Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Similar documents
Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

US 5,634,357 D 385,7683 Bulletin: A21S4

US 5,634,357 D 385,7683 Bulletin: A28S4

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Heavy Duty Disconnects US 5,634,357 D 385,7683 BULLETIN: A28S4

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects

Standard Product One-Door Enclosures. Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

Free-Stand Disconnects and Accessories

See also Accessories. Industrial Corrosion Inhibitors Floor Stand Kit PANELITE Enclosure Lights Overview Bulletin: A28X1, A28X2, A28XM.

UL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E CSA File No : Type 12

SEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.

Type 4 Disconnect Enclosures

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.

Type 4X S.S. Disconnect Enclosures

Fiberglass. Spec L. Non-Metallic. Hinge-Cover with 3-Point Latch or Quick-Release Latches, Type 4X

Arc Flash Safety Systems INDEX. Safety Systems. Arc Flash AF-8

Disconnect Enclosures

Free-Standing Type 12 Enclosures

151 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST

CONCEPT Stainless Steel Wall-Mount Enclosures

TYPE 4/12 PREMIER SERIES

Polycarbonate and ABS QLINE E

Panel Enclosures. Wall-Mount Enclosures Type 12 Premier Series Double-Door with Quarter-Turn Latches Data Sheet

Standard Product Left-Hinged

INTERSAFE Data Interface Ports are mounted on an enclosure to allow programming access to devices inside without opening the enclosure door.

INTERSAFE DATA INTERFACE PORTS, TYPE 4/4X/12

Standard Product Left-Hinged

Polycarbonate and ABS QLINE D

Polycarbonate and ABS QLINE E

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

Featured Products - RU Marking Standard on Hoffman brand

Polycarbonate and ABS QLINE D

Standard Product. Catalog Number. Width. Depth. mm 18 = = = = = = = = 400

3630P Encl 34X28 Enclosure Panel. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions

Mounting Options. Maintains NEMA Type 12 and IEC IP55 enclosure rating when properly installed per Hoffman instructions.

1510 MOTOR CONTROLLERS

Technical Operating Information AC Unit (T150116G100) Replacement Filter No

Disconnect Enclosures

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

SECTION SWITCHBOARDS

Technical Operating Information AC Unit (T150116G100) Replacement Filter No Wall-Mount Cabinets

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom

Ex-CELL Stainless Steel and Painted Steel Enclosures

CHAPTER 3. Intro Page POLYPRO ULTRX QLINE D

PANELITE ENCLOSURE LIGHTS OVERVIEW

Shelves, Keyboard Trays and Gland Plates Folding Shelves

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

NEMA Enclosure Solutions for Cisco WLAN Deployments

Industrial Modular Enclosures

SECTION PANELBOARDS

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389

FS66S Global Free-Stand Single and Dual Access, Type 4X

PROLINE ExtERNaL COmPONENts 0-mm solid BasE Catalog Number Fits Frame B x C W (mm) W (in.) D (mm) D (in.) PB045 PB046 PB064 PB064HF2 PB065HF2 PB066

INDUSTRIAL MODULAR ENCLOSURES EQUIPMENT PROTECTION

SECTION SWITCHGEAR

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

PowerFlex 750-Series Power Option Cabinets

Jockey Pump Controllers

Jockey Pump Controllers

Stainless Steel Hatch Fasteners Page

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

194E FA 32 E P11 P11 6

Maintains NEMA Type 12 and IEC IP55 enclosure rating when properly installed per Hoffman instructions.

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

PENDANT PUSHBUTTON STATIONS

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

FTTX Fiber Optic Cabinet Packages Priority Electronics USA

Argenta W A L L M O U N T I N G M E T A L C A B I N E T S

ROLLING COUNTER SHUTTERS

194E FA 32 E P11 P11 6

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Product Description. Construction. Finish. Industry Standards

PanelView Plus/VersaView CE Terminals and Display Modules

IP Enclosures Product Overview 2015

VERAK IP. 19 Stand Alone Cabinet with IP65 Rating.

Machine Safety. Products

WIRE AND CABLE MANAGEMENT

Metal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak

KM6-II Subracks. APW Electronic Solutions. 152 APW Electronic Solutions Toll Free (800) Fax: (858)

DC Outdoor Power Supply/Chargers

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)

EJB Junction Boxes Dimensions Pg. 132

CS7 Industrial Control Relays

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Brasch Washdown Unit Heaters

Vertiv VR Rack 1.0 GENERAL

Allen-Bradley Bulletin 100 Contactors

920 Remote Control (RC) Switches

Transcription:

763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E61997 NEMA Type 12 CSA File No. 42186: Type 12 IEC 60529, IP55 APPLICATION Modular disconnect enclosures provide configuration flexibility and versatility. One- and two-door models can be bolted together in any configuration. Slave enclosures can be added or removed as required. FEATUreS One-Door Enclosure (left side open): Universal cutout on right flange provides mounting for most disconnect operators by using operator adapters. Right side is closed since disconnect operator cannot be obscured by a door. Master door is hinged on left. Defeater on master door requires a screwdriver to open. Master door activates mechanical interlock which prevents slave doors from being opened first. Doors may be closed in any order. Interlock is furnished. Two-Door Enclosure (left side open): Universal cutout on right flange provides mounting for most disconnect operators by using operator adapters. Right side is closed. Master door is right-hand door. Both doors hinged on left. Defeater on master door requires a screwdriver to open. Master door activates mechanical interlock which prevents slave doors from being opened first. Doors may be closed in any order. Removable centerpost permits easy panel installation. Interlock is furnished. One-Door Slave Enclosure (both sides open): Door hinged on left. Interlock is furnished. Two-Door Slave Enclosure (both sides open): Right-hand door hinged on right and left-hand door hinged on left. Removable centerpost permits easy panel installation. Interlock is furnished. SPECIFICATIONS.121-in. steel Seams are continuously welded and ground smooth Body stiffeners in larger enclosures for extra rigidity Body flange trough excludes liquids and contaminants Heavy-duty lifting eyes anchor into reinforced top Concealed, easy-to-remove hinges Heavy-duty 3-point latching mechanism operated by padlocking handle on all doors Rollers on ends of latch rods for easier door closing Data pocket is high-impact thermoplastic Oil-resistant door gasket Panel supports Removable.127-in. thick steel panels mount on collar studs Bonding provision on door Mechanical interlock standard on each enclosure; parts required to connect interlock system between adjacent enclosures are provided Interlock rods are furnished with enclosures; gasket kits and end plate purchased separately Models available with panel include painted panel; conductive panel sold separately FINISH ANSI 61 gray finish inside and outside over pretreated surfaces. Panels have white or conductive finish. Flat end plates are ANSI 61 gray inside and outside. ACCESSORIES See also Accessories. Blank Adapter Plates, Mild Steel End Plates PANELITE Enclosure Lights Overview Operator Adapters for Universal Cutouts Panels for Type 3R, 4, 4X, 12 and 13 Enclosures Center Panel Supports MODIFICATION and CUSTOMIZation Hoffman excels at modifying and customizing products to your specifications. Contact your local Hoffman sales office or distributor for complete information. Bulletin: A34 1 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Standard Product Master Modular Type 12 Enclosures for Flange-Mount s, One-Door (left side open) Panel Size D x E Catalog Number AxBxC in./mm With or Without Panel Panel Conductive Panel in./mm AMOD72X4018FTC 72.12 x 40.25 x 18.12 1832 x 1020 x 460 With A72PM40 A72PM40G 60.00 x 33.75 1524 x 857 AMOD72X4018FTCLP 72.12 x 40.25 x 18.12 1832 x 1022 x 460 Without AMOD84X4018FTC 84.12 x 40.25 x 18.12 2137 x 1020 x 460 With A84PM40 A84PM40G 72.00 x 33.75 1829 x 857 AMOD84X4018FTCLP 84.12 x 40.25 x 18.12 2137 x 1022 x 460 Without AMOD84X4024FTC 84.12 x 40.25 x 24.12 2137 x 1020 x 613 With A84PM40 A84PM40G 72.00 x 33.75 1829 x 857 AMOD84X4024FTCLP 84.12 x 40.25 x 24.12 2137 x 1022 x 613 Without All 24.12-in. (613-mm) and deeper enclosures using short connecting rods in the following models require a Hoffman platform assembly, catalog number ADSCPA, purchased separately. ABB Controls flange-operated devices Cutler-Hammer C361 devices Cutler-Hammer C371 mechanisms which use C371E, F, G, K operating mechanism General Electric Type TDA devices (see next paragraph for option) Square D Class 9422 devices (see next paragraph for option) The platform assembly can be omitted if long connecting rods are ordered in place of short connecting rods. For Cutler-Hammer operating mechanisms C371E and C371F order catalog number C371CS1 connecting rod. For C371G and C371K order catalog number C371CS2. For General Electric devices, order catalog number TDSR extended length drive rod For Square D devices, order catalog number 9422-R2 extra long operating rod(s). Some devices require two rods. Consult factory for space occupied on panel when platform is used. Enclosures with panel include a painted panel. Order conductive panels separately. EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.422.2600 HOFFMANONLINE.COM 2

