DMS 2. Ultrasonic Thickness Gague

Similar documents
The USD15 Family. The high-performance ultrasonic dialog flaw detectors with a difference - in use world-wide

EHC-03 Ultrasonic Thickness Gage

ULTRASONIC FLAW DETECTOR SONOSCREEN ST10 FOR NONDESTRUCTIVE TESTING MADE IN GERMANY

ULTRASONIC THICKNESS GAGE 38DL PLUS

ULTRASONIC THICKNESS GAGE 38DL PLUS

Quick Guide v. 3.0 Advanced model

ULTRASONIC FLAW DETECTOR SONOSCREEN ST10 FOR NONDESTRUCTIVE TESTING MADE IN GERMANY

Cygnus Surface Range. Ultrasonic Thickness Gauges. Brilliant Solutions in Ultrasonic Measurement CYGNUS REGIONAL OFFICES

DCT7088 Portable Digital Correlation Transit Time Flowmeter

USM Go A flexible Flaw Detector that can be a Thickness Gauge

OPERATION & MAINTENANCE SPECIFICATIONS MANUAL 09 07

Advanced Test Equipment Rentals ATEC (2832) PANAMETRICS. 25DL Multi-Mode Ultrasonic Thickness Gage with Internal Datalogger

USM Go A flexible Flaw Detector that can be a Thickness Gauge

ECHOGRAPH 1095 Digital Ultrasonic Flaw Detector. Models 1095 BASIC 1095 DAC/TCG/AWS 1095 DGS/DAC/TCG 1095 DGS/DAC/TCG/AWS/JIS

MTG8 Material Thickness Gauge

DEFECTOMETER High detection sensitivity to surface flaws (even underneath paint) Simple, microprocessor-controlled operation

Advanced Test Equipment Rentals ATEC (2832) DM4E DM4 DM4 DL. Operating Manual

SigmaCheck. Fully Featured Eddy Current Conductivity Meter ET NDE

UT LITE. Corrosion Inspection & Analysis for Critical Assets > COST EFFECTIVE & SCALABLE > EASY INTUITIVE SOFTWARE

Instruction Manual Ultrasonic Thickness gauge DC3020

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

SLOFEC TANK FLOOR INSPECTION REPORT

Entering a Whole New Dimension The ULTRAHEAT XS Heat Meter

Advancing with Technology

MTG6 Material Thickness Gauge

OPERATION MANUAL DAKOTA ULTRASONICS. Data Logging Thickness Gauge

CL 5. Operating Manual. Ident-Nr Issue 01

OFV-2500 Vibrometer Controllers

Data Sheet Version 1.0

HI HI N HI HI

SMALL SIZE. BIG VALUE. TOPAZ 16 BEST IN CLASS FULLY INTEGRATED 16 CHANNEL PHASED ARRAY UT DEVICE.

Elcometer 331² Model TH Concrete Covermeters

Rohmann. Rohmann Update. Eddy Current Instruments and Systems. Elotest M2. Contents. Issue 2, June 2003

GE Inspection Technologies. The NEW Phasec 3 Series. Eddy Current Flaw Detectors - A Common Platform

Mercury Tracker-3000 XS

Elcometer Protective Coatings Inspection Kits

OPERATION MANUAL DAKOTA ULTRASONICS. Material & Coating Thickness Gauge

Level and Flow Measurement. Flow Pulse

TransPort PT878. Panametrics Portable Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

B-scan Option. Encoded One-line B-scan Thickness Profiles. Key Features. Applications

Section 9 Miscellaneous Tank Parts, Suspensions & Lights

Fully Featured Eddy Current Conductivity Meter ET NDE

DPL4000 Portable Low Range Dew Point Analyzer

LSV-300 Laser Surface Velocimeter

vlocdm2 Rx & Loc-150Tx Data Sheet V1.6

SITESCAN SERIES 500S & D-50. Choose, Customise, Perform. Sitescan D-50. Sitescan 500S GENERAL PURPOSE BROADBAND DIGITAL ULTRASONIC FLAW DETECTORS

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter

OPERATION MANUAL DAKOTA ULTRASONICS. Material & Coating Thickness Gauge

TOFD. Upgradeable from UT to Phased Array or TOFD. Compact Size Higher IP Rate Low Consumption 8.4-inch Touch Screen TOFD.

vloc3-pro Technical Specifications V1.0

Manual Anemometer PCE-423

TorqueStar Opta is the equipment of choice for the measurement and collection of torque data in the manufacturing environment.

