Product Description. FX22, FX62, and FX70 Supervisory Controllers

Similar documents
Product Description. Date: November 3, 2011 Announcing: From: Released To:

FX Supervisory Controllers

FX Supervisory Controllers

Buy American Facility Explorer Products Facility Explorer Product Management Authorized Building Controls Specialists (ABCS)

Supervisory Controllers

TALON Network Manager- 2 & 6 Express

EC-BOS-8 Multi-protocol Web Building Controller

EC-BOS-8 Multi-protocol Web Building Controller

FX40 Supervisory Controller

controller data sheet JACE 8000 PRODUCT DEFINITION HARDWARE SPECIFICATIONS

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

NAE. Metasys. BAS network automation Supervisory controllers. Network Automation Engine

Clarity 3 GCE-8000 EMBEDDED IOT CONTROLLER PRODUCT DATA SHEET

Overview. Applications. Features

FX06 Field Controller

EC-Net 4 and EC-BOS-8 Frequently Asked Questions

Network Control Engine Catalog Page

HAWK 8000 Controller GENERAL. Product Data. Fig. 1. HAWK 8000

FX80 Supervisory Controller Catalog Page Code No. LIT Issued July 2018

controller data sheet JACE 8000 PRODUCT DEFINITION HARDWARE SPECIFICATIONS

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

J-201 Resource Capacity Guidelines and Sample Application Analysis

FX Supervisory Controller Upgrade and Migration Instructions Technical Bulletin

PRODUCT GUIDE. Intelligent Building Automation and Control. Intelligent Buildings Energy & Sustainability Automation & Control Security

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

Smart Equipment Controls (SEC)

Features Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Web-Based User Interface

FX Input/Output (I/O) Modules XM07 and XM14

Network Integration Engine (NIEx9) for Third-Party Integrations Catalog Page

OnCell G3100 Series Quick Installation Guide

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Mega_Link Telemetry Communication System

Turck Cloud Gateway UMTS Gateway TCG20-UMTS-1ETH-CRS-01

FX20/FX60 Supervisory Controllers Installation Instructions

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

controller data sheet JACE 8000 PRODUCT DEFINITION

Overview of the Cisco VG224 Voice Gateway

UC-8410A Quick Installation Guide

IOT-GATE-iMX7 Datasheet

Multiple Channel Approach. Marc Bertolin Regional Account Manager - Products

XPress DR+W Quick Start Guide

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Terminals. Spectrometer Probes. i::scan Ionselective. Probes. Physical Probes. Terminals. Software System. Configuration. Monitoring Stations

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

APS SCALE SERIES DIMENSIONS

Terminals. Spectrometer Probes. i::scan Ionselective. Probes. Physical Probes. Terminals. Software System. Configuration. Monitoring Stations

LCS85 Turnkey User's Guide Part No , Rev. F Software Release 6.1 Issued June 17, 2013 Supersedes January 30, 2011

FX80 Supervisory Controller Installation Instructions

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

INTELLIGENT SOLUTION MANAGING AUTOMATION

AX3-PPC, AX3-PPC-O, Programmable Plant Controllers

Introducing. and the. An introduction to the most advanced web-enabled open controls technology available today. Phil Barnett- Tridium Europe Ltd

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

EC-Net AX Product Releases. Available since August 14, 2012

MM-IM. Large works automation And data gateway. PRODUCT DATASHEET

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

EAGLEHAWK Controller. Product Data. U.S. Registered Trademark Copyright 2016 Honeywell Inc. All Rights Reserved