Standard Product Master Modular Type 12 Enclosures for Flange-Mount s, Two-Door (left side open) Panel Size D x E Catalog Number AxBxC in./mm With or Without Panel Panel Conductive Panel in./mm AMOD72X7818FTC 72.12 x 78.50 x 18.12 1832 x 1994 x 460 With A72PM78 A72PM78G 60.00 x 72.00 1524 x 1829 AMOD72X7818FTCLP 72.12 x 78.50 x 18.12 1832 x 1994 x 460 Without AMOD84X7818FTC 84.12 x 78.50 x 18.12 2137 x 1994 x 460 With A84PM78 A84PM78G 72.00 x 72.00 1829 x 1829 AMOD84X7818FTCLP 84.12 x 78.50 x 18.12 2137 x 1994 x 460 Without AMOD84X7824FTC 84.12 x 78.50 x 24.12 2137 x 1994 x 613 With A84PM78 A84PM78G 72.00 x 72.00 1829 x 1829 AMOD84X7824FTCLP 84.12 x 78.50 x 24.12 2137 x 1994 x 613 Without Enclosures with panel include a painted panel. Order conductive panels separately. 3 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Standard Product Slave Modular Type 12 Enclosures for Flange-Mount s, One-Door (both sides open) Panel Size D x E Catalog Number AxBxC in./mm With or Without Panel Panel Conductive Panel in./mm AMOD723918FTC 72.12 x 39.75 x 18.12 1832 x 1010 x 460 With A72PM40 A72PM40G 60.00 x 33.75 1524 x 857 AMOD723918FTCLP 72.12 x 39.75 x 18.12 1832 x 1010 x 460 Without AMOD843918FTC 84.12 x 39.75 x 18.12 2137 x 1010 x 460 With A84PM40 A84PM40G 72.00 x 33.75 1829 x 857 AMOD843918FTCLP 84.12 x 39.75 x 18.12 2137 x 1010 x 460 Without AMOD843924FTC 84.12 x 39.75 x 24.12 2137 x 1010 x 613 With A84PM40 A84PM40G 72.00 x 33.75 1829 x 857 AMOD843924FTCLP 84.12 x 39.75 x 24.12 2137 x 1010 x 613 Without Enclosures with panel include a painted panel. Order conductive panels separately. C2525-C EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.422.2600 HOFFMANONLINE.COM 4

Standard Product Slave Modular Type 12 Enclosures for Flange-Mount s, Two-Door (both sides open) Panel Size D x E Catalog Number AxBxC in./mm With or Without Panel Panel Conductive Panel in./mm AMOD727718FTC 72.12 x 78.00 x 18.12 1832 x 1981 x 460 With A72PM78 A72PM78G 60.00 x 72.00 1524 x 1829 AMOD727718FTCLP 72.12 x 78.00 x 18.12 1832 x 1981 x 460 Without AMOD847718FTC 84.12 x 78.00 x 18.12 2137 x 1981 x 460 With A84PM78 A84PM78G 72.00 x 72.00 1829 x 1829 AMOD847718FTCLP 84.12 x 78.00 x 18.12 2137 x 1981 x 460 Without AMOD847724FTC 84.12 x 78.00 x 24.12 2137 x 1981 x 613 With A84PM78 A84PM78G 72.00 x 72.00 1829 x 1829 AMOD847724FTCLP 84.12 x 78.00 x 24.12 2137 x 1981 x 613 Without Enclosures with panel include a painted panel. Order conductive panels separately. 5 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Mounting Space s are located by dimension E1. Wiring space W1 is available when disconnect is installed in the enclosure. See Technical Information section for E1 Spacing by Enclosure Height for various disconnect switch manufacturers. W1 = Wiring Space. See Technical Information section for wire bend space. Refer to national electrical Code, 2005 article 430-10(b) for wiring space required for line side conductors to be connected to disconnect. Verify your application to determine whether wiring space is adequate. Consult Space Occupied by drawing to determine whether the disconnect device you are using will fit the enclosure size you have selected. EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.422.2600 HOFFMANONLINE.COM 6

End Plates Used to seal open end(s) of an assembly of modular enclosures. The 2.50-in. deep End Plates allow extra wiring space. Gasket and mounting bolts are included. Bulletin: A34Y Catalog Number AxC in./mm AMOD72EPT 72.12 x 18.12 1832 x 460 AMOD84EPT 84.12 x 18.12 2137 x 460 AMOD8424EPT 84.12 x 24.12 2137 x 613 Flat End Plates Used to seal open end(s) of an assembly of modular enclosures. The Flat End Plate provides a low profile cover for the open end of a modular enclosure. Studs welded to the end plate eliminate bolt holes. Gasket and mounting hardware are furnished. Bulletin: A34Y Catalog Number AxC in./mm AMOD7218FEP 72.12 x 18.12 1832 x 460 AMOD8418FEP 84.12 x 18.12 2137 x 460 AMOD8424FEP 84.12 x 24.12 2137 x 613 7 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Barriers Used to provide a barrier between individual enclosures in an assembly of modular enclosures. The flat plate is gasketed on both sides and inserted between two modular enclosures. Bolts and instructions are included. Bulletin: A34Y Catalog Number AxC in./mm AMOD7218BAP 72.12 x 18.12 1832 x 460 AMOD8418BAP 84.12 x 18.12 2137 x 460 AMOD8424BAP 84.12 x 24.12 2137 x 613 Gasket Kit Used to maintain enclosure rating when modular enclosures are joined together; includes a one-piece gasket, bolts and instructions. Bulletin: A34Y Catalog Number AxC in./mm AMOD7218FGK 72.12 x 18.12 1832 x 460 AMOD8418FGK 84.12 x 18.12 2137 x 460 AMOD8424FGK 84.12 x 24.12 2137 x 613 EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.422.2600 HOFFMANONLINE.COM 8

