NetworX Series NX-216 Zone Expander Installation and Startup

Similar documents
INSTALLATION MANUAL. Table of Contents. General Description Position Dip Switch Settings Enrolling the NX216-E Expander...

NX1700EIB02 (Supercedes NX1700EIA02) NetworX Series. NX-1700E Proximity Card Reader Installation and Startup

NX-2192E PINPOINT SYSTEM

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup

Installation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...

NetworX Series NX-1710E Single Door Control. Installation and Startup Manual

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series NX-8V2 Control Panel Installation and Startup

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

NX-148 LCD KEYPAD INSTALLATION MANUAL

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

Series. NX-8-EUR Control Panel. Installation manual

Installation Instructions

Digiplex EVO High Security and Access System What s New EVO192 V2.7

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

NetworX Series. NX-148E LCD Keypad NX-148E-CF LCD Keypad Installation and Setup

High Frequency Power Supply Board IS200HFPRG_A

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

DSC programming for the Alexor and Impassa

EVOHD. Programming Guide. Version

DAS ALPHA NUMERIC LCD CODEPAD INSTALLATION MANUAL

2-Way Wireless I/O Expander Installation Guide

LCI AUXILIARY I/O TERMINAL BOARD DS200DDTBG_A

3 6HFXULW\6\VWHP 3URJUDPPLQJ)RUP K4332 9/99 BYPASS NOT READY ARMED READY 4 MAX 5 TEST 6 BYPASS 7INSTANT 8 CODE 9CHIME READY ARMED

Ademco/Protection One 250P1-1 Programming Form

NX-1248E LCD KEYPAD Installation and Setup

MG/SP Series (V4.9/V5.1) What s New

SOFTWARE VERSION 3.10

VISTA-20BAY PROGRAMMING GUIDE SECURITY SYSTEM SINCE 1946

Ademco Vista-20SE/First Alert FA-162C Program Sheet

For use with QED controls panels ONLY

INSTALLATION INSTRUCTIONS

Property of Monitronics Inc

IDS1200 INSTALLER MANUAL. Summary of Operation 2 IDS1200 INSTALLER MANUAL - NO B ISSUED AUGUST 2002 VER 1.18

SECURITY MODULE CG3 User Manual

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

VISTA-50P VISTA-50PUL

INT-KSG Keypad Quick user s guide

For use with QED and hardwired control panels ONLY!

CA-A480-A Elevator Controller. Reference & Installation Manual

Property of Monitronics Inc

Installation Instructions. Product Summary. Installation Guidelines. Tools and Equipment Needed. Table 1. Touchpad Power Usage

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

First Alert FA160C/162C Installer Notes M. Leuck

INT-KSG Keypad Quick user s guide

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

VISTA-128BP/VISTA-250BP Programming Form

DAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End

User Guide. Connect2Go User Guide rev1.0 PO Box 3382 Station Main, Meaford Ontario N4L 1A5 T: (+1)

NX-1192E LCD KEYPAD INSTALLATION MANUAL. Table of Contents ENTERING THE PROGRAM MODE...2 SELECTING THE MODULE TO PROGRAM...2

LCD62. Keypad. User Manual

4140XMPT2 PROGRAMMING FORM

Wireless keypad PRF-LCD-WRL

CONTACTOR DRIVER BOARD. DS200CDBAG1A and DS200CDBAG1B

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

PROGRAMMING HELP GUIDE

IMPORTANT! GE Caddx panels cannot support PIN codes then end in zero over RS-232. See Common Mistakes for more information.

High Security and Access System EVO48 V2.1 EVO192 V2.1

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13

NetworX Series. NX-590E Internet Interface Installation and Startup

INSTALLATION SHEET 791 and 793 Easy Entry Keypads

Property of Monitronics Inc

SIGMA "APOLLO" APOLLO User Manual Page 1

CUSTOMER INFORMATION

ADEMCO LYNXR-ENSIA Security System

212iL Rev. 1.1

Property of Monitronics Inc

Keypad LCD (software version 3.10) CA-10 plus

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

ATP1000 Touchpad/Display Installation Instructions

Installation Manual IMPORTANT NOTE

INSTRUCTIONS. D14A4F expanded I/O. for AV-300i Drives. 8 Digital Inputs 6 Digital Outputs 2 Analog Inputs 2 Analog Outputs 1 Frequency Input

