X-RiteColor DTP34 QUICKCAL DENSITOMETER. Users Manual

Similar documents
SPECTROPHOTOMETER. Getting Started

User Guide. Ci51/Ci52 Spectrophotometer

MetaVue. User Manual. VS3200 Spectrophotometer. P/N VS Rev. A

Ci4200/Ci4200UV Spectrophotometer. User Guide

Model VS /0 Color Spectrophotometer. Operator s Manual

CRx Printers START-UP GUIDE

X-Rite MA48. Multi-Angle Spectrophotometer. Operator s Manual

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved.

1.0 Description. 2.0 Unpacking. 3.0 Installation

YJ Carat and Gold Scales

Series. C Series Quick Start Guide. English. One Printer for your Entire Enterprise.

CANADIAN D.O.C. WARNING

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

EZ-LP Quick Start Guide

3M RFID Tracking Pad Model 770

INSTALLATION GUIDE ADAPTEC SCSI CARD ULTRA160 SCSI CONTROLLER

Quick Start Guide. Sabre 1400 Hand-held Scanner

ADL-100 Operator s Manual

Power TracKer VII. User s Manual 2006 AVID. Multi Mode Reader. Manufactured under one or more of the following Patents:

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

TT230SM THERMAL TRANSFER PRINTER USER S MANUAL

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

WILDCAT REALIZM 800 WILDCAT REALIZM 500 WILDCAT REALIZM 200 WILDCAT REALIZM 100

LabelMax SP2 User Manual

68-pin Internal Ultra160-LVD Connector. Adaptec SCSI Card 29160N

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C

Messager USB w/ Night Answer

Sonorous v2.0. Installation & User Manual

VIS-3102 Installation Manual

Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

ilink Installation & User Manual Internet Downloadable MP3 Music & Message Series

Installing the ipower 70 Room Camera

CHS 7Ci. Bluetooth Cordless Barcode Scanner. Quick Start Guide

BD FACSMelody Cell Sorter Installation and Security Guide

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

SNMP/Web Management Accessory Card Model: SNMPWEBCARD

User Guide. HAWKEYE CLASSIC VIDEO BORESCOPES (Non-Articulating) Hawkeye Classic Video Borescope. Hawkeye Classic Video Borescope - Set Up

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

Unpacking. Installation

Eltron LP 2348 Eltron 2348 ADV

Operator s Handbook. Monarch FreshMarx 9417 Food Freshness System. TC9417OH Rev. AE 1/ Avery Dennison Corp. All rights reserved.

2001BRF & 2001URF. Wireless Keyboard & Mouse Kit. User s Guide

udynamo Troubleshooting Reference Manual PART NUMBER D October 2014

2DScan TM Barcode Scanner

IFS NS3552-8P-2S and NS3550-2T-8S Quick Installation Guide

CAUTION: Before installing the Windows or Macintosh operating system, see our knowledge base answer ID 1485 for precautionary procedures.

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller

Table of Contents. Unpacking and Inspection Setup Loading the Media Mount the Printer on the Wall... 16

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

Safety and Radio-Frequency Interference

R E M O T E I/O C O N C E N T R A T O R. Installation Guide

Owner's Manual. For latest instructions please go to

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide

2001ARF. Wireless Keyboard & Mouse Kit. User s Guide

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

MA 3 Spectrophotometer. User Guide

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

USB 3.0 Spectra

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

elise 3 embedded linux server including safety instructions

ESA SERIES ELECTRONIC BALANCE

CANADIAN D.O.C. WARNING

Users Manual OPN Pocket Memory Scanner

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER MANUAL. Elo Touch Solutions 2D Barcode Scanner Peripheral

USER GUIDE. Laptop Charger NS-PWLC591/NS-PWLC591-C. Before using your new product, please read these instructions to prevent any damage.

