Introducing DataVU. The New Range of Paperless Recorders from Partlow

Similar documents
Product Brochure. DataVU. Paperless Recorders.

DataVU 7 - Operating Manual

DataVU7 Paperless Recorder

JUMO LOGOSCREEN 600. Touching the future of recording: The new paperless recorder

JUMO LOGOSCREEN 600. Touching the future of recording: The new paperless recorder.

DataVU5 Entry Level Paperless Recorder

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

PR Series Paperless Recorders

AUTARKIC PROCESS MANAGEMENT

Inkjet Printer UX Series PREMIUM CLASS. Coding Solutions by Hitachi

Industrial Control SE-607

RD2000, 5.6" display. All models shown smaller than actual size.

KS 3012 PMA GENERAL DESCRIPTION

Domino G-Series i-tech thermal ink jet printers

horizontal and vertical bargraph channel display of a group with units and scalabled plus standardized measured values

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

eztrend QXe eztrend QXe Features Typical Applications Description Representative photograph, actual product appearance may vary.

Beautifully Simple Photofinishing Solutions.

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

J LOGOSCREEN nt Paperless Recorder with TFT display and CompactFlash card. B Operating Instructions 08.06/

Rely on us. Videographic recorders of the LINAX A300 family

Visual Supervisor Product Data

Voltage supply. AC 110 to 240 V +10/-15 %, 48 to 63 Hz AC/DC 20 to 30 V, 48 to 63 Hz. Interfaces

SX 6000 Paperless Recorder

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

CMC-99 (RS ) multichannel CONTROLLERS data recorders

Paperless recorder for capturing, visualizing, storing and evaluating measurement data

New Generation PR series. Paperless Recorders

Entry-level Paperless Recorder with CompactFlash card and life-cycle data management

ABB Control Technologies. ABB ScreenMaster paperless recorders Versatile recording anywhere

... with data security and Store & Forward

Portable Data LOGGING SYSTEMS. for Professionals

A great start to a successful future. AC500-eCo, the scalable control unit ideal for small applications NEW ABB

Eycon 10 and Eycon 20 Visual Supervisors Specification Sheet

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

Communication on a higher plane

40th. anniversary V-R SERIES. Suitable for hospitality and retail settings. discover more at. casio.co.uk/epos

DIAGNOSTICS PN# / / FSP

Paperless Recorders & Data Acquisition Solutions SEE, STORE, SEND DATA SECURELY. Honeywell Solutions for Data Acquisition and Batch Recording

ZM400 SERIES 400 SERIES. Indicators for advanced weighing routines

Paperless recorder with TFT display, CompactFlash card and USB interfaces

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

PCPR01 Paperless Recorder

Voltage supply AC 110 to 240 V +10/-15 %, 48 to 63 Hz AC/DC 20 to 30 V, 48 to 63 Hz. Interfaces

DataVU 5 - Operating Manual

ELECTRONIC PAPERLESS RECORDERS

DCP250. Controller Programmer Presentation

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

HMI Human Machine Interface

JUMO mtron T Your System. The scalable measuring, control, and automation system

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

Food and Beverage. The Real World, True Standard

Freelance 800F packed with new features! Coming soon

Microplate Absorbance Reader Labtech LT-4500

Voltage supply AC 110 to 240 V +10/-15 %, 48 to 63 Hz AC/DC 20 to 30 V, 48 to 63 Hz. Interfaces

ScreenMaster RVG200 Paperless recorder. Measurement made easy. Secure process data at your fingertips

Paperless recorder with TFT display, Ethernet and USB interfaces

v v PMA isolated by means of opto-couplers.