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

Modules Programming Guide. paradox.com

791/793 Easy Entry Keypads

7000 Series Thinline LCD Keypads Models 7060/7063/7070/7073

_A_en_LED63VG VOICE GUIDE KEYPAD LED63VG

Important Notice. Customer Information. 2 WisDom User Manual

Commercial Burglary Partitioned Security System With Scheduling. Programming Guide. K5894PRV4 6/04 Rev A

KTD-125/ KTD-125P/125P-24 KTD-127/127W PTZ Receivers

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

pro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM

DAS LCD ALPHA NUMERIC CODEPAD

2 IDS LCD Keypad User Manual C Issued March 2009

NX-595E User Manual P/N REV C ISS 02JUL14. Downloaded from manuals search engine

PROGRAMMING AND INSTALLATION MANUAL

FW2 MERLIN PRO Manual ==============================

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

V-9908 MESSAGE/PAGE PANEL

MR52 READER INTERFACE

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Keypad LCD-L (software version 3.10) CA-10 plus

INT-TSG Installer Manual

Transcription:

NetworX Series NX-216 Zone Expander Installation and Startup

2

2002 GE Interlogix All rights reserved. Printed in the United States of America. These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to be met during installation, operation, and maintenance. If further information is desired or if particular problems arise that are not covered sufficiently for the purchaser s purpose, the matter should be referred to GE Interlogix, Gladewater, Texas, USA. This document contains proprietary information of GE Interlogix, USA and is furnished to its customer solely to assist that customer in the installation, testing, operations, and/or maintenance of the equipment described. This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third party without the written approval of GE Interlogix. Please refer to the current GE Interlogix product catalog for detailed warranty information. Main 800-727-2339 Technical Support 800-727-2339 Outside the US 903-845-6941 Tech Support Fax 903-845-8409 Main Fax 903-845-6811 Sales & Literature 800-547-2556 Web: www.caddx.com www.ge-interlogix.com NetworX is a trademark of the GE Interlogix companies. NX-216 ZONE EXPANDER 3

Symbol Legend Warning Indicates a procedure, practice, condition, or statement that, if not strictly observed, could result in personal injury. * This symbol indicates electrical warnings and cautions. Caution Indicates a procedure, practice, condition, or statement that, if not strictly observed, could result in damage to or destruction of equipment or property. ** This symbol indicates general warnings and cautions. Note Indicates an essential or important procedure, instruction, condition, or statement. Tip Indicates a user tip. Provides helpful information that is not normally defined in regular use, but from an experienced user. 4 NX-216 ZONE EXPANDER

TABLE OF CONTENTS 1. GENERAL DESCRIPTION...6 2. 4-POSITION DIP SWITCH SETTINGS...6 3. ENROLLING THE EXPANDER...6 4. TERMINAL DESCRIPTION...7 5. WIRING DIAGRAM...7 6. DEFAULT ZONE CONFIGURATIONS...8 7. PROGRAMMING ZONE CONFIGURATION & PARTITION...9 8. SPECIFICATIONS...12 NX-216 ZONE EXPANDER 5

