GENERAL DESCRIPTION OF THE SYSTEM... 3

Similar documents
mark150s mark150/485s DDC controllers Summary

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation / Control / Monitoring Technique

Power Panel Integrated control, operation and visualization

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Millenium 3 logic controllers

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

Modular Two-Wire Telecontrol System

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

MCX08M2 Programmable controller

IMIO100 IMIO105. DDC controllers. Summary

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Voltage Transducer UMT516 / MT516

Millenium II +: general characteristics

LT : Suitable platforms for harsh environments

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

GS828. GPRS Data Logger

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

Programmable controller MCX06C

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

Remote I/O Product Specification

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Remote I/O Product Specification

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

Expansion Module HZS 541-1S

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Controlesta RCO-Compact

Internal Buffer/Boiler Module HZS 534

Data Transmitter 795. Data sheet

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG

EXD-TEVI Economizer Controller for Tandem Compressors

Small distributed I/O module

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere

AIAS. Technical description

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Measurement Systems Datascan Installation and User Guide

Monitoring and Controlling Energy Efficiency of Photovoltaic Installations

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

GS828-H. GPRS Data Logger

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

WI-I/O 9 Multi I/O Units

Smart Building Automation System Solutions

IntesisBox Modbus Server Panasonic

AUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

COMTRAXX COM460IP. BMS-Ethernet-Gateway

Programmable controller Type MCX06C

Remote I/O Product Specification

BMS-Ethernet-Gateway COM460IP

Z-PC Line Z-RTU. User Guide

Data Collecting Device. ProData. Operating Instructions. Dip Switches. Interface. Mode RS485- PT LON. Interface Analogue Input 0-20mA

THE SOLUTION. MFW product family DATASHEET. MFW - Modular radio telecontrol system. A system from the. INFOwww.ees-online.de

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

MCX06C Programmable controller

Micro Motion Model 7950 and Model 7951 Signal Converters

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Non-communicating room controllers

FEATURES DESCRIPTION FEATURES

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

IMS4 AMS 111 II M. Automatic Mobile Weather Station for military usage AMS 111 II M

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

Specifications SmartACU2000B-D-PLC SmartACU2000B-D-2PLC SmartACU2000B-D-PID/PLC SmartACU2000B-D-2PID/2PLC Configuration

EY-EM : Remote I/O module, ecolink

Non-communicating room controllers

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

mxcontrol Multifunction Controller

Residual overvoltage relay

Accessories. Embedded Control. Order number: Flash-RAM memory module, 128 K x 16 (for 680I) Accessories

Modbus RTU components. for automation in buildings, installations and systems

How to choose the correct Mount Kelvin central unit

RTU modules Create your infrastructures with peace of mind!

EXOcompact. Freely programmable controller

ATU800. Technical specification

DIAGNOSTICS PN# / / FSP

Monitoring various parameters with one power meter!

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

USER GUIDE ARDBOX ANALOG

Communicative heating controller, Ethernet

ISOMETER isoev425 with coupling device AGH420

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

InteliPro. Protection Relay for Parallel Applications. Technical Specification

ModBerryM500 series. Features of new. ModBerryM500 ASK FOR NEW RASPBERRY PI 3 B+

MX 62. Monitoring system for gas and flame detection. Certifications. Back up processor to ensure continual measurement (SIL 3 from EN 50402)

icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

Transcription:

Content GENERAL DESCRIPTION OF THE SYSTEM................................... 3 CONFIGURATIONS OF THE SYSTEM......................................4-7 Basic confi guration........................................................ 4 Confi guration with data transmission to PC...................................... 5 Confi guration with the programmer and GSM data transmission..................... 6 Confi guration with the use of existing programmer Micro LCD or Micro XL............. 7 Other confi gurations....................................................... 7 TECHNICAL DATA OF THE APPPLIED ELEMENTS...........................8-10 Micro XL central processing unit.............................................. 8 TIO 333 temperature controller............................................... 8 DST temperature sensor.................................................... 9 M-Bus Master 10 transmission converter....................................... 9 TRIAC 2 hardware controller................................................ 10 P2 relay................................................................ 10 Power suppliers.......................................................... 10 GSM modem............................................................ 10 AVALIABLE ELEMENTS OF THE SYSTEM................................... 11 2

