FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

Similar documents
FVT/FVR10D1E(M,S)[M] 10-BIT DIGITALLY ENCODED VIDEO TRANSMITTER WITH 1 BI-DIRECTIONAL DATA CHANNEL AND 10/100MB ETHERNET

FVT/FVR110(M,S)1[/M] 10-BIT DIGITAL VIDEO WITH ONE BI-DIRECTIONAL DATA CHANNEL INSTALLATION AND OPERATION MANUAL

CNMC[2]SFP[POE][/M] Series

CL(T,R)VE(1,2)COAX[POE][/M]

CWFE(1,2)COAX[M] INSTALLATION AND OPERATION MANUAL

CNFE2MCPOE[/M] 10/100 MBPS 2 PORT MEDIA CONVERTER WITH POWER OVER ETHERNET INSTALLATION AND OPERATION MANUAL

CNFE1CL1MC(-M) FAST ETHERNET OVER VDSL (EoVDSL) INSTALLATION AND OPERATION MANUAL

CNFE1CL1MC(-M) Fast Ethernet over VDSL (EoVDSL) INSTALLATION AND OPERATION MANUAL

FVT/FVR1031(M)(S)1. 10-bit digital video with bi-directional data (RS232, 422 and RS485 2 & 4 Wire) INSTALLATION AND OPERATION MANUAL

FVT/FVR(X)MI[/M] INSTALLATION AND OPERATION MANUAL

CNFE200(X)[POE](M,S)(1,2)[HO][/M]

CLFE4+1SMS[POE](C,U) Series 10/100 4TX+1EX ETHERNET SELF-MANAGED SWITCH WITH POWER OVER ETHERNET (POE+)

CLFE(X)EO(C,U) Series ETHERNET OVER COPPER EXTENDER WITH PASS-THROUGH POE TO 15 WATTS

FDW1000(M,S) OPTICAL WIEGAND, MAGSTRIPE & F/2F DATA EXTENDER INSTALLATION AND OPERATION MANUAL

CNGE2+2SMS[POE][HO] 10/100/1000 MBPS INTELLIGENT REDUNDANT RING GIGABIT SWITCH WITH OPTIONAL POE+ QUICK START GUIDE

CWGE2SFP. Commercial Grade 10/100/1000BASE-T(X) to 1000BASE-FX Gigabit Ethernet Media Converter INSTALLATION AND OPERATION MANUAL

CNFE2DOE2 TERMINAL SERVER INSTALLATION AND OPERATION MANUAL

CNFE2MC2C/M. 10/100Mbps Ethernet Electrical to Optical Media Converter with Contact Closure Relay INSTALLATION AND OPERATION MANUAL

CLFE(X)UTP INSTALLATION AND OPERATION MANUAL

Connecting a Cisco Reader Module

CLFE(X)COAX INSTALLATION AND OPERATION MANUAL

CNGE2+2SMS[POE][HO] 10/100/1000 MBPS INTELLIGENT REDUNDANT RING GIGABIT SWITCH WITH OPTIONAL POE+ QUICK START GUIDE

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Ethernet over Copper Transmission Extenders. Ethernet Transmission over Coaxial or UTP Cable. Fiber Optic and Ethernet Network Solutions

INDUSTRIAL POE SWITCH

KOM600/KOM600G Fiber Media Converter Hardware Installation Manual

FSM-510G Series Ethernet Management Switch Quick Start Guide

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

8~14-Port Managed Ethernet Switch

PT-7728/7828 Quick Installation Guide

16Hi HARDWARE INSTALLATION GUIDE

EDS-G308 Series Quick Installation Guide

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Quick Start Guide. Industrial Managed Gigabit Ethernet PoE+ Switch LPH2008A-4GSFP

Connecting a Cisco Input Module

... light years ahead. Instruction Manual S711D & S7711D UNIVERSAL DATA TRANSMISSION SYSTEM

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

Digital Keypad Introduction

Hardened PoE Ethernet Switch

NPort S8000 Series Quick Installation Guide

Serial Data DIN Fiber Link System

EDS-G205-1GTXSFP Quick Installation Guide

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

PTC-101-M12 Hardware Installation Guide

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Manual Documentation Number EIR418-2SFP-T 0912m

Hardened Media Converter

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Installation and Configuration Guide

Wireless Ethernet as Easy as Power, Point & Play. Fiber Optic Copper Wireless

Features and Benefits. Certifications

Preface. Media Converter

SICOM3005A Switching Serial Port Server Hardware Installation Manual

Quick Installation Guide

Fiber optic converter audio and CAN TA OPERATION MANUAL

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

16x16 Modular Matrix Switch VM1600

INSTALLATION INSTRUCTIONS. ACB-100 Audio Control Board. This document describes the installation procedure for the ACB-100 Audio Control Board.

