Smartstart Control Module

Similar documents
SMARTSTART MOTOR STARTERS

IPS INTELLIGENT PUMP STARTER

EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP

ENERGY MANAGEMENT SOFT-STARTER THE MOST INTELLIGENT SOFT-STARTER YET

FRANKLIN CONTROL SYSTEMS HVAC SMART STARTERS

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

MODELS DPDT DPDT DPDT-60MS DPDT-60MS

Installation, Operation and Maintenance Manual

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Controls Enclosed Non-Combination Starters - PESW Series

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

Enclosed DOL Motor Starter Type 4x, Plastic, 3-Phase

PHASE MONITOR RELAYS Product Summary

TECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

SP SP-T-9

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

S.W. Version SubMonitor Connect Installation & Operation Manual

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Quick Start Guide TS A

SED2 Variable Frequency Drives

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

For normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Jockey Pump Controllers

FX 2 Instruction Manual

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Table of Contents 1. Overview Installation...6

Variable Frequency Drive Design Guidelines

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

PowerFlex 400 AC Drive Guide Specification

INTEGRATED AUTOMATION ACTUATORS AND OPERATORS

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

Jockey Pump Controllers

GE Power Management. MMII Intelligent MCC Controller

VLT 2800 DRIVE SPECIFICATIONS

SS2200 Remote Controller

EH175 SA F 1-1 C 4 L A

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Table of Contents. Safety. Attention. Warnings

INSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

MODELS: STEAM FIRED YPC-ST-14SC & YPC-ST-16SL Thru YPC-ST-19S

SED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions

Installation Manual Updated May 2017

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

Trident and Trident X2 Digital Process and Temperature Panel Meter

Safety Control Relay Product Catalog

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.

Fire Pump Controllers Jockey Pump Controllers

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

AE R6 July 2018 Electronic Unit Controller

MAJOR VA Power Inverter

Room Controllers. SC3000 Relay Pack

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

60103 Circuit Breaker

ADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:

Mini Contactors & Overloads

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Standard SureVolt Power Conditioner / Voltage Regulator

Bulletin 1489 Circuit Breakers. Selection Guide

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

QCPort Cover Control Trouble Shooting Guide

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Elevator Systems Inc. TEERS Traction Elevator Emergency Return System

LM10 to MM200 Retrofit

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

SmartVFD Disconnect Panel Assemblies

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

PFC-10 Power Factor Controller

SLI 15 INVERTER SERIES, 1500 W

Output Relay Electrical Function Module

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Electric actuator for quarter-turn valves. For output torques to 17,700 lb. in.

Controls. Reduced Power Cost Extended Heater Life Less Maintenance Improved Process Products Stable Process Temperature. 4232/4233 Features

Transcription:

Smartstart TECHNOLOGY What is Smartstart? The patented Smartstart control module is an integrated, seamless solution that incorporates operator control, superior motor protection, and automation system compatibility in a rugged, compact unit. It offers a wide range overload and an extensive array of automation and control features that vary between models. Some of these features include Fireman s override, damper or valve control, Status (proof of flow), fault and shutdown, and more. The Smartstart module also accepts an incoming voltage range from 200-600VAC. This is true plug and play: no changing transformers, no messing with terminal blocks. How does Smartstart work? Smartstart takes an active role in protecting your motor by measuring the motor inrush current and using it to gauge a safe operating range for your motor. In this way it intelligently detects if your motor overload isn t set correctly, protects against locked rotor, cycle fault, stall conditions, and more. The unique functionality of Smartstart saves time, labor, and stocking units. It also provides superior motor protection. This is why some of the top manufacturers in America trust Smartstart to protect and control their motors. Smartstart Control Module integrates wide range overload, up to 600VAC voltage input, keypad, and automation I/O www.franklin-controls.com 1.800.962.3787

