE LO Kit Contents Figure 1. NI 4138/4139 Kit Contents NI PXIe-4138 System SMU ACCESS ACTIVE OUTPUT ±60 V, 3 A MAX 150 V MAX to OUTPUT CAT I 1 2 3 4 5 1. NI PXIe-4138/4139 System SMU Device 2. Output Connector Assembly 3. Driver Software DVD 4. NI PXIe-4138/4139 Getting Started Guide (this document) 5. Maintain Forced-Air Cooling Note to Users Other Equipment There are several required items not included in your device kit that you need to operate the NI 4138/4139. Your application may require additional items not included in your kit to install or operate your device. Required Items A PXI Express chassis and chassis documentation. For more information about compatible chassis options, refer to ni.com. A PXI Express embedded controller or MXI controller system that meets the system requirements specified in this guide and chassis documentation. Note If your device is hardware revision F or earlier, a snap-on ferrite bead is required to remain in EMC compliance. Refer to the NI 4138/4139 Getting Started Guide included in your original shipping kit for information about this bead. To determine which revision of a device you have, open Measurement & Automation Explorer (MAX) and select the device in question. The hardware revision is displayed in the settings pane on right-hand side. NI PXIe-4138/4139 Getting Started Guide National Instruments 3

Optional Items NI screwdriver (part number 781015-01). Preparing the Environment Ensure that the environment you are using the NI 4138/4139 in meets the following specifications. Operating Environment Ambient temperature range Relative humidity range Storage ambient temperature range Maximum altitude Pollution Degree 2 Indoor use only. 0 C to 55 C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) 10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) -40 C to 70 C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.) 2,000 m (800 mbar) (at 25 C ambient temperature) Note Refer to the device specifications on ni.com/manuals for complete specifications. Safety Caution Always refer to the specifications document for your device before connecting signals. Failure to observe the specified maximum signal ratings can cause shock, a fire hazard, or damage to the devices connected to the NI 4138/4139. NI is not liable for any damage or injuries resulting from incorrect signal connections. Related Information For information about connecting signals for specific devices, refer to the ranges reference of the NI DC Power Supplies and SMUs Help. Installing the Software You must be an Administrator to install NI software on your computer. 4 ni.com NI PXIe-4138/4139 Getting Started Guide

1. Install an ADE, such as LabVIEW or LabWindows /CVI. 2. Insert the driver software media into your computer. The installer should open automatically. If the installation window does not appear, navigate to the drive, double-click it, and double-click autorun.exe. 3. Follow the instructions in the installation prompts. Note Windows users may see access and security messages during installation. Accept the prompts to complete the installation. 4. When the installer completes, select Restart in the dialog box that prompts you to restart, shut down, or restart later. Installing the NI 4138/4139 Caution To prevent damage to the device caused by ESD or contamination, handle the device using the edges or the metal bracket. 1. Ensure the AC power source is connected to the chassis before installing the modules. The AC power cord grounds the chassis and protects it from electrical damage while you install the modules. 2. Power off the chassis. 3. Inspect the slot pins on the chassis backplane for any bends or damage prior to installation. Do not install a module if the backplane is damaged. 4. Remove the black plastic connectors from all the captive screws on the module front panel. 5. Identify a supported slot in the chassis. The following figure shows the symbols that indicate the slot types. Figure 2. Chassis Compatibility Symbols NI PXIe-1062Q 1 2 3 4 5 1. PXI Express System Controller Slot 2. PXI Peripheral Slot 3. PXI Express Hybrid Peripheral Slot 4. PXI Express System Timing Slot 5. PXI Express Peripheral Slot NI 4138/4139 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. 6. Touch any metal part of the chassis to discharge static electricity. 7. Ensure that the ejector handle is in the unlatched (downward) position. 8. Place the module edges into the module guides at the top and bottom of the chassis. Slide the device into the slot until it is fully inserted. NI PXIe-4138/4139 Getting Started Guide National Instruments 5

Figure 3. Module Installation 1 NI PXIe-1075 2 3 1. Chassis 2. Hardware Module 3. Ejector Handle in Down (Unlatched) Position 9. Latch the module in place by pulling up on the ejector handle. 10. Secure the device front panel to the chassis using the front-panel mounting screws. Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis, which can improve the signal quality and electromagnetic performance. 11. Cover all empty slots using filler panels or slot blockers to maximize cooling air flow. 12. Connect the output connector assembly to the device. Tighten any thumbscrews on the output connector assembly to hold it in place. 13. Power on the chassis. Configuring the NI 4138/4139 in MAX Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX informs other programs about which devices reside in the system and how they are configured. MAX is automatically installed with NI-DCPower. 1. Launch MAX. 2. In the configuration tree, expand Devices and Interfaces to see the list of installed devices. Installed devices appear under the name of their associated chassis. 3. Expand your Chassis tree item. 6 ni.com NI PXIe-4138/4139 Getting Started Guide

