C2 NerveMonitor Intraoperative Neuromonitoring

Similar documents
C2 NerveMonitor Intraoperative Neuromonitoring

Advancing medical technology to help you, help others.

Flow Sensor SONOFLOW CO.55

Electrotherapy with up to 16 different current forms over 2 com- ment for electrotherapy. The Endomed has sixteen different types of

iworx RA-834 Recorder

CONTINUING A TRADITION OF PROVEN TECHNOLOGY

Lifelines Neuro-diagnostic accessories catalogue for 2012

Verity Medical Ltd. Designer and Manufacturer of NeuroTrac devices. Rehabilitation Pain Management Wellness. Developed and Manufactured in the UK

ulrich medical Tourniquets

ulrich medical Tourniquets

Accessories Catalog. Neurodiagnostics

PROFITEST. Testing Protective Measures MASTER TESTER INSTALLATION

ulrich medical Tourniquets

810 nm. 980 nm FOX nm 12 W VERSATILE FOX 810/980/ 1064/1470 nm IDEAL FOR: DENTAL ENT DERMATOLOGY GYNECOLOGY SURGERY / VET.

Digital EEG System Series

MODEL 9250 Preliminary data sheet

User manual v 1.1. Single channel EMG logger

Neurodiagnostics Accessories Catalog 2008

APPENDIX E: IWX3XX HARDWARE MANUAL

AP 701 Access Panel. Features and Functions

MInIMAT-ec. flexible data recording highly accurate

experience a New KiNd of flexibility.

MSI Safety Devices PRODUCT INFORMATION

MINIMAT-EC-Servo Screwdriver Spindles

Appendix F: Design Documentation for multisensory therapy system

ENT /2018-E TELE PACK X LED. New Dimensions in LED Stroboscopy

Urology HF SURGERY SETS

MInIMAT-Ec. flexible data recording highly accurate

HP4 headphone amplifier. user manual

OPMI Sensera /S 7 System Step into the light

FOX DIODE LASER. Power Calibration at Fiber Distal Tip Green Aiming Beam Video Touch Screen Intuitive Handling Rapid Amortization

See the Brilliance OR1 HD

MSI 100, MSI 200 Programmable Safety Controllers

Neurodiagnostics. Accessories Catalog EMG EP EEG PSG

Company profi le 4. Quattrocento 12 accessories 14 elettrodes 17

Amendment No. 02. Ref: (i) Tender No: HITES/PCD/AIIMS-BBSR/04/18-19 dated Section I Notice Inviting Tenders(NIT)

DIS-2 series Decentralised servo drive

DIS-2 series Decentralised servo drive

N8000. Electro-Voice N8000. Full IRIS-Net Software Support. 32-Channel Digital Matrix Bus. 115 db Dynamic Range

GT Mini Installation Guide. 30 March 2015

IX-228/S Data Acquisition Unit

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

4 x 6 colors (Red, Green, Black, White, Yellow, Blue). Shelf life for unopened pouches is 36 months. Sterilization: EtO

S7 / OPMI Sensera. OPMI Sensera from ZEISS Compact performance

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Contents LARYNGOSCOPES. HD Laryngoscope Rigid Laryngoscopes...ENR-105 ENR-110. Telescopes for Larynx Surgery...ENR-125 SINUSCOPES

ALL-IN-ONE TMJ Arthroscope

Stance analysis Gait analysis Running analysis Foot scan

ULTRASONIC FLAW DETECTOR SONOSCREEN ST10 FOR NONDESTRUCTIVE TESTING MADE IN GERMANY

MINIMAT-EC. Handheld Screwdriver electric

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Stepper Motor Driver Board. Instruction Note

ACU6. Technical Reference Manual. Specifications Interfacing Dimensions. Document topics. ANSARI Controller Unit Type 6 technical reference manual

Aesculap Electrosurgery Nelson deluxe. Innovative electrosurgery

TETRIS 2500 High Impedance Active Probe. Instruction Manual

NEUROWERK EEG EMG. reliable flexible efficient.

Neuromaster MEE Intra-operative monitoring system

The VoiceArrest System

Hysteroscopy HF SURGERY SETS

MINOP InVent. Offering more for patients through less invasive techniques. Aesculap Neurosurgery

HDM97BP HDM97BO HDM97BN

ELECTRODES & ACCESSORIES. e c

MINIMAT-EC-Servo Screwdriver handheld

McCULLOCH. Micro-Discectomy Instruments The premium neurospine retractor system / / / / / / / / / /

PRODUCT SHEET. 40HP Monaural Headphones OUT01E Foam Ear Inserts: LED

HEMOSTASIS Solutions for Effective Hemostatic Therapy.

Medical Rail Systems 147

NEW - Quick Mode - The revolutionary way to simplify measurement!

