Monitoring and Telemaintenance Web-Based System

Similar documents
pco sistema... communication Technology & Evolution

Solutions for showcases and cold rooms

New generation......continuity, innovation, design

µc sistema the range T e c h n o l o g y & E v o l u t i o n

Controllers for static or ventilated refrigeration units up to 2HP. Innovative Solutions for Cold Rooms. Technology & Evolution

boss The complete range for mobile-ready local supervision

powersplit...the network evolution!

PlantVisorPRO. Plant supervision. Quick guide. Integrated Control Solutions & Energy Savings

pco sistema programmable controllers Technology & Evolution

programmable controllers pco Sistema: pco pco 5 + Programmable controller for HVAC/R applications carel.com

supernode Electronic controller for humidification Technical Leaflet Integrated Control Solutions & Energy Savings

HACCP WIRELESS RETROFIT SOLUTION

refrigeration & retail controllers solutions for compressor racks prack the advanced solution for compressor racks carel.com

refrigeration & retail controllers solutions for compressor racks prack the advanced solution for compressor racks carel.com

Protocollo Modbus sui controlli pco Modbus protocol for pco controllers

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10kVA

our experience...your solution Controlling and Monitoring Gateway

See it. Control it. The TelPro Solution

L N

High Efficiency Solutions. prack platform the complete solution for compressor racks

100% electricity. Automatic transfer switch controllers ATL series

pco5 Overview February 2010 Air Conditioning Business Unit pco5 Overview slide n. 1

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

SUPERVISION AND CONTROL FOR HYDRONIC TERMINAL UNITS

ABB Easy Instrumentation. SM Series Videographic Recorders. A clearer view of your process. High visibility process displays

GSM HOME SECURITY SYSTEM

Priva Blue ID C-Line system overview

RMS WIRELESS MINI LOGGER

Products no longer available

EC-BOS-8 Multi-protocol Web Building Controller

QuickSpecs. HP enterprise access point WL520. Overview

DEEP SEA ELECTRONICS DSE890 / DSE891 GATEWAY INSTALLATION INSTRUCTIONS

BMS Steam Station Solutions

Pour plus d'informations, veuillez nous contacter au ou à

Total Modular Data Centre Solutions

EC-BOS-8 Multi-protocol Web Building Controller

RENNERtronic Plus. higher-level controls. Made in Germany. RENNER compressor controllers. Efficient and reliable. Base load alternation switch K4 K4

PlantWatchPRO. supervisor for small-medium installations. User manual. High Efficiency Solutions

USER GUIDE M2M Point to Multipoint

nvent RAYCHEM NGC-40 SYSTEM OVERVIEW

DP 300 B and DP 600 B Series Power systems for telecom applications

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

FAN FILTER UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

3M Oldham MX 62. Presentation. Controller. Example with 64 channels. Example with 128 channels 9 U. Monitoring system for gas and flame detection 18 U

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

EAGLE Smart Wireless Solution. Condition monitoring installation has never been so easy. Brand of ACOEM

REMOTE CONTROL FOR ELECTRONIC RESIDENTIAL AND COMMERCIAL SYSTEMS

MX 62 CONTROLLER. Certifications. Better detection. Better protection. Monitoring system for gas and flame detection

UniMod Intelligent Communication for all Metering Application

Accessories / 7XV5820

Software Environments for energy management and control. Energy efficiency technology

Format 12 HS. Stirrup bending machine. the history of innovation. Stirrup bending machine.

Refrigeration solutions Controllers for commercial refrigeration, food service and catering

Evolution is a logical process!

Welcome to a world where technology flows through the heart of your business environment. Welcome to CDC

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

Product Datasheet NK8231 CEI interface for a single subsystem

PowerNetGuard INVENTORY MANAGER SOFTWARE HIGHLIGHTS. Features

PRODUCT INTRODUCTION MD8480B. W-CDMA Signalling Tester MX848001A/41A-05. GSM Frequency Hopping ANRITSU CORPORATION

Gallagher Vapour Recovery Monitoring

M I T E L 5200 IP Desktop

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

IMIO100 IMIO105. DDC controllers. Summary

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

MGate 5118 Quick Installation Guide


Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

Control systems. Efficient room control

Harrier. Controllers. Electronic Chemical Injection Rate Controllers

page A.0240 Full_Product_catalogue_ BM.indb 110

Format 16 HS Format 16 HS 3D

BUILDING AUTOMATION OF THE FUTURE

Refrigeration and Air Conditioning Controls. Technical Leaflet. Monitoring, Control and Alarm System m2 REFRIGERATION AND AIR CONDITIONING


Sentinel Dual. 3,3-10 kva. High Power 1:1 3:1 VFI TYPE. selection High quality output voltage High battery reliability Emergency function HIGHLIGHTS

SUPERVISORS & DISPLAYS

E-Seminar. Wireless LAN. Internet Technical Solution Seminar

ACE. Simplified ATM Access ACE Product Family. Unique Access Solutions

Universal UART PC-AT Adapter

About Huawei. A Global Leader of ICT Solutions

Moxa Remote Connect Gateway User s Manual

ENVIRONMENTAL MONITORING & CONTROL

LANTest. LANTest WLAN production software for use with the MT8860B. Transmit Power Levels. Transmit Spectrum Mask. Transmit Center Frequency Tolerance

HRDVS Digital Video Recorder

TECHNICAL REFERENCE MANUAL FOR CAREL CONTROLLERS

Software Installation Guide. Version 1.1

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

controller data sheet JACE 8000 PRODUCT DEFINITION

USYS Monitoring, Data Control, Acquisition and Display for Single and Multi Sensor Applications.