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

FX Tools Express Software Package

WEB-300E, WEB-600E/U, CP-300E, CP-600E/U Series Controllers

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

DTM Distributed Transmitter Monitor

ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085

UCM 94/1 3G/GPRS Modem for RTU32 Series

pco5 Overview February 2010 Air Conditioning Business Unit pco5 Overview slide n. 1

iologik 2500 HSPA/GPRS/WLAN Series

FX14 Field Controller

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

2.4. LinPAC-8000 Series

FieldServer X-25 Start-Up Guide

TG Technical specifications

Features and Benefits. Certifications

APP 700 Technical Specification

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

BACnet Controller for General-purpose Building Applications

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

AC5160 SiPass integrated controller kit

RST100 Alert & Tracking Solutions

IA240/241 Hardware User s Manual

4 Port Industrial RS-232 / 422 / 485 Serial to IP Ethernet Device Server - PoE-Powered - 2x 10/100Mbps Ports

TEC Terminal Box (VAV) Controller

FX30E/FX60E Supervisory Controllers Installation Instructions

EAGLEHAWK NX Controller

TONN/... Trend Open Network Node

EAGLEHAWK Controller. Product Data. U.S. Registered Trademark Copyright 2016 Honeywell Inc. All Rights Reserved

ModBerryM500 series. Features of new. ModBerryM500 ASK FOR NEW RASPBERRY PI 3 B+

Advanced Application Field Equipment Controller (FAC) Catalog Page

Baltos ir Contact Online. More Pictures. Click on the thumbnails for the large picture

NIE59 Network Integration Engine Figure 1: NIE59 Network Integration Engine

Remote monitoring and display solutions

NPort 6600 Series Quick Installation Guide

EasyIO FW 08VUser Reference

Wireless Gateway ARG600 Product Guide

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

Connected IoT applications

Transcription:

Date: November 12, 2010 Announcing: Facility Explorer Supervisory Controller Release 3.0 From: Facility Explorer Product Management Released To: System Services Americas (SSA) Asia Pacific System Services Europe (SSE) JCJPN Authorized Building Controls Specialists (ABCS) Systems Technology Distribution Product Description Johnson Controls, Inc. is pleased to announce new additions and enhancements to Facility Explorer Supervisory Controllers: FX22, FX62, and FX70 Supervisory Controllers FX Supervisory Controller Accessories FX Supervisory Controller Software Release 3.0 FX40 Trade-up Program FX22, FX62, and FX70 Supervisory Controllers The FX22, FX62, and FX70 are new additions to the Facility Explorer Supervisory Controller family. The FX22 and FX62 are wall mounted supervisory class controllers that contain 16 onboard Input/Output (I/O) points and an integral power supply. The FX22 and FX62 provide the same supervisory and control functionality as the FX20 and FX60 except that the FX22 and FX62 are housed in packages designed to reduce installation time and cost. The FX22 and FX62 include conduit knockouts, wiring labels, and power wire segregation with all wiring connections concealed. Connectivity is extended with the optional onboard General Packet Radio Services (GPRS) modem. You can have Web browser and FX Workbench access even when there is no Ethernet LAN connection. The onboard I/O points allow you to implement control applications without the need to run a separate field device trunk. The FX22 and FX62 are ideal for retrofits, new construction, small buildings, remote sites, and energy management applications. Figure 1: FX22 and FX62 Supervisory Controllers Code No. LIT-1200477 1

The FX70 is a DIN rail mounted supervisory controller similar to the FX20 and FX60 except slightly larger in size and with more computing resources. The FX70 is similar to a high performance, large capacity version of the FX60. The FX70 comes standard with 1 GB and 1 GB of flash memory. In addition, the FX70 has up to four times more RAM, eight times more flash, and a faster processor which enables more applications, larger databases, more histories, and more graphics. Figure 2: FX70 Supervisory Controller The new controllers support all of the same option cards and optional drivers as the FX20 and FX60, with one exception. The FX70 does not support the Wireless TEC option card at this time. Support for the Wireless TEC option card will be added to the FX70 in a future release. FX Supervisory Controller Accessories Also new is the RS-485 remote Input/Output module (LP-FXRIO16-0), which expands the Supervisory Controller s direct I/O capabilities. The FXRIO contains eight universal inputs, four relay outputs (Form A contacts), and four analog 0-10 VDC outputs. The FXRIO16 can be mounted up to 4,000 ft (1,219 m) from its host FX Supervisory Controller, using RS-485 networking. New GRPS modem option cards are now available to add cellular network remote access to the FX Supervisory Controllers. The FX22 and FX62 include models (FX2213 and FX6213) with the GPRS modem factory-installed. Alternatively, you can field mount this capability to FX20, FX60, and FX70 with the LP-FXGPRS-0 or LP-FXGPRSW-0 option cards. The GRPS modem option is a great capability to have for installation and commissioning during the early stages of a project when a hardwired Ethernet LAN has yet to be installed. 2