Contents. 1 Introduction. 2 Setting up PC scanning. 3 Connecting to the copier. 4 Installing the TWAIN driver

MW-145BT Mobile Printer

MONOPRICE. Bluetooth Over-the-Ear Headphones with External Speakers. User's Manual. Model 15276

Multi-Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

User Manual. Network Interface Card (NC-6)

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Support for Non-Ultra2 SCSI Devices

Installer/User Guide

Channel Switch CS. General Operating, Maintenance and Installation Manual

Nano Laptop Laser Mouse

WAVECOM INSTRUMENTS PTY LTD

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Standalone Voice/IP Gateway Model MVP110. Proprietary Mode. Quick Start Guide

2 Mesa Ethernet Dock User s Manual

Controller Specifications

DATALOCKER H100 ENCRYPTED HARD DRIVE. User Guide

TC100 Precision Thermocouple Calibrator

USB 2.0 Ranger High Speed Extender System. User Guide

Kramer Electronics, Ltd. USER MANUAL. Model: VM-50AN. 1:5 Audio Distributor

SubCast Transmitter/Receiver Subwoofer Kit

BEETLE /Fusion Compact. Installation Guide

iq 16 Sync Charge Box

USER MANUAL Mousing Comfort in the Palm of Your Hand

Installation & User s Guide

IFS NS3550-8T-2S Quick Installation Guide

Temperature & Humidity Datalogger

Monarch 939i Intelligent Keyboard

2D Image Handheld Scanner

Longshine Technologie Europe GmbH

Transcription:

X-RiteColor DTP34 QUICKCAL DENSITOMETER Users Manual

CE DECLARATION Manufacturer's Name: Manufacturer's Address: Model Name: Model No.: Directive(s) Conformance: X-Rite, Incorporated 4300 44 th Street, S.E. Grand Rapids, Michigan U.S.A. Densitometer DTP34 EMC 89/336/EEC LVD 73/23/EEC WEEE As of August 13, 2005, X-Rite products meet the European Union Waste Electrical and Electronic Equipment (WEEE) directive. Please refer to www.xrite.com for more information on X-Rite s compliance with the WEEE directive. Federal Communications Commission Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. NOTE: Shielded interface cables must be used in order to maintain compliance with the desired FCC and European emission requirements. Industry Canada Compliance Statement This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. AVERTISSEMENT : Des câbles d'interface blindés doivent être utilisés afin de se conformer aux règlements européens et FCC (USA)sur l'émission. Proprietary Notice The information contained in this manual is derived from patent and proprietary data of X-Rite, Incorporated. The contents of this manual are the property of X-Rite, Incorporated and are copyrighted. Any reproduction in whole or part is strictly prohibited. Publication of this information does not imply any rights to reproduce or use this manual for any purpose other than installing, operating, or maintaining this instrument. No part of this manual may be reproduced, transcribed, transmitted, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, magnetic, mechanical, optical, manual, or otherwise, without the prior written permission of an officer of X-Rite, Incorporated. This product is covered by one or more of the following U.S. Patent: 4,591,978 5,015,098 5,062,714 6,262,804 and patents pending. Foreign patent numbers provided on request. Copyright 2007 by X-Rite, Incorporated ALL RIGHTS RESERVED X-Rite is a registered trademark of X-Rite, Incorporated. All other logos, brand names, and product names mentioned are the properties of their respective holders. Warranty Information X-Rite, Incorporated ( X-Rite ) warrants each instrument manufactured to be free of defects in material and workmanship (excluding battery pack) for a period of 12 months. This warranty shall be fulfilled by the repair or replacement, at the option of X-Rite, of any part or parts, free of charge including labor, F.O.B. its factory or authorized service center. This warranty shall be voided by any repair, alteration, or modification, by persons other than employees of X-Rite, or those expressly authorized by X-Rite to perform repairs, and by any abuse, misuse, or neglect of the product, or by use not in accordance with X-Rite s published instructions. 1

X-Rite reserves the right to make changes in design and /or improvements to its products without any obligation to include these changes in any products previously manufactured. Correction of defects by repair or replacement shall constitute fulfillment of all warranty obligations on the part of X-Rite. THIS WARRANTY IS EXPLICITLY IN LIEU OF ANY OTHER EXPRESSED OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. THIS WARRANTY OBLIGATION IS LIMITED TO REPAIR OR REPLACEMENT OF THE UNIT RETURNED TO X-RITE OR AN AUTHORIZED SERVICE CENTER FOR THAT PURPOSE. This agreement shall be interpreted in accordance with the laws of the State of Michigan and jurisdiction and venue shall lie with the courts of Michigan as selected by X-Rite, Incorporated Table of Contents Overview and Setup 3 Instrument Description 3 Unpacking and Inspection 3 Instrument Interface 4 USB Driver Installation (Windows Only) 4 Instrument LED Indicator 5 Calibration 6 Frequency of Calibration 6 Positioning the Instrument on the Calibration Reference 6 Quick Calibration 6 Full Calibration 6 Measurements 7 Measurement Notes and Tips 7 Strip Measurement 8 Spot Measurement 9 Troubleshooting and Service 10 Troubleshooting 10 Instrument Reset 11 Service Information 11 General Maintenance 12 Cleaning the Instrument 12 Cleaning the Reflection Reference 12 Instrument Specifications 14 Appendix A - Operational considerations between a DTP32R and a DTP34 16 Operation 16 Appendix B - Barcode Operation 17 2