ZPAS-Control M-Bus CHARACTERISTICS ZPAS-Control M-Bus system is a software based on elements of digital system of automatics. It allows for designing effective, cheap and reliable regulating and measuring systems. It is designated for application in professional management systems of climatic conditions in the data and telecommunication enclosures, enclosures for power industry, outdoor cabinets and on industrial facilities. AREAS OF APPLICATION 1) Data and telecommunication enclosures and enclosures for power industry: monitoring and controlling internal climatic conditions in the cabinets, monitoring accommodations in which the cabinets are installed with possibility of enriching the system with smokiness, vibration, movement, humidity, door being open sensors. Also installation of other sensoring elements is possible. 2) Outdoor cabinets: control of internal climatic conditions and other parameters influencing the work of the installed appliances in the cabinets placed in open area, informing the network s operator about irregularities in work of the system and localising failures. 3) Synoptic displays equipped with ZPAS-Control programmers: possibility of upgrading the system at a low cost (Micro PLC basic central processing unit is already installed in the display), simple upgrading of the system through connecting appropriate number of I/O modules by means of M-Bus data transmissions line. 4) Other areas of application: Openness and freedom of configuration allows to apply ZPAS-Control M-Bus system in an intelligent building, heat engineering industries, sewage systems, at municipal housing estates and many others areas. CONSTRUCTION OF THE SYSTEM Designing systems of automatics based on ZPAS-Control M-Bus system is easy thanks to application of universal hardware elements and software modules designed for controlling and regulating through typical controlling equipment. The system comprises central units, data transmission convectors, facility modules, sensors (temperature, humidity, smokiness, movement vibrations, access sensors) as well as hardware modules. Communication between central processing unit and peripherals (listed above) is based on standard data M-Bus enlarged by managing possibility. Basic parameters of M-Bus data transmission bus: - optional topology of cabling (the medium is 2 pair twisted pair cable), - connection of up to amount of 250 appliances in one exchange, - protecting data bus against change of poles, - power supply of end appliances directly from M-Bus data transmission bus. SOFTWARE ZPAS-Control M-Bus system is accompanied by attractive software with graphic interface working under control of Windows operating system. It is adjusted to compatibility with different superordinated systems of SCADA type. Regardless of them it allows to create operating panels adjusted to individual user s requirements. GENERAL DESCRIPTION OF THE SYSTEM 3

Basic configuration TIO 333 temperature controller DESCRIPTION OF FUNCTIONS ZPAS-Control M-Bus system in basic configuration enables continuous measurement of three temperatures in range between -55 to +125 C by means of DST temperature sensors (the length of the conduct - max. 10 m) connected to the programmed TIO 333 temperature controller. The producer provides software of the TIO 333 temperature controller for such a configuration (setting up the temperature values as well as hysteresis with accuracy of 1 C). Hardware controller (P2 relay or TRIAC 2 power module) designed to control elements like fan, heater and or others required by the customer can be connected to two-state outputs of the TIO 333 temperature controller (three outputs - transistorised keys, max. 30 V, 500 ma). The controller is supplied by 15 30 V DC power feeder. Confi guration of the system in its basic version makes it possible to enlarge construction of the system through adding consecutive modules according to the catalogue or according to project prepared on customer s request. INDEX OF REQUIRED ELEMENTS Symbol Element s name Quantity TIO-333 TIO 333 temperature controller 1 DST DST temperature sensor 3 TRIAC 2, P2 Triac 2 or P2 hardware controller 1 Z24VDC/1.5 24 V DC / 1.5 A power supplier 1 CONFIGURATIONS OF THE SYSTEM S1 - signalling device of the door being open S2 - signalling device of smokiness S3 - signalling device of vibrations and humidity T1 - temperature sensor 1 T2 - temperature sensor 2 T3 - temperature sensor 3 W1 - controlling output 1 W2 - controlling output 2 W3 - controlling output 3 4

