M-Bus Master MultiPort 250D/L

Similar documents
M-Bus Master. Data sheet. MultiPort 250D/L

M-Bus Master MultiPort 250D

M-Bus Modules. Data sheet. for MULTICAL 403

Wired M-Bus Modules. Data sheet. for MULTICAL 403 and 603

RS-485 module. Data sheet. for electricity meters

LON-module for MULTICAL 601

Analog input module. Data sheet. for MULTICAL 603

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Metering systems 0447EN October 2013 M-BUS centralisation System overview

Technical Manual for RTCU M10 / M10G

GSM Modem 5. Installation and User Guide. English

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

SCB-C08 USB to RS232/422/485 Converter

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

Meter Bus. Intelligent Communication

BACnet MS/TP-module. Data sheet. for MULTICAL 403 and 603

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

PD 601 DPI with RS-232 P-NET Interface PD Series 600

Hardware Manual RM CANview

Documentation. M-Bus 130-mbx

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

SER-4485-SI-M USER S MANUAL

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

WiFi to RS-232 adapter user manual

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

DL-FHD2 Quick Install Guide

F1000 User's Manual. (Version: V1.01)

CMi- box. M-Bus Metering Gateway for Mobile Network GSM/GPRS TCP/IP. CMi-Box

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

Technical specification Marine Master Clock

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

General Operating, Maintenance and Installation Manual

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

Manual Fiber Optic Interfaces

Wireless M-Bus modules for MULTICAL 403 & 603

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Touch-it XELO Automation glass 18,5

Serial PROFIBUS Interface

The Wireless Connectivity Expert

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

TABLE OF CONTENTS. Communication Functions

Converter Box Data Sheet

/ Type approved according to:

Technical data. General features of the DVIVision series. English. Video: Interfaces to computer. Audio:

Serial Communication Converters & Adapters Instruction Manual

Bluetooth V4.1 BLE RS-232 Serial Adapter Model: BLE-232B Bluetooth V4.2 BLE RS-232 Serial Adapter Model: BLE-232C

Technical Manual for the RTCU M11i Series

General Specifications. P2-SCM Serial Communications

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

MEC-COM-M134. User s Manual

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

USER MANUAL HPS-120. About this product: Your Communications Solutions Provider

Manual Industry Interfaces

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

Solution description. READy. The modern and efficient solution for reading smart water, heat and cooling meters

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232C

MPC / 7. First interface. distance up to 15m, speed up to 19,2Kbit/s. 4 band 850/900/1800/1900 MHz. Second interface (galvanically isolated)

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

Section 1 Introduction

Solenvis SL80 Pulse to M-Bus Converters

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

MPC / 6. First interface. distance up to 15m, speed up to 19,2Kbit/s, GSM modem support. 4 band 850/900/1800/1900 MHz

MULTITERM Pro G2 and G3 RF

L-MBUS20/L-MBUS80. User Manual. M-Bus Level Converter. LOYTEC electronics GmbH

Appendix. Specifications

Active RFID Reader User Manual

ME-9000i isolated Serial Interface Board, RS232, RS422, RS485

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2

EasySYNC Ltd. USB to Serial Converters Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

TG Technical specifications

icex-cmtm General specs and Installation guide

Product Overview. Interface Converters and Plug-in Modules

8520/8520R. User Manual

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

PXR11 PXR12. System controllers DESIGO PX

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

PCI Express 4-Port Industrial Serial I/O Cards

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

1 port RS-232 Device Server

MIC-2 Multi-instrument DATA SHEET

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

OnCell G3100 Series Quick Installation Guide

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

LM058 Bluetooth Serial Adapter

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Transcription:

M-Bus Master MultiPort 250D/L Remote reading with M-Bus Up to 250 meters per M-Bus Master and by cascading, up to 1250 meters in a system Supporting primary/secondary/enhanced secondary addressing and wild card search with collision detection 300/2400/9600 Baud communication speed Connection via RS-232, RS-485, USB, GSM/GPRS and optical eye * Local reading via display with backlight * PIN code protection * M-Bus Master MultiPort 250L Power Request Data Overload Application M-Bus is a bus system, which is specially suited for communication with heat, cooling, water, electricity and gas meters. The system consists of an M-Bus Master and meters with M-Bus interface. Various meter types and brands can be installed and co-exist in the same M-Bus network. The network is typically realised by the use of twisted pair cabling. The connected meters are read out either by the M-Bus Master directly, where data are shown in the display, or by a reading program connected to one of the M-Bus Master s communication ports. The M-Bus Master acts as power supply for the M-Bus modules in the meters. This enables a long battery lifetime for meters with battery supply. The total size of an M-Bus network using Kamstrup M-Bus Masters can be up to 1250 meters when secondary addressing is used. When more M-Bus Masters are coupled in cascade, a total cable length of approximately 14 km can be achieved. Using primary addressing, a network of up to 250 meters is possible. M-Bus master 250D is provided with a smart energy-saving feature to reduce power consumption when no meter readings are being carried out. During installation and maintenance on the M-Bus network, no PC is needed as network analysis, meter search and meter reading can be performed directly on the M-Bus Master by use of the M-Bus Master s push buttons and display*. M-Bus is standardized according to EN 13757-2 and EN 13757-3. * Only 250D Industrivej 28, Stilling DK-8660 Skanderborg Tel: +45 89 93 10 00 Fax: +45 89 93 10 01 info@kamstrup.com www.kamstrup.com

Content Functionality 3 Features 5 Connections and cabling 6 Communication 6 Connections 8 Dimensions 10 Technical data 11 Ordering 12 2 5810792_F1_GB_10.2014

M-Bus Master MultiPort 250D Power Request Data Overload M-Bus Master MultiPort 250D Power Request Data Overload M-Bus Master MultiPort 250D Power Request Data Overload M-Bus Master MultiPort 250D/L Functionality The Kamstrup M-Bus Master MultiPort 250D/L is an M-Bus Master designed for connection of up to 250 meters with M-Bus interface. MultiPort 250D/L can be used as master, transparent level converter and repeater. 250 meters 250 meters 250 meters With 4 repeaters, up to 1250 meters and 14 km cable length M-Bus Master 53+54 53+54 RS-232, RS-485, USB M-Bus Repeater M-Bus Repeater... RS-232: RS-485: USB: 15 15 m 1200 m 5 m 2.8 km 2.8 km Up to 14 km M-Bus Master MultiPort 250D As M-Bus Master, it is operated by the use of the display and the 6 associated push buttons. The display is designed with an easy-to-use menu structure making it easy to perform scanning, reading and analysis on the M-Bus network. Further, it continuously informs about the actual status on the M-Bus net with e.g. unit load and ongoing communication. The operation via push buttons can be protected with a PIN code. Left functionality button Down Back Right functionality button Up OK 5810792_F1_GB_10.2014 3

Functionality M-Bus Master as level converter As level converter, one or more of the integrated communication ports are connected to a reading system, a controller or the like, from where the communication is initiated. MultiPort 250D/L can be accessed from more ports where the integrated port controller prevents any collision. M-Bus Master as repeater The repeater function provides the possibility of extending the network size in respect of both cable length and number of installed meters. Depending on cable type and installation, the total cable length is up to approx. 10 km, and max 1250 meters can be connected. Setting for master or repeater mode Module area A module area provides possibilities for additional communication forms such as GSM/ GPRS as well as future functionalities. Web server MultiPort 250 Via the built-in web server, configuration and operation of the M-Bus Master can be performed remotely. 4 5810792_F1_GB_10.2014