Overview and Setup Instrument Description X-RiteColor DTP34 QuickCal Densitometer is a color measurement instrument that reports densitometric and dot data. The instrument is designed to calibrate color output devices including large format printers, proofers, and digitally connected color copiers. X-RiteColor DTP34 QuickCal Densitometer is a drop-in replacement for the X-Rite DTP32 instrument. This manual covers the installation, calibration and maintenance of the X-RiteColor DTP34 QuickCal Densitometer. Specific instructions for using the instrument with your third-party software program can be found in the third-party software documentation. As the DTP34 QuickCal Densitometer is designed to be a drop-in replacement for the DTP32 Automatic Strip Reading Densitometer, reflection versions, it will by default report itself as a DTP32. Most existing software packages will reference a DTP32 in their connection menu while newer software may use DTP34. Select DTP34 if it is available, otherwise select the DTP32. Refer to Appendix B for further differences. See the Readme file on the CD for any late changes or known issues. Three Color LED Indicators Read Button Centerline Alignment Mark Interface Cable Connection Centerline Alignment Mark Center Notch Unpacking and Inspection After removing the instrument from the shipping carton, inspect it for damage. If any damage has occurred during shipping, immediately contact the transportation company. Do not proceed with installation until the carrier s agent has inspected the damage. Your instrument was packaged in a specially designed carton to assure against damage. If shipment is necessary, the instrument should be packaged in the original carton along with all the accessories. If the original carton is not available, contact X-Rite to have a replacement shipped to you. 3

Instrument Interface The Quick Cal Densitometer must be interfaced directly with one of the computer s Serial or USB ports. For attachment to a Mac Mini-DIN 8 Serial Port, you need to use the optional adapter (P/N SE108-DB9PA-01). 1. Quit all programs and shut down the computer before installing interface cabling. 2. Connect appropriate interface cables as shown. CAUTION: Use only the 115V/230V Switching Power Supply (SE30-87) to power the instrument. 3. Plug the small end of the switching power supply into the power input connector of the interface cable. 4. Plug the detachable line cord into the power supply and then into the AC wall receptacle. The instrument does not have a ON/OFF switch. SE30-87 Switching Power Supply Detachable Line Cord (optional) AC Wall Receptacle Power Input Locking Connector Operation Grasp and push the connector at this location to insert. Grasp and pull the connector at this location to remove. USB SE108-96-02 Interface Cable SE108-97-02 Interface Cable PC DB9 SE108-DB9PA-01 (Optional) MAC Mini-DIN 8 USB Driver Installation (Windows only) A USB driver must be install in the computer to allow the instrument to work with your software application if the USB interface cable is used. Follow the steps below to install the required USB driver. 1. Make sure the switching power supply is plugged into the instrument and the computer in on. 2. After the USB cable is plugged into your computer, you must install the USB driver that came with your instrument. 3. The USB driver is located in the Driver folder on the DTP34 Manuals and Utilities CD. 4

Instrument LED Indicator The LED indicates a variety of instrument operation conditions, such as calibration mode, and operation. Below is a complete list of all conditions reported by the LED. Operation Mode Solid Green self-test passed and instrument is ready for use with defined strip. Slow Flashing Green strip reading in progress or waiting to read a strip. Fast Flashing Green strip reading was attempted but the wrong strip was read, or strip was skewed during reading. Flashing Amber/Green a configuration barcode was scanned and the instrument is waiting for the 2 nd or 3 rd barcode pass. Fast Flashing Amber/Green there was an error in recognizing a barcode or the configuration failed. Reread the entire barcode, starting with the first pass. Calibration Mode Solid Amber calibration is required before any measurements can be taken. Slow Flashing Amber instrument calibration in progress (strip being read). Solid Green after Amber instrument calibration was successful and instrument is ready for use. Error/Reset Mode NOTE: When the instrument is first turned on the LED will be red while it performs its self-tests. The selftests will complete in approximately 2 to 3 seconds, at which time it will turn green under normal conditions. Fast Flashing Red incorrect power supply attached. Verify correct 12-volt power supply is used. Slow Flashing Red a factory reset is in progress. Flashing Red/Green the host firmware loader program is reprogramming the instrument. 5

