REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Similar documents
Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Rhino PSM Power Supplies. Operating Instructions

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable)

Industrial Power Supplies

Industrial Power Supplies

Power supply CP-C 24/5.0

Redundancy unit CP-A RU

RTU500 series Data Sheet Power Supply CP-E 24/2.5

MINI-PS AC/10-15DC/8

Industrial Power Supplies

Industrial Power Supplies

QUINT-BUFFER/24DC/24DC/40

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

PHOENIX CONTACT - 07/2006

Power supply CP-E 24/10.0 Primary switch mode power supply

Power supply CP-D 12/2.1 Primary switch mode power supply

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

ETD-BL-1T-OFF-CC- 10S

STEP-PS/1AC/24DC/1.75

Industrial Power Supplies

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS-3x AC/24DC/10

Redundancy Module QUINT-DIODE/40

PHOENIX CONTACT - 01/2007

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

Industrial Power Supplies

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

MINI MCR-SL-CVS NC

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

QUINT-PS AC/24DC/10

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Power supply CP-C 24/5.0

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

FLEX Ex Spring Clamp Terminal Base

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

PHOENIX CONTACT - 05/2007

QUINT-PS/24DC/48DC/ 5

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Universal Power Supplies

Operating instructions. Switching amplifier DN0210 DN / / 2015

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Electronic timer CT-ERD.12

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

PanelView Plus/VersaView CE Terminals and Display Modules

CompactBlock Guard I/O EtherNet/IP Safety Modules

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

PMT. Safety Standards. Model Number:

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Electronic timer CT-AHD.22

PMT. Model Number: CC Code PM 24V 200W 1 A Panel Mount Product Type T Enclosed L L Frame*

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Enclosed Power Supplies

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

MINI MCR-SL-PT100-UI-200

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

PI-EX-ME-2NAM/COC-24VDC

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

QUINT-PS/ 1AC/24DC/ 5

TRC-190 User s Manual

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

PMT. Safety Standards. Model Number:

CliQ II Buffer Module 24V 20A / DRB-24V020AB

Operating instructions. Speed monitor D / / 2014

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

PHOENIX CONTACT - 01/2008

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

Transcription:

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1

Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2

Dimensions drawings: TSP-REM600 Bottom view Top view Side view Front view Weight: 0.992lb Gewicht: 0.45kg Note This instruction cannot claim all details of possible equipment variations, nor in particular can they provide for every possible example of installation, operation or maintenance. Further information is available from your local distributor office or from the TSP industrial power supply data sheet. Subject to change without prior notice. In order to guarantee safe operation of the TSP-REM360 or TSP-REM600 in combination with the TSP power supplies and to be able to make use of all the functions, please read these instructions thoroughly! Seite 3

