RS500-E6/PS4. Configuration Guide

Similar documents
TS700-E6/RS8. Configuration Guide

ESC2000 Configuration Guide

TS300-E8-PS4 Configuration Guide

RS500A-E6/PS4. Configuration Guide

Mainstream High Computing Node with AMD G34 Solution

Dual use as a high performance server and workstation

Capacity driven storage server. Capacity driven storage server

Duo Nodes 1U Server with High Speed Interconnection for AMD G34 Solution

New levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U

Pioneer DreamMicro. Rackmount 1U Server - S48 Series

High Density Computing for HPC Applications. Extreme High Density Computing Capability

New Levels of Performance and Interconnection for Datacenter Applications

Pioneer DreamMicro. Rackmount 1U Server - S58 Series

Streamlined feature-rich ATX UP serverboard. The most scalable I/O expandability

Extreme I/O Expandability with High VR Power Efficiency

Pioneer DreamMicro. Rackmount 2U Server S87 Series

NEC Express5800/R120e-1M System Configuration Guide

High Performance Computing

G-MAX TM. ATX Series User s Manual

DESERT STORM WS-TS700

ThinkServer RD630 Photography - 3.5" Disk Bay*

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

FWA-6280A User Manual 1. FWA-6280A User Manual

NEC Express5800/R120d-2M Configuration Guide

FCC COMPLICANCE STATEMENT

Altos T310 F3 Specifications

Acer AT110 F2 Specifications

Acer AR320 F2 Specifications

HostEngine 4U Host Computer User Guide

HostEngine 5URP24 Computer User Guide

E8431 First Edition Model: T00CP

USB-L111. USB-L111 User Manual TPM. Version: V M05. To properly use the product, read this manual thoroughly is necessary.

Entry workstation with ultra-quiet and extreme I/O performance design. Up-to-date 22nm Processors, Latest Intel Platform Ready

MIL-STD Rugged Computer User's Manual. Version 1.0 Revision Date: July. 05, 2017 THOR200. MIL-STD Rugged Computer

ThinkServer RD450 Platform Specifications

AMS Series. Fanless System

iops-18 User Manual 2013 Oct V1 IBASE Technology Inc.

NEC Express5800/R120h-2M System Configuration Guide

Altos R320 F3 Specifications. Product overview. Product views. Internal view

ASUS Strix Tactic Pro Gaming Keyboard

HostEngine 3U Host Computer User Guide

NEC EXPRESS5800/R320a-E4 Configuration Guide

HostEngine 4U Host Computer User Guide

Acer AR320 F1 specifications

USB Personal Video Recorder. USB Hybrid TV Tuner. (USB2.0 / 1.1 PNP TV Capture Box) UAD-880 User s Guide

HostEngine 4U Host Computer User Guide

Acer AT310 F2 Specifications

RS U, 1-Socket Server, High Performance Storage Flexibility and Compute Power

Home Theater PC Chassis

B85-PRO GAMER. Motherboard

NEC EXPRESS5800/R320b-M4 Configuration Guide

NEC EXPRESS5800/R320a-E4 Configuration Guide

NVR-CV. Network Video Recorder Hot-Swappable Tray for 3.5 HDD x 4 or 2.5 HDD x 4 Gigabit Ethernet x 2 COM x 2, USB2.0 x 6. VGA x 1, DVI-D x 1

Essentials. Expected Discontinuance Q2'15 Limited 3-year Warranty Yes Extended Warranty Available

RAID Configuration Guide. Motherboard

HOME THEATER PC CHASSIS. Model: HTPC 7000B. HTPC Chassis Quick Installation Guide

Most Powerful Dual LGA2011 Serverboard in 12 x10 Compact Size

NEC EXPRESS5800/R320b-M4 Configuration Guide

SU Dual and Quad-Core Xeon UP Server

Part Number Unit Descriptions

Installation Manual of DS-9600NI-H8 DS-9600NI-H8. Installation Manual UD.7L0202A1730B01

Manual AMS ibase

NEC Express5800/GT110e Configuration Guide

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

System Configuration Guide

Combat Model with Advanced I/O Design. Designed to support three legacy PCI Devices. Dual Intel I210AT Gigabit Ethernet

HOME THEATER PC CHASSIS

NEC Express5800/R120h-2E System Configuration Guide

iosafe SERVER 5 Quick Start Guide

ThinkServer RD530 Photography - 3.5" Disk Bay*

NEC Express5800/B110d Configuration Guide

NEC Express5800/R120e-2E Configuration Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide

