Machine Safety Switches

Similar documents
Magnetic Style Safety Interlock Switches

EM-F-7G Safety Extension Module

E-Stop Safety Modules with Adjustable Delay

Machine Safety Switches

ES-TN-1H.. E-Stop Safety Modules with Fixed Delay

Models IM-T-9A and IM-T-11A Interface Modules

Banner Engineering Corp. For the latest products, information, innovations and solutions, go to bannerengineering.com

IM-T-9A and IM-T-11A Interface Modules

ES-FA-9AA and ES-FA-11AA E-Stop Safety Modules

ES-FA-9AA and ES-FA-11AA E-Stop Safety Module

ES-UA-5A and ES-VA-5A E-Stop Safety Modules

Six Input Emergency Stop Monitoring Safety Relay

UM-FA-..A Series Universal Input Safety Modules

Ten-Input Emergency Stop Safety Module

UM-FA-xA Universal Input Safety Modules

EZ-SCREEN AC Interface Box

Operating instructions. Speed monitor D / / 2014

Safety Mats & Area Guarding

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

SLM Series Slot Sensors

Operating instructions Safety sensor BNS About this document. Content

5504 Thermocouple Analog Input Module

Compact Coded Magnetic Safety Interlock Switch and Control Units

L-GAGE Q50 Series with Analog Output

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)

Operating instructions. Standstill monitor A / / 2011

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

SAFETY LOCKING DEVICES

MINI-BEAM SM2A312F. MINI-BEAM Glass Fiber Optic. Output Type E X C 100 E S S. A I N 1.01 m.033 ft. SPST Solid-state 2-wire E X E S S

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

New! Optical Safety Systems

DF-G2 High Speed Expert Dual Display Small Object Counter

Q08 Series Opposed-Mode Sensors

Magnetically Actuated Safety Interlock Switches

Operating instructions Safety sensor BNS About this document. Content

OptoFence. OptoFence OF OF safety light curtains. Description

Operating Instructions. Isolation Relay for Switches Model: RL manual_rl-6100_1116

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

onlinecomponents.com

QAL50 Series Analog Line Sensor

MAXIMA+ Series Rotary Level Indicator

MINI-BEAM SM312F. MINI-BEAM Glass Fiber Optic. Output Type E X C E S S. A I N 1.01 m.033 ft. Bipolar NPN/PNP V dc E X.

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

ZC Series Zone Monitoring Controllers

Operating Instructions. For. Level Control Module. Model SSR 1000

DUO-TOUCH Modules mm mm. AT-..M-2A Models (AT-FM-2A Module shown)

SSA-EB Series Emergency Stop Push Buttons

MAXIMA + Series ROTARY LEVEL CONTROL

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

MSR178DP. Description. Features. Specifications

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

MT8050iE series. Installation Instruction (1) (2)

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Operating Instructions

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

CarSense202 O P E R A T I N G I N S T R U C T I O N S V E HI C L E M O T I O N D E T E C T O R Johnston Parkway, Cleveland, Ohio 44128

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length (overall length) material

Operating Instructions Differential Pressure Transducer PS27

EZ-LIGHT K50 & K80 Series Pick-to-Light Sensors

WORLD BEAM QS18LLP Series

Hinged safety switches, Palladio line

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

Tempco Instruction Manual

PSR DC/ESP4/2X1/1X2

Operating instructions Evaluation system for flow sensors VS / / 2013

8000 Series: Installation Supplement R2-1-12

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

C-POWER AC AUTOMATIC CONTROL

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Model 7705 Control Module

Diffuse reflection light scanner with background suppression. Dimensioned drawing

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Operating instructions AC010S Compact AS-i E-STOP safety module

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

USER MANUAL. WBI412F41 AC current transducer

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Magnetically Actuated Safety Interlock Switches

ivu TG Gen2 Image Sensor with Integrated Display

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Transcription:

Machine Safety Switches Style SI-MAG Series ic Style Switch Features Non-contact safety switches are the best choice for washdown applications; the switch components are sealed and rated NEMA 4X, IEC IP67 Tolerant of dirt buildup, sensing distance, and alignment System consists of three components: - Coded magnet - Reed switch sensor - Controller module contains several differently-polarized magnets, and sensor contains pole-stable reed contacts to minimize any possibility of defeat Easy installation; can be concealed for added defeat resistance reed switches provide diverse input to the controller module ic Style Safety Switch Models * Coded Controller Cable Switching Distance Min. ON Max OFF SI-MAG1SM SI-MAG1SMCO SI-MAG1MM SI-MAG1MMHF 3 mm 8 mm (0.31") 14 mm (0.55") 16 mm (0.63") SI-MAG2SM SI-MAG2MM SI-MAG1C 3 m (10 ft) 4 mm (0.16") 8 mm (0.32") SI-MAG3SM SI-MAG3MM 3 mm 7 mm (0.28" ) *NOTES: 9 m (30') cables are available for magnet sensors by adding suffix W/30 to the model number of the cabled version (e.g., SI-MAG1SM w/30). Cable Opposite Printed in USA 10/02 P/N 49376 rev. B

Machine Safety Switches Style! Important Information Regarding the Use of Safety Switches In the United States, the functions that Banner safety switches are intended to perform are regulated by the Occupational Safety and Health Administration (OSHA). Whether or not any particular safety switch installation meets all applicable OSHA requirements depends upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the safety switches are applied, installed, wired, operated, and maintained. Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenance instructions. This information is found in the instruction manual packaged with each safety switch. In addition, we suggest that any questions regarding the use or installation of safety switches be directed to the factory applications department at the telephone numbers or address shown, below. Banner Engineering Corp. recommends that safety switches be applied according to the guidelines set forth in international (ISO/IEC) standards listed, below. Specifically, Banner Engineering Corp. recommends application of safety switches in a configuration which meets safety category 4, per ISO 13849 (EN954-1). In addition, the user of Banner safety switches has the responsibility to ensure that all local, state, and national laws, rules, codes, and regulations relating to the use of Banner safety switches in any particular application are satisfied. Extreme care is urged that all legal requirements have been met and that all installations and maintenance instructions are followed. Application Assistance Toll Free: 1-888-3-SENSOR (1-888-373-6767) Email: sensors@bannerengineering.com Address: 9714 Tenth Avenue North Minneapolis, MN 55441 U.S. Regulations Applicable to Use of Banner Safety Switches OSHA Code of Federal Regulations: Title 29, Parts 1900 to 1910 Available from: Superintendent of Documents Government Printing Office P.O. Box 371954 Pittsburgh, PA 15250-7954 Tel: 202-512-1800 U.S. Standards Applicable to Use of Banner Safety Switches ANSI B11 Standards for Construction, Care, and Use of Machine Tools Available from: Safety Director AMT - The Association for Manufacturing Technology 7901 Westpark Drive McLean, VA 22102 Tel: 703-893-2900 Applicable European and International Standards ISO/TR 12100-1 Safety of Machinery - Basic Concepts, General Principles for Design (EN292-18-2) ISO 13852 (EN 294) Safety of Machinery - Safety Distances to Prevent Danger Zones Being Reached by the Upper Limbs ISO 13853 (EN 811) Safety of Machinery - Safety Distances to Prevent Danger Zones Being Reached by the Lower Limbs ISO 13849 (EN 954-1) Safety of Machinery - Safety Related Parts of Control Systems ISO 13855 (EN 999) Safety of Machinery - The Positioning of Protective Equipment in Respect to Approach Speeds of Parts of the Human Body ISO 14119 (EN 1088) Safety of Machinery - Interlocking Devices Associated with Guards - Principles for Design and Selection IEC/EN 60204-1 Safety of Machinery - Electrical Equipment of Machines IEC/EN 60947-5-1 Low Voltage Switchgear -Electromechanical Control Circuit Devices Available from: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 Phone: 1-800-854-7179 Fax: 303-397-2740 page 2

