Multi-Point Gas Detection and Control System

Similar documents
Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System

Multi-Point Digital Gas Detection and Control System

Gas Controller System DGC-06

Sensor for car parks and tunnels

CDD Carbon Dioxide Transmitter

Trident and Trident X2 Digital Process and Temperature Panel Meter

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

CDD4 Duct Carbon Dioxide Transmitter

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

HIGH-VOLTAGE DC METER

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

PGR-3200 MANUAL INSULATION MONITOR

Temperature Controller E5C4

High Voltage DC Meter

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

EMS467 Monitoring System. Installation and Operations Manual Section 40

ISOMETER isoev425 with coupling device AGH420

TPE 1464 Series Pressure Transducer

Operating instructions. Standstill monitor A / / 2011

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Communication Module BAC-06 for DGC-06 System

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

Communication Module BAC-06 for DGC6 System

Installation and User Guide

CDD4 Series Room CO2 Transmitter Installation Instructions

Power Meter PowerMonitor 500

MIC-2 MKII, Multi-instrument DATA SHEET

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

dual-line 6-dIGIt process MeteR

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Dräger Polytron 8200 Stationary gas detector (CatEx)

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

LAUREL ELECTRONICS, INC.

Field selectable application type and room module series, via dip-switches on controller

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

PTU300 Combined Pressure, Humidity and Temperature Transmitter

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Andover ContinuumTM Infinet II

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Simplified information where and how you want it.

ISOMETER isoev425/isoev425hc with coupling device AGH420

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

TAC I/NETTM 1284, 1280, Security Control Unit

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Signet Pressure Transmitter

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

FX Input/Output (I/O) Modules XM07 and XM14

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Thermocouple Input Module Product Specifications and Installation Data

MIC-2 Multi-instrument DATA SHEET

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

Process & Temperature Digital Panel Meter

BA/BS4S Temperature Sensor Installation & Operating Instructions

Process displays For current and voltage

MOD-RI Room Interface Modules with Modbus

Zone Pressure Touch Sensor - Standard Range

Measure & Control Temperature & CO2 levels with analog & digital I/O

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

DTM Distributed Transmitter Monitor

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

General information. Display. Supply voltage. Input current

Amplifiers, Counters, Timers & Controls

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

DMT345 and DMT346 Dewpoint Transmitters

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

Zone Pressure Touch (ZPT) Sensor - Standard Range

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

MODEL: R2K-1 SEN TRONIC AG. R2K Series

PD765 TRIDENT. Trident Series Process & Temperature Meters.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

RTD-W Installation Instructions

Carbon Monoxide Sensor - ModBus

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

BACnet/IP Web Interface

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Energy Management Modular Energy meters Type EM2-96

PanelView Plus/VersaView CE Terminals and Display Modules

AirTest Model CN9000 Series Sensor Controller

PD765 TRIDENT. Trident Series Process & Temperature Meters.

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

Safety Temperature Limiter TT-STL 50

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

MMT330 Series Moisture and Temperature Transmitters for Oil

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

InteliLite MRS17 Click Here to Learn More

Transcription:

Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and alarm. PolyGard MGC2-20 APPLICATION To control and alarm upon the presence of any toxic, combustible and refrigerant gases. Any combination of the AT-/3300 series or other 4-20 ma transmitters can be connected to the control unit. The controller can interface via binary outputs, a signal, and/or an optional BACnet or Modbus port with any compatible electronic analog control, DDC/PLC control or automation system. FEATURES Continuous monitoring Twenty (20) analog inputs, Four (4) digital inputs Twenty (20) relay outputs: - Five-stage control - Fail-safe assignable Ten (0) analog outputs, - Selectable for low, high or averaging One () supply output Built-in horn Accepts combination of toxic or combustible gases, refrigerants, temperature or humidity sensor inputs Liquid Crystal Display (LCD) Optional BACnet or Modbus upwards communication to BAS LED status indicators Keypad user interface Simple menu-driven programming RFI/EMI protected Modular technology Overload & short-circuit protected Resettable breaker NEMA 4X enclosure Easy maintenance City of Los Angeles Approved NRTL Tested & Certified Conforms to STD UL 207 UL 2075 certified PolyGard Carbon Monoxide & bustible Gas Transmitters are recommended for maximum system performance and reliability Upwards munication Options BACnet, Modbus SPECIFICATIONS Electric Power supply Power consumption RF/EMI protected Type of Control General Analog inputs Analog reading Stage level / setpoint - hysteresis/ switching differential 20 VAC (90...230 VAC), 50/60 Hz resettable breaker, 24 VAC on request 60 VA, max. 4.0 W @ 3 ft. ( m) radiated Five-stage (S to S5) control, assignable up to twenty (20) binary/relay output, i.e. Low-med-high-fault/fail-horn*, or low-low2-med-med2-high, or any other combinations (* = horn/audible alarm built-in and factory pre-configured to relay output R20 ) Twenty (20) Current and mean (average) value Field adjustable over full range, five (5) per analog input, assignable to current or mean (average) value Selectable for each sensor point Digital inputs Four (4), each can be individually assigned to any relay (R...R20). - application Remote audio/visual alarm reset or override function Relay outputs (R-R20) w/ status LEDs Twenty (20) SPDT, 8 A 24 VAC/VDC-250 VAC contact resistance 00 mω, max. - each stage level (S-S5) Assignable to any relay - sensor fail-safe Assignable to any stage level Time delay switching Selectable for make and brake of each sensor point (SP to SP20) 0-9,999 seconds VDC output supply, 0.5 A fused Analog output Ten (0) independent signal, 500 Ω max. load, selectable as low, high or averaging of sensor inputs Audible alarm 85 db (0 ft), enabled or disabled, selectable; assignable to stage level S, S2, S3, S4 or S5 Alarm acknowledgment Menu-driven and system reset function for latched relays

Specifications subject to change without notice. USA 50729 Page 2 of 9 SPECIFICATION User Interface Keypad type Refer to section User Interface & Controller Touch buttons Six (6) Status LED s Yellow: Fault (fail) Red: Alarm Digital display Liquid Crystal Display (LCD), two lines, 6 characters per line, digit resolution, backlit - unit display Menu selectable, per sensor; ppm, %LEL, Vol%, F, %RH, %, ppk, C BACnet Interface, optional* Read status information via BACnet coupler and BACnet- Profile, BACnet-Services and BACnet BIBBs Input scaling 0-250 ppm CO Coupler option B 0-00% Coupler option P munication TCP/IP 0/00 Mbits/sec Connector Ethernet RJ45 Interface BACnet-Profile Description BACnet-Services Who-is (execute) I-am (initiate) ReadProperty WriteProperty Object types Version B.2, B2.2 Modbus Interface, optional* Read status Information via Modbus interface and Modbus function 6 and 03 Module Integrated at Controller module munication 9200 baud start-bit, 8 data-bits stop-bit, no parity Interface Function 6 Description Function 03 Addresses - 000 to 098 Current value internal, sensor -98-2000 to 2048 Current value external, sensor -98-3000 to 3098 Average value internal, sensor -98-0 to 6 Relay bits, relay to 30-8 to 9 Analog outputs to 2 Environmental Permissible ambient - working temperature 23 F to 04 F (-5 C to 40 C) - storage temperature -4 F to 04 F (-20 C to 40 C) - humidity 5 to 95% RH, non-condensing - working pressure Atmospheric + 0% Physical Enclosure (panel) - material Polycarbonate, impact resistance EN 5002/IK08, flammability rating UL 94-5V - conformity UL Type, UL 508 / UL 50 standards - color Light gray, smoked gray for cover - protection NEMA 4X (IP65) - installation Wall (surface) mounted Dimensions (H x W x D) - base 22.8 x 2.0 x 5.7 in. (580 x 306 x 45 mm) Cable entry 0 holes for /2 in. conduit, covered Wire connection Terminal blocks, Push-on connect and screw type for lead wire Wire size - input Min. 22 AWG (0.34 mm 2 ) Max. 6 AWG (.50 mm 2 ) - output Min. 24 AWG (0.25 mm 2 ) Max. 4 AWG (2.50 mm 2 ) Weight 4.5 lbs (6.6 kg) Approvals / Listings - unit rating NRTL Perf. Tested & Certified Conforms to STD ANSI/UL 207 City of Los Angeles CE VDI 2053, C-No. 4879 EMC-pliance 89/336/EWG - enclosure (panel) UL Listed, E75645 Warranty Two years material and workmanship (*) BACnet Interface: NRTL Certification to UL STD 600- Pending