Calibration The X-RiteColor Quick Cal Densitometer has a unique semi automatic calibration feature. When the reflection reference is scanned, the calibration values are also automatically scanned. Frequency of Calibration Your QuickCal Densitometer should have a Quick Calibration performed weekly. A Full Calibration should be performed annually, during heavy usage to provide accurate measurements, or if the Quick Calibration consistently fails. Typically, the host computer prompts for an instrument calibration (amber LED) when required but the process can be invoked manually at any time. Refer to the following procedure for details on the calibration process. Positioning the Instrument on the Calibration Reference Handle the reflection reference by the edges. Make sure that the reflection reference is free of dust, dirt and smudgemarks. Refer to General Maintenance Section for cleaning procedure. Always store the reflection reference in it protective envelope away from light and heat. NOTE: To obtain the most accurate calibration, hold the instrument with consistent and nominal pressure during the calibration procedures. Position the instrument on the designated location of the reflection reference (indicated by a dotted outline of the instrument). Do Not move the instrument more than.25 (6.35mm) before reading the strip. DTP34-100 Reflection Reference Quick Calibration A quick calibration can be performed at any time. All that is required is that you scan the reflection reference as you would with any other strip. A quick calibration should only be performed after a full calibration has been done. The instrument comes from the factory with a full calibration already stored. 1. Position instrument on reference as previously mentioned. 2. Press and hold the button and scan the reference to the opposite end. Release the button. The LED should indicate green if calibration was successful. If calibration fails, (fast flashing amber LED), verify the strip is clean and re-read. 3. Place the reflection reference in its protective envelope and store away from light and heat. Full Calibration NOTE: If the host computer initiated calibration (amber LED), skip to step 2. 1. To manually invoke the calibration mode, press and hold the instrument button for a minimum of three seconds. The LED will slowly flash amber when calibration is initiated. 2. Press and the hold button (if not previously held) and scan the reference to the opposite end. Release the button. The LED should indicate green if calibration was successful. If calibration fails, (fast flashing amber LED), verify the strip is clean and re-read. 3. Place the reflection reference in its protective envelope and store away from light and heat. 6

Measurements Measurement Notes and Tips You should refer to the documentation for the software program that you are using with your instrument. All applications that utilize this instrument must be running during measurements. The strip must have at least a 1.2 (30.5mm) leader before the leading edge of the first step. Contact X-Rite Applications Support if additional information is required. Inspect the strip for spots or defects on the steps. Defects may cause inaccurate measurements. If a strip does not have the necessary 1.2 (30.5mm) unprinted leader before the first patch or a reading would cause one or more of the wheels to be off the sample, follow the steps listed below: 1. Obtain extra pieces of the sample stock. 2. Position the pieces so that all four wheels of the instrument ride along the same height stock when patches are measured. INCORRECT: Wheels off the edge of the paper. SOLUTION: Place extra stock here. INCORRECT: Wheels off the edge of the paper or insufficient leader. SOLUTION: Place extra stock here. 7

The darkest patch of a strip must be read first unless there is at least 1.1 (27.9mm) unprinted trailer after the last patch. When possible, strips should be read so that the instrument does not ride on un-read patches. This prevents accidental marring of un-read patches that may cause reading variations. To obtain consistent measurements the same backer should be used underneath every sample. ANSI/ISO specifies a neutral gray of at least 1.5D, which will appear black. Backers consisting of the same print stock have also been utilized. Strip Measurement The following information is provided to familiarize you with reading strips, a series of printed control patches. 1. Select strip type to measure from the host software. 2. Position the instrument at the leading edge of the strip to be measured. The centering alignment marks should be centered on the strip patches. Centering Alignment Mark Wheel(s) 3. Press and hold the instrument button while rolling the QuickCal across the strip. The LED indicators will slowly flash green during the reading. For best results, pause with the button depressed before starting a scan, and release the button only after the scan has been completed. 4. A successfully reading is verified by a beep and solid green LEDs on the instrument, or a conformation message on the computer monitor. Some software packages define strips as multi-pass where all color passes must be read before a conformation is displayed on the monitor. In these cases, a successful reading of a color pass is shown by the instrument slowly flashing green after the reading. This indicates that you may continue to the next color pass. Fast flashing of green indicates a re-read is required on the pass. The instruments LEDs will stay at solid green after all passes are successfully read. 8