Technical Specifications Table 1: FX Supervisory Controllers Enclosure/ Mounting Dimension FX20 FX60 FX70 FX22 FX62 Plastic/DIN Rail 6.25 x 4 x 2.375 in. (158.75 x 101.6 x 60.325 mm) 8.5 x 6 x 2.625 in. (216 x 152 x 67 mm) Plastic/Wall 12.65 x 7.5 x 2.25 in. (321 x 191 x 57 mm) Power Supply DIN Rail Power modules Integral 24 VAC/DC Battery Backup Processor 5-minute internal PowerPC 405EP at 250 MHz PowerPC 440EP at 524 MHz RAM Memory 128 MB RAM 128 MB RAM (upgradeable to 256 MB) Heap 48 MB 48 MB (upgradeable to 96 MB) Flash Memory 5-minute internal, optional external PowerPC 440EPx at 667 MHz PowerPC 405EP at 250 MHz PowerPC 440 at 524 MHz 1 GB RAM 128 MB SDRAM 256 MB SDRAM 384 MB 48 MB 96 MB 64 MB Flash 128 MB Flash 1 GB Flash 64 MB Flash 128 MB Flash Environment Operating Temperature: 0 to 50 C (32 to 122 F) Storage Temperature: 0 to 60 C (32 to 140 F) Relative Humidity: 5 to 95%, noncondensing Communication Ports Onboard 2 Ethernet 10/100 Mbps 1 RS-485 1 RS-232 2 option slots 2 Ethernet 1 Gbps 1 RS-485 (Isolated) 1 RS-232 2 option slots Optional Two options slots (any 2 of the following, except where noted): Dual port RS-485 LON FT/TP-10 Modem (maximum of one and disables onboard RS-232 port of FX20/FX60) RS-232 Wireless TEC (Maximum of one and disables onboard RS-232 port of FX20/FX60)* GPRS modem (maximum of one) Sedona Framework 2 Ethernet 10/100 Mbps 1 RS-485 1 RS-232 1 option slot Integral GPRS modem (FX2213, FX6213 models only) One option slot (any one of the following): Dual port RS-485 LON FT/TP-10 Modem (disables onboard RS-232) RS-232 Wireless TEC (disables onboard RS-232) GPRS modem (not available on models with integral GPRS modem) Sedona Framework Continued on the next page... *The LP-FX7011N-0 will not support the LP-FXWTC-0 (wireless TEC) option card at Release 3.0, but the option card will be supported at a future release. 3

