BD-6500BT Bluetooth 2D Barcode Scanner Configuration Guide

Similar documents
MK D Imager Barcode Scanner Configuration Guide

FD-011WU. 2D Barcode Reader User Guide V1.6CC

2D Barcode Reader User Guide V 1.2.1

IPDA014-2D. Embedded 2D Barcode Scan Engine. User Guide

2D Hand-held Barcode Scanner User Guide

Table of Contents Sleep Settings How to Configure the Scanner. 7 Chapter 2 System Setup

Disclaimer. Please read through the manual carefully before using the product and operate it

2D Barcode Reader User Guide V 1.2.3

2D BARCODE SCANNER CA-SC-20200B

If you want to do other configurations please refer to below programming barcodes.

ASCII Code - The extended ASCII table

Wireless 2D Pocket barcode scanner

marson MT8200S 2D Handheld Scanner User Manual V / 6 / 25 - I -

PureScan - ML1. Configuration Guide. Wireless Linear Imager Wireless Laser scanner - 1 -

NC-1200 BARCODE SCANNER. Configuration Guide - 1 -

BARCODE SCANNER. Configuration Guide - 1 -

Setting code User Manual

User s Manual. Xi3000 Scanner. Table of Contents

Xi2000-BT Series Configuration Guide

NT-1200 CCD Wired Barcode Scanner Overview

OOstaExcel.ir. J. Abbasi Syooki. HTML Number. Device Control 1 (oft. XON) Device Control 3 (oft. Negative Acknowledgement

2D barcode scanner User Manual

Configuration Manual PULSAR C CCD SCANNER. Table of Contents

If you want to have other configurations please refer to below programming barcodes. Check Scanner Version

Z3S. Quick Setup Guide V Connection Mode. Working via Bluetooth. Barcode Programming. Working via USB cable

User s Guide. Linear Imager

Hand Held Linear Imager

000A1 Display inward character string(custom) USB-HID Single not triggered Not:CCD inapplicability Continuous Scan Mode

If you want to do other configurations please refer to below programming barcodes.

Wireless 2D Pocket barcode scanner

Wearable 2D Pocket barcode scanner

CCD - 75 USB. Programming Manual. GOMARO s.a. - Z.I. La Rosaire 5 - CH Aclens

GS500 2D Area-Imaging Scanner. User Manual

Manuel de programmation du lecteur LDT75C ver 2.1

EXPERIMENT 8: Introduction to Universal Serial Asynchronous Receive Transmit (USART)

Delivery content * Pocket Barcode scanner x 1 * Mini USB cable x 1 (for charging only) * Quick instructions x 1 * Strap x 1

Area Imager Bar Code Scanner 2 D C O N F I G U R A T I O N G U I D E

Number Systems II MA1S1. Tristan McLoughlin. November 30, 2013

Introduction FCC Statement

DLL2020. Software Configuration Manual

2D Imaging Barcode Scanner GLLS. Programming Guide. Advanced Handheld High-Speed Laser Scanner

Advanced Handheld High-Speed Laser Scanner

Preliminary draft_1. Prefix Scanned Data Suffix. Intercharacter Delay. Intercharacter Delay

BARCODE SCANNER. FUZZYSCAN FAMILY Quick Start Guide

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon Telephone: (541) Fax: (541)

2D Imaging Barcode Scanner GLLS. Programming Guide. Advanced Handheld High-Speed Laser Scanner

1. Character/String Data, Expressions & Intrinsic Functions. Numeric Representation of Non-numeric Values. (CHARACTER Data Type), Part 1

XL D Barcode Scanner User's Manual V1.0

nlscan.com Tools Exposure Imaging Mode ** Normal Exposure Mode Pro CMD Reflections Eliminating Mode Pro CMD Page 36

EXPERIMENT 7: Introduction to Universal Serial Asynchronous Receive Transmit (USART)

Delivery content * Pocket Barcode scanner x 1 * Mini USB cable x 1 (for charging only) * Quick instructions x 1 * Strap x 1

2a. Codes and number systems (continued) How to get the binary representation of an integer: special case of application of the inverse Horner scheme

Laser Barcode Scanner ARP Nr User s Manual

Wired Laser Barcode Scanner User Manual V:1509

APPENDIX E COMMAND BARCODES

The following are the data types used in the C programming language:

RT206 User Guide. RT206 OEM 2d Scan Engine User Guide

Low voltage Alarm: Scanner will make 5x beeps to remind you that it's under low voltage. Plug the USB cable to charge power for it.