Spot Measurement Your QuickCal Densitometer is designed to read spots, single readings of specific locations. This feature can be manually activated or if supported, activated by your software application. Refer to your software program documentation to see if this feature is supported. To manually activate this feature, scan the Spot Read X-Rite Setup Barcode enclosed. 1. Select a desired target of at least.5 (12.7mm) diameter. 2. Position the instrument to line up the center of the target with the instrument centering alignment marks and center notch. The instrument may be placed or rolled into position over the target. 3. Press and release the instrument button. 4. A successfully reading is verified by a beep and solid green LEDs on the instrument, or a conformation message on the computer monitor. Center Notch Centering Alignment Mark Desired Target,.5 (12.7mm) minimum 9

Troubleshooting and Service Troubleshooting Prior to contacting X-Rite, Inc. Customer Service for instrument problems try the applicable solution(s) described below. If the condition persists contact a Customer Service Representative (see Service Information). LEDs are not lit: Ensure that the power supply is plugged in and connected to the Interface Cable. Insure that the Interface Cable is properly connected to the instrument. Reset the instrument (see Instrument Reset). Fast Flashing Amber LEDs: If error persists, clean instrument and calibration strip (see General Cleaning). Reset the instrument (see Instrument Reset). Solid Amber LEDs: Instrument needs a calibration before any strips can be read (see Calibration section). Solid Red LEDs: Remove power from the instrument, reapply power and see if the condition is corrected. Reset the instrument (see Instrument Reset) and calibrate. This could indicate that the unit may not be programmed properly, which could happen if power was removed during reprogramming. Try reprogramming the instrument again (refer to the programming instructions that came with your update). QuickCal Densitometer and software not communicating: Verify that the instrument LEDs indicate normal operation (see Instrument LED Indicator). If normal, close and restart the software application. If this does not work reboot the computer. Remove power from the instrument, reapply power and see if the condition is corrected. Check for proper configuration setting from the software provider. Reset the instrument (see Instrument Reset) and calibrate. Repeated Strip Measurement Failures: Ensure that the strip is being read in accordance with your software s documentation. Close and restart the software application. Perform a full calibration on the instrument (see Full calibration). Reset the instrument (see Instrument Reset). Repeated Calibration Failures: Clean instrument and reference (see General Maintenance). Reset the instrument (see Instrument Reset) and calibrate. Spot Measurement does not work: Ensure that your software supports the Spot Measurement function. Ensure that the instrument s Spot Read function is turned on. (see Barcode Operation). Reset the instrument (see Instrument Reset). Note: When performing an Instrument Reset, which restores the X-Rite Factory Defaults, you will have to ensure the correct configuration for your software is then restored. 10

Instrument Reset The following procedure will reset the factory defaults to your X-RiteColor QuickCal Densitometer: 1. Disconnect power from the instrument. 2. Push and hold the Read Button while applying power to the instrument. 3. Hold the Read Button until the LEDs begin to flash red slowly. 4. Release the Read Button. Service Information The X-RiteColor Quick Cal Densitometer is covered by a one-year limited warranty and should be referred to an authorized service center for repairs within the warranty period. X-Rite provides repair service to their customers. Because of the complexity of the circuitry, all repairs should be referred an authorized service center. X-Rite will repair any instrument past warranty. The customer shall pay shipping and repair cost to the authorized service center, and the instrument shall be submitted in the original carton, as a complete unaltered unit along with all the supplied accessories. 11