100% Made & Designed in Italy. IoT Gateways

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

Open Smart Metering Gateway EWIO-9180-M. Energy consumption monitoring and energy monitoring in buildings, on machines, installations and systems

Powerware 9120 UPS. Product Snapshot. Features

Lodam Condensing Unit Controller. Technical manual. Version 5.0 LOM320-LMC340

Technical System Catalogue CMC III Monitoring System

Reliable and Remote-Manageable for Large Scale M2M Deployment

Company main topic [ Product ] TracFeed DCP2. English. Multifunctional Device for Control and Protection in DC switchgear.

MEASURING AND MONITORING RELAYS

Transcription:

Monitoring and Telemaintenance Web-Based System Technology & Evolution

PlantVisor is the Carel web-server based monitoring and telemaintenance system server that features flexibility of use and easy access to information and alarm management functions. Carel has responded to the requirements for local monitoring and remote management (optimisation of maintenance, adaptation to the legislation on food safety and other standards) by supplying solutions at all levels: from controllers in the field (refrigeration and Air-Conditioning systems) to supervisory systems. In this way, the user can be constantly kept up-to-date on the status of the installation. The solutions proposed by Carel differ according to the type of installation: PlantVisor Enhanced, PC-based solution, for installations with a maximum of 200 refrigeration and air-conditioning utilities; PlantWatch, solution without requiring a PC for small refrigeration and air-conditioning installations, up to 32 utilities; PlantVisor Enhanced Remote, program for the remote management of the PlantVisor Enhanced and PlantWatch systems.... tailor-made telemaintenance solutions!

WebServer functions A Web Server is a program that can generate and serve HTML pages to be displayed by an Internet browser. All the versions of PlantVisor are web servers that can collect the data from your installation and make them available to Microsoft Internet Explorer. The information can be displayed as graphs, tables of parameters or alarms, device status indicators and so on. The numerous connection possibilities are shown to the side: 1. PlantVisor Enhanced Local can be accessed via modem using PlantVisor Enhanced Remote and/or a PC with Microsoft Internet Explorer. If PlantVisor Enhanced Local is installed on a PC in a LAN network, the information from the installation can also be accessed by other PCs on the same network. PlantVisor can also be published on the web if a permanent Internet connection is available. 2. PlantVisor Enhanced Remote manages a modem for receiving and forwarding calls to all the local installations: in this way, the data, configurations and alarms are always synchronised between the installations and the Service Centre. 3. PlantVisor can be connected remotely without requiring special software: all that is needed is a PC with a modem and Microsoft Internet Explorer. 4-5. If PlantVisor is published on the Internet, the site displaying the installation can be accessed from anywhere in the world simply using a PC or palmtop with Microsoft Internet Explorer and an Internet connection. A demo PlantVisor site is available on the Internet. Go to http://ksa.carel.com, for details on accessing this site.

Fire 4. Access to PlantVisor via Internet 1. PlantVisor on local PC in LAN network

Firewall LAN 5. Shared access to PlantVisor via Internet wall LAN 2. Service Centre with Remote PlantVisor 3. Direct connection to PlantVisor via modem

An overview of The protection of information is an important aspect: a user name and password are required to access the following pages. Each user configured has a password that defines the level of authorisation and sections that can be accessed. PlantVisor Enhanced Local summary page: all the utilities and their operating conditions are shown. Navigation menu Utilities in alarm status General installation alarm Main utility page Specific menu Main parameters Utility status Page of the graphs on the utility Quick selection of the utility On-line help always available Configuration of the graphs

PlantVisor Page for displaying and modifying the parameters of the utility Detailed information on all the parameters Main Scheduler configuration page. This is one of the more powerful PlantVisor tools, used for the correct and safe management of alarms and signal devices: fax, SMS message, activation of a relay, call to the remote PC. Selection of the alarm devices Selection of the time bands One of the pages for configuring the printouts, with time-based or manual selection PlantVisor Enhanced Remote summary page: all the installations can be easily accessed with a click of the mouse. As soon as the connection to the installation has been established, the pages can be navigated with the same ease as in PlantVisor Enhanced Local.