COPYRIGHT 2009,SCSC. Manual P/No: SCCM - 80S-01A Released Date: Oct 31, 2009

RT209 OEM 2d Scan Engine User Guide

Menu & commands booklet FOR BAR CODE SCANNERS * *

广州虹源电子有限公司. Guangzhou Hong yuan Electronic co.,ltd. Configuration Manual

1. Factory Default Se ng (include below three steps)

Setup Procedures 2 Batch Setup 3. Bar Code Setup Menu 5. 1 Device Selection and Default. 2 Beep and Delay Keyboard Wedge..

Chapter 3. Information Representation

Factory Default Configuration. Factory Default Configuration

Characters Lesson Outline

1.1. INTRODUCTION 1.2. NUMBER SYSTEMS

AS-8050 CCD Scanner User Guide

Pock et b arcod e s cann er

2D Wired Barcode Scanner Overview. Keyboard Language In order to let scanner upload the codes in a correct way, you have to set the keyboard language.

Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered.

If you want to do other configurations please refer to below programming barcodes.

ZBX P/N : MUL LASER LIGHT CAUTION DO NOT STARE INTO BEAM

CMSC 313 Lecture 03 Multiple-byte data big-endian vs little-endian sign extension Multiplication and division Floating point formats Character Codes

User s Manual. Addendum to. Ranger Wedge Interface. Part No. 25-WEDGE-06A Ver. April 1999

POSSAFE LQ300 BARKOD OKUYUCU. Configuration Manual

NLS-FM208 Industrial Scanner User Guide

Manual de Programación

GS100. CCD Barcode Scanner. User Manual

S-Series Sensor ASCII Protocol v8.1.0

Start Configuration. Chap.1 System Information. Set All default

2D Scan Engine Confguration Guide. 2D Barcode Scanner Configration Guide

Barcode Scanner. Model no. NuScan User s Manual

PS232. RS-232 to PS/2 Keyboard Port Adapter Part # SA0009 (Version 4.0) Copyright 2003 L3 Systems, Inc. Redmond

Flow chart of bar code reader setting

BAR CODE. SYMBOLOGY PROGRAMMING for POCKET SCANNERS

Code Reader 1000/1400/8000 Configuration Guide

NLS-EM3095 Embedded 2D Barcode Scan Engine. User Guide

If your CNC machine memory is full, the PocketDNC gives you more storage, enabling you to store and reload proven programs at a later date.

CMSC 313 COMPUTER ORGANIZATION & ASSEMBLY LANGUAGE PROGRAMMING LECTURE 02, FALL 2012

DATA REPRESENTATION. Data Types. Complements. Fixed Point Representations. Floating Point Representations. Other Binary Codes. Error Detection Codes

SGBS-310-2D 2D Barcode Scanner Integration Guide

Code Reader 1000/1400/8000 Configuration Guide

NT-1228BL. Quick Setup Guide V Connection Mode. Working via Bluetooth. Barcode Programming

MD5 Series Barcode Scanner

Serial Programming Command Manual

XB-8200 Hand Free Area Image Scanner Configuration Guide

2D Wired Barcode Scanner Overview

CCD-BARCODE SCANNER. Programming Manual. To program the device, scan the following codes: FIRST: start configuration %$ + / 0

Transcription:

BD-6500BT Bluetooth 2D Barcode Scanner Configuration Guide V 2.1

Table of Contents 1 Getting Started. 3 1.1 About This Guide.. 3 1.2 Barcode Scanning.. 3 1.3 Factory Defaults.. 3 1.4 Pairing Cradle 4 1.5 Pairing Smart Phone, Table PC.. 5 1.6 Multiple scanner pair one Cradle 6 1.7 Sleeping time setting 7 2 Cradle Communication Interfaces.. 8 2.1 USB interface. 8 2.2 USB COM Port Emulation. 8 2.3 USB Country Keyboard Types. 9 2.4 Convert Case. 11 3 General Configuration. 12 3.1 Trigger Mode. 12 3.2 Continue Mode 12 3.3 Video reverse 13 3.4 Beeper Good Read 13 3.5 Beeper Tone Good Read.. 13 3.6 Beeper Duration Good Read.. 14 3.7 Beeper Number Good Read 14 3.8 Barcode Scanning Delay 15 4 Data Formatting.. 16 4.1 General Configuration. 16 4.2 Add Prefix 17 4.3 Add Suffix 18 4.4 Clear All Prefix and Suffix. 18 5 Symbologies.. 19 5.1 General Settings. 19 5.2 1D Symbologies.. 20 5.2.1 Code 128.. 20

5.2.2 EAN-8 21 5.2.3 EAN-13 22 5.2.4 UPC-E.. 23 5.2.5 UPC-A.. 28 5.2.6 Interleaved 2 of 5. 30 5.2.7 Matrix 2 of 5 31 5.2.8 Industrial 2 of 5. 32 5.2.9 Code 39.. 33 5.2.10 CodaBar 35 5.2.11 Code 93 37 5.2.12 GS1-128 38 5.2 13 MSI.. 39 5.3 2D Symbologies 41 5.3.1 PDF 417.. 41 5.3.2 QR Code. 42 5.3.3 Data Matrix.. 43 5.3.4 Maxi Code. 44 5.3.5 Aztec. 45 5.3.6 Hanxin. 46 5.4 Postal Symbologies 47 5.4.1 China Postal Code 47 5.4.2 Telepen 48 6 Appendix.. 49 6.1 Appendix 1: ASCII Table. 49 6.2 Appendix 2: Digit Barcodes. 54 6.3 Appendix 3: Programming Command Guide.. 55

1. Getting Started 1.1 About This Guide This guide provides programming instructions for the BD-6500BT 2D BARCODER READER. Users can configure the BD-6500BT 2D BARCODER READER by scanning the programming barcodes included in this manual. 1.2 Barcode Scanning Powered by area-imaging technology and BD-6500BT 2D BARCODER READER patented Hercules technology, the BD-6500BT 2D BARCODER READER features fast scanning and decoding accuracy. Barcodes rotated at any angle can still be read with ease. When scanning a barcode, simply center the aiming beam or pattern projected by the BD-6500BT 2D BARCODER READER over the barcode. 1.3 Factory Def aults Scanning the following barcode can restore the engine to the factory defaults.. Restore All Factory Defaults Report Firmware version 3

1.4 Pairing Cradle 1. Scan "Default" 2. Scan "setting configuration" 3. Scan "open SPP" 4. Scan "disconnect previous pairing" 5. Scan Cradle bottom code 6. Scan "Repairing" 7.Save BT SPP setting 8. Scan "End BT SPP setting" 9. Apple device needs enable transmission, others need to disable Enable ios transmission Disable ios transmission 4

1.5 Pairing Smart Phone, Table PC 1 Scan "default" 2 Scan "setting configuration: 3 Open a HID connection 4 Disconnect previous pairing 5 BT visible setting 6 Save BT HID configuration 7 End BT HID configuration 8 Apple device needs to enable transmission, others disable transmission Enable ios transmission Disable ios transmission 9 Enable BT function in ipad or smart phone and then serach BT (NVC_MD_CS45) to pair. 5

1.6 Multiple scanner pair one Cradle (1) Start (2) Open SPP (3) Disconnected previous connection (4) Scan receiver barcode (5) Reconnected (5) Save (6) End (7) BT receiving setting Remark: Please follow the step (1) ~ (6) for the first scanner. When it is connected (Blue Light), read the barcode as below. Other scanners don t do this step, only need (1) ~ (6). 6