Functionality LED 4 LEDs show status of mains power, data communication between M-Bus Master and modules as well as overload and short circuits in the M-Bus network. M-Bus Master MultiPort 250L Power Request Data Overload Power Request Data Overload Features MultiPort 250D/L is designed for indoor installation and the protection class can be up to IP67. Usable as M-Bus Master, repeater and level converter 128x64 pixels LCD display with backlight * Display reading supporting all Kamstrup meters as well as non-kamstrup meters * Primary, secondary and enhanced secondary addressing Collision detection with break signal Up to 250 slaves per M-Bus Master Integrated repeater functionality Up to 4 repeaters in one system = totally 1250 meters Up to 14 km cable length Up to 9600 Baud communication speed Byte recovery Echo suppression Transient protection Integrated USB, RS-232, RS-485 and optical eye* with automatic port controller Module area e.g. for GSM/GPRS module All ports are transparent and galvanically isolated from the M-Bus network Integrated web server for remote configuration and operation PIN code protected display and optical eye * Event loggers for both M-Bus and power * Smart energy-saving feature * Cable inlet via 9 cable unions Local and remote firmware upload for future functionality Up to IP67 * Only 250D 5810792_F1_GB_10.2014 5

Connections and cabling Communication All connections in MultiPort 250D/L are screw terminals. The M-Bus output consists of 4 pairs of parallel coupled screw terminals accepting cable sizes up to 2 mm². The cabling topology is typically star or bus or a combination of both. The cable type is typically unshielded twisted pair with a diameter of up to 1.5 mm². The cable connection is polarity independent. Communication is half duplex allowing two-way communication with one slave at a time. Transparent reading MultiPort 250D/L is equipped with the following communication ports for communication with e.g. remote reading programs, BMS systems and controllers: RS-232 GSM RS-485 GPRS * OPTICAL USB * Only 250D When more communication ports are simultaneously used, an integrated port controller secures that only communication via one port at a time is possible. Communication via above ports is transparent and includes collision detection. Communication speeds supported are 300/2400/9600 Baud. Local scanning on MultiPort 250D When scanning the M-Bus network from the M-Bus Master, both primary and secondary scanning can be used. Communication speeds 300, 2400 or 9600 Baud can be used individually as well as all 3 speeds in combination. 6 5810792_F1_GB_10.2014

Communication Local reading on MultiPort 250D When reading MULTICAL meters from the M-Bus Master, both M-Bus specific and manufacturer specific data are shown on the display. From other meters, M-Bus specific data are shown. M-Bus addressing Primary, secondary and enhanced secondary addressing are supported. Due to the integrated collision detection, wild card search is allowed when using secondary and enhanced secondary addressing. By wild card search, some or all digits of the M-Bus modul s secondary or enhanced secondary addresses can be replaced by wild cards when searching for meters. Primary addressing (001-250) Each meter needs a unique primary address between 001 and 250. Using the same address for more than one meter will result in collision and it is not possible to read the meters. Kamstrup M-Bus modules will automatically use the last 2-3 digits of the customer number as their primary address. Secondary addressing (00000000-99999999) Using secondary addressing, the last eight digits of the meter number are used as M-Bus ID number. Kamstrup MULTICAL meters use the customer number as their secondary address. The customer number is configurable. Enhanced secondary addressing (00000000-99999999/00000000-99999999) The meter s serial number is used for enhanced secondary addressing. This number is unique to each meter and cannot be changed after production. GSM/GPRS M-Bus Master 250D/L can be fitted with the Kamstrup GSM 6H or GSM 8H modem enabling remote reading via GSM and GPRS. As remote reading program, Kamstrup PcBase III, PcNet III or USB Meter Reader are recommended. 5810792_F1_GB_10.2014 7

Connections Number Abbreviation Description Mains 134 N Neutral 135 L Live 136 PE Protective Earth USB 130 VCC Supply Voltage 131 D- Data- 132 D+ Data+ 133 GND Ground RS-485 137 A/- Transmit/Receive inverting pin 138 A/+ Transmit/Receive non-inverting pin 139 GND Ground RS-232 105 RxD Received Data 106 TxD Transmitted Data 107 GND Ground 108 DTR Data Terminal Ready 109 CTS Clear To Send 111 DSR Data Set Ready 112 RTS Request To Send M-Bus Repeater Input 53 L1 M-Bus input to Master in Repeater mode 54 L2 M-Bus input to Master in Repeater mode M-Bus Master Output 24 L1 M-Bus output from Master 25 L2 M-Bus output from Master 8 5810792_F1_GB_10.2014