English Warning POTENTIAL ELECTROSTATIC CHARGING HAZARD Prevent unintentional contact with a dry cloth. Do NOT clean surfaces with a dry cloth! Clean ONLY with a damp cloth The TSP-REM360 and TSP-REM600 is designed and constructed in accordance with the safety requirements of IEC 60950-1, EN 60950-1, UL 60950-1, Edition and is certified to IEC/EN/UL 60079-15 (protection type n Class I, Zone 2, AEx na nc IIC T4 Gc and Class I, Division 2, Group A,B,C,D. The TSP-REM360 as well as the TSP-REM600 built-in modules are designed especially for use in process automation and other industrial applications. The power supply units are Unit Group II Category 3G components. They must be installed in an enclosure or cabinet rated min. IP54. The enclosure / cabinet must comply with the requirements of EN60079-15:2005. Components with dangerously high voltage and high stored energy are located in the device. However, these are inaccessible. Failure to properly maintain the TSP-REM360 or TSR-REM600 can result in death, severe personal injury or substantial property damage. The TSP-REM360 or TSPREM600 may only be installed and put into operation by qualified personnel. The corresponding national regulations (e.g. UL, ANSI, VDE, DIN) must be observed. The successful and safe operation of this module is dependent on proper storage, handling, installation and operation. The potentiometer to adjust the output voltage is only allowed to be actuated using an insulated screwdriver, because accidental contact may be made with parts inside the power supply carrying dangerous voltages. Please observe following points before putting the device into operation: Read operating instructions thoroughly. That the input wiring is sufficiently dimensioned! That the output wiring is dimensioned according to the maximum output current or separately protected! Sufficient cooling is guaranteed! The temperature of the housing can become very high, depending on the ambient temperature and load. Caution: Risk of electrical shock and electrical discharge. The TSP-REM360 nor TSP-REM600 nor the power supply must not be opened until at least 5 minutes after complete disconnection of the mains. Electrostatic sensitive device. Qualified and trained personnel only may open the TSP-REM360 or TSP-REM600 or the power supply. Attention: In case of non-observance or exceeding the mentioned limiting value of the data sheet, the function and electrical safety can be impaired and can destroy the TSP-REM360 or TSP-REM600 and/or the power supply. Before installation ensure that the main switch is switched off and prevented from being switched on again. In case of non-observance, touching of any live components or improper dealing with this TSP-REM360 or TSP-REM600 or power supply can result in death or fatal injury. Danger: Never work on the TSP-REM360 or TSP-REM600 or power supplies if power is applied! 1. Description and construction With this TSP-REM modules and two power supplies of the TSP series (70, 90, 140, 180, 360 and 600 watt models) a highly reliable, true redundant power system can be configured without any additional components. This module enforces the equivalent sharing of the output current by each power supply. The system is fully redundant and provides the output power even if one power supply has completely failed e.g. by short circuit on the output. In the event of either, one power supply failing or being disconnected, the second device will automatically supply the full current to the load. The redundancy of the system is monitored and if lost, indicated by an alarm output. The inputs are hot swappable and can be loaded up to 15A (TSP-REM360) or 25A (TSP-REM600) each. The output of the TSP-REM360 or TSP-REM600 should not be overloaded to provide a proper n+1 redundancy system. The max output current is 15A (TSP-REM360) or 25A (TSP-REM600) as well. Both TSP power supplies have to be adjusted to Vout = 24.00 24.05Vdc before connecting them to the TSP-REM360 or TSP-REM600. Afterwards the connection between the TSP (TSP xxx-124) and Input 1 (see Fig 3.1; +Vin and Vin; J1 pin 1 & pin 2 and chapter 2.2.1) as well as Input 2 (see Fig 3.1; +Vin and Vin; J1 pin 3 & pin 4 and chapter 2.2.1) and the remote sensing (see Fig. 3.1; J3 & J4) between these two devices and the TSP-REM360 or TSP-REM600 using the wire supplied with the TSP-REM360 or TSP-REM600 modules can be made (see Fig. 2.1 and Fig. 3.1, J4). Now the load can be connected to DC-Out (see Fig. 3.1, J2 pin 1, pin 2, pin 3 & pin 4 & chapter 2.2.2). The output voltage on the TSP- REM360 or TSP-REM600 can be adjusted between 24 and 27Vdc using the potentiometer on the TSP-REM360 or TSP-REM600 (see Fig 3.1). The TSP-REM360 and TSP-REM600 are built-in devices. The mounting position has to fulfil the requirements for fireproof case according to UL60950-1, IEC/EN 60950-1 or other appropriate national standard. The relevant UL regulations or equivalent national regulations must be observed during installation. The TSP-REM360 and TSP-REM600 are designed for mounting on a DIN rail TS35 (DIN EN 50022-35x15/7.5). The output voltage of the TSP-REM360 as well as of the TSP-REM600 is protected against short circuit and open circuit conditions. 2. Installation A sufficiently strong DIN-rail has to be provided. The correct mounting position for optimal cooling performance must be observed. Above and below the TSP-REMxxx modules a minimum free space of 80mm [3.15in] is required and on each side of the TSP-REMxxx modules a minimum space of 50mm [1.97in] is required which allows air convection. The air temperature measured 10mm [0.39in] below the device must not exceed the specified values in the data sheet. Observe same power derating above ambient temperatures of 40 C as specified for the TSP power supplies. Seite 4