1.7 Sleeping time setting Sleeping mode Save Numeric 0 1 2 3 4 5 6 7 8 Sleeping mode setting step: 1. Scan default 2. Scan Sleeping Mode 3. Setting sleeping mode numeric: (Unit: minute) For example: Set sleeping mode in 10 minutes. Then needs to scan numeric 0, 1, 0. Remark: Sleeping time range is from 1 to 999 minutes, and each setting needs to have 3 digits. 4. Scan Save Remark: After setting sleeping time, it has to san save to keep the data in the scanner. If there is any mistake happens during configuration, it needs to redo each step again. 7

2. Cradle Communication Interf aces 2.1 USB Interface * USB-HID 2.2 USB COM Port Emulation If you connect the engine to the Host via a USB connection, the USB COM Port Emulation feature allows the Host to receive data in the way as a serial port does. A driver is required for this feature. USB COM Port Emulation 8

2.3 USB Country Keyboard Types Keyboard layouts vary from country to country. The default setting is 1-U.S. keyboard. *USA Belgium Brazil Canada Croatia Czech Denmark Finland France Germany Hungary Italy Latin Dutch Norway Poland Portugal Serbia 9

Slovakia Slovenia Spain Sweden Swiss-French Swiss-German Turkey-F Turkey-Q UK Japan 10

2.4 Convert Case Scan the appropriate barcode below to convert barcode data to your desired case. * No Case conversion Convert All to Upper Case Convert All to Lower Case Example: When the Convert All to Lower Case feature is enabled, barcode data AbC is transmitted as abc. 11

3. General Configuration 3.1 Trigger Mode If the Trigger Mode is enabled, you could activate the scanner by providing an external hardware trigger, or using a serial trigger command. When in manual trigger mode, the scanner scans until a barcode is read, or until the hardware trigger is released. When in serial mode, the scanner scans until a barcode has been read or until the deactivate command is sent. * Trigger Mode 3.2 Continue Mode This set the scanner to work in Continue mode. Continue Mode 12

3.3 Video Reverse On * Off 3.4 Beeper - Good Read * On Off 3.5 Beeper Tone - Good Read Low Middle * High 13

3.6 Beeper Duration - Good Read * Normal Short 3.7 Beeper Number - Good Read * 1 2 3 4 5 6 14

3.8 Barcode Scanning Delay * No Delay Delay 500ms Delay 2000ms 15

4. Data Formatting 4.1 General Configuration Add CR Add LF Add CR+LF Add TAB 16

4.2 Add Prefix Set Custom Prefix Save Not Save To set a customer prefix, scan the Set Custom Prefix barcode and the numeric barcodes which representing the hexadecimal values of a desired prefix, and then scan the Save barcode. Refer to Appendix 4: ASCII Table for hexadecimal values of characters. Example: Set the custom Prefix to ODE 1. Check the hex values of ODE in the ASCII Table. ( ODE : 4F, 44, 45) 2. Scan the Set Custom Prefix barcode. 3. Scan the numeric barcodes 9, 9, 4, F, 4, 4, 4 and 5 in Appendix 5. 4. Scan the Save barcode. 17

4.3 Add Suffix Set Custom Suffix Save Not Save To set a customer suffix, scan the Set Custom Suffix barcode and the numeric barcodes which representing the hexadecimal values of a desired suffix, and then scan the Save barcode. Refer to Appendix 4: ASCII Table for hexadecimal values of characters. Example: Set the custom Suffix to ODE 1. Check the hex values of ODE in the ASCII Table. ( ODE : 4F, 44, 45) 2. Scan the Set Custom Suffix barcode. 3. Scan the numeric barcodes 9, 9, 4, F, 4, 4, 4 and 5 in Appendix 5. 4. Scan the Save barcode. 4.4 Clear All Prefix and Suffix Clear all prefix and suffix 18

5. Symbologies 5.1 General Settings Enable All Symbologies 19

5.2 1D Symbologies 5.2.1 Code 128 Restore Factory Defaults Restore the Factory Defaults of Code 128 Enable/Disable Code 128 * Enable Code 128 Disable Code 128 Message Length Message length can be set to the maximum value or minimum value. The value between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming Command. Please check the programming command guide for the detail. Code 128 max length command: 020A03. The parameter of this command can be set from min to 90. Code 128 min length command: 020A02. The parameter of this command can be set from 0 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command: Max: 020A0325. Min: 020A0210. 20

