Solenvis SL80 Pulse to M-Bus Converters

Similar documents
PADPULS2 M-BUS Pulse Input Modules

GmbH, Stettiner Str. 38, D Paderborn

GmbH, Stettiner Str. 38, D Paderborn. PadPuls M4L. Art.-No. IM002G: (Valid from M-Bus generation: $12)

GmbH, Stettiner Str. 38, D Paderborn. PadPuls M2. Art.No.: IM003G + IM003GB. (Valid from M-Bus generation: $40)

AB Axis Industries. Use

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

FALCON MJ Pulse/M-Bus operating instructions M-Bus module for Honeywell / Elster M100i and M120i waters meters

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

FALCON PR6/PR7 Operating instructions M-Bus module for Elster water meter with Falcon register

EW500 Series Energy Calculators FOR HEATING AND CHILLED WATER ENERGY METERING

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

M-Bus-Logger Data Logger

AMBUS IS M-Bus pulse collector

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

AEW Pulse Adapter. Building Technologies

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Converter Box Data Sheet

IntesisBox Modbus Server Fidelio IP

TS2M-Bus Protocol Converter / User Manual

MID approval no. DE-08-MI004-PTB004 Date of release

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

IntesisBox Modbus Server Panasonic

APP 700 Technical Specification

Manual Industry Interfaces

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

IntesisBox KNX SAMSUNG NASA Air Conditioners

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

IntesisBox Modbus Server KNX

Line Coupler, MDRC LK/S 2.1, GH Q R0001

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

Jazz-J. Jazz. Features:

7511 / / / 711 / / 731 / Preset 27

TCNM-ACBB1 Installation Manual

Communication module to connect M-bus devices to POL6xx.xxx controllers.

M-Bus Master. Data sheet. MultiPort 250D/L


Product data sheet accessories control and regulation Accessories AIRWIN

IntesisBox BACnet IP Server - M-Bus

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

multipulse, multilog Installation and operating manual All that counts. EnergyMetering

Meter Bus. Intelligent Communication

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

M-Bus Central Unit. Use

Installation and Operation Manual. INTEGRA BTU Meter System

IntesisBox KNX - AIRZONE

Buffered Power Supply PS-30DR v1.0

Jazz-J. Jazz. Features:

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

SK TU4-PBR Part number:

LON-module for MULTICAL 601

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Interface Module XC Level Converter / User Manual

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

OB735 Smart Energy Meter

M-Bus Master MultiPort 250D/L

IntesisBox ASCII Server - KNX

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

EW773 Series Ultrasonic Hydronic Meters DN FOR HEATING AND COOLING APPLICATIONS

Network node WTT56.. A6V _en--_c Building Technologies

Pen Drive USB Datalogger!

mark150s mark150/485s DDC controllers Summary

Neon pr. ph/ ORP measurement. Applications. Description

02/11/2015

IntesisBox Modbus Server - Honeywell XLS 80

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

IntesisBox Modbus Server Siemens Synova FC330A

UNIVERSAL CURRENT CONVERTER

MCX08M2 Programmable controller

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Manual Fiber Optic Interfaces

Modbus Server SIEMENS Algorex (printer port)

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

TM238LFAC24DR compact base M I/O V AC supply - CANOpen- internal RAM 1000 kb

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

SK TU4-CAO-C Part number:

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Smart Metering Application Description Product Page KNX-IMPZ-WZ-M Water Meter. In Home Water Meters Modularis WZ-M Product Group 10

M-Bus Modules. Data sheet. for MULTICAL 403

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Gateway BACnet IP/MS-TP slave KNX TP Code: EK-BJ1-TP-IP / EK-BJ1-TP-MSTP


Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Extruder Controls ExtruVision S

IP gateway, MDRC IG/S 1.1, GH Q R0001

EM271. Multi-channel power analyzer. Benefits. Description

Transcription:

Solenvis SL80 Pulse to M-Bus Converters The SOLENVIS SL80 series of devices connects meters with contact output to the M-Bus system. This is a simple and flexible solution for reading already installed gas, electricity, heat, water and steam meters. The power for the impulse adaptor is taken from the M-Bus. An integrated battery maintains the count function in case of a bus voltage failure. The capacity of the battery allows operation without M-Bus connection for guaranteed 7 years. During installation the SOLENVIS SL80 modules can easily be adapted to the pulse output of the meter using MBCONF configuration software. The measured medium, the pulse value, the pulse unit and the initial meter count are nearly free adjustable to the individual meter by setup software. An integrated security feature prevents data configuration after installation without opening the sealed housing. FEATURES Pulse Output to M-Bus Conversion Suitable for Electricity, Gas, Water and Heat Meters Powered from the M-Bus (EN1434-3 Standard) Battery Back-Up Guaranteed for 7 Years Floating Contact and S0 Contact Versions Available Connection Diagram The following picture shows a typical installation and configuration setup

Technical Data Power Supply Bus Operation Battery Expectancy Pulse Frequency Floating Contact S0 Interface M-SOLENVIS SL80: Supplied by M-bus, Switches automatically to battery at bus failure SOLENVIS SL80: 12..27Vdc, minimum 30mA Max. 1.5mA (1 unit load), no battery charge 7 years with only battery operation Max. 20Hz M-SOLENVIS SL801: Internal supply (3V, 3uA), Max return time 1ms M-SOLENVIS SL801-C0: According to DIN43864, Auxiliary 12..27Vdc, 30mA, max return time 0.25ms M-Bus Protocol Transmission Rate Addressing Cable Entry Operating Temperature Storage Temperature Housing EN1434-3 300, 2400 and 9600 baud (auto-detect) Primary and Secondary PG7 Cable Glands 0 C.. +60 C (10%.. 70% non condensing) -25 C.. +60 C SOLENVIS SL80 1: Black Plastics, IP50 SOLENVIS SL80 1-S0: Light Grey Plastics Mounting M-SOLENVIS SL801: Wall Mounted M-SOLENVIS SL801-S0: DIN-rail Mounted Dimensions M-SOLENVIS SL801: W100 x H88 x D35 mm M-SOLENVIS SL801-S0: W26 x H75 x D111 mm Agency Approvals Accessories CE PW3 M-Bus Level Converter for Up to 3 Meters PW60 M-W60 M-bus Master/Level Converter for 60 Meters Installation To deactivate the write protection the housing cover can be opened by removing the metal screws above at the left and below at the right. The unprotect pushbutton is then accessible from outside; the unit is unprotected by pressing this button. Use a suitable adhesive seal to prevent the housing from being opened unnoticed.

After opening the housing please lead the M-Bus cable through the left cable gland of the cover and connect the cable to the left terminal. Then do the same with the cable of the pulse generator (right side). Please connect an optional shielding to the marked terminal. Connect the shielding only at the SOLENVIS SL80 module end. Impulse devices with floating contacts (reed contacts) are connected to the terminals marked with pulse using any polarity. If cable shielding is available, it can be wired single-sided to the terminal marked with shield. Impulse devices with opto-couplers or electrically isolated transistor outputs must be connected to the pulse with the correct polarity. The left-hand terminal is the positive connection and the middle terminal the negative connection SOLENVIS SL80-S0 To deactivate the write protection the front cover of the housing cover can be removed by use of a small screw driver. The unprotect pushbutton is then accessible from outside; the unit is unprotected by pressing this button. Note: Afterwards please fix the cover oriented with the notch at the top. You can use a suitable adhesive seal to prevent the housing from being opened unnoticed. The M-Bus is connected polarity independent to the terminal M and M. Impulse devices with floating contacts (reed contacts) are connected to the terminals marked P- & P+ using any polarity. If cable shielding is available, it can be wired single-sided to the terminal marked S. Impulse devices with opto-couplers or electrically isolated transistor outputs must be connected to P- and P+ with the correct polarity. Impulse devices with the interface according to DIN 43864 are connected to the S+ and S- 0 00 terminals with consideration of the correct polarity. An additional power supply of 12VDC to 27VDC sourcing minimum 30mA current must be wired to the terminals U+ and U-. Note: You can use only one of the two pulse inputs of M-SOLENVIS SL80-S0. Protection Mode Configuration Device data can be protected against unauthorized configuration. The SOLENVIS SL80 can be switched to protection mode with a special M-Bus telegram. Subsequent changes to device parameters cannot be made in this operating mode. The protection mode can then only be disabled by opening the sealable housing and pressing the unprotect pushbutton. The SOLENVIS SL80 devices must be configured during the installation to match the corresponding meter. For example, if the gas meter single pulse equates 10 litres, then the SOLENVIS SL80 module is required to be configured with this setting. To connect the M-SOLENVIS SL80 module to M-BUS master the M-BUS address must be programmed. The Master has four primary M-BUS addresses available 1-4.