(Cont.) FX20 FX60 FX70 FX22 FX62 Network Drivers Embedded N2, Niagara, obix, Wireless TEC Optional LONWORKS, BACnet MS/TP, BACnet IP Client, BACnet IP Server, ModBus RTU Client, ModBus RTU Server, ModBus TCP Client, ModBus TCP Server, SNMP, SMS Direct I/O Onboard None 8 Universal Inputs (0-100 K ohm, 0-10 VDC, 0-20 ma with external resistor, or 10 K ohm type 3 thermistor) 4 Relay Outputs (Form A, 24 VAC at 0.5 A) 4 Analog Outputs (0-10 VDC) Local (NDIO Up to 66 total I/O (via optional NDIO modules) None Remote I/O Up to 64 I/O via 4 Remote I/O Modules (FXRIO16) Up to 256 I/O via 16 Remote I/O Modules (FXRIO16) Up to 48 I/O via 3 Remote I/O Modules (FXRIO16) Up to 240 I/O via 15 Remote I/O Modules (FXRIO16) FX Supervisory Controller Software Release 3.0 Facility Explorer Supervisory Controller Software Release 3.0 uses Niagara AX 3.5, which contains several new features and enhancements. Some of the new features are: Export Tagging: allows certain items of an FX Supervisory Controller station to be tagged for export to an FX Server station. All the export tags of a FX Supervisory Controller station can be automatically mapped into the FX Server when the supervisory controller joins the FX Server. Tagging is available for Px views (graphics), control points, histories, schedules, files, and components. Tagging allows you to automate the time consuming process of discovering data in a FX Supervisory Controller and then mapping into an FX Server. History Grouping: allows logical groupings of histories based on dynamic property values. The history database can now have multiple navigation trees that are customized for your specific project. On-Call Service: allows the routing of alarms to multiple people based on a prioritized contact list, including delays and escalation. Standard scheduling can be used to manage who is on call and when they are on call. Email and SMS Alarm Acknowledgement: provides a method for users to acknowledge alarms by simply replying to the email or SMS alarm notification. 4

Documentation Table 2: Related FX Series Supervisory Controllers Documentation Document Title FX20/FX60 Supervisory Controllers Product Bulletin FX20/FX60 Supervisory Controllers Catalog Page FX Server Product Bulletin FX Server Catalog Page Facility Explorer Supervisory Products Networking Technical Bulletin TEC Series Wireless Thermostat Controller System for FX20/FX40/FX60 Controllers Technical Bulletin TEC Series Wireless Thermostat Controller for FX20/FX60s with a Wireless TEC Option Card Technical Bulletin LIT Number LIT 12011406 LIT 1900552 LIT 12011122 LIT 1900385 LIT 12011360 LIT 12011453 LIT 12011541 FX20/FX60 Wireless TEC Option Card Installation Instructions 24 9890 889 FX Supervisory Products Upgrade Instructions FX20, FX40, and FX60 Protocol Implementation Conformance Statement FX Workbench User's Guide (Online Help) LIT 12011441 LIT 12011047 LIT 12011149 FX20/FX60 LON Card Installation Instructions 24 10174 34 FX20/FX60 Modem Card Installation Instructions 24 10174 26 FX20/FX60 RS 232 Card Installation Instructions 24 10174 85 FX20/FX60 RS 485 Card Installation Instructions 24 10174 69 5