5.2.2 EAN-8 Restore Factory Defaults Restore the Factory Defaults of EAN-8 Enable/Disable EAN-8 * Enable EAN-8 Disable EAN-8 Transmit Check Digit EAN-8 is 8 digits in length with the last one as its check digit used to verify the accuracy of the data. Transmit EAN-8 Check Digit * Do Not Transmit EAN-8 Check Digit Add-On Code An EAN-8 barcode can be augmented with a two-digit or five-digit add-on code on code on code to form a new one. In the examples below, the part surrounded by blue dotted line is an EAN-8 barcode while the part circled by red dotted line is add-on code. 21

Enable 2-Digit Add-On Code Disable 2-Digit Add-On Code Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code Add-On Code Required EAN-8 Add-On Code Required * EAN-8 Add-On Code Not Required ENA/JAN-8 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space. Enable ENA/JAN-8 Addenda Separator * Disable ENA/JAN-8 Addenda Separator UPC 22

5.2.3 EAN-13 Restore Factory Defaults Restore the Factory Defaults of EAN-13 Enable/Disable EAN-13 * Enable EAN-13 Disable EAN-13 Transmit Check Digit * Transmit EAN-13 Check Digit Do Not Transmit EAN-13 Check Digit Add-On Code Enable 2-Digit Add-On Code Disable 2-Digit Add-On Code Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code 23

Add-On Code Required EAN-13 Add-On Code Required * EAN-13 Add-On Code Not Required ENA/JAN-13 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space. Enable ENA/JAN-13 Addenda Separator *Disable ENA/JAN-13 Addenda Separator ISBN Translate When enable this feature and is scanned, ENA13 Book land symbols are translated into their equivalent ISBN number format. Enable ISBN Translate * Disable ISBN Translate 24

5.2.4 UPC-E Restore Factory Defaults Restore the Factory Defaults of UPC-E Enable/Disable UPC-E0/E1 Enable UPC-E0 Disable UPC-E0 Enable UPC-E1 Disable UPC-E1 UPCE0 Check Digit * Enable UPC-E0 Check Digit Disable UPC-E0 Check Digit 25

UPCE0 Expand UPCE0 expand expands the UPCE code to the 12 digits, UPC-A format. Enable UPC-E0 Expand * Disable UPC-E0 Expand UPCE0 Addenda Required When required is scanned, the scanner will only read UPC-E barcodes that have addenda. Enable UPC-E0 Required * Disable UPC-E0 Required UPCE0 Addenda Separator Enable UPC-E0 Separator * Disable UPC-E0 Separator UPCE0 Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will be not transmitted. Enable UPC-E0 Number System * Disable UPC-E0 Number System 26

UPCE0 Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda Enable 5 Digit Addenda Disable 5 Digit Addenda 27

5.2.5 UPC-A Restore Factory Defaults Restore the Factory Defaults of UPC-A Enable/Disable UPC-A * Enable UPC-A Disable UPC-A UPC-A Check Digit * Enable UPC-A Check Digit Disable UPC-A Check Digit UPC-A Addenda Required When required is scanned, the scanner will only read UPC-E barcodes that have addenda. Enable UPC-A Required * Disable UPC-A Required 28

UPC-A Addenda Separator Enable UPC-A Separator * Disable UPC-A Separator UPC-A: Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will be not transmitted. * Enable UPC-A Number System Disable UPC-A Number System UPC-A: Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda Enable 5 Digit Addenda Disable 5 Digit 29

5.2.6 Interleaved 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Interleaved 2 of 5 Enable/Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 *Disable Interleaved 2 of 5 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming Command. Please check the programming command guide for the detail. Interleaved 2 of 5 max length command: 020404. The parameter of this command can be set from min to 80. Interleaved 2 of 5 min length command: 020403. The parameter of this command can be set from 2 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 02040425. Min: 02040310. Interleaved 2 of 5 Check Digit No check Char *Validate and Transmit Validate not Transmit 30