Specifications subject to change without notice. USA 50729 Page 3 of 9 ORDERING INFORMATION MGC2-20 - 2000 US 00 0 B0 P0 M0 Options No options Key Lock w/2 keys BACnet Upwards munication Coupler C5-BAC-98 for AT Transmitters (0-250 ppm CO) BACnet Upwards munication Coupler C5-BAC-98- for AT Transmitters (0-00%) Modbus Upwards munication Port (integrated) Standard control system, ordering part number: MGC2-20 - 2000 US, configuration includes: Digital, programmable controller with menu-driven key-pad user interface, LCD & LEDs, 20 VAC (90...250 VAC) 50/60 Hz, NEMA 4X enclosure : (20) (4) Digital Outputs: (20) Relays, SPDT, 8 A (0) (), 0.5 A

Specifications subject to change without notice. USA 50729 Page 4 of 9 USER INTERFACE & CONTROLLER Keypad User Interface Alarm Power INTEC 3.06.3 :45am Exits programming; returns to the previous menu level. Main Page & Main Menu INTEC 3.06.3 :45am System Errors Stage Status Relay Status Readings Relay Setup SP Setup Data Logger System Setup Alarm 2 - n Enters sub menus; saves parameter settings. Scrolls up & down within a menu; changes a value. Moves the cursor position. Fault System Operation All programming is made via the keypad user interface in combination with the display screen. Security is provided via two password levels. The lower level password (234) allows to override or to reset system status functions. The upper level password (900) allows all programming and override functions. Main Page Display After powered on, displays INTEC and Date/Time and changes to sensor reading display unless a system error occurs; then the error is displayed. Main Menu Displays headings of System Errors, Stage Status Relay Status, Readings, Relay Setup, SP ( Point) Setup, Data Logger and System Setup. Sub Menu System Errors Displays errors, reset corrected errors, and historical error summary. Sub Menu Stage Status Displays status of each SP sensor point, stage level/setpoint exceeded. Sub Menu Relay Status Displays status and manual control of each output relay. Sub Menu Readings The current or average values are displayed for each SP sensor point with sensing type and engineering unit (ppm, %LEL, Vol%, F, %RH, %, ppk, C). Sub Menu Relay Setup Enter and/or change parameters of each relay. - Assign de-energized or energized normal operation - Select steady or flashing function - Select latching or non-latching mode - Select horn re-annunciation interval - Select digital input usage, and assign to any output relay - Set ON/OFF time delay Sub Menu SP Setup Enter and/or change parameters of each sensor point. - Activate/deactivate sensor point - Lock/unlock sensor point - Alarm on rising or falling value - Select sensor point type (gas, temperature, humidity) - Select full scale measuring range - Select sensor signal - Select stage/setpoint to 5 - Select hysteresis - Set delay ON/OFF time - Select current or average mode - Assign sensor point fault to stage level activation - Assign setpoint to 5 to any output relay - Assign to analog output Sub Menu Data Logger - Set data logger ON/OFF - Set sensor data logging ON/OFF - Set sensor data logging interval - Set alarm ( stage status ) logging ON/OFF - Set system error logging ON/OFF Sub Menu System Setup Enter and/or change system parameters. - Select service mode ON/OFF - Set next maintenance date - Select service phone number - Select averaging function, time and overlay, of any SP - Set date, time and time format - Change customer password - Select analog output function - Set failure relay - Select power ON time (alarm suppression) - Select appropriate hardware configuration - Assign relay multiplication

