MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

Similar documents
DATA SHEET Advanced Graphical Interface, AGI 300 series

DATA SHEET Advanced Graphical Interface, AGI 100 series

DATA SHEET Advanced Graphical Interface, AGI 100 series

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET

Engine & Genset Controls Z, page 1 of 12

MIC-2 MKII, Multi-instrument DATA SHEET

with Backlight Graphic LCD Screen

DATA SHEET Advanced Graphical Interface, AGI 400 series

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

PQM - Power Quality Monitoring

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

BMS-Ethernet-Gateway COM460IP

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

QUICK START GUIDE Paralleling and Protection Unit PPU 300

MULTI-LINE 2 APPLICATION NOTES

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring

AGC 200 Advanced Gen-set Controller DATA SHEET

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

COMTRAXX COM460IP. BMS-Ethernet-Gateway

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

PPM Protection and Power Management DATA SHEET

Touch Displays, Line COP 400

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

Automatic Gen-set Controller Multi-line D

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

DomiOP ebis504. Tech-note. Highlights

QUICK START GUIDE Paralleling and Protection Unit PPU 300

HMI HUMAN MACHINE INTERFACE

DATA SHEET Paralleling and Protection Unit, PPU-3

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Delomatic 4, DM-4 Marine & Offshore DATA SHEET

Generator Protection Unit, GPU-3 DATA SHEET

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

QUICK START GUIDE Generator Protection Unit GPU 300

DATA SHEET Compact Genset Controller, CGC 200

Performance and Efficiency

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

RUDDER ANGLE INDICATION SYSTEMS

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

SPARE PART ONLY. Basic Gen-set Controller Multi-line H SW version 2.31.X or later. Data sheet. Standard functions

GC2000 Generator Controller Power Management and Protection

Basic Gen-set Controller multi-line F SW version 2.31.X or later

TYPE APPROVAL CERTIFICATE

Generator Protection Unit, GPU-3 DATA SHEET

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit

Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

Accessing the AXM-WEB at Admin level

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

ex700 Field Beautiful Power

Getting started - USW 3.x Software download from internet Software installation Device setup Data backup

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

AGC 200 Automatic Advanced Gen-set Controller DATA SHEET

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

The PowerLogic range. Gain energy insight and control

Unique Compressed Air Management System. GD Connect 12. The perfect fit

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

Tesseract. Technical Data sheet

Operator units CDPX Key features

ADDITIONAL MARINE PRODUCTS BELONGS TO MARINE CATALOG 2010

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

THE RAINBOW SCADA D-700

DEIF A/S. Description of options. Option H4 Serial comm. CAT CCM communication Multi-line 2 version 2. Description of option Functional description

PQM - Power Quality Monitoring

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Power Management System. Measuring Devices for Power Distribution

DIRIS N300/N600 Network analysers Network quality control and analysis system

Introducing DataVU. The New Range of Paperless Recorders from Partlow

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Generator Paralleling Controller, GPC-3 Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

Smart Energy & Power Quality Solutions. UMG 507 Power analyser

Advanced Graphical Interface, AGI 100

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling. 360b/01

AUTARKIC PROCESS MANAGEMENT

SA2WEB24. Central unit module. Benefits. Description

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Digital multimeters DMG

AUTOMATIC TRANSFER SWITCH CC2 & AC5 CONTROL PANELS

General introduction Part 2, chapter 11

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

Display. Resolution (pixels) Backlighting. Control elements. Keyboard. Touch operation. Installation type/mounting. Supply voltage.

the Centric 300 An advanced modular UPS up to 1800kVA/kW

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Programmable Logic Controllers. and Components for Industrial Automation. altus. evolution in automation.

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

Efficient. Innovative. Sustainable.

Option H3 Serial communication Profibus DP

Genset control and protection with safety system

UMG 511. Class A power quality analyser. Reporting Homepage

Transcription:

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

MARINE & OFFSHORE DEIF HAS A LONG AND RICH HISTORY OF PROVIDING CLASS APPROVED, RELIABLE BRIDGE INSTRUMENTATION, SWITCHBOARD EQUIPMENT AND POWER CONTROL. Conceived and designed to anticipate user needs today and in years to come, DEIF products respond to market demands for easier integration, improved user-friendliness, fuel economy and high ROI. 2

THE WORLD S PREFERRED SUPPLIER* Our market share in marine bridge instrumentation is estimated at 40 %. See www.deif.com/marine Most customers are able to install and commission our standard products working from data sheets only. In cases of doubt, DEIF s extended network of sales and application centres, distributors, customer care teams, and technical support teams is available to assist you and ensure you invest in and implement the best solution for your application. INDUSTRIES Vessels Platforms Bridge 3