Cygnus 3 Data Logger. Operating & Accessories Manual. Doc No. M4-CYG3-M-ENG_Iss2.doc 16 April 2013 (Mk4 Cygnus 3 Gauges)

Minimize your cost for Phased Array and TOFD

OPERATION MANUAL DAKOTA ULTRASONICS. Ultrasonic Multi-Echo Data Logging Thickness Gauge

SITESCAN SERIES 500S & D-50

HI HI N HI HI

16:64PR 16:128PR MULTISCAN 32:64PR 32:128PR UT - TOFD 2PR. Simplicity Capability Reliability

PROFOMETER PM-600 / PM-630 ADVANCED CONCRETE COVER METERS

InsuLogix T Fiber Optic Probes and Extensions Installation Guide

DMTFP Portable Ultrasonic Flow Meters

Humidity goes Digital

Paint Test Equipment. Eban 4000 Coating Thickness Meter Data Sheet

Introduction. Power-up / Power-down

GE Measurement & Control Solutions. XLG3 VideoProbe. Inspection Technologies

Digital Air Velocity Meter DC580. The Value Leader TM

SITESCAN D+ Series LIGHTWEIGHT DIGITAL ULTRASONIC. SONATEST LTD

Quick Guide v. 1.1 DeFelsko Corporation USA 2012

Elcometer 456 Integral Coating Thickness Gauge

Simplicity Capability Reliability

Ultrasonic Thickness Gauge. Operation Manual

Specialists in Ultrasonic Flow Measurement

Crane Electronics Inc The force in torque management. TorqueStar Opta Torque Indicator and Data Collector

R-1000 TELEMETRY RECEIVER OPERATING MANUAL. Look inside to learn about NEW FEATURES

When speed matters.

Digital pressure gauges

Humidity goes Digital

MANUAL PCE-123

USER MANUAL UT5000 INTRINSICALLY SAFE THICKNESS GAUGE

OTS-400 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities A LANscape Solutions Product

PosiTector PC. Powder Checker Coating Thickness Gage. INSTRUCTION MANUAL v. 1.0

vlocml2 Rx Data Sheet V1.6

Integrated Instruction Manual WP 600 Series Meters

Velocity Measurement to Assess Nodularity in Ductile Iron Cast Automotive Components

High-End Ultrasonic Phased-Array System for Automatic Inspections

GE Sensing & Inspection Technologies. Apollo. Multi-Channel/Multi-Frequency Eddy Current System

OPERATION MANUAL DAKOTA ULTRASONICS. Ultrasonic Thickness Gauge

Instruction Manual COND 600/610 Waterproof Handheld Conductivity Meter

27MG Ultrasonic Thickness Gage Getting Started Guide

FRIAMAT electrofusion units. FRIAMAT Prime and FRIAMAT Basic.

TRULY AFFORDABLE EDDY CURRENT

SITRANS F flowmeters SITRANS F US

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

O P E R A T I O N A L MEGA-CHECK POCKET COATING THICKNESS METER M A N U A L

Tornado Low Light Camera

Level and Flow Measurement. Flow Pulse

Ultrasonic Flow Meter Brochure

portable waterproof multiparameter meter

Pinnacle Series interfaces: RS232C, USB and LAN. Pinnacle balances are unique in offering three interfaces for external communication.

ARP992/ ARP992-B User Reference Manual

Transcription:

DMS 2 Ultrasonic Thickness Gague

DMS 2 is the clear choice to satisfy your thickness measurement needs The DMS 2 has retained the user preferred features of its predecessor, the popular DMS, and added expanded measurement capabilities to solve remaining wall thickness applications. All information (large thickness digits, A-Scan, B-Scan, and data files) is clearly displayed on a large high resolution (1/4 VGA) LCD screen that is easily read in direct sunlight. The DMS 2 is compact, easy-to-use, and like all Krautkramer D-Meters is built-to-last in a custom molded, gasket sealed, high-impact resistant housing with a rubber protective case to withstand use in harsh industrial environments. A-Scan, B-Scan or Big DIGITS You decide what you want to see! A-Scan waveform for verification of true remaining wall thickness and better judgements on equipment integrity B-Scan provides a graphical crosssectional view of the equipment being inspected. Very helpful in quickly identifying laminated or thinned areas Big Digits (.75 High) lets you take measurements and see results at a quick glance Big Digits view is selectable with either A-Scan (shown above) or data file information displayed Advanced Thickness Measurement No need to remove coatings (paint) - measure through coatings without including the coating layer in the digital thickness reading Stable high-temperature measurement up to 1000ºF with HT400A probe and armor jacketed cable MIN CAP captures the minimum thickness for a series of measurements and displays the associated A-Scan (32 Hz acquisition rate) DIALOG Intelligent Probes are automatically recognized for optimum instrument setup, performance, and documentation Automatic probe zero corrects for delay line dimensional changes (wear & growth) 8 Hz selection updates the display twice as fast as normal for immediate response and enhances test results when movement of the probe is necessary vs. spot testing SIP mode utilizes single-element probes for attenuative or thick materials Gain is readily adjustable in 1 db steps via a direct access key Freeze locks the A-Scan display for evaluation and verification of the echoes; makes time base parameter adjustments easy 4 band passes automatically optimize the receiver bandwidth to match the frequency of the probe for best results RF display provides additional waveform information to assist with difficult measurement applications (DMS 2 only)

for simple, reliable use under harsh field conditions Easy to Use Direct access keys are at your fingertips for immediate adjustment of operating parameters Convenient color coded keypad layout Frequent text messages guide operation Compact, comfortable, one-hand control (left or right hand) TEST key simulates a home key to jump to test/measurement menu Dual/Dual-Multi hot key allows for fast toggle between Dual and Dual-Multi (thru-coat) modes Store/recall 20 parameter sets for fast instrument setup and repeatable test results Lockable keypad prevents accidental changes to operating parameters Rugged, practical packaging Custom molded, gasket-sealed, high-impact resistant plastic housing for dependable troublefree use Robust, rubber case for added protection in tough field environments Padded hand strap, neck strap, waist belt, & prop-up stand are convenient features of the rubber case Full week s work (40 hours) of use on 4 standard AA alkaline batteries - no special battery packs or battery chargers needed I/O & AC power connectors plugged by the rubber case to prevent connector contamination 2 year warranty on parts & labor Battery Compartment Field Accessory Belt Neck Strap Prop Stand Hand Strap

for powerful, flexible inspection data management Store 150,000 readings/1100 A-Scans or B-Scans on-board 8 standard file structures including compatibility with UltraPIPE files to handle most inspection routines Comprehensive D/R navigation controls allow quick & easy movement within a data file via 4 arrow keys Append, insert & delete locations to an existing data file Create Microgrids on the job to collect from 4 to 81 (2x2 to 9x9 microgrid) additional readings at identified thinned locations per API-510 and API-653 Temperature and memo input on a per file basis Expanded Memory increases the memory capacity of the onboard data recorder to 318,000 thickness readings/2,400 A-Scans or 2400 B-Scans. File status & file search to tag and jump to critical locations for quick review before leaving the job site 32 character file names & 16- character location names Save thickness readings and up to 16 alphanumeric comments with A-Scans, B-Scans, or Microgrids per reading Last reading comparison on-site of current vs. previous inspection data on a per reading basis with user set alarms for loss/growth rates & changes Internet compatible upgrade software allows instrument upgrade directly from the internet no downtime or return of equipment to factory required Easily interfaced to 3 rd party data management software programs A/C Power option for connection to mains during stationary use. Couple, read and record in one step with Remote SEND Probes. Sealed membrane send switch is built into the probes Two large SEND keys easily accessed by left or right thumb Alphanumeric key displays the virtual keyboard to easily enter alphanumeric characters Obstruct key to easily mark unreadable locations NOTE key to easily input user defined comments on a per reading basis Direct bi-directional communication with UltraMATE & UltraPIPE software programs for straight-forward data storage, analysis, & management

