AXL E IOL AO1 U M12 R

Similar documents
This data sheet is only valid in association with the IL SYS INST UM E user manual.

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

8 24 V DC, 8 24 V DC,

AXL F AO4 1H. Axioline F analog output module, 4 outputs. Data sheet. 1 Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

IB IL AO 2/SF... Inline terminal with two analog outputs. AUTOMATION Data sheet 6655_en_06. 1 Description

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

GFK-2415A March Type of sensor connection

IB IL 24 DI 16 IB IL 24 DI 16-PAC

IBS IL 24 BK RB-T-2MBD

AXL E EC DI16 M12 6P. Axioline E EtherCAT device, plastic housing, 16 inputs, 24 V DC, M12 fast connection technology. Data sheet.

PHOENIX CONTACT - 10/2006

AXL E PB DIO16 M12 6P

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2008

ILB BT ADIO 2/2/16/16

IB IL 24/48 DOR 2/W-XC-PAC

TRIO-DIODE/12-24DC/2X10/1X20

AXL E PN DI8 DO8 M12 6P

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

FL MC 2000E (SM40) LC

PHOENIX CONTACT - 07/2006

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

Installation Instructions Temperature transmitter TAA /00 06/2011

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

QUINT-BUFFER/24DC/24DC/40

Rexroth Inline terminal with one analog output

VersaMax IP I/O Module

AXL BK PN (-ME) Axioline bus coupler for PROFINET IO. Data sheet. 1 Description

VersaMax IP Input Module

IBS IL 24 RB-LK-2MBD:

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PHOENIX CONTACT - 10/2009

PHOENIX CONTACT Features

IB IL IB IL PAC

ILC 200 IB ILC 200 IB-PAC

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

MINI-PS AC/10-15DC/8

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

VersaPoint I/O Module

MINI MCR-SL-PT100-UI(-SP)(-NC)

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

This data sheet is only valid in association with the IL SYS INST UM E user manual.

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

VERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

AXL F BK PN. Axioline F bus coupler for PROFINET. Data sheet. 1 Description

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

IBS PCI SC/I-T. Controller Board for PC Systems With PCI Bus. Data Sheet 6039B

IB IL RS 232 IB IL RS 232-PAC

AO561 Analog Output Module

STEP-PS/1AC/24DC/1.75

IB IL EX-IS AIO 4/EF-PAC

PSR UC/ESAM4/3X1/1X2/B

DI572 Digital Input Module

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Temperature modules. 8 inputs for connection of thermocouple sensors S20-AI-8-UTH

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

IB IL EX-IS TEMP 4 RTD/TC-PAC

AI561 Analog Input Module

PSI-MODEM-SHDSL/SERIAL

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Valueline Industrial PC

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

RAD-PT100-4-IFS. I/O extension module, 4 temperature inputs (Pt 100) Data sheet. 1 Description

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

MINI MCR-SL-PT100-UI-200

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

PB IL 24 BK DIO 16/16

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 01/2007

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

DI561 Digital Input Module

PSR DC/ESP4/2X1/1X2

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I(-SP)(-NC)

TU531, TU532 Terminal Unit

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-MUX-V8-FLK 16

TM3AI4 module TM3-4 analog inputs

BNI IOL K023 BNI IOL K023. User s Guide

PHOENIX CONTACT - 04/2008

TF501, TF521 Terminal Bases

PHOENIX CONTACT - 11/2008

BNI IOL K023 BNI IOL K023. User s Guide

DC562, digital input/output module,

PHOENIX CONTACT - 05/2007

Transcription:

Axioline E IO-Link/analog converter for connecting an analog actuator, 0 V... 10 V, rectangular version Data sheet 8588_en_03 PHOENIX CONTACT 2014-09-22 1 Description The IO-Link/analog converter is an IO-Link slave that converts the IO-Link protocol into analog signals. It therefore offers the option of transmitting signals to analog actuators via an IO-Link master. Features Rectangular version 1 IO-Link interface 1 analog output Connection of the actuator in 3-wire technology Voltage range: 0 V... 10 V IO-Link and actuator connections via M12 connectors FE connection for local connection to functional earth ground Supply of the module electronics and the actuator via the IO-Link interface of the IO-Link master Diagnostic indicator Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products.

