SLA Battery Capacity Analyzer

Similar documents
1-36V, 0-3A DC Power Supply

Multi Range DC Power Supply

CONTENTS Safety Information Description Features Specifications Nomenclature And Function Operating Preparation Calibration Procedure

DC 100 A Current Probe

Model M140 Mini Solar Power Meter

INSTRUCTION MANUAL. Models: H100 Light Meter

INSTRUCTION MANUAL. Models: H200 Single Channel K, J, T, E, R Thermometer

DC 100 A Current Probe

User's Guide. Extech AM A AC Analog Clamp Meter

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide

User's Guide. Model High Precision Quad Output DC Power Supply

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PS8 - II. Professional Power Sequencer. User s Manual

Mini Digital Multimeter

User s Guide. 600A AC Clamp Meter. Model 38387

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

MTP INSTRUCTION MANUAL

Model 9103 and Multi-Range DC Power Supply USER MANUAL

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

700 Series 200 Amp Clamp Meters

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

CA846 THERMO-HYGROMETER ENGLISH. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

ENGLISH. User manual.

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

Operating Instructions

Models H115, H116, H117 Light, UVA, Solar Power Meters. H117 Light, UVA, Solar Power Meter

Conductive Level Controller

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Micro-Ohmmeter Model 6292

High Precision Quad Output DC Power Supply

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Operating Instructions

WiFi Connector. Instructions. Introduction. Safety. XWWarning

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

POCKET MULTIMETER 5115 ENGLISH User Manual

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Mini Digital Multimeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

PanelView Plus/VersaView CE Terminals and Display Modules

Quick Start/Installation Guide

9040/9040UK. Users Manual. Phase Rotation Indicator

7032 Digital-Analog Multimeter

User's Guide. Phase Sequence and Motor Rotation Tester Model

OPERATING INSTRUCTIONS

User Guide. Control Box. RoscoLED TM.

Two Channel 48 Volt Phantom Power Supply. Artcessories. User's Manual

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

Dual Display LCR Meter Model 878A / 879

Agilent 70612B K18 Switch Matrix

HV-CS kv Edge Mount Triaxial Jack

Variable Temperature Digital Solder and Testing Station

1690-Series Logic Analyzers

4 Port USB Power Hub. Model: JH-800 USER MANUAL

3.5 TFT LCD CCTV Service Viewer with Wristband LCD35SV

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

ETHOS Auto Ranging Digital Multimeter

PIM-Mini Pulsed Current Source Operation Manual

TCP305A & TCP312A AC/DC Current Probes Instructions

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

Three-phase Phase-sequence Phase-loss Relay

Instructions. P MHz 10X Passive Probe

P4472 Save A Watt HD Operation Manual

Mini Digital Multimeter

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

UÊ, Ê* - 1 Ê Ê Ê " /",Ê

EPS Power Supply

Instruction Manual RS-1660

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

Digital Overhead Stirrer

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

Model P4470 Save A Watt Operation Manual

Model 3526-B Digi-Probe Multimeter

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Sound Level Pen Instruction Manual

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

1103 Power Supply (SN B and Above) Instruction Manual

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

PCM-7140 Pulsed Current Source Operation Manual

Solar Installation PV100 Operating Instructions

DVI ELR Extender over one CAT5

MODEL 805 USER MANUAL

BatteryCheck USER MANUAL BATTERY MANAGEMENT TECHNOLOGY THAT POWERS YOUR ADVENTURES.