Configuration with data transmission to PC DESCRIPTION OF FUNCTIONS Enlarging basic configuration by: - M-Bus Master 10 (60) data transmission convector providing signal conversion between RS232 interface and M-Bus transmission bus and - LMC software for personal computer (graphic panel), we additionally achieve: - possibility of multiple programming of the demanded temperature values as well as hysteresis (precision of regulation up to 1 C ) by means of attached PC with LMC software, - possibility to supply TIO 333 controller directly from M-Bus data transmission bus, - possibility to attach three two-state signalling devices (example microswitch, smokiness sensor, movement sensor, humidity sensor, vibration sensor and others) with registration of their activity on a graphic panel, INDEX OF REQUIRED ELEMENTS Symbol Element s name Quantity M10i M-Bus Master 10 1 TIO-333 TIO 333 temperature controller 1 DST DST temperature sensor 3 TRIAC 2 Triac 2 1 Z24VDC/1.5 24 V DC / 1.5 A power supplier 1 PANEL-GRAF LMC graphic panel software 1 - possibility of graphic visualisation of the appliances at work (the states of inputs and outputs) as well as registration of the temperatures on the charts. Confi guration of the system in such a version that allows for its further enlargement through adding subsequent modules according the catalogue or to the project prepared on customer s request. data transmission by M-Bus bus M-Bus Master 10 S1 - signalling device of the door being open S2 - signalling device of smokiness S3 - signalling device of vibrations and humidity T1 - temperature sensor 1 T2 - temperature sensor 2 T3 - temperature sensor 3 Operator s station W1 - controlling output 1 W2 - controlling output 2 W3 - controlling output 3 CONFIGURATIONS OF THE SYSTEM 5

Configuration with the programmer and GSM data transmission DESCRIPTION OF FUNCTIONS Enlarging basic configuration by: - Micro XL programmer (central unit), - data transmission GSM module and - LMC Logic Master Control software (graphic panel), we additionally achieve: - possibility of multiple programming of the demanded temperature values as well as hysteresis (precision of regulation up to 1 C) by means of attached PC, directly from Micro XL programmer, through cell phone or GSM modeme, - possibility to connect up to three two-state signalling devices (example microswitch, smokiness sensor, movement sensor, humidity sensor, vibration sensor and others) with registration of their activity on a graphic panel, - possibility of graphic visualisation of the appliances at work (the states of inputs and outputs) as well as registration of the temperatures on the charts, - possibility to store data - long term registration of the parameters with possibility of them being imported into the data base within a PC, - possibility to get connected to the facilities from any place on earth via GSM cell phone or stationary telephone connection. It allows for monitoring and remote management of the facilities, INDEX OF REQUIRED ELEMENTS Symbol Element s name Quantity MICRO-XL-2 Micro XL programmer 1 TIO-333 TIO 333 temperature controller 1 DST DST temperature sensor 3 TRIAC 2 Triac 2 1 Z24VDC/1.5 24 V DC / 1.5 A power supplier 1 TWIST SET GSM modem 1 PANEL-GRAF LMC graphic panel software 1 - previewer of registered charts allowing for mathematical working and creating new channels on the basis of already existing records, - possibility to configure archive data from different periods which allows to analyse changes in technological process in the long run, - software, providing graphic representation in Windows environment, adjusted to co-operation with different superordinated systems. It allows to create own operator s panels adjusted to particular needs. Confi guration of the system in such a version that allows for its further enlargement through adding subsequent modules according the catalogue or to the project prepared on customer s request. data transmission by M-Bus bus CONFIGURATIONS OF THE SYSTEM T1 - temperature sensor 1 T2 - temperature sensor 2 T3 - temperature sensor 3 W1 - controlling output 1 W2 - controlling output 2 W3 - controlling output 3 Operator s station Micro XL central processing unit SMS texts S1 - signalling device of the door being open S2 - signalling device of smokiness S3 - signalling device of vibrations and humidity 6

Configuration with the use of existing programmer DESCRIPTION OF FUNCTIONS On the facilities where Micro LCD or Micro XL programmer are already installed (example in synoptic displays manufactured by ZPAS SA), there is possibility of free enlargement of the system without a need of purchasing the programmer. Besides it is possible to collect information about work of appliances from the synoptic display widening in this way possibility to monitor the system. Confi guration of the arrangement in this version allows for further enlargement of the arrangement through adding subsequent modules according to the catalogue or prepared on customer s request. INDEX OF REQUIRED ELEMENTS Symbol Element s name Quantity TIO-333 TIO 333 temperature controller 1 DST DST temperature sensor 3 TRIAC 2 Triac 2 1 Z24VDC/1.5 24 V DC / 1.5 A power supplier 1 TWIST SET GSM modem 1 PANEL-GRAF LMC graphic panel software 1 Existing state synoptic display manufactured by ZPAS Operator s station Possibility of expansion SMS texts data transmission by M-Bus bus inputs/outputs out of facility S1 - signalling device of the door being open S2 - signalling device of smokiness S3 - signalling device of vibrations and humidity T1 - temperature sensor 1 T2 - temperature sensor 2 T3 - temperature sensor 3 W1 - controlling output 1 W2 - controlling output 2 W3 - controlling output 3 There is possibility of optional confi guration of the system - technical support at ZPAS SA, telephone +48-74-8720115, e-mail: dm@zpas.com Other configurations CONFIGURATIONS OF THE SYSTEM 7