Machine Safety Switches Style and Installation ic style safety switches are easily mounted on the inside edge of most guards. Inside mounting can often hide them from view and discourage tampering. All mounting hardware is supplied by the user. Use of permanent fasteners or locking hardware is recommended to prevent loosening or displacement of the actuator and switch body. Mounting holes in the magnet and sensor accept M4 (#6) hardware (see drawings, on page 8). WARNING! It must not be possible for! personnel to reach any hazard point through an opened guard (or any opening) before hazardous machine motion has completely stopped. Please reference OSHA CFR 1910.217 and ANSI B11 standards (see page 2) for information on determining safety distances and safe opening sizes for your guarding devices. Position the magnet and sensor in the mounting location with the magnet surface directly opposite the sensing surface (see dimension drawings). Leave a slight gap (up to 3 mm or 0.12") between the magnet and sensor surfaces, so that the magnet and sensor do not act as an end stop when the guard is closed. Mark the mounting holes. Fasten the magnet and sensor in place. After the mounting hardware is secure, check the magnet and sensor alignment and sensing gap. Neither is critical, but the gap should be less than 3 mm for reliable sensor actuation. Route the sensor cable to the controller location. The controller must be installed inside an enclosure. It is not designed for exposed wiring. It is the user s responsibility to house the controller in an enclosure with NEMA (or IEC) rating which is suitable for the operating environment. The controller mounts onto standard 35 mm DIN rail. Note: The typical direction of approach of a magnet to its corresponding sensor is normally perpendicular to the sensing face and the magnet surface (see dimensional drawings on page 8 and Figures 2a, 2b and 2c, Approach on page 6). Alternate directions are possible (e.g., sideways or parallel), though the speed of approach must be fast enough to meet the simultaneity-monitoring period of 0.5 seconds. This speed is approximately equal to or greater than 0.2 m (8"/s). If the simultaneity is not met, the MAG1C controller will not close its safety output contacts, even if the sensor indicator is OFF. IMPORTANT NOTE: If the sensor or magnet is mounted on a material that can be magnetized (e.g., ferrous metal, such as iron), the switching distance will be affected. The sensor and magnet must be mounted a minimum distance of 15 mm (0.6") from magnetized or ferrous materials for proper operation. IMPORTANT NOTE: The magnet and sensor are coded to minimize the possibility of false actuation. Nevertheless, they should not be used within known fields of highlevel electromagnetic radiation. The magnet and sensor must never be used as a mechanical stop. Electrical Installation Each controller is powered by 24V dc (at less than 100 ma). The controller, in turn, supplies power to the sensor. As illustrated in Figure 1, the safety output (terminals 71 and 76) from each of two safety switches per interlock guard must connect to a 2-channel safety module or safety interface in order to achieve a control reliable interface to the master stop control elements of a machine. Examples of appropriate safety modules include 2-channel emergency stop (E-stop) safety modules and gate monitor safety modules. Two functions of the safety module or safety interface are: 1) to provide a means of monitoring the contacts of both safety switches for contact failure, and to prevent the machine from restarting if either switch fails; page 3

Machine Safety Switches Style Coded Coded Single gate or guard blue gray brown black blue gray brown black 1.2 1.3 80 1.1 1.4 81 SI-MAG1C + 24V dc - 1.2 1.3 80 1.1 1.4 81 SI-MAG1C + 24V dc - Note: Blue and Gray wires are interchangeable. Brown and Black wires are interchangeable. Note: The contact between terminals 91 and 94 is a non-safety auxiliary monitor contact which is open when K1 and K2 are both closed K1 K2 K1 K2 Note: The contact between terminals 71 and 76 is the safety rated output. The user must refer to the SI-MAG1C manual for recommended wiring. 60 61 94 91 76 71 60 61 94 91 76 71 Connect terminal 60 to 61 with a jumper wire. Input Channel #1 2-channel Safety Module (2-channel E-stop Module 2-channel Gate Monitor Module, etc.) Input Channel #2 NOTE: Refer to the installation instructions provided with the safety module for information regarding the interface of the safety module to the machine stop control elements. IMPORTANT NOTE: Be certain that all wiring conforms to all relevant wiring codes.! CAUTION! Control Reliability... Two safety switches must be used per interlock guard to achieve control reliability of a machine stop circuit. Use of only one safety switch per interlock guard is not recommended. In addition, normally-closed safety contacts from each of the two safety switches must be individually connected to the two separate inputs of a 2-channel safety module or safety interface, as illustrated in Figure 1. This is required to provide monitoring for safety switch contact failure, and to provide the necessary reset routine, as required by ANSI B11 and NFPA 79 machine safety standards.! CAUTION! Connection of Multiple Safety Switches to one Safety Module Input Channel... To meet control reliability, never connect more than one safety switch contact to one input channel of a safety module or safety interface. To do so defeats the ability of the safety module to monitor each contact for failure, and results in a machine stop control circuit which is not control reliable. Figure 1. Connect two redundant safety switches per interlock guard to an appropriate 2-channel input safety module. page 4

