BioPointe Reader Installation Guide

Similar documents
BioPointe. User's Manual

1.0 Wiring and Layout Diagrams

Akcess BioMetrics Corporation. Bio2Touch. Access Control Fingerprint Reader. User's Manual. Akcess BioMetrics Corporation

UC-2000 Installation Manual Unicorn Computers Technology Limited

MS-5000: MiniStar Reader

MS-3000 MicroStar Reader

BioPointe Finger/Card Presentation

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

PXL-250 Tiger Controller

MS-7000: SuperStar Reader

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

Installation & User Manual

Installation & User Manual V2.08

IEI emerge MicroNode Install and Setup Guide. Contents

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

QSE-CI-NWK-E Control Interface

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

SmartLock Pro INSTALLATION MANUAL

QUICK START GUIDE FOR SC 403

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

MGate 5111 Quick Installation Guide

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1

istar Pro Installation Guide

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver)

Integrity Instruments

Size of Mounting Plate /2 inches High x 7 inches Wide x 3 1/16 inches Deep (includes circuit boards)

MS-4000: ShootingStar Reader

MSS100 / MSS-VIA / MSS4 Quick Start Guide

MGate 5118 Quick Installation Guide

Quick Start Installation Guide

Zodiac Link QUICKSTART GUIDE

SmartLock Controller INSTALLATION MANUAL

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Installing the Panel. Installing the Panel

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

CA111x-series Arming Station

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01

Intelligent Devices IDI 1100 Series Technical Manual

CommLink IV Technical Guide

MGate 5105-MB-EIP Quick Installation Guide

721EX Access Controller Installation

Fingerprint Identification Proximity Reader. Quick Installation Guide

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

INNOMETRIKS INC. Rhino Quick Start Guide

IR Manager Just Add Power HD over IP Page 1 IR MANAGER. Revised

GENERAL QUICK START GUIDE

SCS100/200/400 Quick Start Guide

DESIGN GUIDE FOR INFINITY SYSTEMS

Code Dynamics, Inc. Port Splitter

WiBox 2100 Quick Start Guide

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

Contents Installation Instructions 3 Installation Diagrams System Overview Wiring Diagrams Network Diagrams

AD-300 AD-301 NETWORKED HARDWIRED LOCK USER GUIDE

Operation manual For NG BIOSINGLE Version 1.1

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

OnCell G3100 Series Quick Installation Guide

4.7 Expansion Module MAC00-FS1/FS4

Installation OVERVIEW

4.8 Expansion Module MAC00-FS1/FS4

Two Door Controller GEN-045

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

Quick Start Installation Guide

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): MAXSYS Series

I/O Interface DNA300

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

KP2000E/EM Series Style Keypad

Printer Interface (6370) Setup. Replaces discontinued Printer Interface (4370)

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

HuddleCamHD RS-232 Joystick Controller Model Number: HC-JOY

Quick Start Installation Guide

PRO3200 Professional Modular Access Control Hardware

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

AD-300 AD-301. Networked hardwired lock user guide Instructions for adaptable series networked hardwired locks

ME500A BLACK BOX SPECIFICATIONS: BOTTOM OF UNIT INTRODUCTION: CONFIGURATION: Async Sync Industrial Line Driver PWR TX RX RTS CD. DB25 Female Conn.

V-Series V30x Module Electrical, Physical Layer and Application Integration Guide

LandCell 819 GPRS Modem. GSM GPRS Serial Cellular Data Modem

Canlan INSTALLATION MANUAL

PRO2200 Professional Modular Access Control Hardware

Bewator Granta Controller Installation Handbook

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

180 Series Keypad. Handbook. Revision 2.1

Accessories IC690ACC900

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

EDS4100 Quick Start Guide

Optical Multiplexer. Quick Start Guide

HRM-0800 Instruction Manual

CV-945 Stand-Alone Biometric Reader. Installation Instructions

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

2000 Series e/em Style Keypad Installation and Programming Manual

LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER)

Select a Data Communication Interface

Serial Communication Converters & Adapters Instruction Manual

XPress DR+W Quick Start Guide

Introduction. General Ratings

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Appendix A Cable Pinouts

Industrial Serial Device Server

T1K MODBUS Base Controller Specifications

Transcription:

BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial Connection (RS232, RS485, or RS422) 3 Setting the DIP Switches (SW1, SW2, and SW3) 4 Connecting to the ADAM RS485 Converter 5 Connecting to LAN (Ethernet TCP/IP) 5 Enrolling a Master User 7 Enrolling Additional Users 8 Mounting the BioPointe Unit 8 Getting Help 8 Installation Steps Complete the following steps to install a BioPointe reader: 1. Connect the proper power. 2. Select and wire per the communication type desired. a. Serial cable from the PC to one BioPointe reader b. LAN connection to each BioPointe reader using LAN-50 devices c. RS485 connection to one or more BioPointe readers using an ADAM interface device 3. Set the DIP switches for the communication type selected. 4. Enroll a master user.* 5. Enroll additional users.* 6. Connect all BioPointe readers to Keri PXL-500W (Wiegand) controllers for door control. 7. Enroll users in the Doors program: Facility Code 0, User ID# as Card Number, Wiegand card type. 8. Perform a Total Update in the Doors program to download all user information to the Keri controllers. *Note: These steps may be performed using BioPointe Central software. Keri Systems, Inc. 1 01956-001 Rev. A

Key Parts of the BioPointe Reader The keypad is made up of the standard numeric keys, three function keys, and the ENTER and CLEAR keys. The three DIP switches are used to set the device address, communication type, and baud rate. Keri Systems, Inc. 2 01956-001 Rev. A

Cabling Requirements BioPointe RS485: Belden 9501, 24 AWG, twisted pair, shielded. BioPointe to PXL: Belden 3124A, one pair 18 AWG (power); one pair 22 AWG (data), shielded. Power Connection The BioPointe reader requires +12 to 24 VDC @ 500mA (~5w) at the reader. If the power supply is located more than 100 feet from the reader, the wire gauge you use must provide adequate power at the reader. Pin Description 1 GND 2 12 to 24 VDC PXL-500W Wiegand Controller Connection The Wiegand output from a BioPointe reader to a Keri Wiegand controller is connected as follows: Wiegand Line BioPointe Output PXL-500W TB5/TB6 W0 GND W1 Pin 9 Pin 10 Pin 11 Pin 1 Pin 4 Pin 7 Serial Connection (RS232, RS485, or RS422) A DB-9F (female) connector is required to connect the BioPointe reader directly to a PC using a serial connection. The drawings and tables below show the pin-outs for each type of serial connection. BioPointe RS-232 DB-9F Pin Pin 3 - - 4 - - 5 GND 5 6 Rx 3 7 Tx 2 8 - - RS422 and RS485 pinouts are on the next page. Keri Systems, Inc. 3 01956-001 Rev. A

Serial Connection (RS232, RS485, or RS422 Cont.) BioPointe Pin RS422 DB-9F Pin 3 Rx + 2 4 Rx - 3 5 - - 6 Tx + 4 7 Tx - 5 8 - - RS422 Connections BioPointe Pin RS485 DB-9F Pin 3 - - 4 - - 5 - - 6 D + 3 7 D - 2 8 - - RS485 Connections Setting the DIP Switches (SW1, SW2, and SW3) Note: Cycle BioPointe reader power after changing any DIP switch settings so the reader will recognize the DIP switch change. The BioPointe reader has three DIP switches: SW1 Sets the Device ID SW2 Sets the baud rate and communications type SW3 Sets the serial interface type (RS232, RS422, or RS485) SW1: 8 mini-switches to set Device ID from 1 to 254 refer to the BioPointe Device ID Addressing Table. Device ID 0 is reserved for TCP/IP LAN-50 devices. Device ID 255 is invalid. SW2: 4 mini-switches, [1,2] SW2: 4 mini-switches, [3,4] Baud Rate Communication Type Baud Rate (Bps) Switch 1 Switch 2 38400 * ON ON 19200 - ON 9600 - - 2400 ON - Comm Type Switch 3 Switch 4 RS232 * ON ON Modem ON - TCP/IP - ON RS422/485 - - SW3: 8 mini-switches Interface Type S1 S2 S3 S4 S5 S6 S7 S8 RS232 * - - - ON - ON - ON RS422 - ON ON - ON - ON - RS485 ON - ON - ON - ON - Keri Systems, Inc. 4 01956-001 Rev. A