Ordering Information Table 3: Supervisory Controllers Product Order Codes and Confidential Price List Product Code Number Description List Price (USD) LP-FX2211T-0 FX22 with 128 MB RAM/64 MB Flash, two 10/100 Mb Ethernet ports, one RS-485 serial port, one RS-232 serial port, sixteen I/O, one communication card option slot, Web User Interface, Embedded Workbench, Niagara driver obix driver, N2 driver. $3,600.00 LP-FX2213T-0 LP-FX6211T-0 LP-FX6213T-0 LP-FX7011N-0* LP-FXRIO16-0 FX22 with GPRS modem; includes 128 MB RAM/64 MB Flash, two 10/100 Mb Ethernet ports, one RS-485 serial port, one RS-232 serial port, sixteen I/O, one communication card option slot, Web User Interface, Embedded Workbench, Niagara driver, obix driver, N2 driver. FX62 with 256 MB RAM/128 MB Flash, two 10/100 Mb Ethernet ports, one RS-485 serial port, one RS-232 serial port, sixteen IO, one communication card option slot, Web User Interface, Embedded Workbench, Niagara driver, obix driver, N2 driver. FX62 with GPRS modem; includes 258 MB RAM/128 MB Flash, two 10/100 Mb Ethernet ports, one RS-485 serial port, one RS-232 serial port, sixteen I/O, one communication card option slot, Web User Interface, Embedded Workbench, Niagara driver, obix driver, N2 driver. FX70 with 1 GB Flash memory, one RS-232, one RS-485 port, two Gigabit Ethernet ports, two USB ports, two communication card option slots, internal battery backup. Standard features include Web User Interface, Embedded Workbench, obix driver, Niagara driver. Sixteen Channel Remote I/O module for FX20, FX22, FX60, FX62, and FX70. Includes eight Universal Inputs, four Form A Relay Outputs, four 0-10 VDC Analog Output. $4,000.00 $6,300.00 $6,600.00 $8,400.00 $665.00 LP-FXGPRS-0 GPRS Modem option card for FX20, FX60, and FX70 $650.00 LP-FXGPRSW-0 LP-FXGPRSE-0 LP-FXGPRSS-0 LP-FXGPRSU-0 GPRS Modem option card for FX20, FX60, and FX70 with Wyless SIM card Included is a 6.56 ft (2 m) SMA type coax extension cable and steel bracket for wall or panel mounting of the GPRS Modem antenna. GPRS Modem SIM card replacement provisioned by Wyless GPRS Modem retrofit kit for FX22 and FX62; uses one option card slot. This is for FX22s andfx62s purchased without the internal GPRS modem. Includes a Wyless SIM and a remote mount antenna with mounting bracket. $695.00 $80.00 $40.00 $700.00 Continued on next page... *The LP-FX7011N-0 will not support the LP-FXWTC-0 (wireless TEC) option card at Release 3.0, but the option card will be supported at a future release. 6

Product Code Number (Cont.) LP-FXSED-0 LP-FXSEDEXT-0 Description Sedona Framework option card with both wireless 6LoWPAN and wired RS-485 port, based on the Jennic JN5139 wireless microcontroller. Includes stub antenna. 6.56 ft (2 m) RP-SMA type coax extension cable and mounting bracket. List Price (USD) $600.00 $165.00 LP-KITFX7BAT-0 FX70 Replacement Backup battery assembly $100.00 LP-KITFX2HW-0 Hardware bag for FX22, FX62 containing removable screw terminal connector blocks (two 7-position, three 6- position, one 2-position). $75.00 LP-KITFXRIO-0 Hardware bag for FXRIO16 $49.00 LP-KITFX2DB-0 LP-KITFX7HW-0 LP-KITSEDAT-0 FX22 and FX62 Adapter, RJ-45 to DB-9 null modem, for onboard RS-232 serial port to connect to DTE device. Hardware Bag for FX70, containing screw terminal connector plugs (two 6-position, one 2-position, earth grounding wire). Replacement adjustable-angle 2.4GHz RP-SMA coaxmounted stub antenna for Sedona option card $63.00 $100.00 $52.00 LP-KITSED3T-0 3-terminal wiring plug for RS-485 for Sedona option card $10.00 Tool Requirements FX Tools Supervisor Pro Release 3.0 is required to program, download, and commission the new FX22, FX62, and FX70 controllers and to use the new Remote I/O Module and GPRS Module accessories. 7

