Switching Power Supply S82G. Ordering Information. Dependable Power Supply for Demanding Industrial Applications

Similar documents
Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Switching Power Supply

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Voltage Current Front-mounting bracket

Switching Power Supply

S8VE (60/90/120/180/240-W Models)

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

S82J (10/25/50/100/150/300/600-W Models) CSM_S82J_DS_E_3_1

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

masterelectronics.com onlinecomponents.com

S82S (3/7.5-W Models)

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

Switch Mode Power Supply S8VT 120/240/480/960 W Models

H7ER H7ER-V H7ER-V1 H7ER-V2 H7ER-V3

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend


Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

Inductive Proximity Sensor

Switch Mode Power Supply

Switch Mode Power Supply

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

E2EC-CR8D2 5.4 mm dia. 1.5 mm (0.06 in) NO E2EC-C1R5D1 NC. E2EC-C1R5D2 8mmdia. 3 mm (0.12 in) NO E2EC-C3D1 NC

Model Number Structure

Switch Mode Power Supply

SYSMAC Remote Transistor Module

Model Number Structure

Chip Immune Inductive Prox E2EZ

Inductive Proximity Sensor

Solid-state Timer H3YN

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection

Snap Action Switch. General- Low force 25 g D2F-FL D2F-FL-T D2F-FL-D D2F-FL-A D2F-FL-A1

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Model Number Structure

Temperature Controller E5C4

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Miniature Inductive Prox TL-W

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

Link Master Adapter. Ordering Information. Connect High-Density I/O PLC Modules to 16-Point B7A Modules

Transistor I/O Link Modules

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

Solid-State Counter/Timer

Standards VDE: EN60950; UL1950; C-UL: CSA C22.2 No.234; IEC950; VDE0805

Self-Powered Counters H7EC

2. Actuator B: Ball type P: Pin type F: Flat type

1. Capacity 2. Output Voltage 3. Structure 4. Bus Line Connectors 025: 25 W 030: 30 W 060: 60 W. None: Screw terminals F: Connector terminals

Plastic Cylindrical Inductive Prox

Model Number Structure

Special-purpose Basic Switch

SPECIFICATIONS. Input Output Agency Approvals 0 ~ 62.5A. toll-free (603)

D2SW-3L1HS D2SW-01L1HS

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Mini Photoelectric Sensor

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Switch Mode Power Supply. New Product

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

Thread length (overall length) material

I/O delay. (0.32 in ±0.06 in)

Switch Mode Power Supply. New Product

Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Technical Guide for Power Supplies

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

Chemical Resistant Inductive Prox

120/240VAC 300 W 5 VDC 60 A S82D VDC 27 A S82D W 5 VDC 120 A S82D VDC 53 A S82D-6012

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB

PFE-S SERIES Single Output AC-DC Power Module UL / EN60950 Low Voltage Directive CSA C22.2 No Features Model naming method

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

LED Driver Linear / area fixed output

Cylindrical Proximity Sensor

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Natural cooling, When output exceed 80% LOAD, a 18 CFM(min) DC fan is required

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

General. Environmental. EMC & Safety

120 WATT FLEX ATX TYPE WITH ACTIVE PFC

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

Z-15GW2277 Z-15GW2277-B

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

PS 2500 SYSTEM IN-BUILT ALARM MONITORING FLEXIBLE ON-LINE LIVE REPLACEMENT HIGH EFFICIENCY HIGH OUTPUT FROM A SMALL PACKAGE

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Transcription:

Switching Power Supply Dependable Power Supply for Demanding Industrial Applications Power rating range from 30 to 0 W Wide range of output voltage: 5, 12,, and 24 V Field-selectable input voltage 120 or 240 VAC Equipped with overvoltage and overload protection Remote sensing and remote control functions (some models) 3-Year warranty Ordering Information SWITCHIG POWER SUPPIES Rated input voltage Power ratings Output voltage Output current Part number 120/240 VAC selectable 30W 5V 6A -0305 12 V 2.5 A -0312 V 2A -03 24 V 1.3 A -0324 60 W 5V 12 A -0605 12 V 5A -0612 V 4A -06 24 V 2.5 A -0624 0 W 5V 20 A -05 12 V 9A -12 V 7.2 A - 24 V 4.6 A -24 0 W 5V 30 A -05 12 V 13.5 A -12 V.8 A - 24 V 7A -24 For mounting brackets and other accessories refer to the Accessories Section on the next page. MODE UMBER EGED - 1 2 1. Power ratings 03: 30 W 06: 60 W : 0W : 0 W 2. Output voltage 05: 5 V 12: 12 V : V 24: 24 V

ACCESSORIES (ORDER SEPARATEY) Description Applicable power supply Part number Bottom-mounting bracket -03 S82Y-G03B -06 S82Y-G06B - S82Y-CM1B - S82Y-CB Side-mounting bracket - S82Y-CM1S Specifications Power ratings 30 W 60 W 0 W 0 W Efficiency (typ.) Input 71% (at 5 V ) to 74% (at 24 V) 75% (at 5 V) to 82% (at 24 V) Operating voltage AC 85 to 132 VAC/170 to 264 VAC (selectable) Frequency Current at rated Input voltage and rated output voltage/current eakage current at rated input volt- age and output voltage current Inrush current at rated input volt- age and rated output voltage/ current oise filter Output DC o 47 to 450 Hz At 0-V input 0.95 A max. 1.7 A max. 2.7 A max. 4Amax. At 200-V input 0.6 A max. 0.9 A max. 1.4 A max. 2.1 A max. At 0-V input At 200-V input At 0-V input At 200-V input 0.5 ma max. 1 ma max. A max. 30 A max. Provided Voltage adjustment Ripple and noise Regulation, line Regulation, load Temperature coefficient Rise time Hold up time ±% (adjustable by adjuster) 5 V: 50 mv p-p max., 12 V: 120 mv p-p max., V: 0 mv p-p max., 24 V: 240 mv p-p max. 0.5% max. (at 85 to 132/170 to 264 V input, 0% load) 0.8% max. (at rated input, to 0% load) 0.03%/ C max. ( at rated input/output) 300 ms max. (90% output voltage rise at rated input voltage and rated output voltage/current) 20 ms min. (90% output voltage rise at rated input voltage and rated output voltage/current) Additional functions Overload protection 5% of rated output current typ., trailing, automatic reset Overvoltage protection 120% of rated output voltage typ., shut off, reset by reapplication of input Remote sensing Yes Remote control o Yes (This table continues on the next page.)

Specifications Table -- continued from previous page Power ratings 30 W 60 W 0 W 0 W Characteristics Operating temperature Storage temperature See Derating Curve in Engineering Data -20 to 85 C (-4 to 185 F) Humidity 30 to 90% (storage humidity: 20 to 95%) Dielectric strength Insulation resistance 2200 VAC, 50/60 Hz, for 1 minute (between input terminals and output terminals/housing) 500 VDC for 1 minute (between output terminals and input terminals/housing) 0 MΩ min. (between output terminals and input terminals/housing) Vibration to 55 Hz, 0.75 mm double amplitude (approx. 4.5 G) in 3 directions, respectively for 2 hours Shock Output indicator Electro Magnetic Interference Mean Time Between Failures 294 m/s 2 294 m/s 2 (30 G) in 6 directions, respectively 3 times Red ED FCC Class B 0,000 hours min. Approved standards U (E5544), CSA (R63986), VDE 0 Weight 750 g max. 850 g max. 1,0 g max. 2,000 g max. A surge absorber is provided for the input. To test the dielectric strength and insulation resistance of the power supply, remove the short bar attached across the FG and ACG terminals. Engineering Data DERATIG CURVE The derating curve differs depending on the mounting position of the Power Supply. The curve shown here was obtained with the Power Supply mounted in the standard position. Forced air cooling OVEROAD PROTECTIO The power supply is provided with an overload protection function that protects the load and the power supply from possible damages by overcurrent. When the output current rises above a set value (5 to 135% of the rated output current), the protection function is effected, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. oad (%) atural air cooling Output voltage (V) Rated output voltage Ambient Temperature (C) Mounting Position - Standard Installation Output current (%)