Free-Stand Universal-Cutout s Free-Stand Universal-Cutout Overview Free-Stand Universal-Cutout Overview Universal Cutout Overview Bulletin 140U flexible cable operating mechanisms for 140U molded case circuit breakers Bulletin 140G flexible cable and variable depth flange-mount molded case circuit breakers Bulletin 1494C cable-operated disconnect switches with flangemount handles Bulletin 194RC cable-operated flange-mount handles for use with the NFPA 79 compliant 194R IEC rotary disconnect switches ABB Controls flange-mount variable-depth operating mechanisms for disconnect switches and circuit breakers. Also the cable version for circuit breakers. Eaton Cutler-Hammer Type C361 disconnect switches and operator mechanisms, and Type C371 circuit breakers and circuit breaker operating mechanisms. Also Type SM safety handle mechanisms and FLEX SHAFT handle operators for circuit breakers. General Electric Type STDA flange handles and variable-depth operating mechanisms for disconnect switches and circuit breakers. Also SPECTRAFLEX cable operators for circuit breakers. Siemens ite MAX FLEX flange-mount variable-depth operating handles for disconnect switches and circuit breakers. Schneider Square D disconnect switches and circuit breakers used with Class 9422 flange-mount variable-depth operating mechanisms or cable mechanisms. These enclosures will NOT receive Class 9422 bracket-mount disconnect devices, Class 9422TG1 or TG2 devices. Enclosures with Universal Cutout Universal cutout requires an operator adapter for the brand and type of disconnect being used. See Enclosure Accessories to select the operator adapter. APPLICATION The universal cutout is used in large freestand and floorstand enclosures, i.e., Bulletins A21(S), A28(S) and A34. Operator Adapter Kits are required in order to install the various manufacturers hardware. Note that 400 A (or greater) disconnect switches and 600 A (or greater) circuit breakers need to use the Large or High Amp cutout, which is provided in the A21ABVA kit for Allen-Bradley variable-depth disconnect switches or the A21ITE kit for Siemens (and select other manufacturers) flex-cable devices. The Large or High Amp cutout accepts the larger operating handle whose mounting hole centers are 6.500-in. apart. Universal cutouts are designed to house the following: Allen-Bradley Bulletin 1494F flange-mount disconnect switches and Bulletin 1494D flange-mount operators for circuit breakers Bulletin 1494V disconnect switches with flange-mount variabledepth operating mechanisms and Bulletin 1494V flange-mount variable-depth operating mechanisms for circuit breakers ORDERING The disconnect switch, operating handle and operating mechanism must be ordered separately. See Technical Information in the Hoffman Specifier s Guide for wire bend space available when various manufacturers disconnect switches are installed, or Ordering Information at hoffmanonline.com for disconnect ordering guidelines and wire bend space available. Check the enclosure dimension drawings to verify the chosen disconnect switch will fit in the enclosure. All 24.12-in. (613-mm) and deeper enclosures using short connecting rods by the following manufacturers require a Hoffman platform assembly, catalog number ADSCPA, purchased separately. ABB Controls flange-operated devices Eaton Cutler-Hammer C361 devices Eaton Cutler-Hammer C371 mechanisms which use C371E, F, G, K operating mechanism (see Enclosure Accessories) General Electric Type TDA devices (see Enclosure Accessories) Schneider Square D Class 9422 devices (see Enclosure Accessories) The platform assembly can be omitted if long connecting rods are ordered in place of short connecting rods. For Eaton Cutler-Hammer operating mechanisms C371E and C371F order catalog number C371CS1 connecting rod. For C371G and C371K order catalog number C371CS2 connecting rod. For General Electric devices, order catalog number TDSR extended length drive rod For Schneider Square D devices, order catalog number 9422-R2 extra long operating rod(s). Some devices require two rods. Consult factory for space occupied on panel when platform is used. 9 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Free-Stand Universal-Cutout s Free-Stand Universal-Cutout Overview Notes EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.422.2600 HOFFMANONLINE.COM 10