2 Table of contents 1 Description... 1 2 Table of contents... 2 3 Ordering data... 3 4 Technical data... 3 5 Additional tables... 5 6 Internal circuit diagram... 5 7 Pin assignment... 6 7.1 Connections on the device... 6 7.2 Pin assignment of the IO-Link interface... 6 7.3 Pin assignment of the analog output... 6 8 Connection notes... 6 9 Connection example... 6 10 Assembly... 7 11 Local status indicator... 7 12 Process data... 8 12.1 IN process data... 8 12.2 OUT process data... 9 12.3 Parameterization via OUT process data... 9 12.4 Example... 9 13 Significant values in various formats... 10 13.1 IB IL format... 10 13.2 S7-compatible format... 10 14 IO-Link objects... 11 14.1 Overview of the objects... 11 14.2 Parameterization (80 hex : ParaWord)... 12 8588_en_03 PHOENIX CONTACT 2

3 Ordering data Description Type Order No. Pcs. / Pkt. Axioline E-IO-Link/analog converter for connecting an analog actuator, 0 V... 10 V, M12 fast connection technology, rectangular version 4 Technical data AXL E IOL AO1 U M12 R 2700278 1 Dimensions (nominal sizes in mm) 66,5 50 16,6 41 29 28 Width Height Depth 16.6 mm 42 mm 66.5 mm General data Weight 34 g Ambient temperature (operation) -25 C... 60 C Ambient temperature (storage/transport) -25 C... 85 C Permissible humidity (operation) 5 %... 95 % Permissible humidity (storage/transport) 5 %... 95 % Air pressure (operation) 70 kpa... 106 kpa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kpa... 106 kpa (up to 3000 m above sea level) Degree of protection IP65/67 Protection class III, IEC 61140, EN 61140, VDE 0140-1 Pollution degree 2 IO-Link Specification V1.1.1 Protection against polarity reversal Yes Transmission speed 230,4 kbit/s (COM3) Frame type 1 Cycle Time min. 2 ms Process data update 2 ms Amount of process data 16 Bit (Input data), 16 Bit (Output data) IO-Link ports Number of ports 1 Connection method M12 connector, A-coded 8588_en_03 PHOENIX CONTACT 3

IO-Link port supply Typical current consumption Current consumption Protection against polarity reversal Short-circuit protection Overload protection I/O supply voltage Sensor supply voltage Analog output Number of outputs Connection method Connection method Voltage output signal Voltage output signal Load/output load voltage output D/A resolution Data formats Precision Permissible cable length 16.5 ma ±15% (at 24 V DC) max. 135 ma Yes Yes Yes 24 V DC This supply voltage is provided via the IO-Link interface of the IO-Link master. 24 V DC (max. 100 ma) This supply voltage is provided via the I/O supply voltage. 1 (voltage) M12 connector, A-coded 3-conductor 0 V... 10 V 0 V... 10 V min. 2 kω 12 bit IB IL, S7-compatible < 0.25 % (of output range final value in the nominal range) max. 30 m (Shielded cable) Error messages to the higher level control or computer system Short circuit Message in the diagnostic code (in the IB IL format) Configuration invalid Message in the diagnostic code (in the IB IL format) Module faulty Message in the diagnostic code (in the IB IL format) Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Continuous shock according to EN 60068-2-27/IEC 60068-2-27 Operation: 2g Storage/transport: 5g Operation: 30g, 11 ms, three shocks in each space direction Storage/transport: 50g, 11 ms, three shocks in each space direction 10g, 16 ms, 1000 shocks, in all space directions Approvals For the latest approvals, please visit phoenixcontact.net/products. 8588_en_03 PHOENIX CONTACT 4

5 Additional tables 6 Internal circuit diagram The data is valid for nominal operation (supply voltage = 24 V) in the default configuration (measurement range 0 V... 10 V). Tolerance and temperature response at T A = -25 C to +60 C Drift Typical Maximum IO-Link L+ C/Q L- Protection IO-Link IC µc Protection 1 4 3 FE Analog ±25 ppm/k ±75 ppm/k FE The tolerance values refer to the measuring range final value. Tolerances influenced by electromagnetic interference Standard Electromagnetic fields EN 61000-4-3/ IEC 61000-4-3 Fast transients (burst) EN 61000-4-4/ IEC 61000-4-4 Conducted interference EN 61000-4-6/ IEC 61000-4-6 Type of electromagnetic interference Tolerance < ±1.0% A < ±1.0% A < ±1.0% A Criterion Figure 1 Key: Protection IO-Link IC µc Internal wiring of connections Protective circuit IO-Link circuit Microprocessor Digital/analog converter 8588_en_03 PHOENIX CONTACT 5