HP ProLiant MicroServer

Product Introduction of Inspur Server NF5280M4

3960 Series. XTREME Edition. The Professional s Choice. Key Features

Sugon TC6600 blade server

QuickSpecs. HPE Cloudline CL7100 Server. Overview

HOME THEATER PC CHASSIS

NEC EXPRESS5800/E110d-1 Configuration Guide

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

NEC EXPRESS5800/GT110d-S Configuration Guide

RS-200-RPS-E 2U Rackmount System with Dual Intel

CSE-M14T Mobile Rack USER'S GUIDE

ARP992/ ARP992-B User Reference Manual

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

TEOS Hardware System TEOS 8416 / TEOS 1016/ TEOS1216

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

NEC Express5800/GT110e-S Configuration Guide

Troubleshooting Server Hardware or Software. Issue. Troubleshooting Operating System and Drivers Installation

iosafe BDR515 Hardware Guide

Cisco MCS 7845-H1 Unified CallManager Appliance

NEC Express5800/GT110e-S Configuration Guide

EVO-TP Hardware System

291-MB333-04P7F EN1070K

GW2000h w/gw175h/q F1 specifications

NEC EXPRESS5800/R320a-E4 Configuration Guide

M1034W Engineering Workstation

The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Transcription:

RS500-E6/PS4 Configuration Guide

E4332 First Edition V1 February 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. ( ASUS ). ASUS provides this manual as is without warranty of any kind, either express or implied, including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose. In no event shall ASUS, its directors, officers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product. Specifications and information contained in this manual ae furnished for informational use only, and are subject to change at any time without notice, and should not be construed as a commitment by ASUS. ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual, including the products and software described in it. Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing. Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners benefit, without intent to infringe. II

Contents Contents... III Revision history... III Safety information... IV Chapter 1: Product introduction 1.1 Key features... 1-2 1.2 System overview... 1-3 1.3 Front panel features... 1-4 1.4 Rear panel features... 1-4 1.5 System specifications... 1-5 Chapter 2: Components 2.1 Upgrading CPU and CPU heatsink... 2-2 2.2 Upgrading system memory... 2-4 2.3 Upgrading hard disk drives... 2-6 2.4 Installing ASUS PIKE RAID module... 2-7 2.5 Installing ASUS Server Management Board... 2-8 2.6 OS support list... 2-9 Revision history Revision Revision history Date V1 First release of RS500-E6/PS4 configuration guide February 2009 III

Safety information Electrical Safety Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged. To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. When adding or removing any additional devices to or from the system, contact a qualified service technician or your dealer. Ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you service. If the power supply is broken, do not try to fix it by yourself. Contact a qualified service technician or your dealer. Operation Safety Servicing of this product or units is to be performed by trained service personnel only. Before operating the server, carefully read all the manuals included with the server package. Before using the server, ensure all cables are correctly connected and the power cables are not damaged. If any damage is detected, contact your dealer as soon as possible. To avoid short circuits, keep paper clips, screws, and staples away from connectors, slots, sockets and circuitry. Avoid dust, humidity, and temperature extremes. Place the server on a stable surface. This product is equipped with a three-wire power cable and plug for the user s safety. Use the power cable with a properly grounded electrical outlet to avoid electrical shock. Lithium-Ion Battery Warning CAUTION! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer s instructions. CD-ROM Drive Safety Warning CLASS 1 LASER PRODUCT Heavy System CAUTION! This server system is heavy. Ask for assistance when moving or carrying the system. IV

Chapter 1 This chapter describes the key features of RS500-E6/PS4. It includes the product overview and general specifications. Product introduction 1-

1.1 Key features Mass Storage & Memory Capacity RS500-E6/PS4 has four 3.5 hot-swap HDD bays to support SATA or SAS HDDs, meeting the demand of mass storage, using 12 DDR3-DIMM slots for enhanced memory scalability. Scalable & Flexible RAID solution ASUS PIKE upgrade kit ASUS unique PIKE upgrade kit meets the demand of direct SAS RAID upgrade solution, connected through a unique slot without sacrificing system expandability, and compatible with all ASUS Tylersburg system. User-friendly Server Remote Management - ASMB4-iKVM upgrade kit With ASMB4 upgrade kit in remote severs, Local users can remote-manage remote severs by keyboard, video monitor and mouse (KVM) of local side computer, and share the date saved in a local side drive to remote target servers. It provides the most quick and efficient way to recover the system in service and significantly improves the system s availability by the complete remote management tools. Virtualization Support With Virtualization, Different application and operation software could share hardware equipments in one system, It could increase server utilization, and reduce IT total cost of ownership.rs500-e6/ps4 supports virtualization and is certified by VMware. Green Design with high power efficiency With 80+ PFC high efficiency power supply, RS500-E6/PS4 is able to reduce the power loss and power consumption, and save power bill for users. ASUS EPU technology, which intelligently calibrates the best possible settings to ensure the best power efficiency, and all Japan-made 5000hr ultra durable conductive polymer capacitors onboard provide durability, improved lifespan. 1-2 Chapter 1: Product introduction