Transcription:

Model: 601B SLA Battery Capacity Analyzer USER MANUAL

Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service, and repair of this instrument. Before applying power to this instrument: Read and understand the safety and operational information in this manual. Apply all the listed safety precautions. Verify that the voltage selector at the line power cord input is set to the correct line voltage. Operating the instrument at an incorrect line voltage will void the warranty. Make all connections to the instrument before applying power. Do not operate the instrument in ways not specified by this manual or by B&K Precision. Failure to comply with these precautions or with warnings elsewhere in this manual violates the safety standards of design, manufacture, and intended use of the instrument. B&K Precision assumes no liability for a customer s failure to comply with these requirements. Category rating The IEC 61010 standard defines safety category ratings that specify the amount of electrical energy available and the voltage impulses that may occur on electrical conductors associated with these category ratings. The 2

category rating is a Roman numeral of I, II, III, or IV. This rating is also accompanied by a maximum voltage of the circuit to be tested, which defines the voltage impulses expected and required insulation clearances. These categories are: Category I (CAT I): Measurement instruments whose measurement inputs are not intended to be connected to the mains supply. The voltages in the environment are typically derived from a limited-energy transformer or a battery. Category II (CAT II): Measurement instruments whose measurement inputs are meant to be connected to the mains supply at a standard wall outlet or similar sources. Example measurement environments are portable tools and household appliances. Category III (CAT III): Measurement instruments whose measurement inputs are meant to be connected to the mains installation of a building. Examples are measurements inside a building's circuit breaker panel or the wiring of permanently-installed motors. Category IV (CAT IV): Measurement instruments whose measurement inputs are meant to be connected to the primary power entering a building or other outdoor wiring. Do not use this instrument in an electrical environment with a higher category rating than what is specified in this manual for this instrument. 3

You must ensure that each accessory you use with this instrument has a category rating equal to or higher than the instrument's category rating to maintain the instrument's category rating. Failure to do so will lower the category rating of the measuring system. Do not operate in an explosive or flammable atmosphere Do not operate the instrument in the presence of flammable gases or vapors, fumes, or finely-divided particulates. The instrument is designed to be used in office-type indoor environments. Do not operate the instrument In the presence of noxious, corrosive, or flammable fumes, gases, vapors, chemicals, or finely-divided particulates. In relative humidity conditions outside the instrument's specifications. In environments where there is a danger of any liquid being spilled on the instrument or where any liquid can condense on the instrument. In air temperatures exceeding the specified operating temperatures. In atmospheric pressures outside the specified altitude limits or where the surrounding gas is not air. 4

In environments with restricted cooling air flow, even if the air temperatures are within specifications. In direct sunlight. This instrument is intended to be used in an indoor pollution degree 2 environment. The operating temperature range is 0 C to 40 C and the operating humidity range is 95% relative humidity with no condensation allowed. Measurements made by this instrument may be outside specifications if the instrument is used in non-officetype environments. Such environments may include rapid temperature or humidity changes, sunlight, vibration and/or mechanical shocks, acoustic noise, electrical noise, strong electric fields, or strong magnetic fields. Do not operate instrument if damaged If the instrument is damaged, appears to be damaged, or if any liquid, chemical, or other material gets on or inside the instrument, remove the instrument's power cord, remove the instrument from service, label it as not to be operated, and return the instrument to B&K Precision for repair. Notify B&K Precision of the nature of any contamination of the instrument. Clean the instrument only as instructed 5

Do not clean the instrument, its switches, or its terminals with contact cleaners, abrasives, lubricants, solvents, acids/bases, or other such chemicals. Clean the instrument only with a clean dry lint-free cloth or as instructed in this manual. Not for critical applications This instrument is not authorized for use in contact with the human body or for use as a component in a lifesupport device or system. Do not touch live circuits Instrument covers must not be removed by operating personnel. Component replacement and internal adjustments must be made by qualified service-trained maintenance personnel who are aware of the hazards involved when the instrument's covers and shields are removed. Under certain conditions, even with the power cord removed, dangerous voltages may exist when the covers are removed. To avoid injuries, always disconnect the power cord from the instrument, disconnect all other connections (for example, test leads, computer interface cables, etc.), discharge all circuits, and verify there are no hazardous voltages present on any conductors by measurements with a properly-operating voltage-sensing device before touching any internal parts. Verify the voltage-sensing device is working properly before and after making the measurements by testing with known-operating voltage sources and test for both DC and AC voltages. Do not attempt any service or adjustment unless another person capable of rendering first aid and resuscitation is present. Do not insert any object into an instrument's ventilation openings or other openings. 6

