Clearguard ACM 100 axle counting system. Smart track vacancy detection for cost-effective rail services. siemens.com / mobility

Similar documents
Smart track vacancy detection for cost-effective rail services siemens.com/mobility

The Az S 350 U microcomputer axle counting system. Vacancy and occupancy detection of track sections.

Trackguard Simis IS. The Standard for Individual Operating Conditions. siemens.ch/mobility

FAdC FRAUSCHER Advanced Counter

How digitalization is shaping the future of mobility

Answers for energy. SIPROTEC 5 the new benchmark for protection, automation, and monitoring of transmission grids

Press Presse Press Presse

ECONOMICAL INSTALLATION CONCEPTS. Murrelektronik is your partner. ÔÔMetal cutting machine tools. ÔÔAssembly and handling equipment

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

MSI Safety Devices PRODUCT INFORMATION

Combinable for All Applications

RAIL SIGNALLING SOLUTIONS

Flexible insurance against downtimes. SIMATIC S7-400H: high availability and safety in one system based on PROFIBUS and PROFINET

siemens.com/mobility Switchguard SURELOCK Points drive system

SICAM AK 3. Flexible automation for all applications. Automation, telecontrol and communication for large data volume.

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Automation Unit TM 1703 ACP. SICAM 1703 flexible for all applications. Answers for energy.

Perfect protection smallest space

What fulfills the highest demands on the current and voltage quality?

Control IT S800 I/O System

MLD 500, MLD 300 Multiple Light Beam Safety Devices and transceiver with integrated muting

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

Transportation Solutions LÜTZE Rail Technology. Product overview Control Technology

Compact Telecontrol System TM 1703 mic. SICAM 1703 flexible for all applications. Answers for energy.

siemens.com/mobility Sipark PMA barrier-paystation system Quick and hassle-free operation for customers and operators

Thales on the Transportation market

A full range of monitoring solutions for surge arresters

LION SAFE Remote I/O System. LÜTZE TRANSPORTATION GMBH Dimitrios Koutrouvis V00

Mobile Communications for the Transport Sector

Compact Power for Decentralized Applications MOVIPRO SDC/ADC

Unmanaged Industrial Ethernet Switches

SCALANCE X-200 Managed Industrial Ethernet Switches siemens.com/x-200

SafeLogic compact Safety in a small format

SIMATIC ET 200SP and ET 200MP

Solutions in conveyor technology

Go beyond... IEC Leverage the full potential with leading-edge expertise. Answers for infrastructure and cities.

SICAM ertu Your Entry to Telecontrol Technology with Extended Functionality

Company main topic [ Product ] TracFeed DCP2. English. Multifunctional Device for Control and Protection in DC switchgear.

Automation meets IT. SCALANCE X-500 central interface between Industrial Ethernet and IT networks SIMATIC NET. siemens.

AlTrac ETCS solutions Customer focused innovation for business performance

Innovation for system integration

Solution Railway. tgood.com

The demands placed on commercial vehicles have evolved dramatically over the years. With new

DESIGN PRACTICE NOTE AXLE COUNTER RESET

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

A full range of monitoring solutions for surge arresters Answers for energy.

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK

SWT 3000 Teleprotection siemens.com

Impulse switching module

MTL8000-2/x Series Modular I/O

PROFINET The industrial Ethernet standard. This is my way

Wireless connected with SCALANCE W! Industrial Wireless LAN. Industrial Wireless Communication. Edition 09/2017. Brochure. siemens.

SIMATIC S plus TIA Portal

MVK Metall and Impact67 Compact Modules IP67

MSI 100, MSI 200 Programmable Safety Controllers

HIMA specialist essay Integrated safety controllers with safeethernet.

Drive-by-Data & Integrated Modular Platform

Thales rue Grange Dame Rose Vélizy-Villacoublay - +33(0)

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Redundancy. For maximum plant availability.

Mass Transit Systems for Rail On Board Applications

M-series Foundation Fieldbus I/O

Tsutomu Morimura Central Japan Railway Company

gesis FLEX Decentralized room automation Modular Compact Pluggable Room for the future.

Pilz Network Rail Innovation & Collaboration

SIRIUS Monitoring and Controlling. Overview of safety relays. Safety Integrated. Answers for industry.