5.2.7 Matrix 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Matrix 2 of 5 Enable/Disable Matrix 2 of 5 Enable Matrix 2 of 5 * Disable Matrix 2 of 5 Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Matrix 2 of 5 max length command: 020803. The parameter of this command can be set from min to 80. Matrix 2 of 5 min length command: 020802. The parameter of this command can be set from 1 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 02080325. Min: 02080210. 31

5.2.8 Industrial 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Industrial 2 of 5 Enable/Disable Industrial 2 of 5 Enable Industrial 2 of 5 *Disable Industrial 2 of 5 Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Industrial 2 of 5 max length command: 020603. The parameter of this command can be set from min to 48. Industrial 2 of 5 min length command: 020602. The parameter of this command can be set from 1 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 02060325. Min: 02060210. 32

5.2.9 Code 39 Restore Factory Defaults Restore the Factory Defaults of Code 39 Enable/Disable Code 39 * Enable Code 39 Disable Code 39 Transmit Start/Stop Character Transmit Start/Stop Character *Do not Transmit Start/Stop Character Code 39 Check Character No Check Char *Validate and Transmit Validate no Transmit 33

Code 39 Full ASCII Enable Code 39 Full ASCII *Disable Code 39 Full ASCII Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Code 39 max length command: 020308. The parameter of this command can be set from min to 48. Code 39 min length command: 020307. The parameter of this command can be set from 0 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 02030825. Min: 02030710. 34

5.2.10 Coda bar Restore Factory Defaults Restore the Factory Defaults of Coda bar Enable/Disable Codabar *Enable Coda bar Disable Coda bar Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Coda bar max length command: 020206. The parameter of this command can be set from min to 60. Coda bar min length command: 020205. The parameter of this command can be set from 2 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 02020625. Min: 02020510. 35

Transmit Start/Stop Character Transmit Start/Stop Character *Do not Transmit Start/Stop Character Coda bar Check Character No Check Char Validate and Transmit *Validate no Transmit 36

5.2.11 Code 93 Restore Factory Defaults Restore the Factory Defaults of Code 93 Enable/Disable Code 93 *Enable Code 93 Disable Code 93 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Code 93 max length command: 020D03. The parameter of this command can be set from min to 80. Code 93 min length command: 020D02. The parameter of this command can be set from 0 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 020D0325. Min: 020D0210. 37

5.2.12 GS1-128 Restore Factory Defaults Restore the Factory Defaults of GS1-128 Enable/Disable GS1-128 *Enable GS1-128 Disable GS1-128 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. GS1-128 max length command: 020B03. The parameter of this command can be set from min to 80. GS1-128 min length command: 020B02. The parameter of this command can be set from 0 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 020B0325. Min: 020B0210. 38

5.2.13 MSI Restore Factory Defaults Restore the Factory Defaults of MSI Enable/Disable MSI Enable MSI *Disable MSI Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. MSI max length command: 020E04. The parameter of this command can be set from min to 48. MSI min length command: 020E03. The parameter of this command can be set from 4 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 020E0425. Min: 020E0310. 39

MSI Check Character ValidateType10Transmit ValidateType10 ThenType11CharTransmit ValidateType10 ThenType11CharNoTransmit ValidateType10NoTransmit Validate2Type10NoTransmit Validate2Type10CharTransmit Validate2Type10CharNoTransmit *DisableMSICheck 40

5.3 2D Symbologies 5.3.1 PDF 417 Restore Factory Defaults Restore the Factory Defaults of PDF 417 Enable/Disable PDF 417 *Enable PDF 417 Disable PDF 417 Enable/Disable Micro PDF 417 *Enable Micro PDF 417 Disable Micro PDF 417 Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. PDF417 max length command: 021F06. The parameter of this command can be set from min to 2750. PDF417 min length command: 021F05. The parameter of this command can be set from to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 021F0625 Min: 021F0510. 41

5.3.2 QR Code Restore Factory Defaults Restore the Factory Defaults of QR Code Enable/Disable QR Code *Enable QR Code Disable QR Code Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. QR max length command: 023703. The parameter of this command can be set from min to 7089. QR min length command: 023702. The parameter of this command can be set from 1 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 02370325. Min: 02370210. 42