English 2.1 Assembly To fix device on the DIN-rail, hook top part of clip on DIN-rail, push down and inward until you hear a clipping sound. To remove the device, pull the latch of the clip with the aid of an insulated flat head screwdriver. When clip has cleared bottom DIN rail remove the screwdriver from recess. Lift the device off DIN-rail. Wall mounting or chassis mounting can be achieved by use of optional mounting bracket TSP-WMK01 (1 bracket, see Fig. 4.1). Remove the DIN-clips by removing the screw and place the mounting brackets in the same place as the DIN-clips. Use the countersink screws, which are included with the wall mounting kit (1 countersink screw with TSP-WMK01) to fix the mounting brackets on the TSP-REM360 or TSP-REM600 (tightening torque 0.8-0.9Nm). 2.2 Connecting cable Only qualified personnel may carry out the installation. The device is equipped with COMBICON connector. This reliable and easy-to-assemble connection method enables a fast connection of the device. 2.2.1 Input 1 and Input 2 (Fig. 3.1 Connector J1, pin 1, pin 2, pin 3 & pin 4): The connection is made by using the Vin and +Vin connections at Input 1 as well as at Input 2 and has to be carried out in accordance with the local regulations. Sufficiently dimensioned wiring has to be ensured (see 2.2.1.1). To achieve a reliable and shockproof connection strip the connecting ends according 2.2.1.1. If flexible wires are used the wires have to be terminated. (e.g. by using ferrules) 2.2.1.1 Connections and terminal assignment Solid or stranded wires Torque Stripping length Device Terminals Function TSP 090-124 TSP 180-124 TSP 360-124 TSP 600-124 [mm 2 ] [AWG] [Nm] [mm] Vin & +Vin Input 1 Input Voltage (24Vdc) 0.5 2.5 24 12 0.5 0.6 7.0 Vin & +Vin Input 2 Input Voltage (24Vdc) 0.5 2.5 24 12 0.5 0.6 7.0 +Vout & -Vout Output Voltage (24Vdc) 0.5 2.5 24 12 0.5 0.6 7.0 Signal Relay inputs and relay outputs 0.2 2.5 32 12 0.5 0.6 7.0 Vin & +Vin Input 1 Input Voltage (24Vdc) 1.0 2.5 18 12 0.5 0.6 7.0 Vin & +Vin Input 2 Input Voltage (24Vdc) 1.0 2.5 18 12 0.5 0.6 7.0 +Vout & -Vout Output Voltage (24Vdc) 1.0 2.5 18 12 0.5 0.6 7.0 Signal Relay inputs and relay outputs 0.2 2.5 32 12 0.5 0.6 7.0 Vin & +Vin Input 1 Input Voltage (24Vdc) 1.0 4.0 18 10 0.5 0.6 7.0 Vin & +Vin Input 2 Input Voltage (24Vdc) 1.0 4.0 18 10 0.5 0.6 7.0 +Vout & -Vout Output Voltage (24Vdc) 1.0 4.0 18 10 0.5 0.6 7.0 Signal Relay inputs and relay outputs 0.2 2.5 32 12 0.5 0.6 7.0 2.2.2 Output (Fig. 3.1 Connector J2, pin 1, pin 2, pin 3 & pin 4): The 24VDC connection is made using the +Vout and -Vout connections. All output terminals should be connected to the load. Make sure that all output lines are dimensioned according to the maximum output current (see 2.2.1.1) or are separately protected! The wires on the secondary side should have large cross sections in order to keep the voltage drops on these lines as low as possible. To achieve a reliable and shockproof connection strip the connecting ends according 2.2.1.1. If flexible wires are used the wires have to be terminated. (e.g. by using ferrules) At the time of delivery, the output voltage is 24VDC. The output voltage can be set (using an insulated screwdriver) from 24 to 27VDC on the potentiometer (see Fig. 3.1). The device is protected against overload and short circuit. 2.2.3 Signalling (Fig. 3.1 Connector J5, pin 1 & pin 2): The DC OK outputs are for enabling monitoring of the functions of the two TSP power supplies. The floating DC OK signal contacts (see Fig. 3.1 Connector J5, pin 1 & pin 2) is monitoring if the output voltage of the TSP power supplies, which are connected to the TSP-REM360 Input 1 and Input 2 or TSP-REM600 Input 1 and Input 2, is present. If one of the devices is disconnected or damaged, e.g. in the event of a power supplies internal short circuit, the alarm is generated. The contact on the relay will switch off (relay contact open). If both TSP power supplies provide at least an output voltage of 21.5Vdc the relay contact is closed and signalise that both power supplies are in operation. If the output voltage of the TSP-REM360 or TSP- REM600 is present the relay contact (30Vdc / 1A) is closed. It is detected by measuring the TSP-REM360 or TSP-REM600 input voltage at Input 1 as well as at Input 2. 2.2.4.1 Inputs-ON LED: The Inputs-ON LED is a green colour LED that indicates the status of the TSP-REM360 or TSP-REM600 inputs and enables visual evaluation of the function locally in the control cabinet. Inputs-ON LED green on both TSP power supplies are supplying the TSP-REM360 or TSP-REM600 with 24Vdc. Inputs-ON LED green off one of the two or even both power supplies failed. 3. Function 3.1 Remote ON/OFF: The TSP-REM360 as well as the TSP-REM600 devices provides an external remote on/off function by use of pin 3 & pin 4 at connector J5 (see Fig. 3.1). To switch off the power supply and TSP-REM360 or power suply and TSP-REM600 a connection between Connector J5 pin 3 and Connector J5, pin 4 by use of a switch or similar has to be made. At open connection between J5 pin 3 and J5 pin 4 the device is providing the adjusted output voltage. Seite 5