Machine Safety Switches Style 2) to provide a reset routine after closing the guard and returning the safety contacts to their closed position - this prevents the controlled machinery from restarting by simply reinserting the safety switch actuators. This necessary reset function is required by ANSI B11 and NFPA 79 machine safety standards. Use only the safety output between terminals 71 and 76 of the MAG1C controllers for inputs to the safety module or safety interface (see Figure 1). The auxiliary contact between terminals 91 and 94 is not safety-rated and should only be used for monitoring functions, such as to communicate with a process controller or PLC. In normal operation, the output of the auxiliary contact is opposite of the safety output. Terminals 60 and 61 are External Device Monitoring (EDM) inputs and must be connected to normally-closed forced-guided monitor contacts of the machine stop control elements or jumpered if the monitoring of these elements is accomplished by other means, such as by the safety module or safety interface. Refer to the installation instructions provided with the safety module for more information regarding the interfacing of the safety module to the machine stop control elements. Periodic Checks We recommend that safety switches be checked at each shift change or machine setup by a designated person for: 1) Breakage of the sensor or magnet, 2) Good alignment of the magnet with the sensor, 3) Confirmation that the sensor and magnet are not being used as an end stop, 4) Loosening of the sensor or magnet mounting hardware. 5) Verify that it is not possible to reach any hazard point through an opened guard (or any opening) before hazardous machine motion has completely stopped. In addition, we recommend that a qualified person check for the following on a periodic schedule determined by the user based upon the severity of the operating environment and the frequency of switch actuations: 1) Inspect the electrical wiring for continuity and damage. 2) Check to be certain that wiring conforms to the instructions given on pages 3 and 4 of this installation manual. A designated person is identified in writing by the employer as being appropriately trained to perform a specified checkout procedure. A qualified person possesses a recognized degree or certificate or has extensive knowledge, training, and experience to be able to solve problems relating to the safety switch installation (ANSI B30.2). Repairs NOTE: Do not attempt any repairs to the switch. It contains no field-replaceable components. Return the switch to the factory for warranty repair or replacement. If it ever becomes necessary to return a switch to the factory, please do the following: 1) Contact the Banner applications engineering department at the number or address listed on the front cover. They will attempt to troubleshoot the system from your description of the problem. If they conclude that a component is defective, they will issue an RMA (Return Merchandise Authorization) number for your paperwork, and give you the proper shipping address. 2) Pack the switch carefully. Damage which occurs in shipping is not covered by warranty. page 5

Machine Safety Switches Style Approach options for sensor/magnet pairs Normal Approach movement is perpendicular to the Incorrect Approach Label to label approach of sensor and magnet is not possible Normal Approach movement is perpendicular to the Sensing face Important! The magnet mounting holes must be oriented as shown, relative to the sensor cable position. Alternate Approach movement is parallel to the Incorrect Approach 90º approach of sensor and magnet is not possible Alternate Approach movement is parallel to the Figure 2a. Approach for SI-MAG1xx sensor/magnet pairs Important! The magnet mounting holes must be oriented as shown, relative to the sensor cable position. Normal Approach movement is perpendicular to the Incorrect Approach Label to label approach of sensor and magnet is not possible Incorrect Orientation Figure 2c. Approach for SI-MAG3xx sensor/magnet pairs Alternate Approach movement is parallel to the Incorrect Approach 90º approach of sensor and magnet is not possible NOTE: For all magnet style switches, approach speed must be greater than 0.2 m/s to allow for proper switching. Figure 2b. Approach for SI-MAG2xx sensor/magnet pairs page 6