SIMEAS SAFIR The network quality system: Know your network quality avoid faults minimize downtime

MFT REPORT. 600,000 hrs The MTBF World Record DEUTA MFT Geode: the world leader in operating reliability

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Easily configurable HMI system for power automation siemens.com/sicam

Miniature circuit breakers for all applications

W Economic: Can be installed quickly and efficiently. W Compact and versatile: Top technology for limited

ADIF INTERNATIONAL CUSTOMIZED RAIL SOLUTIONS

DIS-2 series Decentralised servo drive

Compact Control Builder AC 800M and S800 I/O ABB

Advantageous PLUS Technology for SITRAFFIC C800. Your Success is Our Goal. Industrial Solutions and Services

Trusted Strategic Partners in Process Automation. Alliance Member

Customized Switches for the Harshest Conditions

The innovative interface for the last few meters to the process

TAPCON NEXT-GENERATION VOLTAGE REGULATORS. transformer control

DIS-2 series Decentralised servo drive

VLT Integrated Servo Drive ISD 510 flexible and open system

DC Substations / Supply Program

Benefits, offering and references

Maximizing security. Creating transparency. Increasing efficiency. VisuNet RM Shell 5 for Thin-Client Operator Stations

IS1 remote I/O. ready for the future

SICAM RTUs Ready for the Future

SIPROTEC 5 Protection, automation, and monitoring

Solutions for machine builders. Build a better machine with Eaton solutions integrated

Product Families and Positioning. Protection Portfolio

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.

FC726 Fire control panel

FC724 Fire control panel

AS-Interface Safety at Work

Programmable modular safety controller PROTECT PSC1

ENHANCING INTELLIGENCE IN THE INTERNET OF THINGS The Business of Embedded Virtualization Alexander Damisch, Director, Industrial Vertical, Wind River

Applications & Tools. Failsafe and standard cross communication of the MSS 3RK3 via AS-Interface. SIRIUS Safety. FAQ February 2012

POWER SUBSTATIONS. High available switches for power substations

The Efficient Way. SVC PLUS Innovation meets experience. Answers for energy.

FC722 Fire control panel

Transcription:

Clearguard ACM 100 axle counting system Smart track vacancy detection for cost-effective rail services siemens.com / mobility

The launch of smart track vacancy detection The Clearguard ACM 100 axle counting system Smart installation: easy to mount Safeguarding mobility is one of the big challenges in our society. To ensure our mobility in future, we need networked transportation and information systems. This is why Siemens with its Complete mobility approach is offering integrated transportation and logistics solutions for safe, costeffective and environment-friendly passenger and freight services. Key elements of Complete mobility are efficient solutions for rail-based transportation systems From the market leader in rail signaling technology now comes the new generation of smart track vacancy detection systems. Targetoriented development, task-directed design and the use of state-of-the-art technology solutions create a new combination of trendsetting capabilities and hitherto unknown features that give the system outstanding cost-effectiveness. Track vacancy detection creates the basis for rail automation. A track vacancy detection system supplies the information about whether a track in a particular section is clear or occupied, thereby permitting safe, trouble-free and efficient operations management. For use in local transportation links in urban and suburban areas as well as for mainline, regional and industrial railways, Siemens has developed a new generation of smart track vacancy detection systems that offer benefits hitherto unimplemented in signaling, coupled with high costeffectiveness, by using intelligent, intercommunicating modules and a system configuration based on an Ethernet network. The Clearguard ACM 100 axle counting system is made up of maintenance-free ACM 100 modules, which are programmed via an ID plug and combined with the Ethernet bus and WSD wheel detectors into a fail-safe axle counting system. Safe, reliable, approved Clearguard ACM 100 was developed in accordance with the safety requirements of the European CENELEC standards EN 50126, EN 50128 and EN 50129 and conforms to the highest safety integrity level, SIL 4. The detection equipment used meets the latest compatibility requirements for cross-border traffic in Europe.

Smart platform for effective configuration and speedy installation Clearguard ACM 100 axle counting system Smart configuration: the system concept The modular architecture of the Clearguard ACM 100 track vacancy detection system enables it to be tailored to individual customer requirements. The required number of Clearguard ACM 100 modules is functionally matched to the topology. The Clearguard ACM 100 axle counting system offers smart track vacancy detection for the cost-effective implementation of individual operating concepts. The outdoor equipment consists of the WSD wheel detectors; they detect the passing wheels. The pulses are transmitted via a 4-core trackside cable to the indoor equipment of the Clearguard ACM 100 axle counting system installed in the interlocking building. The Clearguard ACM 100 modules perform the following process steps: Evaluation of the signal pulses transmitted from the wheel detection components Comparison of the number of axles entering a track vacancy detection section with the number of axles leaving it Monitoring the track vacancy detection sections and transmission of clear or occupied indications to the interlocking Optional transmission of sensor and / or block information via ACM ACM Ethernet communication. Modular hardware architecture For the configuration of an axle counting system, one or more Clearguard ACM 100 modules are connected to an Ethernet network via switches. The switches and power supply modules are standard automation modules which are available worldwide. The Clearguard ACM 100 module has a robust metal housing and can be quickly installed by simply locking it into position on a mounting rail. This type of installation reduces commissioning times and cuts installation costs. The consistent use of only one module type reduces hardware costs as well as the outlay for stocking spare parts. HTML-based software for plug-and-play The software of the Clearguard ACM 100 axle counting system is based on a 2-outof-2 computer configuration according to the Simis principle, which ensures fail-safety in interlockings and railway signaling applications. The data configuration for the Clearguard ACM 100 modules is done via a graphical user interface on an integral website in the module. The data is stored on a programmable ID plug that can, if necessary, be removed and plugged onto another Clearguard ACM 100 module.