IES308-2F. Introduction: Packing List: Features: 8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

Overview. Features CHAPTER

F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual

Numerics INDEX. 10/100/1000 ports cable lengths 2-4, B-6 connecting to 2-38, B-43 described /100 ports

IPC194. ipconv Protocol Converter

Industrial Serial Device Server

RS-232 Industrial Media Converter

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Industrial PoE Media Converter

RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

PTC-101 Quick Installation Guide

Moxa TCC-100 Series Hardware Installation Guide

IKS-G6524A/G6824A Series Quick Installation Guide

Black Box Tech Support: FREE! Live. 24/7.

F271XA Fiber-Optic Telephone Modem Technical Manual

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4850GTS

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Signamax Connectivity Systems

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

Quick Start Installation Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

EDR-G902/G903 Quick Installation Guide

TRC-190 User s Manual

Dell SC7020 Storage Controller Getting Started Guide

16x16 Modular Matrix Switch VM1600A

32 x 32 Modular Matrix Switch

RS-422/485 to Fiber Industrial Converter

Cisco ONS CL Shelf Assembly Hardware

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

ROCKETLINX ES7110 ES7110/ES7110-VB

Features and Benefits. Certifications

ICS-G7526A/G7528A/ G7826A/ G7828A Series Quick Installation Guide

-C5RS-LC RS232 EXTENDER

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Transcription:

2-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BI-DIRECTIONAL DATA + AIPHONE INTERCOM + 4 CONTACT CLOSURE + 100MB ETHERNET + REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS The series utilize 10-bit digital video encoding and decoding for high-quality video transmission that meets the requirements of EIA RS-250C for short-haul video transmission. These environmentally hardened units provide transmission of two independent video channels and two bi-directional data channels. They also provide transmission of one Aiphone intercom channel and four contact closure channels with tamper supervision in addition to one 10/100Mb Ethernet channel. The ComNet has dual optical (SFP) ports to provide a redundant point-to-point fail safe topology in the event of loss of one fiber or one optical module. Operational status can be monitored by using the web management interface through the addition of the ComNet network managed chassis and network management interface module. Bi-color (red/green) LED indicators are provided for confirming operating status in addition to alarm contacts for fault monitoring. See Figure 15 on Page 9 for LED explanations. Packaged in the exclusive ComNet ComFit housing, these units may be either wall or rack-mounted (using ComNet C2 network-managed rack), or may be DIN-rail mounted by the addition of ComNet model DINBKT1 adaptor plate. See Figure A on Page 10 for mounting instructions. INS REV- 06/22/12 PAGE 1

FIGURE 1 TRANSMITTER AND RECEIVER Optical fiber determined by Selection of Small Form-factor Pluggable (SFP) modules*. ( ) BLACK (+) BLACK W/ WHITE STRIPE ( ) BLACK (+) BLACK W/ WHITE STRIPE Power Supply: Dual 8-24VDC @ 4W Rack Mount: C2 Network-Managed * One SFP required for point-to-point operation. Two SFPs required for redundant operation. Consult factory for compatible SFP Modules. NOTE: Remove PWR1 Electrical Connector for Rack Mount Units FIGURE 2 FVT20D2I1C4E TRANSMITTER FIGURE 3 FVR20D2I1C4E RECEIVER FRONT PANEL REAR PANEL FRONT PANEL REAR PANEL INS REV- 06/22/12 PAGE 2

FIGURE 4 RJ45 BREAK-OUT FVT20D2I1C4E TRANSMITTER 4 pc. Factory Supplied RJ-45 PORTS Located on Rear Panel D D A VIEW INSIDE RJ-45 PORT C D (DATA PORTS) PIN # Wire Color Data Connections 1 Blue DATA OUT 2 Orange DATA OUT + 3 Black DATA IN + 4 Red RELAY OUT 5 Green RELAY OUT 6 Yellow DATA IN 8 White +5V (BIAS) C (CONTACT PORT) RJ-45 BREAK-OUT KIT Screw Number Corresponds to RJ-45 Port Pin Number PIN # Wire Color TX Connections 1 Blue IN 1+ 2 Orange IN 1 3 Black IN 2+ 4 Red IN 3+ 5 Green IN 3 6 Yellow IN 2 7 Brown IN 4+ 8 White IN 4 A (AIPHONE PORT) PIN # Wire Color Aiphone Connections 1 Blue LE-D - TERMINAL 2 Orange LE-D 1 TERMINAL 3 Black LE-D E TERMINAL 4 Red RELAY OUTPUT COM 5 Green RELAY OUTPUT N.C. 6 Yellow RELAY OUTPUT N.O. 8 White GND INS REV- 06/22/12 PAGE 3