The configuration is carried out using CONF software that is freely available. The configuration tool is required to be connected via COM-port to a M-BUS level converter that converts the M-bus telegrams from RS232 to M-bus. The upper part of the window shows device templates for a number of conversion modules. The lower part of the window displays the communications options and de-bugging information on the devices. Once the device is connected via M-PW3 module to the MBCONF software, pressing CONNECT TO METER searches for the device (leave M-Bus address to 254 for search). Once the device is found the device specific information is displayed on the top part of the window. Typically at this stage the PRIMARY M-BUS ADDRESS and pulse counting configuration is required to be changed. COM-Port Baud Rate New M-Bus is the serial port of the PC to which the M-Bus level converter is connected. The selected port will be saved in an INI file and will be restored on startup. Therefore the COM-Port has to be configured only once Is the transmission speed of the serial port of the PC used for parameterization. Possible selections for this used M-Bus baud rate are 300, 2400 or 9600 baud. Note: Baud rates of more than 2400 baud are not supported by all M-Bus level converters which are available on the market! The selected baud rate must be identical to the baud rate of the M-Bus device. (see: New M-Bus Baud rate ). The SOLENVIS SL80 supports the baud rates 300, 2400 and 9600Bd allows reprogramming the baud rate of the M-Bus device. The new baud rate is Baud Rate sent to the M-Bus device after a change in the appropriate selection box. If the M-Bus slave accepts this command, it acknowledges the telegram

with the single character $E5 ($ for hexadecimal notation) using the old baud rate. Afterwards the device switches to the new baud rate. This button is not needed for the M-PADPULS M1, since it automatically detects the baud rate used by the master. M-Bus Address Connect to meter Manufact. Generation Type M-Bus State ZVEI optical mode Autom. Readout Log-Window is the primary address of the connected M-Bus slave. In a direct connection is the only one slave you can use the broadcast address 254. Using this address every M-Bus device must answer regardless of its own address. is used to request data from the slave. The type of device is then automatically recognized. The items Manufact., Generation, Type and M-Bus State will then be refreshed. New sheets are generated depending on manufacturer and type of the M-Bus device. is an item that shows the 3-letter manufacturer code after successful reading ( Connect to meter ). The item is read only shows the software revision of the firmware of the connected M-Bus device. The item is read only. shows the type (here: SOLENVIS SL80 M1) of the connected device. This item is read only. shows the M-Bus state of the connected device. This item is read only. If this option is activated, devices with an optical interface and protocol according mode to EN 1434-3 can be read and programmed using an optical reading head. The software always reads the data after writing, if this option is activated (useful for checking the correct programming). The so-called log window is always visible. All M-Bus communication steps are logged in this window. Data is displayed in hexadecimal notation. It is possible to mark outputs in the log window and copy them with the keys CTL-C to the windows clipboard. Then the data can be easily imported to any text editor for documentation. As soon as the max. storage capacity of the window is achieved, no more data is logged. If you want to log further, you must delete the logged data. The following buttons are also always visible: Notes: Erase log clears all outputs inside the log window. Exit terminates the program and stores the current setting of serial port no. into the INI file. In the view of a constant development of their products, the manufacturer reserves the right for changing technical data and features without prior notice. The consumer is guaranteed against any lack of conformity for 24 months from the time of delivery, according to the European Directive 1999/44/EC. The full text of guarantee is available on request from the seller.