SMART START FEATURES INCREASED RELIABILITY AND REDUCED INSTALLATION COSTS 2 1 3 Smartstart Smart - Start safely. Smartstart patented technology predicts a safe operating range for your motor. Intelligent - With Smartstart enabled, if the starter isn t in range, it alarms and trips notifying you before damage occurs. 4 1. Smartstart 1-40A Electronic Protection Superior motor protection, significant inventory reduction, eliminates call backs due to mis-sizing 2. Direct 200-600VAC Connection Significant inventory reduction 3. Integrated Keypad with Remote Ease of operation, eliminates costly pilot devices 4. Automation Compatible. Dry inputs: Remote run, two external pilot devices, limit switch input (receives signal from actuator) Wet inputs (12-20VAC): Remote run, shutdown Relay output: Fault, proof of flow (detects loss of load) 24VDC output: Powers actuator Increases reliability, reduces installation costs, eliminates interposing relays. Power Failure Reset Options Select how the ISS will react after a power failure Power Fail Modes: Restart last mode, no delay (default) Restart with 10 second delay Restart Off - LED flashes last mode Motor Inrush 6-10x FLA Locked Rotor Trip Stall Trip Active - Smartstart detects harmful extended starting conditions with maximum time to start. Monitors motor inrush current conditions and trips if the motor doesn t start within 10 seconds (class 10 overload; regardless of FLA setting). Ingenious - Active current monitoring provides superior protection against locked rotor and stall conditions, tripping faster than a standard inverse trip curve, regardless of the FLA setting! Thoughtful - Blackbox recording feature retains critical information on last ten faults. Current (amps) FLA 1 2 3 4 6 7 8 9 10 Locked Rotor Current Typical Motor Stall Current Start Time (seconds) Standard Start Curve Max Time to Start Trip Motor Never Reaches FLA Standard Motor Starting Current 2

REDUCE INVENTORY ONE STARTER. ONE PART NUMBER. ONE SOLUTION. OR The ISS with Smartstart is an all-inclusive starter that reduces inventory and clears room on the shelf by eliminating the need to purchase loose components. 3

ISS with Smartstart INDUSTRIAL START/STOP WITH SMARTSTART MOTOR PROTECTION 3Ø, 200~600VAC, 1 40A, AUTOMATION SYSTEM READY Designed for ease of integration with automation systems Comprehensive inputs/outputs for building management systems Reduces installation costs Increased energy savings High reliability Smartstart (patent pending) for superior motor protection Electronic protection including locked rotor, cycle fault and maximum time to start (due to mis-sized motor or overload) FLA out of calibration indication--ensures installer sets overload correctly based on calculated motor size Advanced control inputs eliminate interposing relays Three dry inputs for remote and two external pilot devices* Two wet inputs (12-20VAC) for remote start and shutdown command Fault logging retains critical information Last 10 start conditions, including FLA setting, max inrush, run current, time to start, and safety start mode. Factory retrievable Universal application Wide-range electronic overload eliminates call backs due to mis-sized heaters Accepts up to 600V UL Type 1, 4, and 3R enclosures Lockable enclosure 3R features lockable keypad cover Start/Stop/Remote keypad with LED status indicators Intuitive operation and control with start (manual run), Stop, and Remote run modes Type 4 enclosed starters feature a 3 position switch for Start/Stop/Remote, and a Run Pilot Light NEMA Sized Combination versions include disconnect Motor circuit protection disconnect provides short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required Lockable handle for safety *dry inputs for external pilot devices not available with Type 4 enclosures 4 www.franklin-controls.com 1.800.962.3787