Switching Elements Three pole-stable reed switches Repeat Switching Accuracy ±0.1 mm (±0.004") Machine Safety Switches Style Style Specifications Construction Epoxy-encapsulated circuit in polyamide housing Environmental Rating IEC IP67 Switching Capacity 30V dc max @0.25W Operating Temperature -5 to +70 C (+23 to +158 F) Connections Integral PVC-jacketed 3 m (10') 4-wire cable. Cable O.D. is 5 mm (0.2"). Wires are 24 AWG (0.25 mm 2 ). Supply Voltage and Current Compatibility All magnet sensor models listed on page 1 Output Configuration Style Controller Specifications 24V dc ±15% (15% maximum ripple) at less than 100mA Two series-connected (redundant) normally-open safety relay contacts Contact Material: silver-nickel alloy Contact Ratings: Maximum Voltage: 250V ac Maximum Current: 8A ac Maximum Power: 1700VA Mechanical Life: 1,000,000 operations Electrical Life: 100,000 operations at full resistive load NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across load. Never install suppressors across output contacts Auxiliary Non-safety Monitor Contact Simultaneity - Monitoring Period Status Indicators Housing Mounting Wire Connections Maximum Voltage: 120V ac, 24V dc Maximum Current: 0.25A (ac), 1.0 A (dc) The inputs from the sensor (terminals 1.1/1.2 and 1.3/1.4) must switch within 0.5 seconds of each other Green - Power ON Red - / out of position or open circuit in sensor wiring Polycarbonate; Rated NEMA 1, IEC IP20 Mounts to standard 35 mm DIN rail track. Must be installed inside an enclosure rated NEMA 3, IEC IP54 or better. Screw terminals with pressure plates accept wire size: 0.2 mm 2 (26 AWG) min. to 2.5 mm 2 (12 AWG) max. Operating Temperature 0 to +55 C (+32 to +131 F) Dimensions See drawing on page 8. Certifications page 7

Machine Safety Switches Style 88 mm (3.5") (0.18") (3) 78 mm (3.1") 6.5 mm (0.26") 68 mm (2.7") 25 mm 10.7 mm (0.42") 7.2 mm (0.28") 2.5 mm (0.10") Sensing 3.0 mm 88 mm (3.5") 78 mm (3.1") 68 mm (2.7") (0.18") (3) 6.5 mm (0.26") 25 mm Sensing 2.5 mm (0.10") 7.2 mm (0.28") 10.7 mm (0.42") 3.0 mm 88 mm (3.5") 78 mm (3.1") 6.5 mm (0.26") (0.18") (3) 68 mm (2.7") 25 mm 10.7 mm (0.42") 7.2 mm (0.28") 2.5 mm (0.10") 3.0 mm Figure 3a.SI-MAG1SM dimensions Figure 3b.SI-MAG1SMCO dimensions Figure 3c. SI-MAG1MM dimensions Sensing 7 mm (0.3") 26 mm ø 8.3 mm (0.33") (2) 7 mm (0.3") 26 mm (1.0 in) ø 8.3 mm (0.33") (2) 22 mm (0.9") 29 mm (1.1") 43 mm (1.7") ø 4.3 mm (0.17") (2) (0.18") 22 mm (0.9") 29 mm (1.1") 43 mm (1.7") ø 4.3 mm (0.17") (2) (0.18") Figure 4a.SI-MAG2SM dimensions Figure 4b.SI-MAG2MM dimensions Sensing 35 mm (1.4") 34 mm (1.3") 10.5 mm (0.4") (0.2") 2 mm (0.1") M30 x 1.5 mm 27.5 mm (1.1") ø 35 mm (1.4") 5.2 mm (0.2") SW36 9 mm (0.4") 15 mm (0.6") 25 mm 35 mm (1.4") Figure 5a.SI-MAG3SM dimensions Figure 5b.SI-MAG3MM dimensions! 75.0 mm (2.95") 22.5 mm (0.89") 98.5 mm (3.88") WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. Figure 6. SI-MAG1C Controller dimensions Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 Phone: 763.544.3164 Toll-free: 888.373.6767 www.bannerengineering.com