OVERVOTAGE PROTECTIO The power supply is also provided with an overvoltage protection function that protects the load from possible damage by overvoltage. When the output voltage of the power supply rises to about 120% of the rated value, this function is effected and the output voltage is shut off. To clear the protection function, turn off the input voltage once, wait for at least 20 seconds, and then turn on the input voltage. The output voltage can be varied by the V. ADJ adjuster of the front panel. When it is set to a value % higher than the rated value, the overvoltage protection function may be effected. Output voltage (V) Approx. 20% % Rated output voltage --% Variable Overvoltage IRUSH CURRET, RISE TIME, HOD TIME Input O Input OFF AC input voltage Inrush current on input application AC input current Output voltage Rise time 300 ms max Hold time 20 ms min

omenclature -03-06 - - VADJ DC O +S 24 VDC, 13 A -V -S VADJ DC O +S 24 VDC, 7 A -V FG -V -S IPUT AC1 C +RC C -RC FG 1. DC Output Terminals: Connect load wiring. 2. Input Terminals: Connect input wiring. 3. Input Voltage Selector Terminals: Switch the input voltage by connecting or removing the short bar. (short ed: 0 to 120 V; open: 200 to 240 V). 4. V. ADJ Adjuster: Use to adjust the output voltage. 5. Output ED Indicator: ights when DC current is being output. 6. Remote Sensing Terminals: Correct the voltage drop in the load lines. Shorted for normal operation. 7. Remote Control Terminals: Turn the output O or OFF, by using an external signal, with the input voltage applied. 8. ACG Terminal: Input filter neutral terminal, which is usually short-ed to the FG terminal. 9. FG Terminal: Short-ed to the housing and is connected to a ground line.. C Terminal: Vacant terminals. 11. Short Bars: Operation REMOTE SESIG FUCTIO This function corrects a voltage drop in the load lines. When using the remote sensing function, remove the short bars from the remote sensing terminals as shown in the following diagram. REMOTE COTRO FUCTIO This function allows the output voltage to be turned on and off with an external signal (as long as the input voltage is being applied). When using the remote control function, remove the short bar (as set by the factory) from the remote control terminals and connect a switch or transistor, across those terminals, as shown in the diagram below Remote sensing connection (2-wire shielded cable) V ADJ DC O Remove the short bars Remove the short bar oad oad lines 1. When a high voltage drops occur on the load lines, the output voltage across the power terminals rises by the amount of the dropped voltage, causing the overvoltage protection function to be effected. To prevent this, use as thick a wire as possible. 2. When the +S and terminals, or -V and -S terminals are opened with the short bar removed, the overvoltage protection function is effected and, as a result, no output voltage is produced. Switch or Transistor O OFF Output voltage O OFF

BOCK DIAGRAM -03 ACG FG IPUT 120/240 V Selector Fuse (2 A) oise filter Inrush current protection Rectifier/ Rectifier DC OUTPUT -- V +S Remote sensing -- S Photocoupler Rectifier Overvoltage Overload Photothyristor -06 - ACG FG IPUT 120/240 V Selector Fuse (60 W 3A 0 W 5 A) oise filter Inrush current protection Rectifier/ Rectifier DC OUTPUT -- V +S Remote sensing -- S Control Photocoupler Overvoltage Overload Photothyristor