Micro XL central processing unit DIMENSIONS: 105 x 90 x 60 mm to be installed on TS 35 rail POWER SUPPLY: 20 35 V DC, 20 24 V AC, I max = 150 ma MEMORY: RAM 1MB, EEPROM 192 KB, EPROM 512 KB COMMUNICATION PORTS: - one connector in I 2 C standard for LED64 intelligent matrix on synoptic display, Micro LCD etc., - two CAN connectors for fast I/O appliances + three RS232 connectors, - or one M-Bus Master connector for an appliance accounting thermal and electrical energy + two RS232 serial interfaces for local communication and connecting modem or transmission converters. CHARACTERISTICS: Modular programmable programmer. COMMUNICATIONAL PROTOCOLS: - MODBUS RTU of SLAVE and MASTER version for industrial programmers, - M-Bus of Master version according to CEN/TC 176 WG4 and EN 1434-3 norm to meters of thermal and electrical energy, - GAZ-MODEM to draw data from resolvers and gas correctors, - POZYTON to LZM/LZQM meters of electrical energy according to IEC 1107 norm, - AT commands GSM to GSM modems for SMS texts and data transmission by cell contact. TIO 333 temperature controller TECHNICAL DATA OF THE APPPLIED ELEMENTS DIMENSIONS: 69 x 90 x 60 mm to be installed on TS 35 rail POWER SUPPLY: By M-Bus bus or from power supplier up to 24 V DC INPUTS/OUTPUTS: - 3 inputs for digital temperature sensors of DST type (DS18B20) - 3 two-state inputs (sygnalling of functioning): type: contact inputs; voltage on the open contact: cca 5 V; current of closed contact: cca 0.1 ma; resistance of ON contact - below 1 kω ; resistance of OFF contact - above 20 kω. - 3 two-state outputs (triac for example): type: transistorised keys; kind of output: turn on / turn off or PWM (8 bits); maximal voltage on the key: 30 V; maximal current of the key: 0,5 A; protection of the key: polymer fuse. TRANSMISSION LINE: - electrical standard: M-Bus SLAVE; - protocol: MODBUS-RTU; - drawn current: does not exceed 4 ma; - answer current: 18 20 ma; - overvoltage protection: TRANSIL diode 43 V, 600 W/ms; - input/output separation of from line; - polarity of lines: free. CHARACTERISTICS: Facility module for dissipated systems of automatics. 8

DST temperature sensor MEASUREMENT RANGE: from -55 C up to +125 C; hysteresis: 1 C; precision of the set-up of the temperature: 1 C; precision of the reading of the temperature: 0.1 C WAYS OF PROGRAMMING THE SENSOR: 1) Programming by means of TIO 333 controller as well as by Micro XL central processing unit. 2) Programming by means of: TIO 333 controller, M-Bus Master 10 transmission convector and PC with LMC software. DIMENSIONS: Maximal length of the conduit: 10 m CHARACTERISTICS: Digital, programmable DST temperature sensor to TIO 333 controller. M-Bus Master 10 transmission converter POWER SUPPLY: 10 30 V DC CHARACTERISTICS: Transmission converter between RS232 and M-Bus. APPLICATION: Supervising transmission line of M-Bus standard through RS 232 interface from PC computer, from Micro XL or Micro LCD programmer. CURRENT INTAKE: 0,1 A / 24 V DC; 0,2 A / 12 V DC MAXIMAL AMOUNT OF LOAD INTENSITY: 10 M-Bus standard receivers POWER SUPPLY PARAMETERS OF M-Bus LINE: - at no transmission: 16 ma max. - voltage on the M-Bus clamps at no transmission: 30 V DIMENSIONS: 34 x 90 x 60 mm GALVANIC SEPARATION: M-Bus - power supply of the converter: no separation M-Bus - RS232 interface: 100 V AC/DC Power supply of the convector through RS232 connection (M-Bus SLAVE): 100 V AC/DC PROTECTION OF M-Bus LINE: TRANSIL diode 43 V, 600 W/ms RS232 TRANSMISSION CONNECTION: drawer type - BH10 TRANSMISSION RATE: 300 up to 19200 baud NORMATIVE CONDITIONS OF RELATION: CEN/TC 176 WG 4 TECHNICAL DATA OF THE APPPLIED ELEMENTS 9