5.3.3 Data Matrix Restore Factory Defaults Restore the Factory Defaults of Data Matrix Enable/Disable Data Matrix *Enable Data Matrix Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Data Matrix max length command: 023603. The parameter of this command can be set from min to 3116. Data Matrix min length command: 023602. The parameter of this command can be set from 1 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 02360325. Min: 02360210. 43

5.3.4 Maxi code Restore Factory Defaults Restore the Factory Defaults of Maxi code Enable/Disable Maxi code Enable Maxi code *Disable Maxi code Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Maxi Code max length command: 023403. The parameter of this command can be set from min to 150. Maxi Code min length command: 023402. The parameter of this command can be set from 1 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 02340325. Min: 02340210. 44

5.3.5 Aztec Restore Factory Defaults Restore the Factory Defaults of Aztec Enable/Disable Aztec Enable Aztec *Disable Aztec Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Aztec max length command: 023306. The parameter of this command can be set from min to 3832. Aztec min length command: 023305. The parameter of this command can be set from 1 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 02330625. Min: 02330510. 45

5.3.6 Hanxin Restore Factory Defaults Restore the Factory Defaults of Hanxin Enable/Disable Hanxin Enable Hanxin *Disable Hanxin Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Hanxin max length command: 023803. The parameter of this command can be set from min to 7833. Hanxin min length command: 023802. The parameter of this command can be set from 1 to max. Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. Programming command Max: 02380325. Min: 02380210. 46

5.4 Postal Symbologies 5.4.1 China Postal Code Restore Factory Defaults Restore the Factory Defaults of China Postal Code Enable/Disable China Postal Code Enable China Postal Code *Disable China Postal Code 47

5.4.2 Telepen Restore Factory Defaults Restore the Factory Defaults of Telepen Enable/Disable Telepen Enable China Telepen *Disable China Telepen 48

6.1 Appendix 1: ASCII Table 6. Appendix Hex Dec Char 00 0 NUL (Null char.) 01 1 SOH (Start of Header) 02 2 STX (Start of Text) 03 3 ETX (End of Text) 04 4 EOT (End of Transmission) 05 5 ENQ (Enquiry) 06 6 ACK (Acknowledgment) 07 7 BEL (Bell) 08 8 BS (Backspace) 09 9 HT (Horizontal Tab) 0a 10 LF (Line Feed) 0b 11 VT (Vertical Tab) 0c 12 FF (Form Feed) 0d 13 CR (Carriage Return) 0e 14 SO (Shift Out) 0f 15 SI (Shift In) 10 16 DLE (Data Link Escape) 11 17 DC1 (XON) (Device Control 1) 12 18 DC2 (Device Control 2) 13 19 DC3 (XOFF) (Device Control 3) 14 20 DC4 (Device Control 4) 15 21 NAK (Negative Acknowledgment) 16 22 SYN (Synchronous Idle) 17 23 ETB (End of Trans. Block) 18 24 CAN (Cancel) 19 25 EM (End of Medium) 1a 26 SUB (Substitute) 1b 27 ESC (Escape) 1c 28 FS (File Separator) 1d 29 GS (Group Separator) 1e 30 RS (Request to Send) 1f 31 US (Unit Separator) 49

Hex Dec Char 20 32 SP (Space) 21 33! (Exclamation Mark) 22 34 " (Double Quote) 23 35 # (Number Sign) 24 36 $ (Dollar Sign) 25 37 % (Percent) 26 38 & (Ampersand) 27 39 ` (Single Quote) 28 40 ( (Right / Closing Parenthesis) 29 41 ) (Right / Closing Parenthesis) 2a 42 * (Asterisk) 2b 43 + (Plus) 2c 44, (Comma) 2d 45 - (Minus / Dash) 2e 46. (Dot) 2f 47 / (Forward Slash) 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3a 58 : (Colon) 3b 59 ; (Semi-colon) 3c 60 < (Less Than) 3d 61 = (Equal Sign) 3e 62 > (Greater Than) 3f 63? (Question Mark) 50