1.2 System overview 6 7 9 8 1 2 3 4 5 Items Items 1. Central processing unit (CPU) 6. PIKE 1064E/1078 RAID module (optional) 2. CPU heatsink 7. Riser card bracket 3. System memory 8. Riser card 4. Hard disk drives 9. ASUS Server management board (optional) 5. HDD trays ASUS RS500-E6/PS4 1-3

2 1 1.3 Front panel features Rack screw Hot-swap HDD bays Rack screw Optical drive USB ports HDD Access LED LAN2 LED LAN1 LED Message LED Reset button Location LED Location switch Power button Power LED 1.4 Rear panel features PS/2 keyboard port PS/2 mouse port VGA port Serial port USB ports LAN port 3* Power supply fan Power cord connector Expansion slots LAN port 2 LAN port 1 * The port is for ASUS ASMB4-iKVM controller card only. 1-4 Chapter 1: Product introduction

1.5 System specifications Model Name Processor / System Bus Core Logic ASUS Features Memory Expansion Slots Storage HDD Bays Smart Fan ASWM 2.0 Total Slots Capacity Memory Type Memory Size Total PCI/PCI-X/ PCI-E Slots Slot Type Additional Slot SATA Controller SAS Controller I = Internal A or S will be hot-swappable RS500-E6/PS4 2 x Socket LGA1366 Intel Xeon 5500 series processors (45nm) Quad-Core / Dual-Core QPI 4.8 / 5.86 / 6.4 GT/s Intel 5500 I/O Hub Intel ICH10R 12 (3-channel per CPU, 6 DIMMs per CPU) Maximum up to 96GB (RDIMM) Maximum up to 48GB (UDIMM) DDR3 1333 / 1066 / 800 Reg DIMM / Unbuffered DIMM with ECC 512MB, 1GB, 2GB, 4GB and 8GB 3 1 x PCI-E G2 x16 slot (G2 x8 link) (Full-Height/ Half-Length) 1 x PCI-E G2 x8 slot (G2 x8 link) (Full-Height/ Half-Length) 1 x PIKE slot with PCI-E G1 x4 link Intel ICH10R: 6 x SATA2 300MB/s ports Intel Matrix Storage (for Windows only) - Supports software RAID 0, 1, 5 & 10 LSI MegaRAID (for Linux / Windows) - Supports software RAID 0, 1 & 10 Optional: ASUS PIKE 1064E 4-port SAS RAID card - Supports software RAID 0, 1 & 1E ASUS PIKE 1078 8-port SAS RAID card - Supports hardware RAID 0, 1, 10, 5 & 6 4 x Hot-swap 3.5 SAS/SATA HDD Bays (continued on the next page) ASUS RS500-E6/PS4 1-5

Networking LAN 2 x Intel 82574L PCI-E GbE LANs Graphic VGA Aspeed AST2050 / 8MB Auxiliary Storage CD / DVD 1 x Slim-type Optical Device Bay Options: No Device / DVD-RW 1 x External Serial Port 3 x RJ-45 ports Onboard I/O 4 x USB 2.0 ports (Front x 2, Rear x 2) 1 x VGA port 1 x PS/2 keyboard port 1 x PS/2 mouse port Windows Server 2008 R2 Enterprise 32 / 64-bit Windows Server 2003 R2 Enterprise 32 / 64-bit OS Support RedHat Enterprise Linux AS5.0 32 / 64-bit SuSE Linux Enterprise Server 10.0 32 / 64-bit (Subject to change without any notice) Anti-virus Software CA etrust 7.1 anti-virus software (Optional) Out of Band Onboard IPMI Solution Management Remote ASMB4-iKVM for KVM-over-IP support (Optional) Solution Hardware Software ASUS ASWM 2.0 and SNMP Dimension (HH x WW x DD) 615mm x 444mm x 43.4mm Net Weight Kg (CPU, DRAM & HDD not inclu ded) 14 Kg Power Supply 600W 80+ Single Power Supply Environment * Specifications are subject to change without notice. Operation temperature: 10 C ~ 35 C / Non operation temperature: -40 C ~ 70 C Non operation humidity: 20% ~ 90% ( Non-condensing) 1-6 Chapter 1: Product introduction