TRIAC 2 hardware controller APPLICATION: Turning on the appliances from 230 V AC network by means of contactless element (triac) through separated low voltage signal of key type. BASIC PARAMETERS: - Power supply: 230 V AC - Number of channels: 2 - Output current: 2 A / channel - Protection: common fuse - Controlling signal: transistorised key - Separation: from output and power supply - Dimensions: 34 x 90 x 60 mm P2 relay APPLICATION: Controlling double, independent switch contact of the relay by low voltage key (0-10 ma). BASIC PARAMETERS: - Power supply: 230 V AC - Number of channels: 2 - Contact parameters: 6 A / 250 V AC - Controlling signal: low voltage keys 0 10 ma - Separation between power supply, contacts and controlling. - Dimensions: 34 x 90 x 60 mm Power suppliers TECHNICAL DATA OF THE APPPLIED ELEMENTS RECOMENDED TYPES OF POWER SUPPLIER: Power supplier 2 x 24 V DC / 0.6 A Power supplier 24 V DC / 1.5 A UPS 24 V DC / 1.5 A with 7 VAh battery GSM modem CHARACTERICTICS AND APPLICATION: Dual band GSM modem with V 24 RS232 port built in allowing data and SMS texts sending. Adjusted to any GSM sell operator. BASIC PARAMETERS: - Power supply: 5 24 V AC - Work temperature range: -20 +55 C - Possibility to plug in an external antenna. 10

Avaliable elements of the system Element s name Symbol Central processing units MICRO-XL unit v.0 (2 x RS232, RAM 512 kb) MICRO-XL-0 MICRO-XL unit v.1 (3 x RS232, RAM 1024 kb, M-Bus Master 8) MICRO-XL-1 MICRO-XL unit v.2 (as MICRO-XL1 + SMS + GAZ-MODEM) - see page 8 MICRO-XL-2 MICRO-LCD terminal MIC-LCD Building Management System elements Sensor of outdoor temperature CZ Sensor of indoor temperature CP I/O module 3T, 3DI, 2DO without DST CTIO-332 I/O module 3T, 3DI, 3DO without DST (TIO 333 temperature controller) - see page 8 TIO-333 DST temperature sensor for TIO and CTIO - see page 9 DST Impulse resolver 8DI AIO-080 I/O Module 4AI, 4DI, 4DO (4-20 ma) AIO-444 I/O Module 4DI, 8DO AIO-048 I/O Module 8AI, 4DO (4-20 ma) AIO-804 Option - Pt 1000 for AIO (4-20 ma) 4xPt 1000 Converter PWM/A (0-10 V, 4-20 ma) PWM/A Power module 2 x TRIAC (TRIAC 2 hardware controller) - see page 10 TRIAC 2 Power module 2 x relay (P2 relay) - see page 10 P-2 M-Bus transmission converters M-Bus Master 60 M60i M-Bus Master 10 - see page 9 M10i M-Bus Slave - RS232 S3i M-Bus Master 400 M400 M-Bus Supervisor M-SUP Transmission converters RS485 insulated RS485i RS485 uninsulated RS485 CL 20/RS232 insulated CL20 Power suppliers Power supplier 2 x 24 V DC / 0.6 A - see page 10 Z24VDC/0.6 Power supplier 24 V DC / 1.5 A - see page 10 Z24VDC/1.5 UPS 24 V DC /1.5 A with 7 VAh battery - see page 10 UPS24VDC Software LMC - graphic panels PANEL-GRAF LMC - Logic Master Control LMC Others Voltage transmitter 230 V AC / 0-20 ma P220 GSM modem - see page 10 TWIST SET External telephone modem 56K Microswitch 83401S Vibration sensor Smokiness sensor OSD 23 Movement sensor Humidity sensor - hygrostat MFR 012i 11

Copyright by ZPAS SA, 2003