General Maintenance Cleaning the Instrument Your instrument requires very little maintenance to achieve years of reliable operation. However, to protect your investment and maintain reading accuracy, a few simple-cleaning procedures should be performed from time to time. General Cleaning Whenever required, the exterior of the instrument may be wiped clean with a cloth dampened in water or mild cleaner. NOTE: DO NOT use any solvents to the clean the instrument, this will cause damage to the cover. Cleaning the Instrument Wheels Turn the instrument upside-down and clean the bottom plate surface and wheels with a lint free cloth. Wheels Bottom Plate Surface Wheels Cleaning the Instrument Optics and Locating Wheel Carefully rotate instrument and blow short bursts of clean, dry air into the measurement aperture and locating wheel. This should remove any accumulated dust in these areas. Measurement Aperture Locating Wheel Cleaning the Reflection Reference The reflection reference can be cleaned with a lint free cloth whenever required. Make sure to return the reference to its protective case when finished. 12

If required, a new calibration reference can be ordered from X-Rite. Order calibration reference part number DTP34-100-KIT. Always handle calibration reference by the edges. DTP34-100 Reflection Reference 13

Instrument Specifications - Preliminary Measurement Geometry Reflection: 0 /45 per ANSI/NAPM 2.17 and ANSI/ISO 5-4 Multi-sensor array Measurement Area 2 mm x 4 mm, 2 mm in the direction of travel. Instrument must set on sample for accurate measurement. Light Source Gas pressure @ 2850 K Lamp file, approx. 1,000,000 scans @ 11 (279.4 mm) Receiver Blue enhanced silicon photodiodes Sample Characteristics Patch Size:.400 (10.16 mm) min. in direction of travel by.350 (9 mm) min. wide. 1 mm wide 1.0D contrast space between patches or.5d min difference between patches. Measurement Rate >6 (>154mm)/sec maximum controlled by operator. System Response ANSI/ISO Status T Output Density, +Dot, -Dot, or Reflectance. Output has x10 capability. Measurement Range 0.00D to 2.50D absolute Linearity ±0.02D or ±2%, 0 to 2.5D Repeatability ±0.01D, 0 to 2.5D Inter Instrument Agreement ±0.02D or 2%, 0 to 2.5D Zero Stability ±0.01D max I/O Connection DB9 socket and USB (future) Data Interface Interface: RS-232 with baud rates from 1200 to 19.2k Protocol: RCI commands Power Requirements +12v @ 700 ma Environmental Operating range: +10 C (50 F) to 35 C (104 F); 30% to 60% RH Physical Height: 4.83 cm (1.90 in.) Width: 6.10 cm (2.40 in.) Length: 11.55 cm (4.55 in.) 14

Weight 165g. (5.8 oz.) Provided Accessories Calibration Reference Operation Manual Interface Cable AC Adapter (P/N SE30-87) Optional Accessories Mac Serial Adapter (P/N SE108-DB9PA-01) 25 Pin Serial Adapter (P/N SE08-231-01) Line Cords For the most recent list of supporting third-party software, see X-RiteColor Enabled Partner literature item L11-031A and L11-031B, or visit www.x-rite.com/support/partners.asp and browse to the Support and Training page. Specifications and design subject to change without notice. 15

Appendix A - Operational considerations between a DTP32R and a DTP34 The DTP 34 Quick Cal Densitometer is a drop in replacement for the X-Rite DTP32R (R for reflective) strip reading densitometer. There are a few differences in operation of the Quick Cal compared to the DTP32. The DTP32 (see diagram at right) has a display, keyboard, and strip guide, whereas the Quick Cal product has a single key and the different process of reading a strip. In order to use the Quick Cal product where a software application expects the DTP32 product, please consider the following. Cal Strip and 35mm Film Entrance Paper and Film Entrance Paper and Film Guide Display Keyboard Serial Interface Connection AC Adapter Input X-Rite DTP32R AutoScan Densitometer Operation Below we list some of the ways that the use of the instruments will differ. The items in italic are phrases often indicated in the host software for the DTP32R. Use of the strip guide Insert strip at X The DTP32R has a strip guide mechanism that ranged numerically from 5 to 30. Some software packages indicate a setting for this guide. These prompts can be ignored with the QuickCal as no guide is required. Inserting as strip Insert Cyan strip When asked to insert a strip, a QuickCal user will then position the instrument at the start of the row to be read, push the measure button and read. For more about reading a strip see the Measurement Notes and Tips section of the Manual. Using the keyboard Push Key #X The DTP32R has four keys to control the menus found on the LCD. The DTP34 does not require unique key sequences, because it is software driven, therefore these prompts can be ignored. Calibration of the instrument Go to page 2 to Calibrate The DTP34 can be calibrated without using menus, as is required for the DTP32 product. A quick calibration can be initiated like any other reading, and a full calibration is initiated by holding the button until the lights turn amber. Please see the calibration section in the manual for a full explanation. Configuration of the instrument Go to page 3 to Configure the Instrument Most software will automatically configure and setup the DTP32R or the DTP34 for use. Often, this equates to selecting from various communications settings so the software can take over control of the instrument once it is connected. For the few packages that require a manual configuration the DTP34 allows manual configuration by reading X-Rite Set-up Barcodes. X-Rite Set-up Barcode pages are supplied on the QuickCal CD-ROM for some manual configurations. Check the third party support folder on the CD-ROM to see if there is a configuration page that contains all the settings for your software package. More information about reading bar codes is found in section 2 of the manual. Further information about Quick Cal and third party support can be referenced at the X-Rite website under the help desk area at the following location: http://www.xrite.com/helpdesk/3psort.asp?rectype=6&id=272 16