Chapter 2 This chapter lists the key components and optional accessories for the server system. Components 1-

2.1 Upgrading CPU and CPU heatsink The ASUS RS500-E6/PS4 supports 1-2 Dual-core / Quad-core Intel LGA1366 Xeon 5500 series processor. 6 5 4 1 3 2 2-2 Chapter 2: Components

Order P/N 90-S000U0590T 90-S000U0600T 90-S000U0610T 90-S000U0620T 90-S000U0630T 90-S000U0640T 90-S000U0650T 90-S000U0660T 90-S000U0670T 90-S000U0680T 90-S000U0690T 90-S000U0700T Description Dual-Core Intel Xeon E5502, 1.86G, QPI 4.8GT/s, 4MB L2, Quad-Core Intel Xeon E5504, 2.00G, QPI 4.8GT/s, 4MB L2, Quad-Core Intel Xeon E5506, 2.13G, QPI 4.8GT/s, 4MB L2, Quad-Core Intel Xeon E5520, 2.26G, QPI 5.86GT/s, 8MB L2, Quad-Core Intel Xeon E5530, 2.40G, QPI 5.86GT/s, 8MB L2, Quad-Core Intel Xeon E5540, 2.53G, QPI 5.86GT/s, 8MB L2, Quad-Core Intel Xeon X5550, 2.66G, QPI 6.4GT/s, 8MB L2, Quad-Core Intel Xeon X5560, 2.80G, QPI 6.4GT/s, 8MB L2, Quad-Core Intel Xeon X5570, 2.93G, QPI 6.4GT/s, 8MB L2, Quad-Core Intel Xeon W5580, 3.20G, QPI 6.4GT/s, 8MB L2, Quad-Core Intel Xeon L5506, 2.13G, QPI 4.8GT/s, 4MB L2, Quad-Core Intel Xeon L5520, 2.26G, QPI 5.86GT/s, 8MB L2, ASUS RS500-E6/PS4 2-3

2.2 Upgrading system memory The motherboard comes with twelve (12) Double Data Rate 2 (DDR2) Fully- Buffered Dual Inline Memory Modules (DIMM) slots. 1 DIMM_A2 2 DIMM_A1 3 DIMM_B2 4 DIMM_B1 5 DIMM_C2 6 DIMM_C1 7 DIMM_D2 8 DIMM_D1 9 DIMM_E2 10 DIMM_E1 11 DIMM_F2 12 DIMM_F1 12 11 10 9 8 7 1 2 3 4 5 6 Recommended memory configurations Installing one CPU CPU1 CPU2 DIMM slots C1 C2 B1 B2 A1 A2 D1 D2 E1 E2 F1 F2 1 DIMM V 2 DIMMs V V 3 DIMMs V V V 4 DIMMs V V V V 5 DIMMs V V V V V 6 DIMMs V V V V V V 1 DIMM V 2 DIMMs V V 3 DIMMs V V V 4 DIMMs V V V V 5 DIMMs V V V V V 6 DIMMs V V V V V V Installing two CPUs CPU1 CPU2 DIMM slots C1 C2 B1 B2 A1 A2 D1 D2 E1 E2 F1 F2 1 DIMM V 2 DIMMs V V 3 DIMMs V V V 4 DIMMs V V V V 5 DIMMs V V V V V 6 DIMMs V V V V V V 7 DIMMs V V V V V V V 8 DIMMs V V V V V V V V 9 DIMMs V V V V V V V V V 10 DIMMs V V V V V V V V V V 11 DIMMs V V V V V V V V V V V 12 DIMMs V V V V V V V V V V V V 2-4 Chapter 2: Components

Order P/N Description 90-S000I0300T DDR3 1333 ECC REG 1G SINGLE PACK 90-S000I0310T DDR3 1333 ECC REG 2G SINGLE PACK 90-S000I0320T DDR3 1066 ECC REG 1G SINGLE PACK 90-S000I0330T DDR3 1066 ECC REG 2G SINGLE PACK 90-S000I0340T DDR3 1333 ECC UNB 1G SINGLE PACK 90-S000I0350T DDR3 1333 ECC UNB 2G SINGLE PACK 90-S000I0360T DDR3 1066 ECC UNB 1G SINGLE PACK 90-S000I0370T DDR3 1066 ECC UNB 2G SINGLE PACK 90-S000I0380T DDR3 1333 ECC REG 1G (10 in 1) 90-S000I0390T DDR3 1333 ECC REG 2G (10 in 1) 90-S000I0400T DDR3 1066 ECC REG 1G (10 in 1) 90-S000I0410T DDR3 1066 ECC REG 2G (10 in 1) 90-S000I0420T DDR3 1333 ECC UNB 1G (10 in 1) 90-S000I0430T DDR3 1333 ECC UNB 2G (10 in 1) 90-S000I0440T DDR3 1066 ECC UNB 1G (10 in 1) 90-S000I0450T DDR3 1066 ECC UNB 2G (10 in 1) ASUS RS500-E6/PS4 2-5