Smart system: the components 1 ACM 100 2 Power transformer 3 Ethernet switch The graphical user interface, with its user-friendly display, provides optimal support for all operational, service and maintenance tasks. The following automatically and cyclically updated information as well as failure indications can be displayed, for example: Clear or occupied for the two track vacancy detection sections of the Clearguard ACM 100 system Number of counted axles Status of the WSD wheel detectors Status information and stored log files can be called up in the form of graphics and data lists. LED indicators on the Clearguard ACM 100 module permit simple diagnostics even on site. Easy module replacement A Clearguard ACM 100 module can be replaced in the energized state; it is no longer necessary to switch off the system components and interrupt operation. Smart basis for extension, modification and migration The concept of the Clearguard ACM 100 permits easy extension and modification, thereby ensuring investment security for years to come. Hardware replacement and extension or configuration updates can be carried out within a very short period of time. It is not necessary to interrupt rail operation. Potential-free relay interface For the connection to other interlockings or subsystems, the Clearguard ACM 100 has a potential-free relay interface that allows flexible adaptation to a wide range of operating conditions. Existing installations can thus be cost-effectively upgraded or extended and cost-effectively optimized. 4 5 Router WSD (track) 6 Terminal box (track)

Smart track vacancy detection for smart operators Low investment costs coupled with high efficiency Smart communication: diagnostics via Internet Applications Main and branch lines, station areas, point areas Single- and multiple-track lines Lines with and without blocks All types of traction All common car types Track sections of any length Train speeds up to 450 km/h (280 mph) System benefits Connection to electronic and relay interlockings HTML communication for effective configuration, logging and diagnostics Modular, compact hardware Innovative diagnostic concept Low-cost WSD wheel detector Low initial costs With Clearguard ACM 100, track vacancy detection applications for individual operating concepts can be implemented quickly and economically. Whether in a centralized or decentralized configuration, the features modular system architecture, only one standard module, standard Ethernet bus, optimized system configuration, low-cost wheel detector and minimized building space requirements make for an extremely cost-effective system. High performance and availability The Clearguard ACM 100 module is intelligent and communicative and can monitor two track sections. Each module has its own IP address and an integral website for communication and operator control and is thus addressable via Ethernet. This creates high system transparency and offers advantages for achieving the maximum possible availability of the track vacancy detection system. Programming via ID plug The Clearguard ACM 100 modules are equipped with a programmable plug element (ID plug) with its own software. The configured data can be transferred to a replacement ACM simply by removing and then reinserting the ID plug. Thus, faults can be quickly rectified and downtimes minimized. Easy extension / migration The Clearguard ACM 100 concept permits easy extension and modification, thereby ensuring investment security for years to come. Hardware replacement and extension or configuration updates can be carried out without having to interrupt rail operations. Cost-effective maintenance The highly dependable and service-free Clearguard ACM 100 hardware ensures a low maintenance outlay and low lifecycle costs. Because all the track vacancy detection applications are implemented using a single module type, system configuration is easy and fewer spare parts have to be stocked. Intelligent diagnostics The ability to communicate with the integral website (IP address) allows remote diagnostics via a network (Internet or Intranet) from any location at any time. The integral website enables the current status information to be requested.

Siemens AG Industry Sector Mobility Division P.O. Box 3327 38023 Braunschweig Germany Phone: (+49) (5 31) 226-2888 Fax: (+49) (5 31) 226-4888 Siemens AG 2010 Printed in Germany PPG189 312240 PA08102.0 Dispo 01000 c4bs 7633 Order No.: A19100-V100-B000-V1-7600 The information in this document contains general descriptions of the technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. www.siemens.com