Servicing Do not substitute parts that are not approved by B&K Precision or modify this instrument. Return the instrument to B&K Precision for service and repair to ensure that safety and performance features are maintained. For continued safe use of the instrument Do not place heavy objects on the instrument. Do not obstruct cooling air flow to the instrument. Do not place a hot soldering iron on the instrument. 7

Table of Contents Section 1 General Description... 9 1.1 INTRODUCTION... 9 1.2 APPLICATIONS... 9 1.3 SPECIFICATIONS... 9 Section 2 Operation... 10 2.1 Front Panel Controls... 10 2.2 Operating Procedure... 11 Service Information... 14 Limited One-Year Warranty... 15 8

Section 1 General Description 1.1 INTRODUCTION B&K Precision Battery Capacity Analyzer Model 601B measures the terminal voltage, internal resistance, and percent of charged capacity left in a battery. The model 601B supports 6V & 12V storage type lead acid batteries with wide range of Ah capacity. No external power (Mains or DC) is required. The unit works on the BUT (Battery Under Test) power. 1.2 APPLICATIONS The 601B Battery Capacity Analyzer address the need to test and maintain sealed lead acid (SLA) batteries used in backup power UPS, emergency lighting, fire alarms, security systems, and many other electrical systems. By quickly characterizing a battery s response to a load resistance, these meters display the remaining battery capacity as an indicator of the battery s health. 1.3 SPECIFICATIONS Voltage Ranges: 6V, 12V automatically selected Display: i) Capacity 0% to 100% ii) No load Voltage & loaded Voltage iii) Internal Resistance Min. Input Voltage: 4.8V NOTE: Specifications and information are subject to change without notice. Please visit www.bkprecision.com for the most current product information. Max. Input Voltage: 20V Measurable Ah Selection: Programmable 5-100Ah in steps of 1Ah No Load Voltage Accuracy: ±0.2% ±1 counts Voltage Resolution: 10mV Dimensions (WxHxD): 2.91 x 10.44 x 2.28 (74 x 26 5. 1 x 58mm ) Weight: 2.65lb (1.2 kg) 9

Section 2 Operation 2.1 Front Panel Controls 1. Power / Select: Powers on unit after connecting to BUT. Also used to select Ah setting. After activation user can select the Ah values as per BUT rating using this key. 2. Up: This key is used to increase the Ah values. 3. Down: With this key, the user can decrease the Ah values. 4. Test: On pressing this key the measurement will begin. 5. Repeat Test: This key is used to repeat previously performed test. 6. Reverse Polarity LED: This LED glows when the battery is reverse connected. 7. LCD : This is 16x2 line alphanumeric display. It displays various messages & results of tests as per Ah value selected. 8. -ve Cable: Negative connecting cable with strain relief. 9. +ve Cable: Positive connecting cable with strain relief. 10

2.2 Operating Procedure Follow the steps as outlined below: 2.2.1 Connection Procedure Connect Battery Capacity Analyzer (601B) to Battery Under Test (BUT). Connect the +ve terminal of 601B to +ve terminal of Battery. Connect -ve terminal of 601B to -ve terminal of Battery. The 601B will be powered by the BUT. To power on the unit, press & hold the POWER key. On Power up, 601B performs a memory test & displays open circuit voltage on LCD. CAUTION : Do not connect the +ve terminal of 601B to -ve terminal of BUT and -ve terminal of 601B to +ve terminal of BUT. On doing so, the 'Reverse Polarity' LED glows. 2.2.2 Operation Procedure On Power up, following screens will appear. BK-PRECISION BK-601B Next the unit goes the memory test. Following message will be displayed. MEMORY TEST If memory test is OK. FOUND PREVIOUS SETTINGS If the memory test fails: NO SETTINGS FOUND LOADING DEFAULTS 11