Connecting to the ADAM RS485 Converter The ADAM 4520 is an interface adapter, connected to the serial port of a PC and converts data to RS485; you can then connect one or more BioPointe devices to the ADAM. The ADAM requires 10-30 VDC, and is configured to operate at 9600 baud. You can connect the ADAM to one, or more, BioPointe readers. ADAM Wiring Connections Connecting to LAN (Ethernet TCP/IP) The BioPointe reader may be connected to a local area network (LAN) using a Keri LAN-50 device. The LAN-50 should be assigned and addressed per the instructions in the LAN-50/LAN-500 Application Note found on the Keri CD or the Keri web site. Set the Baud rate of the LAN-50 to 38400; when the BioPointe is set for TCP/IP its baud rate defaults to 38400. The IP address assigned to the LAN-50, and port number 10001, must also be set in the BioPointe Central software by going to Tools \ Device Management System \ Device Connection Setup. Set for Ethernet, port number 10001, and the TCP/IP address of the LAN-50 to which the reader is connected, then save the configuration. Each BioPointe requires a LAN-50 unit. Keri Systems, Inc. 5 01956-001 Rev. A

Connecting to LAN (Ethernet TCP/IP Cont.) LAN-50 Wiring Connections BioPointe Pin DB-25M Pin 5 7 6 3 7 2 DIP Switch Settings SW1: Device ID Device ID 0 is reserved for TCP/IP LAN-50 devices. For LAN-50 operation, set the BioPointe Device ID to 0 per the BioPointe Device ID Addressing Table. SW2: 4 mini-switches, [1,2] SW2: 4 mini-switches, [3,4] Baud Rate Communication Type Baud Rate (Bps) Switch 1 Switch 2 38400 * ON ON 19200 - ON 9600 - - 2400 ON - SW3: 8 mini-switches Comm Type Switch 3 Switch 4 RS232 ON ON Modem ON - TCP/IP * - ON RS422/485 - - * Required Value for LAN-50 Interface Type S1 S2 S3 S4 S5 S6 S7 S8 RS232 * - - - ON - ON - ON RS422 - ON ON - ON - ON - RS485 ON - ON - ON - ON - Keri Systems, Inc. 6 01956-001 Rev. A

Enrolling a Master User When you first receive the device, there are no enrolled fingerprints. The first person to enroll becomes the first master of the device. 1. Press [Circle] [Circle] [1] The LEDs light up per the table below (refer to the Front of Unit drawing on Page 2). LED 1 LED 2 LED 3 Amber Steady ON Red Slow Blink Amber Slow Blink 2. When LED 2 starts to blink slowly in red, enter a 4-digit ID. The 4-digit ID is the User ID. When the User ID is accepted, LED 2 will blink fast in red as shown below. The fingerprint sensor will also light up signifying it is ready to read. LED 1 LED 2 LED 3 Amber Steady ON Red Fast Blink Amber Slow Blink 3. When the fingerprint sensor lights up, place your finger on it to begin the enrollment process. Each successful enrollment requires two image captures. After the first image has been successfully captured, the sensor will go off. You will then hear a series of beeps acknowledging the read. 4. When you hear the series of beeps, lift up your finger and wait for the sensor to light up a second time. Place your finger back on the sensor. If this second capture image is successful; LED 1 will blink green briefly, then return to amber. LED 1 LED 2 LED 3 Green Blink Once Amber Steady ON You can enroll up to three fingerprints for each User ID. LED 2 will blink fast in green in preparation for enrolling the next finger. Press [#] to continue, or [*] to exit. LED 1 LED 2 LED 3 Amber Steady ON Green Fast Blink Amber Slow Blink Keri Systems, Inc. 7 01956-001 Rev. A

Enrolling Additional Users To enroll additional users, start from Step 1, but press [Circle] [Circle] [2] to start enrollment. The rest of the steps are the same as those described above. However, the third LED will blink differently to indicate the different administration mode you are in. Mounting the BioPointe Unit Getting Help The Keri CD contains software and documentation for all Keri products, including the BioPointe User s Manual and BioPointe Central for Windows Software Manual. Both manuals are also available on the Keri web site. Telephone technical support is available Monday through Friday, 6 AM to 5 PM Pacific Time, at 1-800-260-5265. Keri Systems, Inc. 8 01956-001 Rev. A