4. Compliance to UL508C The TSP-REM360 is a is a built-in device and to comply with UL508C the device must be installed in a cabinet with minimum dimensions of: 400mm (Width) x 500mm (Height) x 200mm (Depth) 4.1 Operating Temperature Ranges and load derating: Depends on the TSP connected to the TSP-REM360. Please see operating temperature range and load derating at the TSP power supplies datasheet or TSP operating instructions. 5. Technical Specifications 4.1 Input Specifications Order code Model TSP-REM360 TSP-REM600 * Output voltage adjustable ** Maximum current at Vout nom. 5.2 Output Specifications Input max. Input Power * Output Voltage max. Output Current 2 x 24 Vdc 2 x Control Input 2 x 24 Vdc 2 x Control Input Output Voltage adjustable Range with Potentiometer 2 x 360 Watt 24 Vdc 15.0 A 2 x 600 Watt 24 Vdc 25.0 A 24-27 Vdc Ripple and Noise (20MHz Bandwidth) at V in nom und I out max 230mV pk-pk max Max. Capacitive Load unlimited English 5.3 General Specifications Operating Temperature Range -25 C +70 C -13 F +158 F Cooling Convection cooling; no internal fan Storage Temperature Range -25 C +85 C -13 F +185 F Load Derating above +40 C (104 F) According the load derating of TSP xxx-124 used Humidity (non condensing) 95% rel H max. Pollution Degree 2 Temperature Coefficient 0.02%/K Reliability, calculated MTBF in accordance to IEC 61709 >350'000 hours Remote ON/OFF see Fig. 3.1 2 pin connector (see Fig. 3.1; J5 pin 3 & pin 4) connect via a switch Contact closed = Device off Alarm Relay Contact 30Vdc / 1A Redundancy OK signal (Alarm) Trigger threshold at 18-22VDC, Contact open if both inputs failed Remote link cable (0.5m) 2 cables included with TSP-REM360 module Case protection in accordance to IEC 529 IP20 Isolation See Safety Standards Safety Standards according to - Information Technology Equipment - Industrial Control Equipment IEC / UL / EN 60950-1 UL 508 Electromagnetic compatibility (EMC) Emissions in correspondence to connected units (no internal switching device Electromagnetic compatibility (EMC) Immunity in correspondence to connected units (no internal switching device Environment Vibration IEC 60068-2-6 3 axis, sine sweep, 10 55Hz, 1g, 1oct/min. Shock IEC 60068-2-27 3 axis, 15g, half sine, 11ms Enclosure Material Aluminium (Chassis) / Zinc plated Steel (Cover) Mounting DIN-Rail mounting For DIN-Rails as per EN 50022-35 x 15 / 7.5 (snap-on self-locking spring) Wall mounting With wall mounting bracket option TSP-WMK01 (see datasheet page 8) Connection Screw terminals Seite 6

Block diagram TSP-REM360 and TSP-REM600 J1.2 J1.1 J2.3 J2.4 J2.1 J2.2 J3.1 J3.2 J1.4 J1.3 J4.1 J4.2 Fig.: 1.1 J5.1 J5.2 J5.3 J5.4 Connection of TSP-REM360 or TSP-REM600 Remote Link 1 Remote Link 2 Fig.: 2.1 Seite 7

Connectors of TSP-REM360 and TSP-REM600 Fig.: 3.1 J1 J2 J3 Voltage control 1 for Input 1 J4 Voltage control 2 for Input 2 J5 Pin 1 Input 1 -Vin GND (-) S+ S+ DC-OK Signal Pin 2 Input 1 +Vin GND (-) S- S- DC-OK Relay contact Pin 3 Input 2 -Vin Vout (+) - - Remote ON/OFF Pin 4 Input 2 +Vin Vout (+) - - Remote ON/OFF Wall mounting brackets (TSP-WMK01) for TSP-REM360 55.0 (2.16) Fig.: 4.1 Seite 8