If the flash memory is corrupted, following Message is displayed: INT MEMORY ERROR LOADING DEFAULTS Next screen directs the user to the menu to select the sub-menu. The battery is auto-sensed & the defaults are loading accordingly. After memory test, the open circuit voltage is displayed on the first line of LCD, the required Ah value can be selected using up & down keys. OPEN CKT: 12.53V SELECT Ah: 028 On selecting the required Ah value, press Select Ah & then press the TEST key, the measurements will begin & following message is displayed. Backlight will switch off during the test. TEST INPROGRESS 12.53V 028AH The results will be displayed as follows. 12.37V 61.87%CAP IR: 39.2 mohm The first field indicates the battery terminal voltage when battery was loaded during the test; the second field shows the balance capacity in percentage. IR indicates the internal resistance in milli-ohms. After the test, follows a cooling period of approximately 15 seconds. If user tries to perform a test during this period, the following message is displayed. TO BEGIN NEXT SESSION, WAIT. In case the open circuit voltage of BUT exceeds 14.8V, the following screen will be continuously flashed & you will not be able to enter the test mode. 12

X HIGH VOLTAGE X REMOTE BATTERY Once the test period elapses the following screen will be displayed. OPEN CKT: 12.53V SELECT Ah: 028 To start a new test, press SELECT Ah key & in order to repeat the same test, press TEST REPEAT key. To prevent unnecessary discharge of BUT, the unit will switch off automatically after 5 minutes of non-operational period. 1) Do not connect Model 601B to a voltage source more than 20V. 2) Do not connect the unit to a battery connected in circuit. 13

Service Information Warranty Service: Please go to the support and service section on our website at www.bkprecision.com to obtain a RMA #. Return the product in the original packaging with proof of purchase to the address below. Clearly state on the RMA the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Non-Warranty Service: Please go to the support and service section on our website at www.bkprecision.com to obtain a RMA #. Return the product in the original packaging to the address below. Clearly state on the RMA the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Customers not on an open account must include payment in the form of a money order or credit card. For the most current repair charges please refer to the service and support section on our website. Return all merchandise to B&K Precision Corp. with prepaid shipping. The flat-rate repair charge for Non-Warranty Service does not include return shipping. Return shipping to locations in North America is included for Warranty Service. For overnight shipments and non-north American shipping fees please contact B&K Precision Corp. B&K Precision Corp. 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com 714-921-9095 Include with the returned instrument your complete return shipping address, contact name, phone number and description of problem. 14

Limited One-Year Warranty B&K Precision Corp. warrants to the original purchaser that its products and the component parts thereof, will be free from defects in workmanship and materials for a period of one year from date of purchase. B&K Precision Corp. will, without charge, repair or replace, at its option, defective product or component parts. Returned product must be accompanied by proof of the purchase date in the form of a sales receipt. To help us better serve you, please complete the warranty registration for your new instrument via our website www.bkprecision.com Exclusions: This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs. The warranty is void if the serial number is altered, defaced or removed. B&K Precision Corp. shall not be liable for any consequential damages, including without limitation damages resulting from loss of use. Some states do not allow limitations of incidental or consequential damages. So the above limitation or exclusion may not apply to you. This warranty gives you specific rights and you may have other rights, which vary from state-to-state. B&K Precision Corp. 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com 714-921-9095 15

CE Declaration of Conformity This instrument meets the requirements of 2006/95/EC Low Voltage Directive and 2004/108/EC Electromagnetic Compatibility Directive with the following standards. Low Voltage Directive - EN61010-1 : 2001 EMC Directive - EN61326-1 : 2013 - CISPR11 - EN61000-4-2 : 2009 - EN61000-4-3 : 2006 + A2 : 2010 - EN61000-4-8 : 2010 16

B&K Precision Corporation 22820 Savi Ranch Parkway Yorba Linda, California 92887 www.bkprecision.com 2015 B&K Precision Corporation Printed in Taiwan 120815 17