to solve a wide range of corrosion/erosion applications Stable high temperature measurement The DMS 2 in combination with the HT 400A dual-element probe and armor jacketed cable provide stable measurement on equipment having surface temperatures up to 1000ºF (538ºC). Single-element high-temperature delay line probes are also compatible. Use of the MIN CAP mode in combination with FREEZE enables high temperature readings and A-Scans to be obtained quickly without lift-off effects from uncoupling. 4 ways to measure without removing expensive protective coatings for maximum flexibility TopCOAT, Dual-Multi, S-Peak and S-Flank modes for measuring through coatings (paint) without including the coating layer in the digital thickness reading. Measurements are made between two consecutive backwall echoes in all modes (except TopCOAT) and low amplitude coating layer echoes are ignored. (See back page for more information on TopCOAT.) Test materials with external pitting Small footprint dual-element probes are used to gain access to the bottom of surface pits to measure true minimum remaining wall thickness on corrosion prone equipment (i.e. piping, pressure vessels, storage tanks, plates). Obtain stable thickness measurements on small diameter piping and tubing. Measure in areas of limited access. Find and capture thinnest reading during corrosion/erosion surveys The MIN CAP (MINimum CAPture) measurement mode finds and captures the minimum thickness reading in a sequence of measurements. Both the live and currently captured minimum thickness readings are displayed simultaneously. An adjustable time-out period (1 to 10 seconds) prevents a new min cap sequence from starting prematurely upon intermittent uncoupling. The DMS 2 works with DME, DM4 Family, and DMS dual & single element probes for maximum flexibility and applications versatility.

with new powerful expanded measurement capabilities and valuable options TopCOAT(Patent No. 6035717) is a new thickness measurement technique utilizing 2 channels (one channel measures the coating thickness and one measures the total thickness) that works like this: Measures the coating thickness Calculates the necessary coating layer correction Measures the total thickness of the coating layer and metal layer Deducts the calculated coating correction value Displays the correct (metal only) thickness Advantages of the TopCOAT measurement technique. 1. Measure through coatings (paint) without including the coating layer in the digital thickness reading. Thinner measurements are also possible than when using multiple echo techniques. 2. Allows normal high gain corrosion thickness measurement with maximum sensitivity to pitting. Measurement is made at high gain levels and from the initial pulse to the 1 st backwall reflection which is proven to be the most effective way to measure equipment having irregular backwall reflecting surfaces (i.e. eroded/corroded piping, tanks, pressure vessels ). 3. Measure the thickness of the coating (paint) layer itself. 4. If no coating is present, measure the thickness of materials from one side without knowing their sound velocity. Paint Coating Inside of pipe (showing corrosion) Coating Measurement Total Thickness Measurement The current velocity of the material under test is measured and set into the instrument. Thickness measurements are made without knowing the sound velocity of the material. Thickness of various materials can be measured without recalibration. B-Scan is a simple inspection method enabling the user to scan a part or area and produce a cross-sectional view. No probes switching, extra cables or fixtures needed; the DMS 2 B-Scan works with ANY TG Probe. Easy to use soft key controls enable the user to quickly configure the B-Scan parameters to produce the best graphical views possible. The DMS 2 goes further and allows the user to save the B- Scan within its internal memory (user can save up to 1,100 B-Scans) and later transfer the B-Scan to our UltraMATE software for storage to disk, analysis and printing. AgfaNDT.com Visit the NDT Super Site, AgfaNDT.com, for more information on Krautkramer s DMS 2 and to learn more about Agfa NDT s complete line of ultrasonic, x-ray, digital and film systems Agfa NDT Inc. 50 Industrial Park Road Lewistown, PA 17044 USA Tel : (717)242-0327 Fax : 717/242-2606 E-mail: infolink@agfandtinc.com Agfa NDT GmbH Robert-Bosch-Str 3 D 50354 Huerth (Efferen) Germany Tel : +49-2233-6010 Fax : +49-2233-601402 E-mail: hotline@agfandt.de Agfa NDT Ltd. Millburn Hill Road University of Warwick Science Park Coventry, England CV4 7HS United Kingdom Tel : +44 0845 601 5771 Fax : +44 0845 130 5775 E-mail: ndt-sales.gb.ng@agfa.co.uk Agfa NDT SA 68, Chemin des Ormeaux F 69760, Limonest France Tel : +33-472-179220 Fax : +33-478-475698 E-mail: ndt@france.agfa.com DMS2/CT07025k Printed In USA