Appendix B - Barcode Operation You can change several configuration settings of your QuickCal Densitometer using the special format barcodes supplied by X-Rite, Inc. or your software provider. These set-up barcodes consist of multiple strips that must be read in the proper order. In most cases your software will automatically configure your instrument. If your software or software documentation prompts you to configure your instrument, the enclosed X-Rite Set-up Barcodes contain some commonly used commands that can be scanned immediately to get you up and running. Additional barcode set-up and information is available on the CD that is shipped with your instrument. The LEDs signal the status of the instrument when reading a set-up barcode. While scanning the initial barcode, the LEDs will flash slowly between off and green, the same as any normal scan. Once the unit has recognized the initial barcode as being part of a set-up barcode, the LEDs will slowly flash between yellow and green. This same flash pattern will continue while scanning continuation barcodes. Upon completion of the entire set-up barcode, the LEDs will come on steady green, indicating a successful completion. REFER TO THE FOLLOWING PAGES FOR X-RITE SET-UP BARCODES. CAUTION: Only use the Set-up barcodes if instructed to manually set-up your instrument. This will avoid changing configurations that may cause the QuickCal Densitometer and your software to cease communicating. If this does happen reference the Troubleshooting and Service section. NOTE: To enable the following barcodes to print at their intended size, make sure the Shrink oversize pages to paper size check box is disabled (un-checked) in the Print dialog. If you are using an older version of Adobe Reader (ver. 3 or 4), make sure Fit to Page check box is disabled (un-checked) in the Print dialog. 17

Baud Rate First scan #1, then scan one #2 for the desired setting. #1 #2-1200 #2-2400 #2-4800 #2-9600 #2-19200 18

Autotransmit First scan #1, then scan one #2 for the desired setting. #1 #2 - On #2 - Off 19

Decimal Point First scan #1, then scan one #2 for the desired setting. #1 #2 - On #2 - Off 20

Times 10 First scan #1, then scan one #2 for the desired setting. #1 #2 - On #2 - Off 21

Data After Pass First scan #1, then scan one #2 for the desired setting. #1 #2 - On #2 - Off 22

Delimiter First scan #1, then scan one #2 for the desired setting. #1 #2 Carriage Return #2 Carriage Return and Line Feed 23

Separator First scan #1, then scan one #2 for the desired setting. #1 #2 - Space #2 - Comma #2 - Tab #2 Carriage Return #2 Carriage Return and Line Feed 24

Min/Max First scan #1, then scan one #2 for the desired setting. #1 #2 - Off #2 - Min #2 - Max #2 Min and Max 25

Spot Read Command- First scan barcode #1, then scan ONE of the subsequent to enable or disable spot reading capability: Barcode #1: Spot read: Enable Disable 26

Corporate Headquarters - USA 4300 44th Street SE Grand Rapids, Michigan 49512 Phone 1 800 248 9748 or 1 616 803 2100 Fax 1 800 292 4437 or 1 616 803 2705 Corporate Headquarters - Europe Althardstrasse 70 8105 Regensdorf Switzerland Phone (+41) 44 842 24 00 Fax (+41) 44 842 22 22 Corporate Headquarters - Asia Room 808-810 Kornhill Metro Tower, 1 Kornhill Road Quarry Bay, Hong Kong Phone (+852) 2 568 6283 Fax (+852) 2 885 8610 Please visit www.xrite.com for a local office near you. P/N DTP34-500 Rev. D