Specifications Starter Type ISS - Industrial Start/Stop with SmartStart Across the line or Full Voltage Non-Reversing NEMA 1, 3R, OR 4 enclosed Voltage range: 3Ø, 200-600 VAC Amperage range: 1-40A User Interface Start/Stop/Remote keypad with mode LEDs (N1 & 3R), Start/Stop/Remote switch & Run Pilot light (N4) Standard Control Operations 12-20V Remote Apply 12-20VAC/DC to energize Dry Remote N.O. Dry Contact Shutdown Apply 12-20VAC/DC to energize Inputs Limit Switch N.O. Dry Contact Internal Pilot Device N.O. Dry Contact (N1 & 3R only) External Pilot Device N.O. Dry Contact (N1 & 3R only) N.O. Relay Contact Ratings: Proof of flow current status 110VDC, 0.3A Resistive, 12VDC, 0.A GP 30VDC, 2.0A Resistive Outputs 120VAC 0/60Hz, 0.A Resistive Starter Fault 12VAC 0/60Hz, 1.0A GP 240VAC 0/60Hz, 0.2A Resistive Damper/Actuator 24 VDC, 1A maximum Operational Power fail modes Restart last mode, no delay (default) Restart with 10 second delay Restart Off - LED flashes last mode Environmental Ambient Operating Temp - to 140 F (-20 to 60 C) Ambient Storage Temp - to 18 F (-20 to 8 C) Relative Humidity % to 9% non-condensing (Nema 1) Motor Protection Adjustment / Description Default Setting Overload Current Setting Range 1-40A Per FLA Overload Trip Class Adjustable: Class 10 or 20, Trip current = 11% of FLA setting Class 10 Cycle Fault Trip if cycle rate exceeds 20 starts/minute Always On Stall Trips within 0. seconds (disabled during startup) Always On Smartstart Protection Adjustment / Description Default Setting Current Phase Unbalance Trips within 3 sec @ 2% current unbalance. *Trip threshold changes to 80% unbalance when switched to Off Locked Rotor Trips within 0. seconds Out of Calibration On/Off Trips after 10 seconds if the FLA dial setting is incorrect (set above calculated FLA range), ie. Start current is outside of an acceptable range (fla setting * < inrush < fla setting * 14). On Max Time to Start Regardless of FLA or I 2 t curve, always trip at start if starting current is outside of an acceptable range (inrush / ) and still decreasing after 10 seconds.

6 UL TYPE 1 INDOOR ENCLOSURE STANDARD MOTOR STARTER - 3 Phase, 200~600 VAC Three Phase HP 200V 230V 460V 600V NEMA Size ISS Part Number 1 1. 3 7. 00 ISS1-9/P-40 3 10 1 0 ISS1-18/P-40 7. 10 20 2 1 ISS1-32/P-40 10 10 30 30 1P ISS1-40/P40 UL TYPE 3R OUTDOOR ENCLOSURE STANDARD MOTOR STARTER - 3 Phase, 200~600 VAC Three Phase HP NEMA Size ISS Part Number 200V 230V 460V 600V 1 1. 3 7. 00 ISS3R-9/P-40 3 10 1 0 ISS3R-18/P-40 7. 10 20 2 1 ISS3R-32/P-40 10 10 30 30 1P ISS3R-40/P-40 UL TYPE 4 INDOOR/OUTDOOR ENCLOSURE STANDARD MOTOR STARTER - 3 Phase, 200~600 VAC Three Phase HP NEMxA ISS Part Number 200V 230V 460V 600V Size 1 1. 3 7. 00 ISS4-9/P-40 3 10 1 0 ISS4-18/P-40 7. 10 20 2 1 ISS4-32/P-40 10 10 30 30 1P ISS4-40/P40 *Consult factory for NEMA 4X enclosure options UL TYPE 1 INDOOR ENCLOSURE COMBINATION MOTOR STARTER - 3 Phase, 200~600 VAC Three Phase HP NEMA ISS Part Number 200V 230V 460V 600V Size 3/4 3/4 ISS1-9/P-G1.6-40 1/2 1/2 1 1. ISS1-9/P-G2.-40 3/4 3/4 2 3 00 ISS1-9/P-G4-40 1 1. 3 3 ISS1-9/P-G6-40 2 2 ISS1-9/P-G8-40 2 3 7. UL TYPE 3R OUTDOOR ENCLOSURE COMBINATION MOTOR STARTER - 3 Phase, 200~600 VAC Three Phase HP NEMA Size ISS Part Number 200V 230V 460V 600V 3/4 3/4 ISS3R-9/P-G1.6-40 1/2 1/2 1 1. ISS3R-9/P-G2.-40 3/4 3/4 2 3 00 ISS3R-9/P-G4-40 1 1. 3 3 ISS3R-9/P-G6-40 2 2 ISS3R-9/P-G8-40 2 3 7. 3 3 7. 10 0 ISS3R-18/P-G13-40 UL TYPE 4 OUTDOOR ENCLOSURE COMBINATION MOTOR STARTER - 3 Phase, 200~600 VAC Three Phase HP 200V 230V 460V 600V 3/4 3/4 NEMA Size ISS Part Number ISS4-9/P-G1.6-40 1/2 1/2 1 1. ISS4-9/P-G2.-40 00 3/4 3/4 2 3 ISS4-9/P-G4-40 1 1. 3 3 ISS4-9/P-G6-40 2 2 ISS4-18/P-G8-40 2 3 7. ISS4-18/P-G10-40 0 3 3 7. 10 ISS4-18/P-G13-40 3 10 1 ISS4-18/P-G17-40 7. 1 20 ISS3R-18/P-G10-40 3 10 1 ISS3R-18/P-G17-40 7. 1 20 ISS1-18/P-G10-40 3 3 7. 10 0 ISS1-18/P-G13-40 3 10 1 ISS1-18/P-G17-40 7. 1 20 ISS1-32/P-G22-40 7. 7. 1 20 1 ISS1-32/P-G26-40 7. 10 20 2 ISS1-32/P-G32-40 10 10 30 30 1P ISS1-40/P-G40-40 ISS3R-32/P-G22-40 7. 7. 1 20 1 ISS3R-32/P-G26-40 7. 10 20 30 ISS3R-32/P-G32-40 10 10 30 30 1P ISS3R-40/P-G40-40 ISS4-32/P-G22-40 7. 7. 1 20 1 ISS4-32/P-G26-40 7. 10 20 30 ISS4-32/P-G32-40 10 10 30 30 1P ISS4-40/P-G40-40 www.franklin-controls.com 1.800.962.3787