FIGURE 5 RJ45 BREAK-OUT FVR20D2I1C4E RECEIVER 4 pc. Factory Supplied RJ-45 PORTS Located on Rear Panel D D A VIEW INSIDE RJ-45 PORT C D (DATA PORTS) PIN # Wire Color Data Connections 1 Blue DATA OUT 2 Orange DATA OUT + 3 Black DATA IN + 4 Red RELAY OUT 5 Green RELAY OUT 6 Yellow DATA IN 8 White +5V (BIAS) C (CONTACT PORT) RJ-45 BREAK-OUT KIT Screw Number Corresponds to RJ-45 Port Pin Number PIN # Wire Color RX Connections 1 Blue OUT1 + 2 Orange OUT1 3 Black OUT2 + 4 Red OUT3 + 5 Green OUT3 6 Yellow OUT2 7 Brown OUT4 + 8 White OUT4 A (AIPHONE PORT) PIN # Wire Color Aiphone Connections 1 Blue LEF E TERMINAL 2 Orange LEF 1 TERMINAL 3 Black LEF TERMINAL 4 Red NC 5 Green CONTACT INPUT + 6 Yellow NC 8 White GND NC = No Connection INS REV- 06/22/12 PAGE 4

FIGURE 6 DATA SWITCH POSITIONS The mode for each data channel is configured using a set of two switches labeled DATA1 (S3) and DATA2 (S4), located on the front panel of the unit. DATA1 (S3) DATA2 (S4) 1 2 1 2 Resulting Mode ON ON ON ON RS232 ON OFF ON OFF RS422, Bi-Phase or Manchester OFF ON OFF ON RS485 2-Wire, Sensornet OFF OFF OFF OFF RS485 4-Wire FIGURE 7 RJ-45 PIN OUT PIN # Wire Color Data Connections 1 Blue DATA OUT 2 Orange DATA OUT + 3 Black DATA IN + 4 Red RELAY OUT 5 Green RELAY OUT 6 Yellow DATA IN 8 White +5V (BIAS) PIN # RS232 RS422 RS485 2-Wire RS485 4-Wire 1 NC RS422 OUTPUT NC RS485 OUTPUT 2 RS232 OUTPUT RS422 OUTPUT + NC RS485 OUTPUT + 3 NC RS422 INPUT + RS485 INPUT + RS485 INPUT + 4 RELAY OUT RELAY OUT RELAY OUT RELAY OUT 5 RELAY OUT RELAY OUT RELAY OUT RELAY OUT 6 RS232 INPUT RS422 INPUT RS485 INPUT RS485 INPUT 7 GND GND GND GND 8 +5V (BIAS) +5V (BIAS) +5V (BIAS) +5V (BIAS) NC = No Connection INS REV- 06/22/12 PAGE 5

FIGURE 8 DATA CONNECTIONS See Page 5 for Switch Settings Customer Equipment FVT20D2I1C4E FVR20D2I1C4E Customer Equipment RS232 Data Transmit Data Receive Signal Ground GND GND Data Receive Data Transmit Signal Ground RS422 Data Out (+) Data Out (-) Data In (+) Data In (-) DOUT(-) DOUT(-) Data In (+) Data In (-) Data Out (+) Data Out (-) Bi-phase or Manchester Data In (+) Data In (-) DOUT(-) Data Out (+) Data Out (-) 2-Wire RS485, Sensornet Data (A) Data (B) Data (A) Data (B) 4-Wire RS485 Data Out (A) Data Out (B) Data In (A) Data In (B) DOUT(-) DOUT(-) Data In (A) Data In (B) Data Out (A) Data Out (B) FIGURE 9 POSSIBLE ETHERNET CONFIGURATION Ethernet IEEE 802.3 Network Element determined by user. Optical Fiber SC or LC Connectors SINGLE FIBER SFP MODULE CAT5e/6 with RJ45 Connections CAT5e/6 with RJ45 Connections Ethernet IEEE 802.3 Network Element FVT20D2I1C4E FVR20D2I1C4E Ethernet IEEE 802.3 Network Element INS REV- 06/22/12 PAGE 6