- ACG FG IPUT 120/240 V Selector Fuse 5A oise filter Inrush current protection Rectifier/ Rectifier Overload DC OUTPUT -- V Overvoltage +S Remote sensing Control -- S Auxiliary power Drive +R.C. Remote control terminals -- R.C. SWITCHIG THE IPUT VOTAGE BETWEE 0 TO 120 V AD 200 TO 240 V Select 120 and 240 V input voltage by shorting or opening the input voltage selector terminals, as shown in the diagram below. (Factory set to 240 V operation.) GEERATIG OUTPUT VOTAGES (±) power supplies may be connected to provide (± ) output voltages since the power supply produces floating output. See diagram below. 0 to 120 VAC Use the short bar to short the input voltage selector terminals. Input Input P/S 1 -V OAD Input P/S 2 -V OAD Remove the short bar. 200 to 240 VAC

Dimensions Unit: mm (inch) SWITCHIG POWER SUPPIES -03 45 (1.77) 170 (6.69) (Bottom mounting) (A) When three holes are made 1 (4.33) 125 (4.92) Three 4 dia. holes (B) When four holes are made M4 terminal screw Seven M3 mounting holes* 20 20 140 (5.51) Four 4 dia. holes 22.5 125 MAX 25 140-06 50 (1.97) 190 (7.48) (Bottom mounting) (A). When three holes are made 1 (4.33) 140 (5.51) Three 4 dia. holes (B) When four holes are made M4 terminal screw Seven M3 mounting holes* 25 25 (6.30) MAX 25 140 Four 4 dia. holes

- 60 (2.36) 200 (7.87) Bottom mounting 1 (4.33) (6.30) 35 Four 5 dia. holes M4 terminal screw Four M4 mounting holes* 35 MAX 25 20-0 (3.94) Four M4 mounting holes 230 (9.06) Bottom mounting 90 120 (4.72) 90 (6.30) Four 5 dia. holes M4 terminal screw 20 Four M4 mounting holes Side mounting 70 70 Four 5 dia. holes MAX 25 20 ength of screw: 6 mm (excluding thickness of mounting plate) MOUTIG BRACKET (SOD SEPARATEY) Bottom mounting S82Y-G03B (30 W) Three 4.5 dia. holes Three M4 25 183 (7.20) 25 45 6 12.5 183 195 (7.68) 12.5 12.5 To attach the mounting bracket to the power supply, use M3 x 6 flat head screws.

Unit: mm (inch) S82Y-G06B (60 W) Three 4.5 dia. holes Three M4 25 30 50 202 (7.95) 214 (8.43) 6 202 To attach the mounting bracket to the power supply, use M3 x 6 flat head screws. S82Y-CM1B (0W) Three 4.5 dia. holes Mounting Holes Three M4 32.5 40 65 232 (9.13) 244 (9.61) 6 12.5 232 20 20 To attach the mounting bracket to the power supply, use M4 x 8 flat head screws. S82Y-CB (0W) Mounting Holes Four 4.5 dia. holes Four M4 6 40 30 0 262 262 (.31) 274 (.79) 6 40 To attach the mounting bracket to the power supply, use M4 x 8 flat head screws. Side mounting S82Y-CM1S (0W) Four 4.5 dia. holes Mounting Holes Four M4 132 144 132 (6.30) 30 6 220 (8.66) To attach the mounting bracket to the power supply, use M4 x 8 flat head screws.

Precautions MOUTIG Providing adequate cooling when installing the power supply will extend its long-term reliability. Install the unit in a location with adequate air flow (as shown in the diagram included here) because the power supply is cooled by natural air flowing around it. Install the power supply on a metal plate. Use forced-air cooling. When installing two or more power supplies side-by-side, allow at least 20 mm (0.79 in) spacing between them, as shown in the diagram provided here. 20 mm min. Air Metal plate OTE: DIMESIOS SHOW ARE I MIIMETERS. To convert millimeters to inches divide by 25.4. OMRO EECTROICS, IC. OneEastCommerceDrive Schaumburg, I 60173 1-800-55-OMRO OMRO CAADA, IC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Cat. o. GC PS5 7/99 Specifications subject to change without notice. Printed in U.S.A.