Welcome to Ammonit Presentation New Data Logger Meteo-40. It will be available in early 2011

KVM Add-On RackConsoles

VPL-CH370. 5,000 lumens WUXGA 3LCD Basic Installation projector. Overview

1200 C Solid Tube Furnaces. Standard Features. Options and Upgrades. XSL C Solid Tube Furnaces 1-Zone

DMT345 and DMT346 Dewpoint Transmitters

S-Vision. The Digital Video Surveillance System of Shuttle for Home and Office Applications

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Paperless Recorders and Data Acquisition Solutions

Paperless Recorders and Data Acquisition Solutions

For synchronized press brakes. 4 or 7 axes, 2 of them synchronized axes for the beam. DNC 884S PS or DNC 887S PS

DataVU 5 - Interface Manual Modbus

DataVU 5 - Interface Manual Modbus

Honeywell Process Solutions Paperless Recorders and Data Acquisition Solutions

Software.

Presented By. NicolScales.com Contact Us

Specification for Electronic Data Recorder

2600 lumen brightness with native WXGA (1280 x 800) 16:10 widescreen screen resolution.

Digital multimeters DMG

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

CL Port PS/2-USB VGA LCD KVM Switch with Daisy-Chain Port and USB Peripheral Support

Online data sheet MEAC CEMS SOLUTIONS

Product Brochure PMA KS Multi-function Controller.

DD Diade Series Self Service Weighing Terminal. Touch screen, a thousand data items at your fingertips. DD 2050 TOUCH & GO


RTFO TOUCH ROLLING THIN FILM OVEN product bulletin

Product End-of-Life Announcement Portable Data Recorder HMG 3010

QT8716. NVR Technology IP Channels 16 (32) Recording Resolution 720p / 1080p / 3MP / 4MP Live Viewing Resolution 1080p. Live Display FPS.

t e s t i n g t o p e r f e c t i o n

KS 108 easy Compact automation unit for industrial control and process technology

PMA Prozeß- und Maschinen-Automation GmbH KS Data Monitor with Compact Flash Operation and parameterization. Manual

PUE 5 Indicator. Reliability in industrial conditions Complex support of weighing process. Functions. Features

Internal Compressor Controller

SIMATIC HMI Comfort Panels First choice for demanding HMI tasks

CL Port PS/2-USB VGA LCD KVM Switch with Daisy-Chain Port and USB Peripheral Support

VPL-DX127. 2,600 lumens XGA Desktop projector. Overview

PMA Rail Line. Product Brochure.

CPS kVA TRIFASE EN50171

JUMO SVS3000. Plant Visualization Software in the Network. Brief description. Customer benefits. Hardware requirements. Software requirements

JUMO mtron T Your System. The scalable measuring, control and automation system

UX Twin Nozzle Series. Inkjet Printer SPEED & QUALITY. Hitachi Industrial Equipment Product Brochure

VPL-CH375. 5,000 lumens WUXGA 3LCD Basic Installation projector with HDBaseT connectivity. Overview

CL5708I. 8-Port PS/2-USB VGA LCD KVM over IP Switch with Daisy-Chain Port and USB Peripheral Support

Transcription:

Introducing DataVU The New Range of Paperless Recorders from Partlow

DataVU - A New Generation in Recorders Partlow is excited to introduce DataVU, a new generation in recorders. The range includes DataVU 5, an affordable and user friendly entry level paperless recorder and DataVU 7, an advanced recorder offering a high level of functionality to its users. The recorders are ideal for use in industrial and scientific processes such as food and beverage, life science and heat treatment. DataVU 5 provides a first class 5 TFT colour display for viewing data. DataVU 5 has a TFT display for high image quality, this provides excellent levels of contrast for improved visibility and the 320 x 240 pixel screen provides sharp definition for images and information to be clearly viewed. The screen supports wide viewing angles with minimal colour distortions and loss of contrast making it ideal for use in all industrial environments. Data can be displayed and analysed through a variety of different display screens. These include: DataVU 5 The DataVU 5 paperless recorder is designed to provide a fast and easy set up through user friendly controls. Save time and money through easy and fast configuration Set up is so simple that it can be carried out on the spot via the front panel without the need for a PC. Configuration is carried out using a combination of fixed keys and menu led soft keys. Three fixed keys allow the user to easily locate and return to master control options. A legend is displayed on screen to clearly indicate the five soft keys purpose within the menu option. Numerical Display Key data information can be highlighted by using the larger numerical display. Features Graphical Display Displays data from analog channels and/or event traces. Scaling and limit markers are displayed for the channels. Event Report Important events are detailed in plain text on the report for ease of reading and to simplify interpretation (alarm messages, external texts and system messages) Historical Display Stored data can be scrolled through using the soft keys, with the ability to zoom in on a specific moment in time. DataVU 5 provides a graphical, on screen guide to the key functionality within each screen page to lead the user through the options available. The intuitive set up menu is so logical that a user can program the desired functionality without requiring an instruction manual. This not only saves time but also minimises demand on highly skilled personnel. Alternatively for those that prefer to use a PC to configure their recorder or for multiple recorders to be configured, the DataVU 5 can be set up remotely using a CompactFlash card or via communications. This is particularly time efficient when the same configuration profile needs to be set up on multiple devices. Inputs/Outputs Thermocouple RTD Voltage Current 3 or 6 channel recorder 4 binary inputs 3 relay outputs Power Supply 110-240V AC or 20-53 AC/DC DataVU 5 HMI 5 TFT Colour Screen (144mm x 144mm) 320 x 240 pixels Memory CompactFlash card 2GB for transfer of measurements and configuration of paperless recorder CPU card with main memory and measurement data memory (FLASH memory) for approx. 350,000 measurements 2 www.west-cs.com www.west-cs.com 3

DataVU 7 DataVU 7 provides advanced flexibility to meet a user s specific requirements without the need to change a process to fit the recorder. If process requirements are subject to change at a later date then the user benefits from the ease with which modifications can be made to the recorder configuration. The recorder is fully scalable - cards can be added to the recorder, facilitating future expansion. Reporting can be tailored to provide the exact information needed. The DataVU 7 allows reports to be created for daily, weekly, monthly and yearly periods. Furthermore if particular data needs to be evaluated then reports can be created using a custom date range to provide maximum flexibility. Quality problems in production can be minimized with batch logging. DataVU 7 is a robust and durable recorder that is ideally suited to challenging and harsh environments. The recorder can withstand demanding environmental conditions and meets standards for IP65 ingress protection. It can also endure abrasive substances in its surroundings as it is easy to clean, even with aggressive media. The practical control knob has been designed so that a user can set up and configure the recorder on the spot even while wearing protective gloves. Batch logging is possible for up to three batches simultaneously, independently of each other. The measured data is protected and retained even after a power interruption, preventing loss of important data. Batch entry is also possible using a barcode scanner which is effective in eliminating input errors. The Ethernet web server connection for DataVU 7 enables the simultaneous display of all analog and digital I/O on a web page. Additionally it provides the option to view up to four visualisations for one or more recorders concurrently online. To aid data being presented in a meaningful way relating to the specific process, a user can create three different customised html pages for the data to be visualised within. To tailor the presentation of data to the specific application, the user can create a personalised process image upon which relatable data can be viewed This helps to demonstrate the applicability of the data being shown. For further customisation a user can create individual comments against a report or display. Adding reference information allows greater meaning and relevancy to be attached to the data being viewed. Personalise the data presentation screens with annotated comments. Quad View F11 Full Screen X DataVU 7 delivers enhanced security to its users through its options for password protection. It ensures that the instrument can only be configured by authorised operating personnel. To further safeguard data, it is stored in an encrypted form and validated by electronic signatures, making it compliant with 21CFR PT11*. DataVU 7 provides upper and lower level alarms for analog inputs. Limits are set and an alarm is activated if the value falls outside of the set range. The recorder provides complete peace of mind as it can automatically adjust the recording speed to provide a comprehensive, clear process picture for analysis if an alarm is triggered. *Coming soon. Please contact a member of the sales team for more information. Peace of mind - DataVU 7 adjusts the recording speed if something is wrong to provide a comprehensive, clear process picture. 4 www.west-cs.com www.west-cs.com 5