A NEW ERA IN SLEEP DIAGNOSTICS

CATALOGUE OF ACCESSORIES 2018

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Data sheet FC-9 DSP system controller. Amp Contoller-Series DSP-Amplifiers + DSP-Controller.

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

CHAT 50 Personal Speakerphone. Quick Start Guide

Functional description

PROFITEST INSTALLATION

SINCOS. Linear Stepper Motor Power Stage. Manual 2066-A006 GB

Minimum < 0.2 ms, maximum 2 ms, typical 1 ms; On request: Delays or holding times for bubble events % relative humidity (not condensing)

NEUROWERK EEG EMG. reliable flexible efficient.

Simplicity + safety = success

KARL STORZ AIDA. Advanced Image and Data Acquisition. Exceptional documentation. Record. Edit. Checklist. Complete. Patient.

EQUALIZER BACKGROUND. PRE-AMP Line Driver

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Product Information. ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200

MADI-PC MADI RECORDING SYSTEM

Technical Article. EMC f ilters for medical devices

ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual

We take care of it. Mobile Power Quality Analyzers. PQ-Box 100/150/200. Accessories

Table of Contents. Lucas Nülle GmbH Page 1/9

Marshall Electronics. AR-AM4-BG Analog Audio Monitor. Operating Instructions

4-Channel Vibration Datalogger

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Hysteroscopes from KARL STORZ

Sheath E-Line 8,5 Fr, With Obturator For 1 Urethrotome

Classis RM 30 Classis RM 31

Screwdriver Spindles electric. The flexible EC screwdriver for the highest standards. Screwdriving Technology Automation Air Motors Air Tools

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Interfaces Service and Field

Magstim Rapid MAGSTIM RAPID 2 P/N OPERATING MANUAL

Transcription:

C2 NerveMonitor Intraoperative Neuromonitoring Applications Thyroid Surgery Facial Nerve Monitoring Ear, Nose and Throat Surgery Skull Base Surgery Peripheral Nerve Surgery Spine Surgery

2 inomed Hitting the Nerve inomed is a medical technology company, operating internationally, which develops nerve protection instruments and systems for precisely targeted patient treatment. Sharing Knowledge Working with doctors and users, inomed develops new tools and methods in the fields of intraoperative neuromonitoring, neurosurgery, pain therapy and neurological diagnostics. Providing Safety inomed improves treatment outcomes with high-quality products and uses innovative technologies to ensure safety for both treatment providers and patients.

3 Product Overview C2 NerveMonitor Art. no. 508 240 (4 EMG channels) Art. no. 508 280 (8 EMG channels) Safe Nerve Monitoring with Visual Feedback The C2 NerveMonitor is the result of inomed's years of experience in the field of nerve monitoring. It is available as a four or eight channel EMG monitor with high performance differential amplifiers and two independent stimulators: one for direct nerve stimulation with hand held probes and one for continuous monitoring e.g. with the V3 vagus electrode. Designed for daily use in the operating room, the C2 Nerve- Monitor can be easily used after a brief introduction. It combines simplicity with visual feedback. All components of the device have been optimised for safe neuromonitoring in order to achieve the highest quality of signal and feedback.

4 Versatile and Portable Fields of Application Thyroid operation using a disposable stimulation probe User-friendly control concept with audio and visual feedback Audio and Visual Feedback with Electrode Check During surgery, a sound compressor ensures good acoustic reproduction of the EMG signal over a speaker. Visual feedback is given via a graphical representation of the muscle response signal. The amplitude and latency of the signal can be seen clearly. Up to eight EMG curves can be shown simultaneously on the display. Correctly placed electrodes are controlled automatically with an electrode check or impedance measurement. 4 differential EMG channels (article no. 508 240) 8 differential EMG channels (article no. 508 280) Monitoring Programs and Applications All relevant parameters have been set in predefined programs. Additionally, a program can be created for each surgical procedure and the user can select from these customised programs. All important stimulation and recording parameters can be saved and adjusted to the userʼs preferences for defined surgical procedures. If required, the factory settings can be reset. The C2 NerveMonitor can be used in the following fields among others: Current Sensor Technology The auto mute function of inomed devices was further developed and improved for the C2 NerveMonitor. The loudspeaker is activated only during stimulation, while noise and coagulation artefacts are suppressed with the mute functions. In addition, the sensitivity of the auto mute function can be adapted. Together these functions represent an easy possibility to perform stimulation. thyroid surgery ear, nose and throat surgery facial nerve and parotid surgery removal of the acoustic neuroma spine surgery, e. g. pedicle screw test and many further areas The C2 NerveMonitor should be used wherever motor nerves are at risk.