2.3 Upgrading hard disk drives The system supports four hot-swap SATAII/SAS hard disk drives. 1 2 We recommend that you install identical drives of the same model and capacity for RAID configuration. Order P/N SAS HDD 90-S000H6210T 90-S000H6220T 90-S000H6230T SATAII HDD 90-S000H6240T 90-S000H6250T 90-S000H6260T 90-S000H6270T 90-S000H6280T Description HDD SAS 450G 3.5 with tray (Single Pack) HDD SAS 300G 3.5 with tray (Single Pack) HDD SAS 146G 3.5 with tray (Single Pack) HDD SATA2 1T 3.5 with tray (Single Pack) HDD SATA2 750G 3.5 with tray (Single Pack) HDD SATA2 500G 3.5 with tray (Single Pack) HDD SATA2 320G 3.5 with tray (Single Pack) HDD SATA2 250G 3.5 with tray (Single Pack) 2-6 Chapter 2: Components

2.4 Installing ASUS PIKE RAID module The ASUS PIKE RAID module allows users to create RAID function from SAS hard disk drives connected to the SAS connectors on the motherboard. SAS1 SAS2 SAS3 SAS4 1 5 SATA4 SATA3 2 3 SATA2 SATA1 SGPIO_SEL1 4 SGPIO_SEL1 2 1 On-Board 3 2 Add-On Card 1. Insert the RAID card into the PIKE RAID card slot, ensuring that it is completely seated on the PIKE RAID card slot. 2. Remove the data cables connected to the SATA connectors on the motherboard. 3. Connect the data cables, by numerial order, to the SAS connectors labeled SAS1-4 (red) on the motherboard. 4. Set the SGPIO_SEL1 jumper on the backplane to pin 2-3 when connecting data cables to the SAS connectors on the motherboard. 5. Install the i Button*. * PIKE 1078 module won t function if the i Button is not installed. Order P/N 90-C1SCM0-00UAY00Z 90-C1SCN5-00UAY10Z Description ASUS PIKE 1064E 4-port SAS Module (Support Integrated RAID 0, 1, 1E) ASUS PIKE 1078 8-port SAS RAID Module (Support Hardware RAID 0, 1, 5, 6, 10) ASUS RS500-E6/PS4 2-7

2.5 Installing ASUS Server Management Board ASUS Server Management Board is an Intelligent Platform Management Interface (IPMI) 2.0-compliant board that allows users to monitor, control and manage a remote server from the local or central server in local area network (LAN). ASUS Server Management Board Baseboard Management Controller (BMC) connector (14-pin BMC_FW1) ASMB4-iKVM Remote real-time access to servers with full control by keyboard, video monitor and mouse (KVM) of a single local computer from anywhere at any time. In addition, KVM function is based on BIOS-level access, therefore, even the server OS is down, the KVM module can still work to provide around-the-clock remote monitor and diagnosis through GUI (Web-based Graphical User Interface). Advanced server management functions including remote power on/off/reset, remote hardware health monitoring and system event log. Allows administrators to share the date saved in a local drive (floppy, CD/ DVD-ROM, flash device, HDD) to target servers, which makes data-sharing convenient. We recommend to use LAN port 3 (dedicated LAN) or LAN port 1 (shared LAN) for server management. LAN port 3 LAN port 1 Order P/N Description 90-C1SD80-00UAN00Z ASMB4-iKVM Module (6 in 1) 2-8 Chapter 2: Components

2.6 OS support list OS support list Windows Server 2008 Enterprise 32/64-bit Windows Server 2003 Enterprise 32/64-bit RedHat Enterprise Linux AS5.0 32/64-bit SuSE Linux Enterprise Server 10 32/64-bit Order P/N 90-S00SW7140T 90-S00SW7150T Description Windows Server 2008 STD 64-bit ENG Windows Server 2008 STD 64-bit TCH ASUS RS500-E6/PS4 2-9

2-10 Chapter 2: Components