7 Pin assignment 7.1 Connections on the device 7.3 Pin assignment of the analog output 1 2 5 1 4 3 3 2 Figure 4 Pin assignment of the analog output (M12, A-coded, socket) Figure 2 Connections on the converter No. Connection 1 IO-Link interface (indicated by IO-Link symbol) 2 Fixing options; options for connection to functional earth ground 3 Analog output 7.2 Pin assignment of the IO-Link interface 2 1 Pin Assignment 1 +24 V, 100 ma 2 Not used 3 GND 4 Voltage output 0 V... 10 V 5 Not used 8 Connection notes Always connect the analog actuators using shielded twisted-pair cables. 9 Connection example 3 Figure 3 4 Pin assignment of the I/O link interface (M12 A-coded, pin) 2 3 1 4 L- C/Q L+ Pin Signal Meaning 1 L+ +24 V supply voltage; from IO-Link master 2 - Not used 3 L- GND, reference potential for L+ 4 C/Q IO-Link data transmission channel Figure 5 1 4 +24 V 0...10 V 5 2 3 Connection example 8588_en_03 PHOENIX CONTACT 6

10 Assembly 11 Local status indicator COM Figure 6 Connection of an actuator to an IO-Link master via the converter Figure 7 Local status indicator Connect the IO-Link interface of the converter to an IO- Link port of the higher-level IO-Link master using a standardized 3-pos. cable. Connect the analog actuator directly to the analog converter output or using a shielded 4-pos. cable. Fasten each connection using the M12 connectors. In environments with high levels of interference, in particular, Phoenix Contact recommends connecting the converter to an appropriate functional earth ground point using an M4 screw. Color Meaning State Description Green Status of IO-Link device Designation COM ON Flashing OFF Supply voltage OK Supply voltage OK, SDCI communication active No supply voltage, no communication 8588_en_03 PHOENIX CONTACT 7

12 Process data The device occupies one word of IN process data and one word of OUT process data. 12.1 IN process data The following data is transmitted in the input process data: During normal error-free operation, the output value is mirrored in the input process data for each channel. If an error occurs, the diagnostic message is mirrored in the input process data for each channel. The diagnostics message is deleted as soon as the error is eliminated. Diagnostic messages in IB IL format Code (hex) Cause 8001 Overrange 8003 Short-circuit 8040 Device faulty 8080 Underrange Diagnostic messages in S7-compatible format Code (hex) Cause 7FFF Overrange 8000 Short-circuit/underrange 12.2 OUT process data The output values are depicted in IB IL or S7-compatible format. For both formats the output value is represented in bits 14 to 3. Bit 15 is available as a sign bit. Bits 2 to 0 are not relevant for the output value. 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 V Analog value x x x V Sign bit (= 0, not relevant) x Not relevant for the output value (must be 0) Parameterization In addition, the device can be parameterized via the process data output word. The following configurations are possible: Selection of formats for representing measured values Establishing substitute value behavior 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Configuration Reserved Substitute value behavior in the event that IO-Link communication is aborted Format Reserved For the exact meaning of the individual bits, please refer to Parameterization (80 hex : ParaWord). Output values in the range from 8000... BFFF are interpreted as parameter. 8588_en_03 PHOENIX CONTACT 8