1. GENERAL DESCRIPTION The NX-216 is a microprocessor-controlled 16-zone expander for the NX-8 control panel. Up to five NX-216 expanders can be added to the NetworX control panel with a maximum zone count of 48 zones. Each expander has an optional tamper switch and power isolator making it ideal for use in a remote location. 2. 4-POSITION DIP SWITCH SETTINGS The first thing that must be decided is the starting zone of this particular zone expander. The starting zone must be on a boundary of eight (8) zones. The sixteen (16) zones for this module will move out from this starting position. There are stick-on zone labels to indicate the zone numbers that you select. To set the starting zone, set the dip switch according to the table below: NOTE: THE POSITION OF ALL SWITCHES IS ONLY UPDATED WHEN THE NX-216 IS POWERED UP. BEFORE YOU CHANGE THE POSITION OF THESE SWITCHES YOU MUST POWER DOWN THE EXPANDER. Starting Expander # DipSwitch1 DipSwitch2 DipSwitch3 Zone Number Reported 9 22 OFF OFF OFF 9 23 ON OFF OFF 17 16 OFF ON OFF 25 17 ON ON OFF 33 18 OFF OFF ON 41 19 ON OFF ON Dipswitch4- Dip switch 4 is used to disable the second block of eight (8) zones on this zone expander. This can be done if only an eight- (8) zone expander is required in a particular expander location. In this case, up to 5 expanders can be added to the system creating a total of 48 zones. To disable the second group of eight (8) zones on this expander, turn dip switch 4 on. 3. ENROLLING THE EXPANDER The NX-8 has the ability to automatically find and store in its memory the presence of all keypads, zone expanders, wireless receivers and any other module connected to the data terminal. This allows these modules to be supervised by the control panel. To enroll the modules enter the Program Mode of the NX-8 control panel, and when the Program Mode is exited, it will automatically enroll the devices. The enrolling process takes about 12 seconds, during which time the Service LED will illuminate. User codes will not be accepted during the enrolling process. Once a module is enrolled, if it is not detected by the control, the Service LED will illuminate. 6 NX-216 ZONE EXPANDER

4. TERMINAL DESCRIPTION TERMINAL POS COM DATA TAM DESCRIPTION Connect to the KP POS terminal of the NX-8. Current draw is 30 ma. Connect to the KP COM terminal of the NX-8. Connect to the KP DATA terminal of the NX-8. (See the wiring diagram for wire specifications.) Connect as shown below. IF NOT USED, CONNECT TO A COM TERMINAL. Can be used to power devices directly from the NX-216. Power is coming from the NX-8, therefore the current draw of these devices must be added to the total current draw of the NX- AUX 216. This output is current limited to 100 ma. Connect to one side of zone 9 loop. Connect the other side to COM terminal. Open or short Z9 causes alarm. (See the wiring diagram for examples) COM Common (-) terminal for zones 9 & 10. Connect to one side of zone 10 loop. Connect the other side to COM terminal. Open or short Z10 causes alarm. (See the wiring diagram for examples). Z11-Z24 Connect as described for Z9 & Z10. 5. WIRING DIAGRAM Any unused zones must have the EOL resistor across it (unless all eight are disabled by dip switch 4). This LED is only for proper circuit operation DS2 This LED will flash during Normal Operation Seepage2forinstructions about setting these switches ZONES Pos, Com, and Data - Connect to keypad terminals on the NX-8 or the NX-320. Tam - Connect to Com terminal through a normally closed switch. Aux - Current limited to 100mA (MUST BE ADDED TO CONTROL AUX POWER) Z9-Z24 - Connect as described in the terminal description. ZONE CONNECTIONS MAXIUMUM WIRE RUN WHEN CONNECTED TO NX-8 If using Aux terminal: 250-24 gauge 500-20 gauge 1000-18 gauge 1500-16 gauge 2500-14 gauge If NOT using Aux terminal: 250-24 gauge 750-24 gauge 1000-22 gauge 2000-20 gauge 2500-18 gauge MAXIUMUM WIRE RUN WHEN CONNECTED TO NX-320 If using Aux terminal: 250-22 gauge 500-18 gauge 1000-16 gauge 1500-14 gauge 2500-12 gauge If NOT using Aux terminal: 500-22 gauge 750-20 gauge 1000-20 gauge 2000-16 gauge 2500-16 gauge NX-216 ZONE EXPANDER 7