Specifications subject to change without notice. USA 50729 Page 5 of 9 FIELD WIRING CONFIGURATION Green/Ye G Gray X Gray H Blue N Green/Ye G (see ill. ) (see ill. 4) 2 2 3 4 5 6 7 8 9 0 2 3 4 5 (see ill. 2) X Fault 20 VAC Input Power Binary - Relay Outputs R06 R07 R08 R09 R0 2 2 3 4 5 6 7 8 9 0 2 3 4 5 Alarm INTEC Controls 05.07.0 0: 28am X0 2 3 4 5 6 7 8 902 2 3 4 5 6 7 8 902 Binary - Relay Outputs R0 R02 R03 R04 R05 Digital Analog Outputs (see ill. 5) (see ill. 6) (see ill. 2) (see ill. 2) DIN Rail Optional: Modbus Interface (see ill. 8) Binary - Relay Outputs RR2 R3 R4 R5 2 2 3 4 5 6 7 8 9 0 2 3 4 5 2 3 4 5 6 7 8 C5 m. Coupler Optional: BACnet X 2 3 4 (see ill. 7) Recommended Twisted, shielded wire for analog inputs (Shield to be terminated and connected only at the sensor/transmitter location or controller) Grounded housing Do not ground at both ends! Caution: The non-metallic enclosure does not provide grounding between conduit connections. Use grounding bushings and jumper wires. The enclosure is to be mounted using the mounting holes located in the base external to the equipment cavity, or the equivalent. The conduit hubs must be connected to the conduit before connected to the enclosure. When connecting conduit to the enclosure use only UL listed or UL recognized conduit hubs that have the same environmental type rating as the MGC2 enclosure. X X EP-02- EP-02-2 DIN Rail X0 X0 2 3 4 5 6 7 8 902 2 3 4 5 6 7 8 902 2345678902 2345678902 Analog Outputs Analog Outputs (see ill. 4) (see ill. 2) (see ill. 6) (see ill. 4) (see ill. 6) ill. (see ill. 4) X Binary - Relay Outputs R6 R7 R8 R9 R20 2 2 3 4 5 6 7 8 9 0 2 3 4 5 EP-02-3 X0 Terminal block X 2 Circuit breaker F 2345678902 2345678902 (see ill. 3) Analog Outputs Output Power Unit Top (see ill. 6) (see ill. 4) L N X G V- V+ 2 2 3 4 5 6 7 8 9 0 2 3 4 5 EP-02-4 X0 Bottom Horn 2345678902 2345678902 (see ill. 6) Analog Outputs DIN Rail 20 VAC Input Power Supply 20 VAC (90...230 VAC), 50/60 Hz AC hot AC neutral Earth ground G H N Green/Yellow Blue Min wire size 6 AWG (.5 mm 2 ) Gray Terminal block Resettable breaker, max 0 A, rated current approx. 2 A