12.3 Parameterization via OUT process data Reparameterization can be carried out via the output process data, however this is not saved permanently on the device. Please operate the reparameterization only by the startup of the device! The following sequence applies regardless of the format ( IB IL or S7-compatible): The master interrupts the transmission of current process data and sends parameter data (OutputProcess- Data with bit 15 = 1) In order to start configuration, bit 15 of the output word must be set to 1. If bit 15 = 0, the default configuration is active. The device interrupts the transmission of current process data and responds with the following diagnostic code in the process data: Code (hex) Cause 8800 Parameter OK 8801 Parameter ERROR If the diagnostic code is OK, the parameter data is accepted immediately. The master can end parameterization (OutputProcessData with bit 15 = 0). The device returns to normal operation with cyclic process data transmission. In the event of the ERROR diagnostic code, the master can abort parameterization without modified parameter data (OutputProcessData with bit 15 = 0) or transmit the modified parameterization (return to step 1). 12.4 Example The example applies to the following changes: Selection of format S7-compatible (Default) to IB IL For "hold last value" 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Configuration Reserved Substitute value behavior in the event that IO-Link communication is aborted Format Reserved 1 Reserved 1 0 1 0 Reserved 8588_en_03 PHOENIX CONTACT 9

13 Significant values in various formats 13.1 IB IL format Resolution: 1 bit (0000 -> 0008) accords 2.67 V. Output data Range 0 V... 10 V hex dec V > 7F00 > 32512 Overrange 10.837 7F00 32512 Overdrive range (End) 10.837 7538 30008 Overdrive range (Start) 10.00267 7530 30000 Nominal range (End) 10.0 3A98 15000 Nominal range 5.0 0008 8 Nominal range 0.00267 0000 0 Nominal range (Start) 0 < 0000 < 0 Underrange 0 This device cannot display voltage < 20 mv. Values > 0020 hex are supported. If overrange, input data 8001 hex is indicated. If underrange, input data 8080 hex is indicated. If short-circuit occurs, 0 V is issued and input data 8003 hex is indicated. 13.2 S7-compatible format Resolution: 1 bit (0000 -> 0008) accords 2.89 mv. Output data Range 0 V... 10 V hex dec V > 7EF8 > 32504 Overrange 0 7EF8 32504 Overdrive range (End) 11.756 6C08 27656 Overdrive range (Start) 10.00289 6C00 27648 Nominal range (End) 10.0 3600 13824 Nominal range 5.0 0008 8 Nominal range 0.00289 0000 0 Nominal range (Start) 0 < 0000 < 0 Underdrive range 0 The device cannot display voltage < 20 mv. Values > 0018 hex are supported. If overrange, input data 7FFF hex is indicated. If underrange, input data 8000 hex is indicated. If short-circuit occurs, 0 V is issued and input data 8000 hex is indicated. 8588_en_03 PHOENIX CONTACT 10

14 IO-Link objects 14.1 Overview of the objects Index (hex) Object name Length in Access Meaning Contents DPP ISDU bytes Identification 07 Vendor ID 2 R Manufacturer identification 00 hex 08 B0 hex 09 Device ID 3 R Device ID 01 hex 0A 00 hex 0B 28 hex 10 VendorName Max. 64 R Manufacturer name Phoenix Contact 11 VendorText Max. 64 R Notes www.phoenixcontact.com 12 ProductName Max. 64 R Product designation AXL E IOL AO1 U M12 R 13 Product ID Max. 64 R Order No. 2700278 14 ProductText Max. 64 R Product text IO-Link/analog converter voltage output rectangular 15 Serial number Max. 16 R Serial number Stored in the production process. 16 HardwareVersion Max. 64 R Hardware version E.g., 01 17 FirmwareVersion Max. 64 R Firmware version E.g., 001 Diagnostics 20 Error count 2 R Errors since power up Number of errors 29 OutputProcessData 2 R Output process data Last current data Parameter 80 ParaWord 2 R/W Parameterization 0000 hex Abbreviation R W Meaning Read Write 8588_en_03 PHOENIX CONTACT 11

14.2 Parameterization (80 hex : ParaWord) Parameterize the device using this object. In the case of valid parameters, the parameterization is permanently stored on the device. After a reset, the device operates with the last permanently stored data. Upon delivery, the device operates with the default data (default settings). Saving data to the device leads to a communication failure of around 30 ms. 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Reserved Substitute value behavior in the event that IO-Link communication is aborted Format Reserved In the following tables the values in bold are default settings. Format Code (bin) Meaning 00 S7-compatible 10 IB IL Other Reserved Substitute value behavior in the event that IO-Link communication is aborted Code (bin) Meaning 00 Output of zero value (0 V) at output 01 Output of final value (10 V) at output 10 Hold last value 11 Reserved Other Reserved 8588_en_03 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 12 phoenixcontact.com