Connections USB RS-485 Mains 100-240 V 50/60 HZ RS-232 M-Bus input for cascade mode 4 sets of M-Bus outputs 5810792_F1_GB_10.2014 9

Dimensions 168 210 184 10 5810792_F1_GB_10.2014

Technical data Electrical (M-Bus) Number of slaves per M-Bus Master 250 at 1 unit load per slave Number of slaves in total 1250 with 1 M-Bus Master and 4 repeaters Cable length per M-Bus Master Up to approx. 2800 m, depending on cable type, cable topology and number of connected slaves Cable length in total Up to approx. 14 km with 1 M-Bus Master and 4 repeaters Cable size Max 2 mm 2 Communication ports RS-232, RS-485, USB, optical eye*, GSM/GPRS (optional) Communication speeds 300/2400/9600 Baud Data frame 1 start bit, 8 data bits, 1 parity bit (even), 1 stop bit Addressing modes, transparent Primary/secondary/enhanced secondary Addressing modes, direct reading Primary/secondary Address range, primary 001-250 Address range, secondary 00000000-99999999 Address range, enhanced secondary 00000000-99999999/00000000-99999999 Bus mark/space 41 VDC/28 VDC Communication detection level 7 ma Collision detection level 25 ma Max normal operating level 375 ma Warning level 377 ma Overload level 500 ma Electrical GSM 6H 2G (GSM/GPRS/EDGE) Frequencies 900-1800 MHz Transmitting power 900 MHz class 4, 2 W Transmitting power 1800 MHz class 1, 1 W GPRS classes 8, B Communication speeds GSM 300/2400/9600 baud Communication speeds GPRS 300/2400 baud Electrical GSM 8H 2G (GSM/GPRS/EDGE) Frequencies 900-1800 MHz Transmitting power 900 MHz class 4, 2 W Transmitting power 1800 MHz class 1, 1 W GPRS classes 12, B EDGE class E2, 900 MHz, 0.5 W EDGE class E2, 1800 MHz, 0.4 W 3G (UMTS/HSPA) Frequencies 900-2100 MHz Class 4 900 MHz, 2 W Class 3 2100 MHz, 0.25 W * Only 250D 5810792_F1_GB_10.2014 11

Technical data Electrical (HTTP) Communication ports Communication speed Data frame Electrical (general) Power supply Power consumption RS-232, RS-485, USB 9600/38400 Baud 1 start bit, 8 data bits, no parity bit, 1 stop bit 100-240V 50/60 Hz Max 40 W Mechanical Operating temperature 0 55 C, non-condensing, indoor use Storage temperature -20 +60 C Protection class Up to IP67, depending on cabling Dimensions 210 x 168 x 64 mm (H x W x D) Weight 1 kg Approvals and Standards Approval CE mark Standards EN 13757-2, EN 13757-3 Ordering Description Order No M-Bus Master MultiPort 250L MBM-M200000 M-Bus Master MultiPort 250D MBM-M210000 M-Bus Master MultiPort 250D with GSM 6H 2G MBM-M210Z00 M-Bus Master MultiPort 250D with GSM 8H 3G MBM-M210U00 M-Bus Master MultiPort 250L with GSM 6H 2G MBM-M200Z00 M-Bus Master MultiPort 250L with GSM 6H 3G MBM-M200U00 RS-232 cable D-sub 9A, 145 cm 6699-335 USB cable, 145 cm 6699-336 GSM 6H 2G 670ZB0000000.1 GSM 8H 3G 670UB0000000.1 12 5810792_F1_GB_10.2014