Hex Dec Char 40 64 @ (AT Symbol) 41 65 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 [ (Left / Opening Bracket) 5c 92 \ (Back Slash) 5d 93 ] (Right / Closing Bracket) 5e 94 ^ (Caret / Circumflex) 5f 95 _ (Underscore) 51

Hex Dec Char 60 96 ' (Grave Accent) 61 97 a 62 98 b 63 99 c 64 100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 { (Left/ Opening Brace) 7c 124 (Vertical Bar) 7d 125 } (Right/Closing Brace) 7e 126 ~ (Tilde) 7f 127 DEL (Delete) 52

ASCII Special Table Hex Char Hex Char Hex Char 80 F1 81 F2 82 F3 83 F4 84 F5 85 F6 86 F7 87 F8 88 F9 89 F10 8A F11 8B F12 8C L-Ctrl 8D L-Shift 8E L-Alt 8F L-GUI 90 R-Ctrl 91 R-Shift 92 R-Alt 93 R-GUI 94 Caps Lock 95 Print Screen 96 Scroll Lock 97 Pause 98 Insert 99 Delete 9A Home 9B End 9C Page Up 9D Page Down 9E Left Arrow 9F Right Arrow A0 Up Arrow A1 Down Arrow A2 Num Lock(keypad) A3 1(keypad) A4 2(keypad) A5 3(keypad) A6 4(keypad) A7 5(keypad) A8 6(keypad) A9 7(keypad) AA 8(keypad) AB 9(keypad) AC 0(keypad) AD /(keypad) AE *(keypad) AF -(keypad) B0 +(keypad) B1 Enter(keypad) B2.(keypad) B3 Insert(keypad) B4 Delete(keypad) B5 Home(keypad) B6 End(keypad) B7 Page Up(keypad) B8 Page Dn(keypad) B9 Left Arrow(keypad) BA Right Arrow(keypad) BB Up Arrow(keypad) BC Down Arrow(keypad)

6.2 Appendix 2: Digit Barcodes 0 1 2 3 4 5 6 7 8 9 A B C D E F 54

6.3 Appendix 3: Programming Command Guide Code Type Min Length Command Max Length Command Code 128 0 020A02 90 020A03 Interleaved 2 of 5 2 020403 80 020404 Matrix 2 of 5 1 020802 80 020803 Industrial 2 of 5 1 020602 48 020603 Code 39 0 020307 48 020308 CODA BAR 2 020205 60 020206 Code 93 0 020D02 80 020D03 GS1-128 0 020B02 80 020B03 MSI 4 020E03 48 020E04 PDF 417 1 021F05 2750 021F06 QR CODE 1 023702 7089 023703 Data Matrix 1 023602 3116 023603 Maxi Code 1 023402 150 023403 Aztec 1 023305 3832 023306 Hanxin 1 023802 7833 023803 Programming Command Min: ^3020A02xx. Max: ^3020A03xx. Min: ^3020403xx. Max: ^3020404xx. Min: ^3020802xx. Max: ^3m20803xx. Min: ^3020602xx. Max: ^3020603xx. Min: ^3020307xx. Max: ^3020308xx. Min: ^3020205xx. Max: ^3020206xx. Min: ^3020D02xx. Max: ^3020D03xx. Min: ^3020B02xx. Max: ^3020B03xx. Min: ^3020E03xx. Max: ^3020E04xx. Min: ^3021F05xx. Max: ^3021F06xx. Min: ^3023702xx. Max: ^3023703xxxx. Min: ^3023602xx. Max: ^3023603xxxx. Min: ^3013402xx. Max: ^3023403xxx. Min: ^3023305xx. Max: ^3023306xxxx. Min: ^3023802xx. Max: ^3023803xxxx. Remark: 1. Programming command x means the number which user would like to program the length. Example: Data Matrix code, user would like to program minimum length is 9 and maximum length is 2990. Min: ^30236029 Max: ^30236032990 2. Please use number pad to type programming command digits. 3. Programming command needs to use barcode generator to make command barcode for scanning configuration. 55