Communication module to connect M-bus devices to POL6xx.xxx controllers.

Similar documents
s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Island bus expansion module

Resistance measuring module

Power supply module, bus connection module

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Digital input modules

Room unit with PPS2 interface

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Room unit with PPS2 interface

TXM1.8RB. TX-I/O Blinds module

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Room unit with PPS2 interface

Web interface BACnet/IP

ERF910. RF Repeater. Synco living

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RF adapter plugs, dimming

Immersion Temperature Sensors

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Climatix programmable controller

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Heating Circuit Controller

Electromotoric actuators

Heating Circuit Controller

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Super universal modules

Extension module for lighting control

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Climatix range. Climatix TM

Room automation station

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Airflow Pressure Sensor

Handheld Tool for VAV compact and modular controllers

Electrical Actuators

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Room unit with PPS2 interface

Electrical Actuators

Extension module for graphic Web functions for one automation station

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Extension module for BACnet over Ethernet / IP and graphic Web functions

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Extension module for Web functions generic

M-Bus Central Unit. Use

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

VAV modular controller

QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode

AEW Pulse Adapter. Building Technologies

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Non-communicating room controllers

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Room Temperature Controller

Electrical actuators

Compact universal controllers

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Room Temperature Controllers

Electrical Actuators

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

General information. Display. Supply voltage. Input current. Encoder supply. Output current

LPB/OpenTherm Gateway

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Room Temperature Controller

Energy Management BUS Adapter Type VMU-B 01

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Network node WTT56.. A6V _en--_c Building Technologies

Electromotoric actuators

General information. Display. Supply voltage. Input current

Energy Management BUS Adapter Type VMU-B

Interface converter for VAV compact controllers

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Semi flush-mounted room temperature controllers with LCD

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

BACnet/IP Web Interface

General information Engineering with Programming package. Display with display

Electromotoric actuators

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

General information. Display. Supply voltage. Input current

HVAC&R controller. Climatix C600. POL648.x0, POL688.x0, POL69x.x0

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

Transcription:

s 3 936 Climatix TM Climatix communication M-Bus module POL907.00/xxx Communication module to connect M-bus devices to POL6xx.xxx controllers. The POL907.00/xxx communication module offers the following features: Up to 6 M-bus slaves, such as heat, water or electricity meters, can be directly connected to the M-bus module (up to 30 slaves with M-bus repeater) Module and controller form the M-bus master; the module controls communication and the controller stores the data received from the slaves The M-bus module connects the Climatix control system to the slaves via the M-bus network and facilitates remote readout of the slaves data Connection of the M-bus module to the M-bus network is galvanically separated via optocoupler. The bus power supply is short-circuit-proof The module must be connected to the left side of a POL6xx.xxx controller The POL907.00/xxx communication module is part of the Climatix product range (also refer to Data Sheet 3900 and Mounting Instructions M3910). CB1Q3936en_01 30.03.2009 Building Technologies

The M-bus The M-bus (Meter bus) is a European standard for remote readout of heat meters. It is also suited for use with all other types of consumption meters plus various sensors and actuators. With its standardization as a galvanic interface for remote readout of heat meters, this bus will become more and more important for the energy industry. For more information about the M-bus, visit www.m-bus.com. Installation concept Technical data General data Dimensions W x H x D: 45 x 110 x 75 mm Weight excl. packaging 100 g Base Plastic, pigeon-blue RAL 5014 Housing Plastic, light-grey RAL 7035 Power supply Via system interface from controller DC 5 V (+5% / 5%), max. 400 ma M-bus M-bus interfaces Number of bus devices (M-bus slaves) Baud rate Plug-in terminals MP+ / MP- Galvanically isolated by optocoupler 2 wires, not interchangeable Without repeater, direct connection: - Max. 6 bus devices (6 standard loads of 1.5 ma) with external M-bus repeater: - Up to 30 bus devices (min. 25 bus devices via repeater) 300 / 600 / 1200 / 2400 / 4800 / 9600 baud Type of addressing Primary addressing using the addresses from 1 to 250 2 / 6

Connection terminals Equipped with plug (standard) 1 Phoenix FKCT 2,5 /2-ST Example FKCT For other types of plug (optional), refer to PolyCool range document 3900 (CB1Q3900en_xx) Solid wire Stranded wire (twisted or with ferrule) 0.5 2.5 mm² 0.5 1.5 mm² COMM interface plug Board-to-board ZEC1,0/10-LPV-3,5 GY35AUC2CI1 Board-to-board connector System interface Equipped with board-to-board plug ZEC1,0/4-LPV-3,5 GY35AUC2CI1 Cable types M-bus Refer to M-bus Manual Environmental conditions Operation IEC 721-3-3 Temperature -40...+70 C Humidity < 90 % r.h. Atmospheric pressure Min. 700 hpa, corresponding to Transport IEC 721-3-2 max. 3,000 m above sea level Temperature -40...70 C Humidity <95% r.h. Atmospheric pressure Min. 260 hpa, corresponding to max. 10,000 m above sea level Protection Degree of protection IP20 (EN 60529) Standards Product safety Automatic electrical controls EN 60730-1 Electromagnetic compatibility Immunity EN 60730-1 +A16 Emissions EN 60730-1 +A16 CE conformity EMC directive 2004/108/EC Low-voltage directive 2006/95/EC Listings UL916, UL873 CSA C22.2M205 RoHS directive 2002/95/EC (Europe) ACPEIP (China) Ordering data Climatix M-bus module POL907.00/STD 3 / 6

M-Bus service pin and LEDs for diagnostics Service pin button > LEDs for BSP and BUS diagnostics (green, red and yellow) Mode M-bus running and communication ok At least one M-bus device is not running No M-bus device is running Mode BSP running and communication with controller BSP running but no communication with controller BSP error (software error) BUS LED status Green on Yellow on Red on BSP LED status Green on Yellow on Red blinking at 2 Hz Commissioning notes Meter setting Prior to connecting the M-bus to the ACX51.26 M-bus card, the following meter settings must be made: Primary address from 1 to 250 (physical address) Baud rate 300 / 600 / 1200 / 2400 /4800 / 9600 baud Enabling the required data, storage no. = 0, tariff = 0 Energy in kwh Volume in m 3 Power in W Flow rate in l/h Flow temperature in C Return temperature in C Enabling the required data, storage no. = 1, tariff = 0 Date of set day: Day, month, (year) Energy in kwh on the set day Volume in m 3 on the set day Engineering notes The communication module is attached to the controller with a board-to-board connector The connection to the M-bus is made via the T1 port For service, use the M-bus service button Disposal notes The module contains electrical and electronic components and must not be disposed of together with household waste. Local and currently valid legislation must be observed! 4 / 6

Layout of POL907.00/xxx communication module Right side Left side 5 / 6

6 / 6 2009 Siemens Switzerland Ltd. Subject to change