Table 4: Supervisory Controllers Product Order Codes and Confidential Price List Product Code Number Description List Price (USD) LP-FXTSPDEM-0 Single user, engineering/demo version of FX Tools Supervisor Pro software, delivered on CD-ROM. Includes all software modules and drivers needed to engineer and commission stations for FX Supervisory Controllers and FX Servers. You must also purchase the office support and renewal fee to activate this software. License expires every October 31 and must be renewed yearly to continue operation. $561.80 LP-FXTSPDEM-6 LP-FXTSPE-0 LP-FXTSPE-6 LP-FXWS-0 LP-FXWSLTD-0 LP-FXWS-6 Engineering/Demo version of FX Tools Supervisor Pro software delivered on CD-ROM: For upgrading only (provides the most recent version of FX Tools Supervisor Pro software for existing, licensed users). End user version of FX Tools Supervisor Pro software, delivered on CD-ROM. Includes a non-expiring license. Can only be used to engineer or commission FX Supervisory Controller and FX Server stations via an online connection. End user version FX Tools Supervisor Pro software delivered on CD-ROM. For upgrading only (provides the most recent version of FX Tools Supervisor Pro software for existing, licensed users). FX Server software on CD-ROM. Allows integration of an unrestricted number of FX Supervisory Controllers. Includes FX Workbench and a 1-year software maintenance agreement. FX Server software on CD-ROM. Allows integration of up to three FX Supervisory Controllers. Includes FX Workbench and a 1-year software maintenance agreement. FX Server software on CD-ROM. For upgrading only (provides the most recent version of FX Server for existing, licensed users). $33.74 $2,968.00 $33.74 $7,760.07 $4,340.70 $33.74 LP-FXALMPTL-0 FX Alarm Portal client $204.79 LP-FX40UPG-0 LP-FXSWUPG-0 License enabling one-time, new release software upgrade for one FX Supervisory Controller (FX20, FX22, FX40, FX60, FX62, and FX70). License enabling one-time, new release software upgrade for one FX Server or one End User Version of FX Tools Supervisor Pro $334.19 $822.50 To upgrade an FX Supervisory Controller to the Release 3.0 software, the FX Supervisory Controller requires there to be a minimum of 10 MB file system free space. The file system free space size can be determined by looking at the station s Platform Service Container or from the Platform s Platform Administration node of the Nav tree. If there is not 10 MB (10,000 KB) of free space, user intervention is needed to remove files, histories, and/or alarms to reduce file space usage until there is free space of at least 10 MB. Most FX40 controllers may not have enough files space memory for this upgrade. 8

Facility Explorer FX40 Trade-up Program Effective Through March 31, 2011 For a limited time only, when you purchase select FX Supervisory Controllers from Johnson Controls, you will receive up to a $300.00 credit for each FX40 you trade in. Program Details The new FX Supervisory Controller software (release 3.0) features Niagara AX 3.5, which uses more memory than previous versions. As a result, most FX40 controllers will not operate properly with the new 3.0 release. Johnson Controls wants to provide an upgrade path for all FX40 users, so we are offering the FX40 upgrade program through March 31, 2011. Rebate Information You must meet the following criteria to receive the rebate: You must order the replacement controllers with the new T code numbers as shown in Table 5. You must return the existing FX40 controller to Erlanger within 90 days of shipment of the replacement controllers. Ordering the Replacement Controller Contact Johnson Controls Product Sales at 1.800.275.5676 to place an order and request an RMA. See Table 5 for product information. Table 5: Product Code Numbers Purchase Product Code Number LP-FX2211T-0T (same as LPFX2211T-0) LP-FX6211T-0T (same as LP-FX6211T-0) Return Product Code Number* LP-FX4020A-0 $150.00 LP-FX4021A-0 $150.00 LP-FX4022A-0 $150.00 LP-FX4023A-0 $150.00 LP-FX4020A-0 $300.00 LP-FX4021A-0 $300.00 LP-FX4022A-0 $300.00 LP-FX4023A-0 $300.00 Rebate Amount (US Dollars) *When returning the old hardware, include a copy of the RMA and the packing slip from the new LP-FXx211T-0T shipment. Upon receipt of the returned FX40 controller, appropriate rebate dollars will be credited. Failure to return the existing FX40 controller(s) within 90 days of shipment of the replacement controller(s) or lack of required information will delay or may void the rebate. Release Schedule Table 6: Release Schedule for the FX22, FX62, FX70, FX Supervisory Controller Accessories, and Release 3.0 Software Item Date Orderable Date November 12, 2010 Shipping Date (except FX70) December 15, 2010 Shipping Date (FX70) January 3, 2011 Sales Documentation on QuickLit November 12, 2010 Technical Documentation on QuickLit November 12, 2010 9

Sincerely, Mike Piotrowski Product Manager Facility Explorer Supervisory Controllers Product Development Michael.piotrowski@jci.com 10