MAX lists all devices installed in the chassis. Your default device names may vary. Note If you do not see your device listed, press <F5> to refresh the list of installed devices. If the device is still not listed, power off the system, ensure the device is correctly installed, and restart. 4. Record the device identifier MAX assigns to the hardware. Use this identifier when programming the NI 4138/4139. 5. Self-test the device by selecting the device in the configuration tree and clicking Self-Test in the MAX toolbar. The MAX self-test performs a basic verification of hardware resources. Programming the NI 4138/4139 You can generate signals interactively using the NI-DCPower Soft Front Panel (SFP) or you can use the NI-DCPower instrument driver to program your device in the supported ADE of your choice. Application Programming Interface (API) Table 1. NI 4138/4139 Programming Options Location Description NI-DCPower SFP NI-DCPower Instrument Driver Available from the start menu at Start»All Programs» National Instruments» NI-DCPower»NI-DCPower Soft Front Panel. LabVIEW Available on the LabVIEW Functions palette at Measurement I/O» NI-DCPower. C or LabWindows/CVI Available at Program Files» IVI Foundation»IVI» Drivers»NI-DCPower. Microsoft Visual C/C++ NI- DCPower does not ship with installed C/C++ examples. The NI-DCPower SFP acquires, controls, and presents data. The NI- DCPower SFP operates on the PC, to provide additional display capabilities. NI-DCPower configures and operates the device hardware and performs basic acquisition and measurement options using LabVIEW VIs or LabWindows/CVI functions. Refer to the Creating an Application with Microsoft Visual C and C++ topic of the NI DC Power Supplies and SMUs Help to manually add all required include and library files to your project. NI PXIe-4138/4139 Getting Started Guide National Instruments 7

Troubleshooting If an issue persists after you complete a troubleshooting procedure, contact NI technical support or visit ni.com/support. What Should I Do if the NI 4138/4139 Doesn't Appear in MAX? 1. In the MAX configuration tree, expand Devices and Interfaces. 2. Expand the Chassis tree to see the list of installed devices, and press <F5> to refresh the list. 3. If the module is still not listed, power off the system, ensure that all hardware is correctly installed, and restart the system. 4. Navigate to the Device Manager. Operating System Description Windows 8 Windows 7 Windows Vista Windows XP Right-click the Start screen, and select All apps»control Panel» Hardware and Sound»Device Manager. Select Start»Control Panel»Device Manager. Select Start»Control Panel»System and Maintenance»Device Manager. Select Start»Control Panel»System»Hardware»Device Manager. 5. If you are using a PXI or PXI Express controller, verify that a National Instruments entry appears in the system device list. Reinstall NI-DCPower and the device if error conditions appear in the list. If you are using an MXI controller, right-click PCI-to-PCI Bridge, and select Properties from the shortcut menu to verify that the bridge is enabled. Why Is the ACCESS LED Off When the Chassis Is On? The LEDs may not illuminate until the device has been configured in MAX. Before proceeding, verify that the NI 4138/4139 appears in MAX. If the ACCESS LED fails to illuminate after you power on the PXI Express chassis, a problem may exist with the PXI Express power rails, a hardware module, or the LED. 1. Caution Apply external signals only while the NI 4138/4139 is powered on. Applying external signals while the device is powered off may cause damage. Disconnect any signals from the PXI Express module front panels. 2. Remove any front panel connections from the NI 4138/4139. 3. Power off the PXI Express chassis. 4. Remove the module from the PXI Express chassis and inspect it for damage. Do not reinstall a damaged device. 8 ni.com NI PXIe-4138/4139 Getting Started Guide

NI PXIe-4138 5. Install the module in a different PXI Express chassis slot from which you removed it. 6. Power on the PXI Express chassis. 7. Verify that the device appears in MAX. 8. Reset the device in MAX and perform a self-test. If the ACCESS LED still fails to illuminate and failures continue, contact NI technical support or visit ni.com/support. Where To Go Next Located online at ni.com/manuals Located using the NI Example Finder EXPLORE LEARN CREATE the application development environment (ADE) for your application. about hardware features or review device specifications. custom applications within an application programming interface (API). Getting Started with LabVIEW Getting Started with LabWindows/CVI NI PXIe 4138 Specifications* OR NI PXIe 4139 Specifications* NI DC Power Supplies and SMUs Help* NI-DCPower Soft Front Panel NI-DCPower Instrument Driver NI DCPower Examples* NI DC Power Supplies and SMUs Help* DISCOVER more about your products through ni.com. Support ni.com/support Power Supplies Solutions ni.com/powersupplies Services ni.com/services NI Community ni.com/community *This item is also installed with the driver software. Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. NI PXIe-4138/4139 Getting Started Guide National Instruments 9

Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/ niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/ legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2014 2016 National Instruments. All rights reserved. 374671B-01 Jan16