Specifications subject to change without notice. USA 50729 Page 6 of 9 FIELD WIRING CONFIGURATION (cont...) Binary - Relay Outputs R0 to R5 (Located at Controller module, EP-02- & EP-02-2 modules) Stage-level control & alarming #5 #4 #3 #2 # 2 3 4 5 6 7 8 9 0 2 3 4 5 R0 R02 R03 R04 R05 Normal condition (factory default) D D2 D3 D4 D5 = Relay status LEDs D to D5 located below terminal connection of sensor inputs (X0) Stage-level control & alarming #0 #9 #8 #7 #6 EP-02-2 3 4 5 6 7 8 9 0 2 3 4 5 R06 R07 R08 R09 R0 Normal condition (factory default) D D2 D3 D4 D5 = Relay status LEDs D to D5 located below terminal connection of sensor inputs (X0) Stage-level control & alarming #5 #4 #3 #2 # EP-02-2 2 3 4 5 6 7 8 9 0 2 3 4 5 R R2 R3 R4 R5 Normal condition (factory default) D D2 D3 D4 D5 = Relay status LEDs D to D5 located below terminal connection of sensor inputs (X0) ill. 2

Specifications subject to change without notice. USA 50729 Page 7 of 9 FIELD WIRING CONFIGURATION (cont...) Binary - Relay Outputs R6 to R20 Built-in horn alarming*** factory wired, Fault (fail) alarming Stage-level control & alarming ( ) (+) *** #8 #7 #6 (Located at EP-02-3 module) H EP-02-3 *** Factory pre-configured horn and fault (fail-safe), can be reassigned/converted for remote control, stage-level #9 and/or #20 2 3 4 5 6 7 8 9 0 2 3 4 5 R6 R7 R8 R9 R20 Normal condition (factory default) D D2 D3 D4 D5 = Relay status LEDs D to D5 located below terminal connection of sensor inputs (X0) ill. 2 (cont...) Output Supply 2 (+) (-) max 0.5 A for remote alarm display units Terminal block X ill. 3

Specifications subject to change without notice. USA 50729 Page 8 of 9 FIELD WIRING CONFIGURATION (cont...) SP0 to SP20 (Located at Controller module, EP-02-, EP-02-2, EP-02-3 & EP-02-4 modules) 2 3 4 5 6 7 8 9 0 X0 SP0 SP0/02- ( ) SP02 SP03 SP03/04- ( ) SP04 2-wire sensor / transmitter 3-wire sensor / transmitter ( ) EP-02-2 3 4 5 6 7 8 9 0 X0 EP-02-2 2 3 4 5 6 7 8 9 0 X0 SP05 SP05/06- ( ) SP06 SP07 SP07/08- ( ) SP08 SP09 SP09/0- ( ) SP0 SP SP/2- ( ) SP2 EP-02-3 2 3 4 5 6 7 8 9 0 X0 EP-02-4 2 3 4 5 6 7 8 9 0 X0 SP3 SP3/4- ( ) SP4 SP5 SP5/6- ( ) SP6 SP7 SP7/8- ( ) SP8 SP9 SP9/20- ( ) SP20 ill. 4 Digital DI0 to DI04 (Located at Controller module) 2 3 4 5 6 7 8 9 0 2 ill. 5

5 6 7 8 MGC2-20 Specifications subject to change without notice. USA 50729 Page 9 of 9 FIELD WIRING CONFIGURATION (cont...) Analog Outputs AO0 to AO0 (Located at Controller module, EP-02-, EP-02-2, EP-02-3, EP-02-4 modules) 2 3 4 5 6 7 8 9 0 2 Keypad User Interface 2 3 4 5 6 7 8 9 0 2 EP-02-2 (AO02) (AO0) (AO06) (AO05) 2 3 4 5 6 7 8 9 0 2 EP-02-2 3 4 5 6 7 8 9 0 2 EP-02-3 (AO04) (AO03) (AO08) (AO07) 2 3 4 5 6 7 8 9 0 2 EP-02-4 (AO0) (AO09) signal to remote control or BAS, selectable low, high or averaging of (8) analog (sensor) inputs, 500 Ω max. load The current signal is sourced by the MGC system ill. 6 C5 BACnet munication Coupler, optional 4 3 2 ill. 7 Modbus Interface, optional (Located at Controller module) RJ45 Upwards BACnet communication to BAS ill. 8 2 3 4 5 6 7 8 9 0 2 MOD_A MOD_B 0 VDC