PlantVisor Enhanced For medium-large supermarkets (refrigeration and Air-Conditioning units), cold stores, processing rooms, seasoning rooms, the wine industry, etc.. The innovative web-based interface means that the information required can be accessed extremely easily. PlantVisor Enhanced allows: centralised management on the PC of the controller parameters, for display and modification; alarm management by scheduling the actions to be performed according to the time band (fax, SMS message, activation of a relay, call to the remote PC); sampling and recording of the temperature, humidity and pressure values and any active alarms, in compliance with the EU directive, for display or printing; adoption of Retrofit Solutions using the new acquisition modules: I/O module and wireless probes. Different levels of password protect access to the data. PlantVisor allows the connection of up to 200 Carel instruments in an RS485 serial network. PlantVisor Enhanced manages traditional and GSM modems for sending faxes, SMS messages and for remote access using PlantVisor Remote or Internet Explorer. PlantVisor Enhanced Remote PlantVisor Enhanced Remote is the program used to centralise the information from all the systems running PlantVisor Enhanced and PlantWatch. PlantVisor Enhanced Remote in fact monitors all the calls made by the local stations, receiving the configurations, the data saved and highlighting any alarm conditions. PlantVisor Enhanced Remote can be used to connect to the installations so as to modify the parameters of the local instruments or the configuration of the local PlantVisor (network, scheduler, printouts) PlantVisor Enhanced Remote can communicate with: PlantVisor Enhanced Local; PlantWatch; pco sistema controllers with modem card; Gateways. Sistema PlantVisor The PlantVisor functions have been enhanced and upgraded by the new range of accessories; as well as the sophisticated converter, the following devices can be connected: I/O modules; wireless probes.

PC Gate new new new One fundamental accessory for the operation of PlantVisor Enhanced is this innovative RS232/485 serial converter. Serial conversion from RS232 to RS485 two wire plus shield, maximum speed 19,200 baud, maximum 200 peripherals Watchdog for communication with the computer: a relay with changeover contacts is energised if there is no communication with the PC. The relay can then be connected to any 230VAC device for signalling that the supervisor functions are no longer active. RS485 line amplifier/branch: the one RS485 input and two RS485 output ports can be used to extend the line over the standard 1000 metres and/or to add branches. Consequently, the layout of the installation can be followed more simply and economically, and two modules can be connected in cascading. The converter can be installed on the desktop or mounted on a DIN rail. There are two models of converter: - one with internal key to enable the operation of PlantVisor Enhanced; - the other without internal key for use as a converter branch only. This is the model supported by the PlantVisor Free Edition.

CAREL S.p.A. Via dell Industria, 11-35020 Brugine - Padova (Italy) Tel. (+39) 0499 716611 - Fax (+39) 0499 716600 e-mail: carel@carel.com - www.carel.com Subsidiaries: CAREL Asia Pacific Ltd. rm. 11-8 F Shatin Galleria, 18 Shan Mei St., Fotan, Shatin - Hong Kong Tel. (+852) 2947 7922 - Fax (+852) 2947 7660 e-mail: sales@carelhk.com - www.carelhk.com CAREL Australia Pty Ltd PO BOX 6809, Silverwater Bus. Ctr. 1811 N.S.W. Australia Tel. (+61) 2-9748 2855 - Fax (+61) 2-9748 0626 e-mail: sales@carel.com.au - www.carel.com.au CAREL China Ltd. rm. 11-8 F Shatin Galleria, 18 Shan Mei St., Fotan, Shatin - Hong Kong Tel. (+852) 2947 7922 - Fax (+852) 2947 7660 e-mail: info@carelhk.com - www.carelhk.com CAREL Deutschland GmbH Am Spielacker, 34-63571 Gelnhausen Tel. (+49) 6051 96290 - Fax (+49) 6051 962924 e-mail: info@carel.de - www.carel.de CAREL France Sarl 32 rue du Champ Dolin - 69800 St. Priest, Rhone Tel (+33) 04 72 47 88 88 - Fax (+33) 04 78 90 08 08 e-mail: carelfrance@carelfrance.fr - www.carelfrance.fr CAREL Sud America Ltda. Avenida Dourado, 587 - Cep. 13.280-000 - Vinhedo - São Paulo (Brazil) Tel. (+55) 19 38 26 25 65 - Fax (+55) 19 38 26 25 54 e-mail: carelsudamerica@carel.com.br - www.carel.com.br CAREL U.K. Ltd. Unit 6, Windsor Park Industrial Estate 50 Windsor Avenue - Merton SW19 2TJ - London (U.K.) Tel. (+44) 208 545 2150 - Fax (+44) 208 543 8018 e-mail: careluk@careluk.co.uk - www.careluk.co.uk CAREL USA L.L.C. PO BOX 10276 Lancaster, PA 17605 Tel. (+1) 717 293 5210 Fax (+1) 717 293 0449 e-mail: sales@carelusa.com - www.carelusa.com Agency: Carel S.p.A. 2002 all rights reserved Cod. +302240381 - rel. 1.0-10/10/02 www.carel.com