Excellent Results at Every Monitoring Product Features 5 Selection of recordings Print preview Stimulation probe and V3 electrode in action Patient Management and Bar Code Scanner At the beginning of an operation, a unique patient ID is created automatically or is read by the integrated bar code scanner. All important patient information is saved continuously during an operation. Every muscle response is stored in a database for later analysis. During an operation, a response potential can be preselected by pressing a footswitch. Printing out allows a comfortable review for the selection of signals for documentation. Data can be conveniently exported to various formats. Interfaces and Accessories The front of the C2 NerveMonitor is equipped with touchproof connections for stimulation and recording. For patient data export, a USB port is integrated on the side of the device. A mute sensor can be connected to the back for suppression of coagulation artefacts. Ports for an external monitor, a network cable and a trigger for stimulation are also provided. Furthermore, an inomed recommended printer and inomed module can be connected for expansion of functionality. A wide range of disposable and reusable accessories is available for the C2 NerveMonitor, so that the device can work according to the maxim Switch on, measure and protect. Bar code scanner reading patient data

6 Recommended Accessories Accessories Art. no. 540 415 (2 channel) Art. no. 540 425 (4 channel) EMG electrodes mini box with ground, 4 x 1.5 mm or 8 x 1.5 mm touchproof connectors DIN 42802, cable 4 m Art. no. 508510 Channel Select Software-Module To make best use of the adhesive laryngeal electrode Select we recommend the use of the software module Channel Select for the C2 NerveMonitor. Recording Art. no. 530 626 (10 pieces) 2 Subdermal needle electrodes cable 1.2 m, needle 20 mm with 1.5 mm touchproof connectors red/black (universal applications) Art. no. 530 627 (10 pieces) Subdermal needle electrode cable 1.2 m, needle 20 mm with 1.5 mm touchproof connector green (ground electrode) Art. no. 530 655 (10 pieces) inomed adhesive laryngeal electrode for tube of 6 7 mm inner diameter adhesive surface width 29 mm Art. no. 530 656 (10 pieces) for tube of 7.5 9 mm inner diameter adhesive surface width 37 mm length 32 mm, with ground adhesive electrode Art. no. 530 667 Connecting cable for laryngeal electrodes cable 4 m, channel 1 and 2 with ground, bend protection: blue delivered non-sterile can be disinfected Art. no. 530 856 (10 pieces) Laryngeal Electrode Select for tube of 7.5 9 mm inner diameter adhesive surface width 37 mm length 32 mm, with ground adhesive electrode Art. no. 530 867 Connecting cable for Laryngeal Electrodes Select cable 4 m, 4 channel differential with ground, bend protection: blue delivered non-sterile can be disinfected Art. no. 530 666 (10 pieces) Disposable electrode for vocal muscle bipolar, with ground electrode, needle length 15 mm, 30 angled, 1.5 mm touchproof connectors red/black/green, round cable 1.5 m, individually packaged

Accessories and Technical Data 7 Stimulation Probes Art. no. 522 603 (10 pieces) Bipolar concentric stimulation probe, length 4.5 cm angled, for direct nerve stimulation, cable 3 m, instrument total length with handle 15.5 cm Art. no. 522 610 (10 pieces) Microfork probe, length 4.5 cm straight, bipolar, for direct nerve stimulation, cable 3 m, instrument total length with handle 15.5 cm Continuous Vagus Stimulation Minimally Invasive Procedure Art. no. 522 200 V3 Tripolar stimulation electrode for the vagus nerve Work piece: outer diameter 5 mm, length 21 mm, contact ring: width 3 mm, with 4 pole male connector, cable length 40 cm delivered non-sterile autoclavable Art. no. 522 128 Bipolar concentric stimulation probe, length 31 cm, straight for direct nerve stimulation, total length with handle 41.5 cm, work length 310 mm, diameter 1.3 mm delivered non-sterile autoclavable Technical Data of the C2 NerveMonitor Recording Frequency range Measuring range Precision Stimulator Stimulation frequency Pulse Stimulation current Stimulation voltage Current sensor 4 8 differential EMG inputs Selectable in range 0.5 5000 Hz 80μV - 800mV 16 Bit with 20 khz sampling rate 2 independent stimulation channels Freely selectable in range of 1 30 Hz Negative, 200 μs pulse width Constant current, 0.01 ma to max. 25 ma Max. 100 V For display of current flow Connections Three USB ports: one on the side and two on the rear Optional connection of two inomed USB modules possible Mute sensor for suppression of coagulation artefacts VGA outlet for connection of a second monitor Network connection with 100 MBit LAN/Ethernet 4 x Trigger In / 4 x Trigger Out (programmable) Certified in accordance with DIN EN ISO 13485:2003 0297

inomed Medizintechnik GmbH Im Hausgruen 29 79312 Emmendingen (GERMANY) Tel.: +49 7641 94 14-0 Fax: +49 7641 94 14-94 info@inomed.com www.inomed.com 1000508 E/2.1 Content subject to alterations copyright by inomed 07.2011