Additional Modules and Accessories Features Set Up Software Power Supply Inputs/Outputs AC 100...240V +10/-15%, 18 analog inputs max. 48...63Hz 24 binary inputs/outputs max. Instrument configuration via the setup PC software can be more convenient than using the instrument keys. AC/DC 20...30V, 48...63Hz (A maximum of 3 module slots can be fitted with 6 analog inputs or 3 analog inputs and The configuration data can be created on a data medium (CompactFlash card) and read by the recorder, or transferred via one of the communication interfaces. The PC can be used to write settings to a printer. 8 binary inputs/outputs) External Inputs Interface Up to 24 analog inputs 1 x Ethernet 10/100 Mbits/sec Up to 24 binary inputs Evaluation Software 4 x USB interfaces 1 x RS232/RS485 Relay Outputs 1 x RS232 (barcode reader) 6 relays (option) Internal Channels DataVU works with PC Evaluation Software (PCA3000), a program which runs under Windows 2000/XP/Vista and Windows 7. It can be used to manage, archive, visualise and evaluate the recorder data. Data from multiple and differently configured instruments is recognized by the PC Evaluation Software and stored in an archive database for future evaluation and traceability. 1 x PROFIBUS-DP (option) DataVU 7 1 relay (standard) Display 5.5 TFT colour display 320 x 240 pixels 18 x math channels 256 colours 18 x logic channels 27 x counters / integrators Data from any analog or binary channels of a paperless recorder (even from different groups) can subsequently be combined into groups, to enable data to be easily interrogated. Since each group is displayed in a separate window, several groups can be shown simultaneously on the screen and compared. Operation Rotary knob or touchpad Measurement Data Memory 256 Mbytes Software External Memory To improve the ability to analyse and compare data it is also possible to restrict the time periods to be evaluated. Using the export filter, it is possible to export the stored data, so that they can be processed in other programs such as Excel. Set up program PC Evaluation software (PCA3000) CompactFlash card to 4GB PCC Communications software USB memory stick The PC Evaluation Software has network capability, enabling several users to obtain data from the same archive file in a network directory, independently of each other. Language Capability Math/Logic Both DataVU 5 and the DataVU 7 come complete with a languages library enabling the user to set the recorder operation to be read in their preferred language. Current available languages include: Up to six math channels are possible on DataVU 5 and up to 18 channels on DataVU 7. The option for math and logic is configurable via the setup software. It combines analog channels with one another, with counters and / or with the binary inputs. The operators available for formulae are: +, -, *, /, (, ), SQRT(), MIN(), MAX(), SIN(), COS(), TAN(), **, EXP(), ABS(), INT(), FRC(), LOG(), LN(), humidity, moving average or logics. *A maximum of six channels on DataVU 5 and 18 channels on DataVU 7 can be saved in the unit in total for both analog + math. Chinese 6 Czech English French German Greek Hungarian Italian Japanese Polish Romanian Russian www.west-cs.com www.west-cs.com 7

DataVU Features HMI Inputs and Outputs Data Comms Other Functionality Software DataVU 5 DataVU 7 Screen 5 TFT 5.5 TFT Rotary knob X Pushbutton operation with soft keys No Touchpad X Option* Number of internal channels (max.) 6 18 Number of external channels (max.) X 24 Digital inputs (max.) 4 24 Relay outputs (max.) 3 7 CompactFlash 2GB 4GB Scan rate per second (input) 250mS 125mS RS232/485 Modbus Option Ethernet Option RS232 barcode reader X USB X Profibus DP X Option Counters / Integrators (number of channels) 6 27 Maths (number of channels) 6 18 Batch (number of reports) 0 3 Web server Option Set up Evaluation Communication *Stainless Steel Option Austria T: +43 (0) 2236 691 121 China T: +86 22 8398 8098 France T: +33 (1) 77 80 90 40 Germany T: +49 (0) 561 505 1307 UK T: +44 (0) 1273 606 271 USA T: +1 800 866 6659 Email Enquiries@West-CS.com Website www.west-cs.com For more details on the complete product range from West Control Solutions please contact your local distributor or visit www.west-cs.com. BR-DV-1-ENUK-1202 Copyright West Control Solutions 2012. E & O E.