FIGURE 10 SFP CONNECTIONS Number of fibers and type of fiber connectors will be determined by selected SFP modules and if point-to-point or redundant modes are required. FIGURE 11 AIPHONE INTERCOM CONNECTIONS The units are designed to operate with the Aiphone LE-D and LEF intercom system. FVT20D2I1C4E PIN # Wire Color Aiphone Connections 1 Blue LE-D - TERMINAL 2 Orange LE-D 1 TERMINAL 3 Black LE-D E TERMINAL 4 Red RELAY OUTPUT COM 5 Green RELAY OUTPUT N.C. 6 Yellow RELAY OUTPUT N.O. 8 White GND FVR20D2I1C4E PIN # Wire Color Aiphone Connections 1 Blue LEF E TERMINAL 2 Orange LEF 1 TERMINAL 3 Black LEF TERMINAL 4 Red NC 5 Green CONTACT INPUT + 6 Yellow NC 8 White GND LE-D FVT20D2I1C4E FVR20D2I1C4E LEF E 3 3 1 2 2 1 1 1 E 5 4 6 Form C Relay Door/Barrier 5 7 Output Contact Input INS REV- 06/22/12 PAGE 7

FIGURE 12 CONTACT SWITCH POSITIONS The mode for contact closure operation is configured using a set of two switches labeled CONTACT (S1) located on the front panel of the unit. There are four supervised contacts in the forward (video) direction. NOTE: These switch settings refer to the transmitter (FVT20D2I1C4E). On the receiver (FVR20D2I1C4E), S1 SWITCH 1 inverts the contact outputs. S1 SWITCH 2 is not used. CONTACT (S1) 1 2 Resulting Mode ON ON Full Supervision When a 1K resistor is connected in series with the contact closure input, and a 1K resistor is connected in parallel across the contact closure input. Both open circuits and short circuits can be detected as well as normal opens and closes. ON OFF Series Supervision When a 1K resister is connected in series with the contact closure input. In this mode, shorts across the contact inputs can be detected but open circuits cannot be detected. OFF ON Parallel Supervision When a 1K resistor is connected in parallel across the contact closure input. In this mode, open circuits can be detected but short circuits cannot be detected. OFF OFF No Supervision The contacts will behave as normal contacts with no Supervision. FIGURE 13 CONTACT CLOSURE SUPERVISED INPUT CIRCUIT INTERNAL 5V 1K Series* 1K * Optional external resistors (provided) are required for supervision. Place close to the switch for optimal results. 1K Parallel* 1K INS REV- 06/22/12 PAGE 8

FIGURE 14 ALARM SWITCH POSITIONS The mode for alarm operation is configured using a set of two switches labeled ALARM (S2) located on the front panel of the unit. There are two alarm outputs on each unit. One on each RJ45 data connector. See Figures 4 & 5 on Pages 3 & 4. ALARM (S2) NOTE: The ALARM will also open when Fiber Link on either SFP port is lost or if Power is lost on either unit. 1 2 Resulting Mode ON ON Alarm 1 SFP 1 Failure Alarm 2 SFP 2 Failure ON OFF Alarm 1 SFP 1 or SFP 2 Failure Alarm 2 Not Used OFF ON Reserved For Future Use OFF OFF Reserved For Future Use FIGURE 15 LED INDICATORS OFF RED GREEN FLASHING SFP SFP not installed No optical link Link is good and is in use Link is good but is not in use VIDEO No video signal An active video signal is present 10/100 LINK No Ethernet signal Ethernet signal linked CONTACT (C) One or more contacts are open Fiber link failed All four contacts are closed CONTACT (S) Supervised contact alarm or fiber link failed No supervised contacts in alarm state LE-D Quiet / No Audio Audio Present Call button active LE-F Quiet / No Audio Audio Present DATA IN Tri-state Low state High state Data activity DATA OUT Tri-state Low state High state Data activity POWER Unit powered down Unit powered up GREEN Solid: Link (no activity) Blinking: Activity Off: No link YELLOW Solid: Highest data rate (100Mbs) INS REV- 06/22/12 PAGE 9

MECHANICAL INSTALLATION INSTRUCTIONS INSTALLATION CONSIDERATIONS This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity. C2 NETWORK MANAGED RACKS FIGURE A Dimensions are for a standard ComNet two slot module.156 [3.96 mm] CAUTION: Although the units are hot-swappable and may be installed without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack. 1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel. Seating may require thumb pressure on the top and bottom of the card s front panel. CAUTION: Take care not to press on any of the LEDs..313 [7.95 mm] 2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack. WARNING: Unit is to be used with a Listed Class 2 power supply. IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. 3 CORPORATE DRIVE DANBURY, CT 06810 USA T: 203.796.5300 F: 203.796.5303 INFO@COMNET.NET 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS, UK LS27 7LE T: +44 (0)113 307 6400 F: +44 (0)113 253 7462 INFO-EUROPE@COMNET.NET 2018 Communications Networks Corporation. All Rights Reserved. ComNet and the ComNet Logo are registered trademarks of Communication Networks, LLC. INS REV- 06/22/12 PAGE 10