ISS (1/3R) WIRING SCHEMATICS ISS(1/3R) CONTROL WIRING 10 1 20 2 1 30 Remote Run Voltage Inputs Shut Down 12-20VAC/DC Input 12-20VAC/DC Input ISS STARTER POWER WIRING FLA (A) 40 3 Overload Setting Relay Outputs Status Common Fault OL Keypad PCB Power Pilot Devices Dry Input Actuator Control Coil Start Remote Remote Run Motor Limit Switch A1 A2 Closed Input 24VDC, 1A Output 24V Output to contactor coil M MCP (Optional) H1 H4 200-600 VAC Input L1 L2 L3 M 43 31 44 32 T1 T2 T3 AUX CONT MTR H1 H4 3PH UL TYPE 1 DIMENSIONS All dimensions are in inches 7 7/16 1/4 MTG 1 MTG 1 11/16 6 9/16 6 1/8 UL TYPE 3R DIMENSIONS All dimensions are in inches 7 /8 13 9/16 14 1/8 6 3/8 8 1/16 7

ISS4 Wiring Schematics ISS4 CONTROL WIRING 10 1 20 2 1 30 Remote Run Voltage Inputs Shut Down 12-20VAC/DC Input 12-20VAC/DC Input ISS STARTER POWER WIRING FLA (A) 40 3 Overload Setting Relay Outputs Pilot Devices Dry Input Start Remote Remote Run Status Common Fault STOP START REMOTE X X MCP (Optional) OL H1 H4 M 43 31 Keypad PCB Power Actuator Control Coil Motor Limit Switch A1 A2 G M A+ A- 24V Output to contactor coil 24VDC, 1A Output 200-600 VAC Input L1 L2 L3 44 32 T1 T2 T3 AUX CONT MTR H1 H4 3PH UL Type 4 Dimensions All dimensions are in inches Non-combination* 10 7/16 7 MTG. 12 /16 11 MTG. Combination* 6 11/16 7 /8 6 11/16 8 3/8 *Consult factory for NEMA 4X enclosure options *Combination dimensions are the same as noncombination dimensions except for the depth (shown above, 8 /8 ). 8