6. DEFAULT ZONE CONFIGURATIONS Zones can be programmed to be one of twenty different zone configurations (zone types). Configurations # 17 through 20 can be used for wireless or hardwired zones using European double EOL configuration. The default zone configurations are listed below. These zone configurations can be customized by programming locations 110-149. DATA DESCRIPTION OF DEFAULT CONFIGURATION 1 DAY ZONE - Instant when system is armed trouble zone when system is disarmed. 2 24-HOUR AUDIBLE - Creates an instant yelping siren alarm regardless of the armed state of the control panel. 3 ENTRY/EXIT DELAY 1 - A trip will start entry delay 1. The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed. FOLLOWER WITH AUTO-BYPASS DISABLED - This zone will be instant when the system is armed and 4 no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will not bypass in Stay Mode, nor automatically bypass even if enabled in Segment 1 / Location 23. INTERIOR FOLLOWER WITH AUTO- BYPASS ENABLED - This zone will be instant when the system is 5 armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone will bypass in Stay Mode, and automatically bypass if enabled in Segment 1 of Location 23. 6 INSTANT - This zone creates an instant alarm whenever it is tripped and the Armed LED is on. 7 24-HOUR SILENT - Creates an instant silent alarm regardless of the armed state of the control panel. It will not display on the keypad. 8 FIRE - This zone will illuminate the Fire LED and sound the temporal siren each time the zone is shorted. It will also rapidly flash the Fire LED indicating a trouble if the zone is open. 9 ENTRY/EXIT DELAY 2 - A trip will start entry delay 2. The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed. 10 24-HOUR SILENT SUPERVISED - Creates an instant silent alarm regardless of the armed state of the control panel. It will display on the keypad. 11 KEYSWITCH ZONE - This zone type will arm and disarm the partition or partitions of the control panel that resides in each time the zone is shorted. Keyswitch arming will report as user #99. INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED - This zone will be Instant when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. If a "Cross 12 Zone" is not being timed it will start a "Cross Zone" timer. If a "Cross Zone" is being timed it will create an Instant alarm. This zone will bypass in Stay Mode and automatically bypass when enabled in Segment 1 of Location 23. 13 INSTANT ENTRY GUARD - This zone creates an instant alarm whenever it is tripped and the Stay LED is off. It will start an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on. ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip will start entry delay 1. This zone will 14 bypass when the "Group Bypass" command is entered at the keypad. The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed. INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system is 15 armed and no entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will bypass when the "Group Bypass" command is entered at the keypad. This zone will bypass in Stay Mode and automatically bypass even if enabled in Segment 1 / Location 23. INSTANT WITH GROUP BYPASS ENABLED - This zone creates an instant alarm whenever it is tripped 16 and the Armed LED is on. This zone will bypass when the "Group Bypass" command is entered at the keypad. ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED - A trip will start entry delay 1. The lack of a trip during 17 exit delay will enable the Automatic Bypass or Instant mode if so programmed. This configuration group can be used to enable tamper on a wireless transmitter. INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED - This zone will be instant when 18 the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone will bypass in Stay Mode and automatically bypass if enabled in Segment 1 / Location 23. This configuration group can be used to enable tamper on a wireless transmitter. 19 INSTANT WITH TAMPER ENABLED - This zone creates an instant alarm whenever it is tripped and the Armed LED is on. This configuration group can be used to enable tamper on a wireless transmitter. ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED - A trip will start entry delay 2. The lack of a trip during 20 exit delay will enable the Automatic Bypass or Instant mode if so programmed. This configuration group can be used to enable tamper on a wireless transmitter. 8 NX-216 ZONE EXPANDER

7. PROGRAMMING ZONE CONFIGURATION & PARTITION The programming for all zone information is performed in the NX-8 control panel. For instructions on accessing and programming the NX-8, as well as changing the characteristics of a configuration group, refer to the NX-8 Installation Manual. The following programming information is taken from the NX-8 Installation Manual. LOCATION 27 CONFIGURATION GROUP ZONES 9-16 (8 segments, numerical data) Location 27 contains the Configuration Group (Zone type) for zones 9-16. Segment 1 is for zone 9; Segment 8 is for zone 16. Default configurations are found in the table on page 8. LOCATION 28 PARTITION SELECT ZONES 9-16 (8 segments, feature selection data) Location 28 is used to select the partition(s) that zones 9-16 reside in. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Location 28 has 8 segments. Segment 1 corresponds to zone 9 and Segment 8 corresponds to zone 16. Segments 1-8: 1 = Partition #1 2 = Partition #2 3 = Partition #3 4 = Partition #4 5 = Partition #5 6 = Partition #6 7 = Partition #7 8 = Partition #8 LOCATION 29 CONFIGURATION GROUP ZONES 17-24 (8 segments, numerical data) Location 29 contains the Configuration Group (Zone type) for zones 17-24. Segment 1 is for zone 17; Segment 8 is for zone 24. Default configurations are found in the table on page 8. LOCATION 30 PARTITION SELECT ZONES 17-24 (8 segments, feature selection data) Location 30 is used to select the partition(s) that zones 17-24 reside in. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Location 30 has 8 segments. Segment 1 corresponds to zone 17 and Segment 8 corresponds to zone 24. Segments 1-8: 1 = Partition #1 2 = Partition #2 3 = Partition #3 4 = Partition #4 5 = Partition #5 6 = Partition #6 7 = Partition #7 8 = Partition #8 LOCATION 31 CONFIGURATION GROUP ZONES 25-32 (8 segments, numerical data) Location 31 contains the Configuration Group (Zone type) for zones 25-32. Segment 1 is for zone 25; Segment 8 is for zone 32. Default configurations are found in the table on page 8. NX-216 ZONE EXPANDER 9