Ship energy monitoring system (SEMS) Monitor and analyse energy generation and consumption 3 1 2 Switchboard equipment Modbus 1 Energy monitoring Your device 3 Power management SD card 2 Power efficiency DEIF s Ship Energy Monitoring System, SEMS, monitors real time and stores historical power data for analysis of energy generation and consumption. Use your insights to improve your power efficiency, save on fuel cost and reduce your environmental footprint. Energy monitoring solution Preprogrammed AGI 407 touch screen Up to 16 power monitoring points Data from DEIF brand controller and/or DEIF MIC-2 power instruments Modbus TCP and RS-485 supported for DEIF controllers MIC-2 MKII using RS-485 Why choose DEIF s SEMS Simple solution for energy monitoring Plug & play Pre-programmed graphical views for local monitoring of energy consumption on AGI display. Free technical support for SEMS SD card for historical data storage Data available on Modbus Relevant SEMS components MIC-2 MKII KBU AGI 407 Relevant controllers PPM-3 PPU-3 GPU-3 PPM 300 PPU 300 GPU 300 4

Advanced graphical interface Multi-touch widget HMI for system monitoring & control AGI 400 features TFT colour display, LED backlight 500cd/m 2 24bit colour resolution Capacitive touch screen, supporting multi-touch widgets 3 Ethernet ports with individual MAC address with bridge option 2 USB 2.0 host ports A comprehensive HMI solution, DEIF s AGI 400 series connects to all DEIF Multi-line controllers, as well as third party electronics, via standard defined communication protocols, featuring functionalities which eliminate the need for other instruments, thus saving you both space and wiring. The AGI 400 series is intended for visualisation and active control in multiple applications managed on board maritime vessels or platforms, where it provides full graphical overviews and user-friendly touch screen control with a quality display that is easily readable even at sharp angles. AGI 400 supports multiple users levels, and LAN clients, ensuring user control in several levels. Application examples Power management systems control and supervision: one point management, control and supervision of multiple gensets and bus tie breakers. Alarm handling and monitoring: view historical alarm data and accept active alarms. Graphical interface mechanical and electrical systems: system overviews for mechanical and electrical equipment. Trend measured values to monitor operation performance or when carrying out fault-finding procedures. RS-232, RS-422 and RS-485 serial communication SD card slot Slim design (mounting depth less than 60 mm) Multiple protocols Data transfer between protocols RTC with NTP synchronisation LED back light off with custom timeout TrueType fonts SVG images Multi-language Backlight dimming 0-100% Backlight time out Backlight service time: 50,000 h or more Multi-touch screen Operating temperature: -20 C to +60 C (vertical installation) Variant overview AGI 407 AGI 410 AGI 415 AGI 421 5

Multi-instrument for panel Access monitoring data remotely via the internet MIC-2 MKII features Measures voltage, current/active/reactive and apparent power, frequency, energy kwh/kvarh, PF, THD, demand For all 2- and 3-phase AC network topologies Suitable for power quality analysis Measures individual harmonics from 2 nd to 63 rd Min./max. statistic with time stamp Versatile and intuitive, DEIF s multi-instrument MIC-2 MKII is perfectly suited for monitoring and analysis of all types of power systems. The MIC-2 MKII helps you optimise your energy system. Capable of logging all applications from single low voltage to multiple high voltage applications, the sturdy unit offers a complete overview of your SCADA system. A microprocessor-based measuring unit for most electrical quantities on 2-phase or 3-phase electric energy distribution networks, readings are displayed on a large built-in LCD screen. Fitted with the ethernet TCP/IP module, the unit offers direct access to Modbus data and is easy to access remotely via standard browsers. Customised alarm settings with 16 different parameters RS-485 Modbus communication Large LCD screen with white backlight Optional communication modules Ethernet (Modbus TCP, HTTP, SMTP) Profibus DP Optional I/O modules Relay Analogue I/O Digital I/O Free utility software with data logging Type approvals from all major classification societies KWh counter reset and change of settings can be password-protected, and using DEIF s programmable utility software it is a simple and fast job to configure and adapt the unit to fit most applications. 6

Vita: The first of 38 TORM Vita is the first of a fleet of 38 vessels to have DEIF SEMS installed Complete SEMS for 3 diesel generators DEIF delivered complete SEMS solution with an AGI touch screen logging data and displaying all relevant data delivered by 3 DEIF multi-instruments. Installation & support DEIF SEMS will be provided with a detailed installation and operation guide. Contact DEIF Support at marinesupport@deif.com for further assistance. Parallel running hours reduced by approximately 10 %. Display examples 7

DEIF A/S Frisenborgvej 33, 7800 Skive, Denmark Tel. +45 9614 9614 LEARN MORE AT WWW.DEIF.COM/MARINE-OFFSHORE