LOCATION 32 PARTITION SELECT ZONES 25-32 (8 segments, feature selection data) Location 32 is used to select the partition(s) that zones 25-32 reside in. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition it will only be active when all partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1 corresponds to zone 25 and Segment 8 corresponds to zone 32. Segments 1-8: 1 = Partition #1 2 = Partition #2 3 = Partition #3 4 = Partition #4 5 = Partition #5 6 = Partition #6 7 = Partition #7 8 = Partition #8 LOCATION 33 CONFIGURATION GROUP ZONES 33-40 (8 segments, numerical data) Location 33 contains the Configuration Group (Zone type) for zones 33-40. Segment 1 is for zone 33; Segment 8 is for zone 40. Default configurations are found in the table on page 8. LOCATION 34 PARTITION SELECT ZONES 33-40 (8 segments of feature selection data) Location 34 is used to select the partition(s) that zones 33-40 reside in. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1 corresponds to zone 33 and Segment 8 corresponds to zone 40. Segments 1-8: 1 = Partition #1 2 = Partition #2 3 = Partition #3 4 = Partition #4 5 = Partition #5 6 = Partition #6 7 = Partition #7 8 = Partition #8 LOCATION 35 CONFIGURATION GROUP ZONES 41-48 (8 segments of numerical data) Location 35 contains the Configuration Group (Zone type) for zones 41-48. Segment 1 is for zone 41; Segment 8 is for zone 48. Default configurations are found in the table on page 8. LOCATION 36 PARTITION SELECT ZONES 41-48 (8 segments, feature selection data) Location 36 is used to select the partition or partitions that zones 41-48 reside in. A zone may reside in any combination of the 8 partitions. If a burglary zone resides in more than 1 partition it will only be active when all partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Location 36 has 8 segments. Segment 1 corresponds to zone 41 and Segment 8 corresponds to zone 48. Segments 1-8: 1 = Partition #1 2 = Partition #2 3 = Partition #3 4 = Partition #4 5 = Partition #5 6 = Partition #6 7 = Partition #7 8 = Partition #8 10 NX-216 ZONE EXPANDER

NOTES NX-216 ZONE EXPANDER 11

8. SPECIFICATIONS OPERATING POWER AUXILIARY POWER CURRENT DRAW LOOP RESISTANCE LOOP RESPONSE OPERATING TEMPERATURE DIMENSIONS SHIPPING WEIGHT 12VDC Supplied from NX-8 or NX-320 Supplied from NX-8 or NX-320 Current limited to 100mA 30mA 300 Ohms Maximum Selectable 50mS or 500mS 32 to 120 degrees F 6.0" Wide 2.125" High 1.0" Deep 2 lbs. GE INTERLOGIX 1420 NORTH MAIN STREET GLADEWATER, TEXAS 75647 Main 800-727-2339 Technical Support 800-727-2339 Outside the US 903-845-6941 Tech Support Fax 903-845-8409 Main Fax 903-845-6811 Sales & Literature 800-547-2556 Web: www.caddx.com www.ge-interlogix.com NX-216 INSTALLATION MANUAL NX216IG02 REV. G (09-24-02)